首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
Freshwater pinch analysis (FWaPA) as an extended pinch analysis technique has been proposed for retrofitting the off-grid batteryless photovoltaic-powered reverse osmosis system (PVS-RO) with a water storage tank to minimize the required outsourced freshwater. The freshwater composite curve (FWaCC) as the graphical tool, and freshwater storage cascade table (FWaSCT) as the numerical tool of the FWaPA are introduced to determine the optimal delivered electricity to the RO system, water storage tank capacity, and wasted electricity in each time-interval with minimized outsourced freshwater. A multi-objective optimization algorithm by combining FWaPA numerical tool and genetic algorithm (FWaPA-GA) minimizes three objective functions including required outsourced freshwater during first operation year, outsourced freshwater during normal operation year, and total annual cost of the system to obtain the optimal number of PV panels, membranes, and capacity of water storage tank. The FWaPA-GA was implemented to find optimal design of an off-grid PVS-RO-WT system for a case study in Kish island, Iran. The results clearly represented that the FWaPA-GA can be used to grassroots design of the desalination systems with renewable energy sources, where the designed PVS-RO-WT system for the case study needs 178.5 m3 freshwater to provide 10 m3/d freshwater-on-demand with the total annual cost of 13,652 $/year.  相似文献   

2.
In this paper we present firstly the different hybrid systems with fuel cell. Then, the study is given with a hybrid fuel cell–photovoltaic generator. The role of this system is the production of electricity without interruption in remote areas. It consists generally of a photovoltaic generator (PV), an alkaline water electrolyzer, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to manage the system operation of the hybrid system. Different topologies are competing for an optimal design of the hybrid photovoltaic–electrolyzer–fuel cell system. The studied system is proposed. PV subsystem work as a primary source, converting solar irradiation into electricity that is given to a DC bus. The second working subsystem is the electrolyzer which produces hydrogen and oxygen from water as a result of an electrochemical process. When there is an excess of solar generation available, the electrolyzer is turned on to begin producing hydrogen which is sent to a storage tank. The produced hydrogen is used by the third working subsystem (the fuel cell stack) which produces electrical energy to supply the DC bus. The modelisation of the global system is given and the obtained results are presented and discussed.  相似文献   

3.
This paper designs an off-grid charging station for electric and hydrogen vehicles. Both the electric and hydrogen vehicles are charged at the same time. They appear as two electrical and hydrogen load demand on the charging station and the charging station is powered by solar panels. The output power of solar system is separated into two parts. On part of solar power is used to supply the electrical load demand (to charge the electric vehicles) and rest runs water electrolyzer and it will be converted to the hydrogen. The hydrogen is stored and it supplies the hydrogen load demand (to charge the hydrogen-burning vehicles). The uncertainty of parameters (solar energy, consumed power by electrical vehicles, and consumed power by hydrogen vehicles) is included and modeled. The fuel cell is added to the charging station to deal with such uncertainty. The fuel cell runs on hydrogen and produces electrical energy to supply electrical loading under uncertainties. The diesel generator is also added to the charging station as a supplementary generation. The problem is modeled as stochastic optimization programming and minimizes the investment and operational costs of solar and diesel systems. The introduced planning finds optimal rated powers of solar system and diesel generator, operation pattern for diesel generator and fuel cell, and the stored hydrogen. The results confirm that the cost of changing station is covered by investment cost of solar system (95%), operational cost of diesel generator (4.5%), and investment cost of diesel generator (0.5%). The fuel cell and diesel generator supply the load demand when the solar energy is zero. About 97% of solar energy will be converted to hydrogen and stored. The optimal operation of diesel generator reduces the cost approximately 15%.  相似文献   

4.
The aim of this research is to analyze the techno‐economic performance of hybrid renewable energy system (HRES) using batteries, pumped hydro‐based, and hydrogen‐based storage units at Sharurah, Saudi Arabia. The simulations and optimization process are carried out for nine HRES scenarios to determine the optimum sizes of components for each scenario. The optimal sizing of components for each HRES scenario is determined based on the net present cost (NPC) optimization criterion. All of the nine optimized HRES scenarios are then evaluated based on NPC, levelized cost of energy, payback period, CO2 emissions, excess electricity, and renewable energy fraction. The simulation results show that the photovoltaic (PV)‐diesel‐battery scenario is economically the most viable system with the NPC of US$2.70 million and levelized cost of energy of US$0.178/kWh. Conversely, PV‐diesel‐fuel cell system is proved to be economically the least feasible system. Moreover, the wind‐diesel‐fuel cell is the most economical scenario in the hydrogen‐based storage category. PV‐wind‐diesel‐pumped hydro scenario has the highest renewable energy fraction of 89.8%. PV‐wind‐diesel‐pumped hydro scenario is the most environment‐friendly system, with an 89% reduction in CO2 emissions compared with the base‐case diesel only scenario. Overall, the systems with battery and pumped hydro storage options have shown better techno‐economic performance compared with the systems with hydrogen‐based storage.  相似文献   

