首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Intramolecular carbon isotope ratios reflect the source of a compound and the reaction conditions prevailing during synthesis and degradation. We report here a method for determination of relative (Deltadelta13C) and absolute (delta13C) intramolecular isotope ratios using the volatile lactic acid analogue propylene glycol as a model compound, measured by on-line gas chromatography-pyrolysis coupled to GC-combustion-isotope ratio mass spectrometry. Pyrolytic fragmentation of about one-third of the analyte mass produces optimal fragments for isotopic analysis, from which relative isotope ratios (Deltadelta13C) are calculated according to guidelines presented previously. Calibration to obtain absolute isotope ratios is achieved by quantifying isotope fractionation during pyrolysis with an average fractionation factor, alpha, and evaluated by considering extremes in isotopic fractionation behavior. The method is demonstrated by calculating ranges of absolute intramolecular isotope ratios in four samples of propylene glycol. Relative and absolute isotope ratios were calculated with average precisions of SD(Deltadelta13C) <0.84 per thousand and SD(delta13C) <3.0 per thousand, respectively. The various fractionation scenarios produce an average delta(13)C range of 2 per thousand for each position in each sample. Relative isotope ratios revealed all four samples originated from unique sources, with samples A, B, and D only distinguishable at the position-specific level. Regardless of pyrolysis fractionation distribution, absolute isotope ratios showed a consistent pattern for all samples, with delta13C(3) > delta13C(2) > delta13C(1). The validity of the method was determined by examining the difference in relative isotope ratios calculated through two independent methods: Deltadelta13C calculated directly using previous methods and Deltadelta13C extracted from absolute isotope ratios. Deviation between the two Deltadelta13C values for all positions averaged 0.1-0.2 per thousand, with the smallest deviation obtained assuming equal fractionation across all fragment positions. This approach applies generally to all compounds analyzed by pyrolytic PSIA.  相似文献   

2.
Recent advances in gas chromatography combustion-isotope ratio mass spectrometry (GCC-IRMS) has made compound-specific isotope analysis routine, but reports on position-specific isotopic analysis are still scarce. On-line GC-pyrolysis (Py) coupled to GCC-IRMS is reported here for isolation and isotopic characterization of alaninol and phenethylamine, analogues of alanine and phenylalanine, respectively. Ideally, pyrolytic fragments will originate from unique sites within the parent molecule, and isotope ratios for each position within the parent can either be measured directly or calculated from fragment isotope ratios without substantially degrading the analytical precision. Alaninol pyrolysis yielded several fragments, of which CO and CH4 were used for isotope ratio calculations. Isotope labeling experiments showed that CO derived entirely from the C(1) position, while all three positions of alaninol contributed to CH4 (29.0 +/- 0.3% from C(1), 3.6 +/- 0.2% from C(2), and 66.9 +/- 1.1% from C(3)). We demonstrate iterative use of mass balance to calculate isotope ratios from all positions despite the nonideal positional fidelity of CH4. Pyrolysis of phenethylamine generated benzene and toluene fragments. Benzene derived entirely from C(ring), and toluene was proportionately formed from C(3) and C(ring). Relative intramolecular isotope ratios (Deltadelta13C) were calculated directly from delta13C of fragments or indirectly by mass balance. Though the C(3) isotope ratio was calculated from the benzene and toluene fragments, propagation of errors showed that the final precision of the determination was degraded due to the small contribution that C(3) makes to toluene. Samples of each amino acid from four different vendors showed natural variability between sources, especially at the C(1) position of alaninol (range of Deltadelta13C approximately 50 per thousand). The average precision was SD(Deltadelta13C) < 0.20 per thousand for directly measured positions of alaninol and phenethylamine. The precision of indirectly measured positions was poorer (SD(Deltadelta13C) = 0.94 per thousand for alaninol, 6.54 per thousand for phenethylamine) due to propagation of errors. These data demonstrate that GC-Py-GCC-IRMS data can be used to extract high-precision isotope ratios from amino acids despite nonideal positional fidelity in fragments and that natural intramolecular variability in delta13C can be used to distinguish different sources of amino acids.  相似文献   

