1.
黄俊  顾洁  王晓博 《节能》2012,31(2):55-58
通过对某多孔太阳墙式太阳能房间和普通房间的数值模拟,分析太阳墙板内空气的受热过程及流动情况,同时系统地比较两种建筑在工作区范围内的热舒适性。与普通采暖房间相比,在有多孔太阳墙送风的情况下,可将室外空气由-3℃加热到21℃,空气流动速度由0.1m/s提高到0.31m/s,提供44.6m3/h的新风量,一定程度上解决了冬季开窗换气所引起的室内热负荷及采暖负荷,论证了多孔太阳墙可使室内热舒适性明显增强的结论。  相似文献   

2.
分析了户用太阳热水器和太阳热水系统工程的经济技术特点,对两者成本构成、项目财务净现值、投入回收期和财务内部收益率等有关指标进行了经济技术比较.分析比较表明,太阳热水系统与家用热水器相比,节省安装占地,与建筑相结合得好,在降低成本,缩短投资回收期,提高经济效益方面有明显的优势.  相似文献   

3.
The thermal performance of thermosyphon flat-plate solar water heater with a mantle heat exchanger was investigated to show its applicability in China. The effect on the performance of the collector of using a heat exchanger between the collector and the tank was analyzed. A “heat exchanger penalty factor” for the system was determined and energy balance equation in the system was presented. Outdoor tests of thermal performance of the thermosyphon flat-plate solar water heater with a mantle heat exchanger were taken in Kunming, China. Experimental results show that mean daily efficiency of the thermosyphon flat plate solar water heater with a mantle heat exchanger with 10 mm gap can reach up to 50%, which is lower than that of a thermosyphon flat-plate solar water heater without heat exchanger, but higher than that of a all-glass evacuated tubular solar water heater.  相似文献   

4.
Extensive experimental studies on a compact solar water heater were carried out, in order to evaluate the performance of the heater and determine the optimal depth of the storage tank. The experiments were conducted for tank depths of 5, 10 and 15 cm with single and double glazing. Experimental results show that a temperature rise of about 68 °C during the month of July at storage tank depth of 10 cm can be achieved by the heater. The 10 cm depth of the tank is optimum which can supply hot water for 24 h. The rise of water temperature is slightly higher in the case of single glazing than the double glazed system, while the double glazed system is more effective in retaining higher temperatures during night hours.  相似文献   

5.
In this paper, improving the thermal performance of flat plate solar water heater systems by inserting different tube configurations inside the riser pipes has been numerically and experimentally studied. This study is focused on increasing the moving of energy from riser pipes to the operating fluid within the riser pipes. To achieve that, the diameter of the riser pipes was increased along with the insertion of different tube configurations within them, namely, smooth, helical, and wavy tubes, keeping the same amount of the operating liquid. A comparison was performed to determine the best in terms of coefficient of heat transfer of the operating liquid, mass flow rate of the operating liquid, pressure drop, and water temperature in the storage tank, as a thermal performance indication of the system under study. The findings show the model consisting of a straight tube inside the riser pipe provides the best thermal performance. In terms of thermal performance, the straight model outperforms the conventional model by 12.3%. An experimental and numerical comparison between the optimum model (straight model) was conducted. The study proves that the average difference between numerical results and experimental findings is 7.2%.  相似文献   

6.
An experimental investigation is carried out on a forced circulation solar water heater to assess its performance under various operating conditions. The system consisted of two identical collectors of total absorber area of 3.45 m2 and a storage tank of 200 litre capacity. Experiments were carried out during clear days with and without system loading for two water mass flow rates through the collector; namely 0.1305 kg/s and 0.06525 kg/s. The system was operated without thermostat control and with thermostat control at maximum and minimum settings. The collector efficiency improved with system loading. The improvement was better with increased hot water withdrawal from the system.  相似文献   

7.
The effect of Fe nanofluid on the performance enhancement on solar water heater integrated with thermal energy storage system is investigated experimentally. A 0.5% wt fraction of Fe nanoparticle was synthesized with the mixture of water/propylene‐glycol base fluid. The experimental implementation utilized 40‐nm‐size Fe nanoparticle, 15 ° collector tilt angle, and 1.5 kg/min mass flow rate heat‐transfer fluid circulation. The system efficiency reached 59.5% and 50.5% for with and without nanofluid. The water tank temperature was increased by 13 °C during night mode. The average water tank temperature at night mode was 47.5 °C, while the average ambient temperature was 26 °C. The Fe nanofluid improved the system working duration during night mode by an average of 5 h. The techno‐economic analysis results showed a yearly estimated cost savings of 28.5% using the Fe nanofluids as heat transfer fluid. The embodied energy emission rate, collector size, and weight can be reduced by 9.5% using nanofluids. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
An electrical analog model, derived from the energy balance equations, is presented for the flat-plate solar water heating system. Measurements on the model are in good agreement with experimentally obtained and theoretical values.  相似文献   