5.
Hydrogen as a storage medium in renewable energy systems has been the subject of various studies in recent years. Such a system consists of a long-term and a short-term storage system. In a battery, energy is stored for short term whereas the electrolyser, H2-tank and fuel cell combination is used for long-term energy storage to increase the reliability of supply. The same purpose can be achieved by introducing a diesel generator instead of long-term storage. The advantage of such a system is that it needs low investment cost. However, the main disadvantage is that it needs to supply fuel for the operation of the generator. The advantage of hydrogen-based long-term storage over a diesel generator is that it does not need any supply of fuel. In photovoltaic–wind–diesel hybrid systems, the surplus energy during the good season is not stored.In the present study, the possible sites for renewable applications are specified depending on the seasonal renewable energy variation and fuel cost at the site of application. The critical fuel cost is calculated depending on the seasonal solar and wind energy difference. The actual fuel cost at the site of application is compared with critical fuel cost. To find out the actual fuel cost at the location of application, the transportation cost is also included. If the actual fuel cost is higher than the critical fuel cost, the location is cost-effective for hydrogen-based storage. Otherwise, the site is suitable for a diesel-generator backup system. It is found that at present hydrogen storage is not cost-effective compare to a diesel-generator-based system. In the near future when the target cost of the electrolyser and the fuel cell is achieved, the scope of the hydrogen-based storage system will also increase and it will also be cost competitive with diesel-generator system for remote applications.  相似文献   

6.
Hybrid diesel–PV–battery systems are one of the most cost effective options for off-grid power generation. A methodology for the optimal operation of such systems for an off-grid application is proposed in this paper. The methodology is based on the minimisation of an energy cost function. Based on this function, an optimal operating point for the diesel generator is identified, taking into account the characteristics of the diesel generator, battery bank and converter as well as the costs of fuel and battery usage. The operation of the diesel generator at this optimum operating point results in an overall energy cost reduction for the hybrid diesel–battery system. Simulation analysis shows that the proposed control strategy can achieve up to 4% reduction in the levelised cost of energy. This is mostly due to the savings made from the efficient usage of diesel generator and battery.  相似文献   

7.
The rapid increase of renewable energy sources made coordinated control of the distributed and intermittent generation units a more demanded task. Matching demand and supply is particularly challenging in islanded microgrids. In this study, we have demonstrated a mixed‐integer quadratic programming (MIQP) method to achieve efficient use of sources within an islanded microgrid. A unique objective function involving fuel consumption of diesel generator, degradation in a lithium‐ion battery energy storage system, carbon emissions, load shifting, and curtailment of the renewable sources is constructed, and an optimal operating point is pursued using the MIQP approach. A systematic and extensive methodology for building the objective function is given in a sequential and explicit manner with an emphasis on a novel model‐based battery aging formulation. Performance of the designed system and a sensitivity analysis of resulting battery dispatch, diesel generator usage, and storage aging against a range of optimization parameters are presented by considering real‐world specifications of the Semakau Island, an island in the vicinity of Singapore.  相似文献   

8.
Decentralization of electrical power generation using rooftop solar units is projected to develop to not only mitigate power losses along transmission and distribution lines, but to control greenhouse gases emissions. Due to intermittency of solar energy, traditional batteries are used to store energy. However, batteries have several drawbacks such as limited lifespan, low storage capacity, uncontrolled discharge when not connected to a load and limited number of charge/discharge cycles. In this paper, the feasibility of using hydrogen as a battery is analyzed where hydrogen is produced by the extra diurnal generated electricity by a rooftop household solar power generation unit and utilized in a fuel cell system to generate the required electrical power at night. In the proposed design, two rooftop concentrated photovoltaic thermal (CPVT) systems coupled with an organic Rankine cycle (ORC) are used to generate electricity during 9.5 h per day and the extra power is utilized in an electrolyzer to produce hydrogen. Various working fluids (Isobutane, R134a, R245fa and R123) are used in the ORC system to analyze the maximum feasible power generation by this section. Under the operating conditions, the generated power by ORC as well as its efficiency are evaluated for various working fluids and the most efficient working fluid is selected. The required power for the compressor in the hydrogen storage process is calculated and the number of electrolyzer cells required for the hydrogen production system is determined. The results indicate that the hybrid CPVT-ORC system produces 2.378 kW of electricity at 160 suns. Supplying 65% of the produced electricity to an electrolyzer, 0.2606 kg of hydrogen is produced and stored for nightly use in a fuel cell system. This amount of hydrogen can generate the required electrical power at night while the efficiency of electrolyzer is more than 70%.  相似文献   