3.
A new method for the measurement of SI traceable carbon isotope amount ratios using a multicollector inductively coupled mass spectrometer (MC-ICPMS) is reported for the first time. Carbon (13)C/(12)C isotope amount ratios have been measured for four reference materials with carbon isotope amount ratios ranging from 0.010659 (delta(13)C(VPDB) = -46.6 per thousand) to 0.011601 (delta(13)C(VPDB) = +37 per thousand). Internal normalization by measuring boron (11)B/(10)B isotope amount ratios has been used to correct for the effects of instrumental mass bias. Absolute (13)C/(12)C ratios have been measured and corrected for instrumental mass bias and full uncertainty budgets have been calculated using the Kragten approach. Corrected (13)C/(12)C ratios for NIST RM8545 (Lithium Carbonate LSVEC), NIST RM8573 (L-Glutamic Acid USGS40), NIST RM8542 (IAEA-CH6 Sucrose) and NIST RM8574 (L-Glutamic Acid USGS41) differed from reference values by 0.06-0.20%. Excellent linear correlation (R = 0.9997) was obtained between corrected carbon isotope amount ratios and expected carbon isotope amount ratios of the four chosen NIST RMs. The method has proved to be linear within this range (from (13)C/(12)C = 0.010659 to (13)C/(12)C =0.011601), and therefore, it is suitable for the measurement of carbon isotope amount ratios within the natural range of variation of organic carbon compounds, carbonates, elemental carbon, carbon monoxide, and carbon dioxide. In addition, a CO2 gas sample previously characterized in-house by conventional dual inlet isotope ratio mass spectrometry has been analyzed and excellent agreement has been found between the carbon isotope amount ratio value measured by MC-ICPMS and the IRMS measurements. Absolute values for carbon isotope amount ratios traceable to the SI are given for each NIST RM, and the combined uncertainty budget (including instrumental error and each parameter contributing to Russell expression for mass bias correction) has been found to be < 0.1% for the four materials. The advantage of the method versus conventional gas source isotope ratio mass spectrometry measurements is that carbon isotope amount ratios are measured as C(+) instead of CO2(+), and therefore, an oxygen (17)O correction due to the presence of (12)C(17)O(16)O(+) is not required. Organic compounds in solution can be measured without previous derivatization, combustion steps, or both, thus making the process simple. The novel methodology opens new avenues for the measurement of absolute carbon isotope amount ratios in a wide range of samples.  相似文献   

4.
We describe our development of a CH4 preconcentration system for use with continuous-flow gas chromatograph combustion isotope ratio mass spectrometry (GC/C/IRMS). Precision of measurement of delta13C-CH4 is 0.05/1000 (1sigma) on multiple 60-mL aliquots of the same ambient air sample. The same front-end on-line CH4 preconcentration system allows us to measure deltaD of CH4 by gas chromatography IRMS when the combustion furnace is replaced with a pyrolysis oven (GC/P/IRMS). Precision of measurement for deltaD-CH4 is 1.5/1000 (1sigma) using 120 mL of ambient air based on multiple aliquots of the same air sample. These are the first reported measurements of atmospheric CH4 using GC/P/IRMS methodology. Each isotope analysis can be made much more rapidly (30-40 min) than they could using off-line combustion of an air sample (1-6 h) followed by conventional dual-inlet IRMS measurements (12-20 min), while requiring much less total volume and retaining a comparable level of precision and accuracy. To illustrate the capabilities of our preconcentration GC/C/IRMS system, we compare the results of measurement of 24 background air samples made using both GC/C/IRMS and conventional vacuum line/dual-inlet IRMS methodology. The air samples were collected on a shipboard air sampling transect made across the Pacific Ocean in July 2000 and are part of an ongoing atmospheric CH4 research program. The average difference between the two methods of IRMS analyses on these 24 samples is 0.01 +/- 0.03/1000 (95% confidence interval) for delta3C-CH4. These are the first measurements to be reported of air samples directly intercompared for delta13C-CH4 using both GC/C/IRMS and dual-inlet IRMS measurement methodology. Measurement of deltaD-CH4 of these air samples is also presented as an illustration of the ability of this system to resolve small isotopic differences in remote air. High-precision measurement of delta13C and deltaD of atmospheric CH4 made using our coupled preconcentration GC/IRMS system will greatly improve our ability to utilize isotopic data in understanding spatial and temporal changes in atmospheric CH4 and the biogeochemistry of its sources and sinks.  相似文献   

