共查询到20条相似文献,搜索用时 0 毫秒
1.
The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the series-connected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. 相似文献
2.
Thermal performance of PCM thermal storage unit for a roof integrated solar heating system 总被引:2,自引:0,他引:2
The thermal performance of a phase change thermal storage unit is analysed and discussed. The storage unit is a component of a roof integrated solar heating system being developed for space heating of a home. The unit consists of several layers of phase change material (PCM) slabs with a melting temperature of 29 °C. Warm air delivered by a roof integrated collector is passed through the spaces between the PCM layers to charge the storage unit. The stored heat is utilised to heat ambient air before being admitted to a living space. The study is based on both experimental results and a theoretical two dimensional mathematical model of the PCM employed to analyse the transient thermal behaviour of the storage unit during the charge and discharge periods. The analysis takes into account the effects of sensible heat which exists when the initial temperature of the PCM is well below or above the melting point during melting or freezing. The significance of natural convection occurring inside the PCM on the heat transfer rate during melting which was previously suspected as the cause of faster melting process in one of the experiments is discussed. The results are compared with a previous analysis based on a one dimensional model which neglected the effect of sensible heat. A comparison with experimental results for a specific geometry is also made. 相似文献
3.
There has been a growing interest in utilizing forest biomass for energy generation in district heating systems to reduce dependence on fossil fuels. However, variability in forest biomass availability and quality over time and its complex and costly supply chain have made investments in forest biomass energy generation projects less attractive. In this paper, a linear programming model is developed to minimize the delivery cost of forest biomass to the gate of heating plants and determine the optimal monthly flow of biomass to the plants. The model has a 1‐year planning horizon with monthly time steps. It determines (1) the amount of woodchips that should be transported to the plants from supply sources directly and through the terminal storages, (2) the amount of biomass that should be stored at supply sources and at terminal storages, and (3) the amount of biomass that should be chipped at supply sources and at terminal storages. The model was applied to a potential district heating system in Williams Lake, BC, Canada. The results of the optimization model indicated that it would not be economical to carry out the chipping process at the terminal storage. Biomass should be chipped at supply sources, and woodchips should be sent to the terminal storage and/or directly to the plant. Of the total optimum annual flow of woodchips to the plant, 90% is transported directly, while 10% is transported to the plant via the terminal storage. It would cost $43.38 Odt?1 to deliver forest biomass to the plant. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
4.
The role of district heating in future renewable energy systems 总被引:1,自引:0,他引:1
Based on the case of Denmark, this paper analyses the role of district heating in future Renewable Energy Systems. At present, the share of renewable energy is coming close to 20 per cent. From such point of departure, the paper defines a scenario framework in which the Danish system is converted to 100 per cent Renewable Energy Sources (RES) in the year 2060 including reductions in space heating demands by 75 per cent. By use of a detailed energy system analysis of the complete national energy system, the consequences in relation to fuel demand, CO2 emissions and cost are calculated for various heating options, including district heating as well as individual heat pumps and micro CHPs (Combined Heat and Power). The study includes almost 25 per cent of the Danish building stock, namely those buildings which have individual gas or oil boilers today and could be substituted by district heating or a more efficient individual heat source. In such overall perspective, the best solution will be to combine a gradual expansion of district heating with individual heat pumps in the remaining houses. Such conclusion is valid in the present systems, which are mainly based on fossil fuels, as well as in a potential future system based 100 per cent on renewable energy. 相似文献
5.
This paper presents a stochastic mixed-integer linear programming approach for solving the self-scheduling problem of a price-taker thermal and wind power producer taking part in a pool-based electricity market. Uncertainty on electricity price and wind power is considered through a set of scenarios. Thermal units are modelled by variable costs, start-up costs and technical operating constraints, such as: forbidden operating zones, ramp up/down limits and minimum up/down time limits. An efficient mixed-integer linear program is presented to develop the offering strategies of the coordinated production of thermal and wind energy generation, having as a goal the maximization of profit. A case study with data from the Iberian Electricity Market is presented and results are discussed to show the effectiveness of the proposed approach. 相似文献
6.