9.
Computer simulation is an increasingly popular tool for determining the most suitable hybrid energy system type, design and control for an isolated community or a cluster of villages. This paper presents the development of the optimum control algorithm based on combined dispatch strategies, to achieve the optimal cost of battery incorporated hybrid energy system for electricity generation, during a period of time by solving the mathematical model, which was developed in Part I of this tri-series paper.The main purpose of the control system proposed here is to reduce, as much as possible, the participation of the diesel generator in the electricity generation process, taking the maximum advantage of the renewable energy resources available.The overall load dispatch scenario is controlled by the availability of renewable power, total system load demand, diesel generator operational constraints and the proper management of the battery bank. The incorporation of a battery bank makes the control operation more practical and relatively easier.  相似文献   

10.
As the share of distributed renewable power generation increases, high electricity prices and low feed-in tariff rates encourage the generation of electricity for personal use. In the building sector, this has led to growing interest in energy self-sufficient buildings that feature battery and hydrogen storage capacities. In this study, we compare potential technology pathways for residential energy storage in terms of their economic performance by means of a temporal optimization model of the fully self-sufficient energy system of a single-family building, taking into account its residential occupancy patterns and thermal equipment. We show for the first time how heat integration with reversible solid oxide cells (rSOCs) and liquid organic hydrogen carriers (LOHCs) in high-efficiency, single-family buildings could, by 2030, enable the self-sufficient supply of electricity and heat at a yearly premium of 52% against electricity supplied by the grid. Compared to lithium-ion battery systems, the total annualized cost of a self-sufficient energy supply can be reduced by 80% through the thermal integration of LOHC reactors and rSOC systems.  相似文献   

11.
A modular system for the supply of remote electrical consumers was developed, which makes possible a variable integration of wind energy and photovoltaic plants in connection with a diesel engine and a battery storage. The wind energy converters, equipped with asynchronous generators, and a fast pitch control, work parallel with a synchronous generator. The generator is driven by a diesel engine by means of an overrunning clutch, or started by a small DC-motor. If the diesel is off, or the starting process by the DC-motor is finished, the synchronous generator works as a rotating phase-shifter and takes over voltage control and supply of reactive power.

The speed versus power control of the wind energy converters does not only make possible an optimized parallel operation with the diesel-generator unit, but also directly takes over frequency control when operated singly without diesel engine. The location of the wind energy plants does not depend on the site of the diesel engine, because control cables are not necessary. To avoid too frequent starting of the diesel, a storage battery is installed. The report describes the electrical and control technical design on principle, as well as the experience with the following, already built plants:

-Coupling of two wind energy plants for the supply of water irrigation pumps.

-Combination of two WECs with a short-time battery storage and a diesel-set.

-Combination of two WECs with a photovoltaic generator and a battery storage.  相似文献   

12.
In most isolated sites situated in south Algeria, the diesel generators are the major source of electrical energy. Indeed, the power supply of these remote regions still poses order problems (technical, economical and ecological). The electricity produced with the help of diesel generators is very expensive and responsible for CO2 emission. These isolated sites have significant wind energy potential. Hence, the use of twinning wind-diesel is widely recommended, especially to reduce operating deficits. The objective of this paper is to study the global modeling of a hybrid system which compounds wind turbine generator, diesel generator and storage system. This model is based on the control strategy to optimize the functioning of the hybrid system and to consolidate the gains to provide proper management of energy sources (wind, diesel, battery) depending on the load curve of the proposed site. The management is controlled by a controller which ensures the opening/closing of different power switches according to meteorological conditions (wind speed, air mass, temperature, etc).  相似文献   