5.
We report the first coupling of comprehensive two-dimensional gas chromatography (GC x GC) to online combustion isotope ratio mass spectrometry (C-IRMS). A GC x GC system, equipped with a longitudinally modulated cryogenic system (LMCS), was interfaced to an optimized low dead volume combustion interface to preserve <300 ms full width at half-maximum (fwhm) fast GC peaks generated on the second GC column (GC2). The IRMS detector amplifiers were modified by configuration of resistors and capacitors to enable fast response, and a home-built system acquired data at 25 Hz. Software was home-written to handle isotopic time shifts of less than one bin (40 ms) and to integrate peak slices to recover isotope ratios from cryogenically sliced peaks. The performance of the GC x GCC-IRMS system was evaluated by isotopic analysis of urinary steroid standards. Steroids were separated by a nonpolar GC1 column (30 m x 0.25 mm, 5% phenyl), modulated into multiple 4- or 8-s cryogenic slices by the LMCS, and then separated on a polar GC2 column (1 or 2 m x 0.1 mm, 50% phenyl). GC2 peak widths from a 1-m column averaged 276 ms fwhm. Steroid standard sliced peaks were successfully reconstructed to yield delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.30 per thousand and average accuracies within 0.34 per thousand, at 8 ng on column. Two steroids, coeluting in GC1, were baseline separated in GC2 and resulted in delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.86 per thousand and average accuracies within 0.26 per thousand, at 3 ng on column. Results from this prototype system demonstrate that the enhanced peak capacity and signal available in GC x GC is compatible with high-precision carbon isotope analysis.  相似文献   

6.
Carbon isotope ratios in higher-plant organic matter (delta(13)C(plant)) have been shown in several studies to be closely related to the carbon isotope composition of the ocean-atmosphere carbon reservoir, and, in particular, the isotopic composition of CO(2). These studies have primarily been focused on geological intervals in which major perturbations occur in the oceanic carbon reservoir, as documented in organic carbon and carbonates phases (e.g. Permian-Triassic and Triassic-Jurassic boundary, Early Toarcian, Early Aptian, Cenomanian-Turonian boundary, Palaeocene-Eocene Thermal Maximum (PETM)). All of these events, excluding the Cenomanian-Turonian boundary, record negative carbon isotope excursions, and many authors have postulated that the cause of such excursions is the massive release of continental-margin marine gas-hydrate reservoirs (clathrates). Methane has a very negative carbon isotope composition (delta(13)C, ca. 60 per thousand ) in comparison with higher-plant and marine organic matter, and carbonate. The residence time of methane in the ocean-atmosphere reservoir is short (ca. 10 yr) and is rapidly oxidized to CO(2), causing the isotopic composition of CO(2) to become more negative from its assumed background value (delta(13)C, ca. -7 per thousand ). However, to date, only the Early Toarcian, Early Aptian and PETM are well-constrained chronometric sequences that could attribute clathrate release as a viable cause to create such rapid negative delta(13)C excursions. Notwithstanding this, the isotopic analysis of higher-plant organic matter (e.g. charcoal, wood, leaves, pollen) has the ability to (i) record the isotopic composition of palaeoatmospheric CO(2) in the geological record, (ii) correlate marine and non-marine stratigraphic successions, and (iii) confirm that oceanic carbon perturbations are not purely oceanographic in their extent and affect the entire ocean-atmosphere system. A case study from the Isle of Wight, UK, indicates that the carbon isotope composition of palaeoatmospheric CO(2) during the Mid-Cretaceous had a background value of 3 per thousand, but fluctuated rapidly to more positive (ca. +0.5 per thousand ) and negative values (ca. 10 per thousand ) during carbon cycle perturbations (e.g. carbon burial events, carbonate platform drowning, large igneous province formation). Hence, fluctuations in the carbon isotope composition of palaeoatmospheric CO(2) would compromise our use of palaeo-CO(2) proxies that are dependent on constant carbon isotope ratios of CO(2).  相似文献   