9.
满虹  吕建  杨洪兴 《节能》2012,31(5):61-63
以天津地区典型气象年的气象数据为基础,利用综合能源价格法,分析使用年限、集热器面积对壁挂式太阳能热水器经济性的影响,并与其他热水器进行经济性比较,对其进行节能效益分析,评价壁挂式太阳能热水器的经济性和节能效益。  相似文献   

10.
The performance of a DHW system fitted with flat-plate and vacuum collectors has been analysed. Simulations were carried out on the basis of equal aperture or gross areas of basis using TMY data for hour-by-hour dynamic simulation generated for 1036 sites located in different regions of the world. The performance indicators of solar fractions and number of days were determined for specific water mean temperatures in the storage tank of 37 °C, 45 °C and 55 °C. It has been shown that vacuum tube collectors provide slightly better DHW performance indicators than typical flat-plate collectors having the same aperture area. However, since the space that needs to be provided and directly or indirectly paid for is what matters to the user of solar heating systems, the analysis was also carried out on equal gross area basis; on this basis, the advantages of using vacuum collectors are not obvious.  相似文献   

11.
新型太阳能集热墙冬季保温性能分析   总被引:1,自引:1,他引:0  
建立新型结构的太阳能集热墙,给出新型太阳能集热墙的结构组成.利用CFD技术对新型太阳能集热墙系统采暖房间的温度场进行了模拟,给出室内温度场的分布规律,并分析了室内温度日变化情况;通过对比分析新型太阳能集热墙与传统太阳能集热墙的温度场分布,验证了新型太阳能集热墙具有良好的保温节能性能.  相似文献   

12.
An experimental investigation has been carried out on a thermosyphon solar water heater. The system consisted of a flat-plate collector of 1.5 m2 absorber area with 21 tubes/m width and storage tank of 125 litre capacity. Experiments were carried out for both cloudy and clear weather conditions in winter and summer. The hourly system performance was evaluated for all test conditions. The final mean tank temperature was measured daily which enabled the calculation of the possible contribution of solar energy for domestic hot water supply in Basrah, Iraq (latitude 30.76°N). The system was tested at both no-load and loading conditions. Intermittent and continuous load was imposed, and system performance was evaluated for each condition.  相似文献   

13.
W. Saman  F. Bruno  E. Halawa 《Solar Energy》2005,78(2):341-349
The thermal performance of a phase change thermal storage unit is analysed and discussed. The storage unit is a component of a roof integrated solar heating system being developed for space heating of a home. The unit consists of several layers of phase change material (PCM) slabs with a melting temperature of 29 °C. Warm air delivered by a roof integrated collector is passed through the spaces between the PCM layers to charge the storage unit. The stored heat is utilised to heat ambient air before being admitted to a living space. The study is based on both experimental results and a theoretical two dimensional mathematical model of the PCM employed to analyse the transient thermal behaviour of the storage unit during the charge and discharge periods. The analysis takes into account the effects of sensible heat which exists when the initial temperature of the PCM is well below or above the melting point during melting or freezing. The significance of natural convection occurring inside the PCM on the heat transfer rate during melting which was previously suspected as the cause of faster melting process in one of the experiments is discussed. The results are compared with a previous analysis based on a one dimensional model which neglected the effect of sensible heat. A comparison with experimental results for a specific geometry is also made.  相似文献   

14.
This work presents an unsteady state theoretical and experimental investigation of natural circulation two phase closed thermosyphon flat plate solar water heaters. The governing equations of the heater storage tank and connecting pipes are presented and generalized in dimensionless form, while the governing equations of the different components of the collector were previously discussed by the author. Also, the author's earlier simulation program of the collector is modified to include the solution of the dimensionless governing equations of the present analysis. For verifying the modified simulation program, a two phase closed thermosyphon solar water heater is designed, constructed and tested at different meteorological conditions, initial storage tank temperatures and different hot water withdrawal load patterns. The comparison between the experimental results and their corresponding simulated ones shows considerable agreement.  相似文献   