Analytical models have been put forward to predict the thermal performance of passive heating systems, which have previously been suggested. The systems consist of a water vessel for heat storage and a structure positioned on its outside wall, which act as a solar collector and a thermal insulation for the storage, respectively. Four different variations of structures have been considered and numerical calculations performed corresponding to the physical parameters of an earlier reported experimental study. The analysis is able to predict the experimental results fairly satisfactorily. 相似文献
7.
Concern for the environment has been steadily growing in recent years, and it is becoming more common to include environmental impact and pollution costs in the design problem along with construction, investment and operating costs. 相似文献
8.
Many states in Eastern and Central Europe (ECE) possess extensive district heating (DH) networks that were constructed during the days of communist rule in order to provide a universally accessible energy service that supported Soviet development policies. But the post-communist transition was marked by the exacerbation of the sector’s numerous technical, economic, regulatory and environmental problems, accompanied by its abandonment in favour of alternative methods of domestic heating. Recent efforts to increase the use of DH in ECE as a result of environmental and energy security concerns have taken place in an absence of critical, context-sensitive research. 相似文献
9.
A straightforward analysis of a solar water heating system with n-tanks connected in series has been presented. The long-term performance of the system has also been studied. On the basis of numerical calculations made for four successive days, the following conclusions have been drawn:
- 1. (1) The fluctuation in temperature variation decreases with increase of the number of tanks connected in series.
- 2. (2) The variation becomes smooth after the second successive day, which is more desirable from the point of view of users.
10.
In order to produce process heat for drying of agricultural, textile, marine products, heating of buildings and re-generating dehumidify agent, solar energy is one of the promising heat sources for meeting energy demand without putting adverse impact of environment. Hence it plays a key role for sustainable development. Solar energy is intermittent in nature and time dependent energy source. Owing to this nature, PCMs based thermal energy storage system can achieve the more popularity for solar energy based heating systems. The recent researches focused on the phase change materials (PCMs), as latent heat storage is more efficient than sensible heat storage. In this paper an attempt has been made to present holistic view of available solar air heater for different applications and their performance. 相似文献
11.
The paper presents a static linear programming model of a district heating system in which the base load is covered by a cogenerating station producing heat and electricity. The model provides optimal investment decisions (generating station, hot water accumulator, peak units, distribution network) as well as optimal operating rules. The reliability of the cogenerating station is taken explicitly into account by introducing shortage costs in case of failure. It is assumed the electricity produced is sold at time-variable transfer prices to the public grid. Numerical results are provided for a medium-size city. 相似文献
12.
The purpose of this study is to investigate the possibility of using low-enthalpy geothermal energy from the geothermal field of Sousaki in the province of Korinthos, Greece, to cover the thermal needs of the nearby town of Ag. Theodori. The possibility of developing a system of district heating was examined based on a proposed town model. Total thermal demands were calculated on the basis of a model dwelling and prevailing weather conditions in the area. Subsequently, a heat transfer circuit is proposed, including the distribution network, the heat exchanger, the production and reinjection pumps, and the pumping station. Finally, energy indices are presented, such as demand in tons of equivalent oil and CO2 emissions. 相似文献
13.
The Danish city Frederikshavn is aiming at becoming a 100% renewable energy city. The city has a number of energy resources including a potential for off-shore wind power, waste and low-temperature geothermal energy usable as heat source for heat pumps producing district heating. 相似文献
14.
One vital means of raising energy efficiency is to introduce district heating in industry. The aim of this paper is to study factors which promote and inhibit district heating collaborations between industries and utilities. The human factors involved showed to affect district heating collaborations more than anything else does. Particularly risk, imperfect and asymmetric information, credibility and trust, inertia and values are adequate variables when explaining the establishment or failure of industry-energy utility collaborations, while heterogeneity, access to capital and hidden costs appear to be of lower importance. A key conclusion from this study is that in an industry-energy utility collaboration, it is essential to nurture the business relationship. In summary, successful collaboration depends more on the individuals and organizations involved in the relationship between the two parties than on the technology used in the collaboration. 相似文献
15.