7.
Here we describe an on-line method for measuring delta(37)Cl values of chloride bearing salts, waters, and organic materials using multicollector continuous-flow isotope ratio mass spectrometry (CF-IRMS). Pure AgCl quantitatively derived from total Cl in water, inorganic Cl salts, and biological samples was reacted with iodomethane in evacuated 10-mL stopper sealed glass vials to produce methyl chloride gas. A GV Instruments Multicollector CF-IRMS with CH(3)Cl optimized collector geometry was modified to accommodate a headspace single-sample gas injection port prior to a GC column. The GC column was a 2-m Porapak-Q packed column held at 160 degrees C. The resolved sample CH(3)Cl was introduced to the IRMS source in a helium stream via an open split. delta(37)Cl values were calculated by measurement of CH(3)Cl at m/z 52/50 and by comparison to a reference pulse of CH(3)Cl calibrated to standard mean ocean chloride. Sample CH(3)Cl analysis time was approximately 6 min. Injections of 40 microL of pure CH(3)Cl gas yielded a repeatability (+/-SD) of +/-0.06 per thousand for delta(37)Cl (n = 10). Combined GC and IRMS source linearity for CH(3)Cl was <0.2 per thousand/nA (V) peak height. External repeatability, based on processing of seawater and NaCl reference solutions, was better than +/-0.08 per thousand. The smallest sample for delta(37)Cl analysis by this method was approximately 0.2 micromol of Cl. Selected results from a river basin and biological samples study illustrate the potential of on-line chlorine isotope assays in environmental pollution studies.  相似文献   

8.
Isotopomers 12CO2 and 13CO2 absorbed into polystyrene films provide narrow, sharp, and well-resolved IR absorption bands for the nu3 antisymmetric stretching mode. This is exploited to set up an inexpensive FT-IR-based method for the measurement of the carbon isotope ratio. Accuracy of 2.5 per thousand delta13C units is readily achieved already at a low resolution of 2 cm(-1).  相似文献   

9.
Upon closer inspection, the classical view of the synchronous relationship between tropospheric methane mixing ratio and Greenland temperature observed in ice samples reveals clearly discernable variations in the magnitude of this response during the Late Pleistocene (<50kyr BP). During the Holocene this relationship appears to decouple, indicating that other factors have modulated the methane budget in the past 10kyr BP. The delta13CH4 and deltaD-CH4 of tropospheric methane recorded in ice samples provide a useful constraint on the palaeomethane budget estimations. Anticipated changes in palaeoenvironmental conditions are recorded as changes in the isotope signals of the methane precursors, which are then translated into past global delta13CH4 and deltaD-CH4 signatures. We present the first methane budgets for the late glacial period that are constrained by dual stable isotopes. The overall isotope variations indicate that the Younger Dryas (YD) and Preindustrial Holocene have methane that is 13C- and 2H-enriched, relative to Modern. The shift is small for delta13CH4 (approx. 1 per thousand) but greater for deltaD-CH4 (approx. 9 per thousand). The YD delta13CH4-deltaD-CH4 record shows a remarkable relationship between them from 12.15 to 11.52kyr BP. The corresponding C- and H-isotope mass balances possibly indicate fluctuating emissions of thermogenic gas. This delta13CH4-deltaD-CH4 relationship breaks down during the YD-Preboreal transition. In both age cases, catastrophic releases of hydrates with Archaeal isotope signatures can be ruled out. Thermogenic clathrate releases are possible during the YD period, but so are conventional natural gas seepages.  相似文献   

10.
Interlaboratory comparisons involving nine European stable isotope laboratories have shown that the routine methods of cellulose preparation resulted in data that generally agreed within the precision of the isotope ratio mass spectrometry (IRMS) method used: +/-0.2 per thousand for carbon and +/-0.3 per thousand for oxygen. For carbon, the results suggest that holocellulose is enriched up to 0.39 per thousand in 13C relative to the purified alpha-cellulose. The comparisons of IRMS measurements of carbon on cellulose, sugars, and starches showed low deviations from -0.23 to +0.23 per thousand between laboratories. For oxygen, IRMS measurements varied between means from -0.39 to 0.58 per thousand, -0.89 to 0.42 per thousand, and -1.30 to 1.16 per thousand for celluloses, sugars, and starches, respectively. This can be explained by different effects arising from the use of low- or high-temperature pyrolysis and by the variation between laboratories in the procedures used for drying and storage of samples. The results of analyses of nonexchangeable hydrogen are very similar in means with standard deviations between individual methods from +/-2.7 to +/-4.9 per thousand. The use of a one-point calibration (IAEA-CH7) gave significant positive offsets in delta2H values up to 6 per thousand. Detailed analysis of the results allows us to make the following recommendations in order to increase quality and compatibility of the common data bank: (1) removal of a pretreatment with organic solvents, (2) a purification step with 17% sodium hydroxide solution during cellulose preparation procedure, (3) measurements of oxygen isotopes under an argon hood, (4) use of calibration standard materials, which are of similar nature to that of the measured samples, and (5) using a two-point calibration method for reliable result calculation.  相似文献   