13.
A comprehensive thermoeconomic analysis is presented for a novel integrated solar hydrogen energy system for standalone operation. The proposed system includes a solar PVT module (photovoltaic thermal), a FC (Fuel cell) and a battery to meet the electrical load demand and domestic hot water over a year. The PVT component works as a primary energy source converting solar energy into electricity and heat. The excess electrical energy and hot water produced by PVT are consumed for producing hydrogen, which can be stored. The generated hydrogen is fed to the fuel cell to produce electricity and water to satisfy the demand. The proposed system is convenient for different seasons of the year because in all time, produced power satisfy the demand. The first and second laws of thermodynamics are used to evaluate the performance of each component and the overall system. Economic assessment of this system is also conducted considering the net present cost, and the system performance is optimized based on this parameter. The overall electrical efficiency of the system is obtained as 9% and the levelized cost of electricity is determined as $ 0.286/kWh. For a steady operation of system, integrating a battery system is convenient when solar energy is not available for a short term. When there is a longer-term shortage of solar radiation, up to 8 days, the electricity can be supplied by utilizing the hydrogen storage system.  相似文献   

14.
This paper presents a study that focuses on alleviating the impacts of grid outages in Ethiopia. To deal with grid outages, most industrial customers utilize backup diesel generators (DG) which are environmentally unfriendly and economically not viable. Grid-integration of hybrid renewable energy systems (HRES) might be a possible solution to enhance grid reliability and reduce environmental and economic impacts of utilizing DG. In this study, an optimization of grid integrated HRES is carried out for different dispatch and control strategies. The optimal power supply option is determined by performing comparative analysis of the different configurations of grid integrated HRES. The result of the study shows that grid integrated HRES consisting of photovoltaic and wind turbine as renewable energy sources, and battery and hydrogen as hybrid energy storage systems is found to be the optimal system to supply the load demand. From the hydrogen produced on-site, the FC generator and FCEVs consume 143 620 kg/yr of hydrogen which is equivalent to 394 955 kg/yr gasoline fuel consumption. This corresponds to saving 1 184 865 kg/yr of CO2 emissions and 605 703 $/yr revenue. Besides, this system yields 547 035.4 $/yr revenue by injecting excess electricity to the grid. The study clearly shows the economic and environmental viability of this new technology for implementation.  相似文献   

15.
The commercial development and current economic incentives associated with energy storage using redox flow batteries (RFBs) are summarised. The analysis is focused on the all‐vanadium system, which is the most studied and widely commercialised RFB. The recent expiry of key patents relating to the electrochemistry of this battery has contributed to significant levels of commercialisation in, for example, Austria, China and Thailand, as well as pilot‐scale developments in many countries. The potential benefits of increasing battery‐based energy storage for electricity grid load levelling and MW‐scale wind/solar photovoltaic‐based power generation are now being realised at an increasing level. Commercial systems are being applied to distributed systems utilising kW‐scale renewable energy flows. Factors limiting the uptake of all‐vanadium (and other) redox flow batteries include a comparatively high overall internal costs of $217 kW?1 h?1 and the high cost of stored electricity of ≈ The commercial development and current economic incentives associated with energy storage using redox flow batteries (RFBs) are summarised. The analysis is focused on the all‐vanadium system, which is the most studied and widely commercialised RFB. The recent expiry of key patents relating to the electrochemistry of this battery has contributed to significant levels of commercialisation in, for example, Austria, China and Thailand, as well as pilot‐scale developments in many countries. The potential benefits of increasing battery‐based energy storage for electricity grid load levelling and MW‐scale wind/solar photovoltaic‐based power generation are now being realised at an increasing level. Commercial systems are being applied to distributed systems utilising kW‐scale renewable energy flows. Factors limiting the uptake of all‐vanadium (and other) redox flow batteries include a comparatively high overall internal costs of $217 kW?1 h?1 and the high cost of stored electricity of ≈ $0.10 kW?1 h?1. There is also a low‐level utility scale acceptance of energy storage solutions and a general lack of battery‐specific policy‐led incentives, even though the environmental impact of RFBs coupled to renewable energy sources is favourable, especially in comparison to natural gas‐ and diesel‐fuelled spinning reserves. Together with the technological and policy aspects associated with flow batteries, recent attempts to model redox flow batteries are considered. The issues that have been addressed using modelling together with the current and future requirements of modelling are outlined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
The standalone hybrid power system constitutes a synchronous generator driven by a diesel engine, renewable energy source (wind) apart from a battery energy storage system. A coherent control strategy to regulate the voltage and frequency of the standalone grid is proposed in this paper. The system is simulated using Matlab/Simulink for preliminary validation and further tested on a laboratory prototype which involves a TMS320LF2407A DSP controller to digitally implement the control strategy. The dynamic behavior of the system is perused through the direct connection of an induction machine. The control strategy is verified for step changes in load and variation in wind power.  相似文献   