Seasonal storage of solar energy to supply the heat requirement of buildings in Edirne (41°39′54″N) has been examined experimentally. Solar energy has been stored in a cylindrical underground storage unit. Measurement values have been recorded per hour by means of a computerized recorder between July 2005 and May 2006. Monthly average temperature values of the heat storage unit and the surrounding ground have been calculated through the measurement results. The transient heat transfer which takes place between the heat storage unit and the surrounding ground has been calculated by means of the QuickField finite-element analysis program. It has been determined that the most significant deviations between the theoretical and the experimental temperature values turn out to be in question during the heating period. The annual solar fraction of the solar energy heating system has been determined as 53% for space heating and 85% for domestic water heating. 相似文献
16.
Finding the global optimal combination of the main components for a solar thermal energy system is an important topic in utilising solar radiation in a cost-effective way. However, selecting an optimal solar thermal system in a cold climate condition is a challenging task due to the dependency on the heat demand and the limited availability of solar radiation. This research presents several sets of optimum combinations of a solar thermal collector and a hot water storage tank regarding energy efficiency and the life cycle cost. Since domestic hot water consumption forms the significant part of the heat demand in new energy efficient apartment buildings, the applied consumption information were extracted precisely according to measured data. The solar thermal system with cost-optimal component sizes was able to save district heat energy consumption up 24% to 34% and made 4 €/m^2 to 23 €/m^2 in financial profit. 相似文献
17.
Napoleon Enteria Hiroshi Yoshino Rie Takaki Ryuichiro Yoshie Seizo Baba 《Solar Energy》2009,83(8):1300-1311
This paper reports the constructed combined solar thermal and electric desiccant cooling system - its initial operation and operational procedures. The system, as designed, can be operated during nighttime and daytime. The nighttime operation is for thermal energy storage using the auxiliary electric heater, while the daytime operation is for solar energy collection and desiccant cooling. Ongoing experimental evaluation is being undertaken to observe and determine the long-term performance of the system. 相似文献
18.
Temperature control systems based on solar and wind energy differ in two important ways from existing fossil fuel systems. One is that solar systems, at least active solar systems, all have some kind of energy storage, the other is that the source of energy in a solar and wind energy system is variable and uncontrollable. Because of these added complications and the high capital investment required for solar and wind energy systems, considerably more sophisticated techniques are required for the design of those systems. In this study, a new technique is applied to the optimal control problem of solar heating systems. 相似文献
19.
In this paper, a techno-economic model has been developed for a hybrid solar forced-convection water heating system. Two options of auxiliary energy use, viz. (A) an instant electric heater and (B) use of diesel as the auxiliary energy fuel, have been considered. Numerical calculations have been made for the climate of Delhi, India, corresponding to the two representative demand patterns, viz. (i) hot-water demand of big residential buildings and (ii) industrial hot-water demand. Taking into account the life, capital cost and the maintenance cost of the solar and auxiliary systems, the cost of useful energy has been calculated for different values of collector area and tank capacity. This exercise, thereby, yields the optimum values of collector area and tank capacity corresponding to the minimum cost of useful energy. The effect of government subsidy on the optimized values of collector area, tank capacity and cost of useful energy has also been investigated. 相似文献
20.
Timo Kalema 《国际能源研究杂志》1985,9(4):403-415
The energy saving obtainable with active solar heating and heat pumps has been studied for several years in the Northern climate of Finland. The studies deal mainly with small houses. A computer program is developed which calculates hour by hour the annual energy balance of different heating systems. The performance, of the heating systems are also measured in inhabited houses. The calculations show that the useful solar energy obtainable from the collector is 50–400 kWh/m2 annually depending on the system and the collector size. A heat pump in the system is very advantageous, because it keeps the heat losses low and the collector efficiency high. It approximately doubles the energy obtainable. The measurement results have not been as good as expected. The solar energy obtained from the collector has been 120–160 kWh/m2 annually. The main reasons for the low solar energy are design and equipment faults and the shading effects. The best energy saving device is the earth heat pump. It is also therefore very advantageous that the peak power demand decreases markedly. When the area of the earth pipes is large enough, energy may be extracted from earth through the whole year. The annual coefficient of performance is 2–3. Also a heat pump which extracts heat from exhaust air in dwelling houses has been very promising. 相似文献