11.
The relevance of both modern and fossil carbon contamination as well as isotope fractionation during preparative gas chromatography for compound-specific radiocarbon analysis (CSRA) was evaluated. Two independent laboratories investigated the influence of modern carbon contamination in the sample cleanup procedure and preparative capillary gas chromatography (pcGC) of a radiocarbon-dead 3,3',4,4',5,5'-hexachlorobiphenyl (PCB 169) reference. The isolated samples were analyzed for their 14C/12C ratio by accelerator mass spectrometry. Sample Delta14C values of -996 +/- 20 and -985 +/- 20 per thousand agreed with a Delta14C of -995 +/- 20 per thousand for the unprocessed PCB 169, suggesting that no significant contamination by nonfossil carbon was introduced during the sample preparation process at either laboratory. A reference compound containing a modern 14C/12C ratio (vanillin) was employed to evaluate process contamination from fossil C. No negative bias due to fossil C was observed (sample Delta14C value of 165 +/- 20 per thousand agreed with Delta14C of 155 +/- 12 per thousand for the unprocessed vanillin). The extent of isotopic fractionation that can be induced during pcGC was evaluated by partially collecting the vanillin model compound of modern 14C/12C abundance. A significant change in the delta13C and delta14C values was observed when only parts of the eluting peak were collected (delta13C values ranged from -15.75 to -49.91 per thousand and delta14C values from -82.4 to +4.71 per thousand). Delta14C values, which are normalized to a delta13C of -25 per thousand, did not deviate significantly (-58.9 to -5.8 per thousand, considering the uncertainty of approximately +/-20 per thousand). This means that normalization of radiocarbon results to a delta13C of -25 per thousand, normally performed to remove effects of environmental isotope fractionation on 14C-based age determinations, also cor-rects sufficiently for putative isotopic fractionation that may occur during pcGC isolation of individual compounds for CSRA.  相似文献   

12.
New guidelines for delta13C measurements   总被引:1,自引:0,他引:1  
Consistency of delta13C measurements can be improved 39-47% by anchoring the delta13C scale with two isotopic reference materials differing substantially in 13C/12C. It is recommended that delta13C values of both organic and inorganic materials be measured and expressed relative to VPDB (Vienna Peedee belemnite) on a scale normalized by assigning consensus values of -46.6 per thousand to L-SVEC lithium carbonate and +1.95 per thousand to NBS 19 calcium carbonate. Uncertainties of other reference material values on this scale are improved by factors up to two or more, and the values of some have been notably shifted: the delta13C of NBS 22 oil is -30.03 per thousand.  相似文献   

13.
We report a new method developed for the determination of stable carbon isotopic composition of homologous alpha,omega-dicarboxylic acids and phthalic acid isolated from environmental samples such as atmospheric aerosols and snow. Dicarboxylic acids are derivatized with BF3/1-butanol to dibutyl esters, which are analyzed for the stable carbon isotopic composition using a capillary GC interfaced to on-line combustion isotope ratio mass spectrometer. The delta13C values for individual dicarboxylic acid are then calculated from delta13C of 1-butanol and butyl ester derivative using a mass balance equation. The accuracy of the delta13C measurement for C2-C10 diacids is within 0.8 per thousand. We report a few examples of the delta13C ratios of saturated C2-C9 alpha,omega-dicarboxylic acids, unsaturated (maleic, phthalic) diacids, and oxocarboxylic acids in the aerosol and snow samples.  相似文献   