17.
Integration of wind machines and battery storage with the diesel plants is pursued widely to reduce dependence on fossil fuels. The aim of this study is to assess the impact of battery storage on the economics of hybrid wind‐diesel power systems in commercial applications by analyzing wind‐speed data of Dhahran, East‐Coast, Kingdom of Saudi Arabia (K.S.A.). The annual load of a typical commercial building is 620,000 kWh. The monthly average wind speeds range from 3.3 to 5.6 m/s. The hybrid systems simulated consist of different combinations of 100‐kW commercial wind machines (CWMs) supplemented with battery storage and diesel generators. National Renewable Energy Laboratory's (NREL's) (HOMER Energy's) Hybrid Optimization Model for Electric Renewables (HOMER) software has been employed to perform the economic analysis. The simulation results indicate that for a hybrid system comprising of 100‐kW wind capacity together with 175‐kW diesel system and a battery storage of 4 h of autonomy (i.e. 4 h of average load), the wind penetration (at 37‐m hub height, with 0% annual capacity shortage) is 25%. The cost of generating energy (COE, $/kWh) from this hybrid wind–battery–diesel system has been found to be 0.139 $/kWh (assuming diesel fuel price of 0.1$/L). The investigation examines the effect of wind/battery penetration on: COE, operational hours of diesel gensets. Emphasis has also been placed on un‐met load, excess electricity, fuel savings and reduction in carbon emissions (for wind–diesel without battery storage, wind–diesel with storage, as compared to diesel‐only situation), cost of wind–battery–diesel systems, COE of different hybrid systems, etc. The study addresses benefits of incorporation of short‐term battery storage (in wind–diesel systems) in terms of fuel savings, diesel operation time, carbon emissions, and excess energy. The percentage fuel savings by using above hybrid system is 27% as compared to diesel‐only situation Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
In recent years, renewable energy can be seen as one of the important prospect of today's research, as it is likely to enlighten the lives of millions of people by fulfilling demand of electricity in their daily life. The present work focuses on the development of optimal hybrid energy system sizing model based on comparative analysis of particle swarm optimization, genetic algorithm and Homer software for energy index ratio of 1. The model also incorporates renewable fraction, emissions of carbon di oxide from diesel generator, net present cost and cost of energy. The system is developed to supply the demand of 7 un-electrified villages of Dhauladevi block of Almora district in Uttarakhand, India with the help of the available resources of solar, hydro, biomass and biogas energy along with the addition of diesel generator, for meeting out the energy deficit. From the optimization results, minimum cost of energy and maximum renewable fraction are obtained as 5.77 Rs/kWh and 92.6% respectively.  相似文献   

19.
A dynamic model for a stand-alone renewable energy system with hydrogen storage (RESHS) is developed. In this system, surplus energy available from a photovoltaic array and a wind turbine generator is stored in the form of hydrogen, produced via an electrolyzer. When the energy production from the wind turbine and the photovoltaic array is not enough to meet the load demand, the stored hydrogen can then be converted by a fuel cell to produce electricity. In this system, batteries are used as energy buffers or for short time storage. To study the behavior of such a system, a complete model is developed by integrating individual sub-models of the fuel cell, the electrolyzer, the power conditioning units, the hydrogen storage system, and the batteries (used as an energy buffer). The sub-models are valid for transient and steady state analysis as a function of voltage, current, and temperature. A comparison between experimental measurements and simulation results is given. The model is useful for building effective algorithms for the management, control and optimization of stand-alone RESHSs.  相似文献   

20.
Renewable energy resources play a very important rule these days to assist the conventional energy systems for doing its function in the UAE due to high greenhouse gas (GHG) emissions and energy demand. In this paper, the analysis and performance of integrated standalone hybrid solar PV, fuel cell and diesel generator power system with battery energy storage system (BESS) or supercapacitor energy storage system (SCESS) in Khorfakkan city, Sharjah were presented. HOMER Pro software was used to model and simulate the hybrid energy system (HES) based on the daily energy consumption for Khorfakkan city. The simulation results show that using SCESS as an energy storage system will help the performance of HES based on the Levelized cost of energy (LCOE) and greenhouse gas (GHG) emissions. The HES with SCESS has renewable fraction (68.1%) and 0.346 $/kWh LCOE. The HES meets the annual AC primary load of the city (13.6 GWh) with negligible electricity excess and with an unmet electrical load of 1.38%. The reduction in GHG emissions for HES with SCESS was 83.2%, equivalent to saving 814,428 gallons of diesel.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号