15.
A simple analysis of an underground shallow solar pond water heater has been presented. The effect of a thermal trap at the top of the system has also been incorporated in the analysis. Using the model, the effect of various system parameters, viz. thermal trap thickness, heat capacity of water mass, flow rate and duration of flow rate have been studied in detail. Numerical calculations have been made for a typical winter day at New Delhi (India). It is concluded that the system with thermal trap gives better performance in comparison with a system with a movable insulation system.  相似文献   

16.
结合多孔太阳墙建筑,运用数值模拟方法分析了不同太阳墙结构对室内送风参数的影响,比较了太阳能房间与普通房间在工作区范围内的热舒适性,并对太阳能房间的窗墙面积比进行了优化改进。研究表明:对太阳墙的设计优化,增大了太阳墙面积,提高了室内热舒适性;改进后房间窗墙比为0.303,窗地比为0.2,符合节能建筑要求。  相似文献   

17.
The performance of a cylindrical solar water heater   总被引:2,自引:0,他引:2  
Hussain Al-Madani   《Renewable Energy》2006,31(11):1751-1763
A cylindrical solar water heater is designed and manufactured in the Department of Mechanical Engineering, University of Bahrain. It consists of a cylindrical tube made from high quality glass having a length of 0.8, 0.14 m outer diameter and a thickness of 6 mm. A copper coil tube in the shape of spiral rings, with the tube inner diameter of 2 mm and outer diameter of 3.175 mm, painted black, serves as a collector to the incident solar energy on the cylinder wall. The thermal performance was evaluated extensively throughout the months of March and April 2002; a maximum temperature difference of 27.8 °C between inlet and outlet of the solar water heater at a mass flow rate of 9 kg/h was achieved. The efficiency of the cylindrical solar water heater was calculated. The maximum value during the experimental period was found to be 41.8%. This reveals a good capability of the system to convert solar energy to heat which can be used for heating water. An economic analysis has reveals that the cylindrical solar water heater compared with the flat plate collector is cost effective.  相似文献   

18.
This paper presents the results of an experimental investigation of the performance for a new flat plate solar air heater (SAH) with several obstacles (Type I, Type II, and Type III) and without obstacles (Type IV). The efficiencies, the heat gain factors and heat loss coefficients are determined for the collectors and comparisons were made among them. The experimental data along with the correlations obtained by linear regression are presented. The optimal value of efficiency was determined for the solar air heater with Type II absorbent plate in flow channel duct for all operating conditions and the collector supplied with obstacles appears significantly better than that without obstacles.  相似文献   

19.
This article investigates experimentally the long-term thermal performance of a two-phase thermosyphon solar water heater and compares the results with the conventional systems. Experimental investigations are conducted to obtain the system thermal efficiencies from the hourly, daily and long-term performance tests. Different heat transfer mechanisms, including natural convection, geyser boiling, nucleate boiling and film-wise condensation, are observed in the two-phase thermosyphon solar water heater while solar radiation varies. The thermal performance of the proposed system is compared with that of four conventional solar water heaters. Results show that the proposed system achieves system characteristic efficiency 18% higher than that of the conventional systems by reducing heat loss for the two-phase thermosyphon solar water heater.  相似文献   

20.
This paper focuses on enhancing the energy collection efficiency of an integrated collector storage solar water heater (ICS SWH) by vee-corrugating the absorber and optimizing the design for the vee-included angle through simulation and experimental study. This paper presents an efficient algorithm for analyzing a vee-corrugated absorber ICS SWH using Engineering Equation Solver Software. For validating this algorithm, two models of ICS SWH systems have been fabricated: one with a flat absorber and the other with a 60° vee-included angle corrugated absorber with eight corrugations. The basic purpose of the fabrication of the flat absorber ICS SWH system was to approximate the absorptivity of the absorber. A typical value of 0.68 was estimated for the absorptivity of the aluminum absorber coated with nonselective black paint. After the experimental investigation of the 60° vee-included angle ICS SWH system, it was found that the real-time readings were in close agreement with the numerical model readings. For comparison with the previous work, a five-corrugation system with an approximate 90° vee-included angle with the same projected dimensions was modeled and the efficiencies of both the models for the time from 7 a.m. to 3 p.m. were calculated. The efficiency of the eight-corrugation model was 42.56%, which was better than the previous work of the five-corrugation model, with a 38.86% efficiency for the same ambient conditions. Also, it was theoretically deduced that we had an optimized system at 18 corrugations and a vee-included angle of 28.78°.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