14.
Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry was used to determine the delta15N and delta13C signatures of selected nitroaromatic contaminants such as the explosive 2,4,6-trinitrotoluene (TNT) for derivation of isotopic enrichment factors of contaminant transformation. Parameters for efficient extraction of nitroaromatic compounds (NACs) and substituted anilines from water samples were evaluated by SPME-GC/MS. delta13C signatures determined by SPME-GC/IRMS and elemental analyzer IRMS (EA-IRMS) were in good agreement, generally within +/-0.7 per thousand, except for 2,4-dinitrotoluene (2,4-DNT) and TNT, which showed slight deviations (<1.3 per thousand). Limits of detection (LODs) for delta13C analysis by SPME-GC/IRMS were between 73 and 780 microg L-1 and correlated with the extraction efficiencies of the compounds determined by SPME-GC/MS. Nitrogen isotope measurements by SPME-GC/IRMS were of similar precision (standard deviations <0.8 per thousand) for all NACs except for TNT. delta15N signatures matched the reference values obtained by EA-IRMS within +/-1.3 per thousand (+2.5 per thousand for TNT), but no systematic trend was found for the deviations. LODs of delta15N measurements ranged from 1.6 to 9.6 mg L-1 for nitrotoluenes, chlorinated NACs and DNTs (22 mg L-1 for TNT). The SPME-GC/IRMS method is well suited for the determination of isotopic enrichment factors of various NAC transformation processes and provides so far unexplored possibilities to elucidate behavior and degradation mechanisms of nitroaromatic contaminants in soils and groundwaters.  相似文献   

15.
The stable isotope composition of dissolved organic carbon (delta(13)C-DOC) provides powerful information toward understanding carbon sources and cycling, but analytical limitations have precluded its routine measurement in natural samples. Recent interfacing of wet oxidation-based dissolved organic carbon analyzers and isotope ratio mass spectrometers has simplified the measurement of delta(13)C-DOC in freshwaters, but the analysis of salty estuarine/marine samples still proves difficult. Here we describe the coupling of the more widespread high-temperature catalytic oxidation-based total organic carbon analyzer to an isotope ratio mass spectrometer (HTC-IRMS) through cryogenic trapping of analyte gases exiting the HTC analyzer for routine analysis of delta(13)C-DOC in aquatic and marine samples. Targeted elimination of major sources of background CO2 originating from the HTC analyzer allows for the routine measurement of samples over the natural range of DOC concentrations (from 40 microM to over 2000 microM), and salinities (<0.1-36 g/kg). Because consensus reference natural samples for delta(13)C-DOC do not exist, method validation was carried out with water-soluble stable isotope standards as well as previously measured natural samples (IAEA sucrose, Suwannee River Fulvic Acids, Deep Sargasso Sea consensus reference material, and St. Lawrence River water) and result in excellent delta(13)C-DOC accuracy (+/-0.2 per thousand) and precision (+/-0.3 per thousand).  相似文献   

16.
Yu YX  Wen S  Feng YL  Bi XH  Wang XM  Peng PA  Sheng GY  Fu JM 《Analytical chemistry》2006,78(4):1206-1211
A novel method has been developed for the compound-specific carbon isotope analysis of atmospheric formaldehyde using gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The method allows the determination of the delta13C value for atmospheric formaldehyde at nanogram levels with higher precision and lower detection limit. In the present work, atmospheric formaldehyde was collected using NaHSO3-coated Sep-Pak silica gel cartridges, washed out by water, then derivatized by cysteamine of known delta13C value, and the delta13C value of its derivative (thiazolidine) determined by GC/C/IRMS. Finally, the delta13C value of atmospheric formaldehyde could be calculated by a simple mass balance equation between formaldehyde, cysteamine, and thiazolidine. Using three formaldehydes with different delta13C values, calibration experiments were carried out over large ranges of formaldehyde concentrations. The carbon isotope analysis method achieved excellent reproducibility and high accuracy. There was no carbon isotopic fractionation throughout the derivatization processes. The differences in the carbon isotopic compositions of thiazolidine between the measured and predicted values were always <0.5 per thousand, within the specifications of the GC/C/IRMS system. The present method was also compared with the previous 2,4-dinitrophenylhydrazine derivatization method, and this method could be performed with lower analytical error and detection limit. Using this method, four 6-h ambient atmospheric formaldehyde samples were consecutively collected from 8 to 9 March 2005. The results showed that the delta13C values of atmospheric formaldehyde were different during the daytime and nighttime. This method proved suitable for the routine operation and may provide additional insight on sources and sinks of atmospheric formaldehyde.  相似文献   

17.
15N/14N isotope ratios are widely used to study processes and systems involving amino acids. Nitrogen isotope fractionation in biological processes occurs primarily at sites of bond-breaking and formation; the finest discrimination for "isotopic fingerprinting" and studies of isotopic fluxes is thus obtained at the position-specific level. While there are numerous reports of natural intramolecular carbon isotope variability, there are no literature reports of 15N/14N position-specific isotopic analysis (N-PSIA) of biologically relevant molecules. We report a methodology for high-precision N-PSIA of four polynitrogenous alpha-amino acids (asparagine, glutamine, lysine, histidine) and the first survey of natural intramolecular 15N/14N in these biomolecules. Selective liberation of N-atoms from multiple commercial standards of each parent amino acid was achieved by an appropriate enzymatic reaction or by acid hydrolysis. 15N/14N measurements were performed on N-ethoxycarbonyl ethyl ester derivatives of the parent amino acids and their analogues by gas chromatography combustion isotope ratio mass spectrometry, and the average precision for replicate injections was found to be SD(delta15N) = 0.3%. Position-specific delta15N values of the parent amino acid were directly observed or indirectly calculated using mass balance. The average precision obtained for directly measured positions was SD(delta15N) = 0.2-0.4%. The average precision for indirectly obtained positions was SD(delta15N) = 0.6-1.3% as a result of propagation of errors. Enrichment in the side chain-N with respect to the peptide-N was observed in nearly all of the amino acid sources, most notably in asparagine (average delta delta(side-peptide) = + 11%), which may be indicative of its method of production. In some cases, it was possible to distinguish commercial sources by N-PSIA that could not be distinguished at the compound-specific level.  相似文献   

18.
A thermal decomposition method was developed and tested for the simultaneous determination of delta 18O and delta 17O in nitrate. The thermal decomposition of AgNO3 allows for the rapid and accurate determination of 18O/ 16O and 17O/16O isotopic ratios with a precision of +/- 1.5 per thousand for delta 18O and +/- 0.11 per thousand for delta 17O (delta 17O = delta 17O - 0.52 x delta 18O). The international nitrate isotope reference material IAEA-NO3 yielded a delta 18O value of +23.6 per thousand and delta 17O of -0.2 per thousand, consistent with normal terrestrial mass-dependent isotopic ratios. In contrast, a large sample of NaNO3 from the Atacama Desert, Chile, was found to have delta 17O = 21.56 +/- 0.11 per thousand and delta 18O = 54.9 +/- 1.5 per thousand, demonstrating a substantial mass-independent isotopic composition consistent with the proposed atmospheric origin of the desert nitrate. It is suggested that this sample (designated USGS-35) can be used to generate other gases (CO2, CO, N2O, O2) with the same delta 17O to serve as measurement references for a variety of applications involving mass-independent isotopic compositions in environmental studies.  相似文献   

19.
A novel derivatization procedure, N-acetyl methyl (NACME) esterification, was developed to improve the accuracy and precision of amino acid delta13C value determination using gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS). Standard mixtures of 15 protein amino acids were converted to NACME and N-acetyl-isopropyl (NAIP) esters; the latter established derivative was employed for comparison purposes. Both procedures yielded baseline-resolved peaks for all 15 amino acids when GC columns coated with polar stationary phases were employed. For NACME esters, the methylation conditions governed reaction yields, with highest yields observed when a 1 h, 70 degrees C methylation procedure (anhydrous MeOH/acetyl chloride, 25:4, v/v) was performed. The mean derivatization yields expressed relative to an underivatized coinjected standard (n-nonadecane) for both NACME and NAIP esters were identical. Likewise, the mean kinetic isotope effects (KIEs) were not significantly different (KIE(NACME) = 1.036; KIE(NAIP) = 1.038) and were shown in both cases to be reproducible. The mean reproducibility obtained from 15 replicates (3 x batches of 5) of both derivatives was strong (mean STDV(NACME) = 0.3 per thousand and STDV(NAIP) = 0.4 per thousand). The isotopic robustness of both derivatization procedures was observed over a concentration range of 52,500 microg of amino acid. NACME esters displayed low errors (+/-0.6 per thousand for phenylalanine to +/-1.1 per thousand for serine) due to the higher sample-to-derivative carbon ratio of this derivative. Finally, the integrity of the new NACME procedure was confirmed through analysis of diet and bone collagen amino acids of rats reared on C3 or C4 diets, which indicated the high degree of both accuracy and precision of the delta13C values obtained for individual amino acids.  相似文献   

20.
Three different KNO3 salts with delta18O values ranging from about -31 to +54 per thousand relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with delta18O values in the midpoint of the delta18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25 per thousand). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the 6180 scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with delta18O values far from that of atmospheric O2, to improve interlaboratory comparability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号