首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
热泵系统也称余热回收系统,是使用部分驱动能源(如燃气、蒸汽、燃气或热水),将余热形式为地热水、冷却水、洗涤水或伴油污水,温度在20~70℃的低品位能量取出,转移到45~100℃的中高温热媒中的系统。热泵系统在利用低品位热能的同时,仅消耗少量电能,节能效果显著。我国直到20世纪90年代,开始大面积应用热泵技术。目前,在热泵制造、安装和运行规模上,已走到了国际前例。现在,不管是压缩式热泵,还是吸收式热泵,也不论是设备还是系统,其技术已经成熟,热泵机组制热温度达到45~100℃,COP值(能量与热量之间的转换比率,简称能效比)也达到相当高的水平,机组的超小型化和超大型化技术得到长足发展,被广泛应用到建筑、烘干、石油化工、医药、筑路等领域。以热泵工艺在油田注水站的应用为分析对象,针对热泵的起源、发展、工作原理及在注水站的应用展开论述,着重从初期投资、运行费用、人工费用、社会效益、节约清水及10年费用现值方面,对注水站采用热泵冷却工艺与常规冷却工艺进行对比分析,提出了注水站采用热泵工艺有利于提高注水站系统的热能效率,降低运行成本,减少加热炉加热过程中产生的废气和余热排放,实现节能减排,对于热泵工艺在大庆油田注水站的应用具有借鉴意义。  相似文献   

2.
Ground coupled heat pumps are attractive solutions for cooling and heating commercial buildings due to their high efficiency and their reduced environmental impact. Two possible ideas to improve the efficiency of these systems are decoupling energy generation from energy distribution and combining different HVAC systems. Based on these two ideas, we present several HVAC configurations which combine the following equipments: a ground coupled heat pump, an air to water heat pump and a thermal storage device. These HVAC configurations are linked to an office building in a cooling dominated area in order to evaluate in these conditions the total electrical consumption of each configuration to obtain which one satisfy the thermal demand more efficiently. The results of our simulations show that the electrical energy consumption obtained when the system employs a suitable configuration is of around the 60% compared with an HVAC system driven by an air to water heat pump and around the 82% compared with an HVAC system driven by a ground coupled heat pump.  相似文献   

3.
热泵原理及发展和供热经济性分析   总被引:1,自引:0,他引:1  
对热泵原理进行了阐述,介绍了热泵在我国的发展与应用,对热泵的技术性和热泵供热的经济性进行了分析,并与其它常用能源供热所需费用进行了综合的比较,提出了热泵技术在中国的发展前景和展望。  相似文献   

4.
Large district heating (DH) system accounts for 70% of urban building heating in China. In North China, this proportion is even higher (The North China is the north of the Huai River and Qinling Mountains). Many cities in North China can exploit various kinds of low-grade renewable energy. This paper presents a new heating method to realize renewable energy recovery by absorption heat pumps associated with municipal network. In the DH substations, absorption heat pumps are driven by the exergy-difference originated from the larger temperature difference of heat exchange between primary and secondary heat network. There are two configurations—type I and type II substations based on the temperature of renewable energy. A reasonable parameter setting of system is suggested. The equipment operational performance was optimized based on a practical example. The low-grade renewable energy can be recovered effectively in this method. As a result, both heating capacity and energy efficiency of the DH system can be improved. Furthermore, operating costs may be reduced remarkably, due to the reduction in both the coal consumption of heat production unit and the power consumption of delivery pump. Therefore, the system is superior in energy conservation and has a promising application prospect.  相似文献   

5.
Heat pumps have been spotlighted as efficient building energy systems because they have great potentials for energy reduction in building air conditioning and reducing CO2 emission. In this study, a multi-function heat pump which has the functions of heating, cooling, and hot water supply was designed and its performance was investigated according to operating modes. In the cooling-hot water mode, the capacity and COP were enhanced as compared to other modes because the waste heat from the outdoor heat exchanger was utilized as useful heat in the indoor heat exchanger. In the heating and hot water supply mode, the compressor speed should be increased to get appropriate heating and hot water capacities. For all operating modes, the system could be optimized by adjusting the superheat.  相似文献   

6.
水源热泵技术利用少量电能将地表水或地下水的低品位能量转移至高品位,目前正成为节能领域的研究热点.针对水源热泵变冷凝参数的相关研究缺乏的现状,通过搭建水源热泵热水器实验台进行了相应实验研究.在水流量Q为0.7~1.3 m~3·h~(-1),进水温度t为15~30℃范围内,对系统功耗、制热量、制冷量、热泵性能系数COP等参数进行了测量.实验结果表明,在水流量为1.1 m~3·h~(-1),进水温度为20℃时,COP达到最大值,系统平均热泵性能系数COP_(ave)为3.23,此时系统处于最佳运行工况.由此可知,寻找系统的最佳运行工况对热泵系统设计和实际工程应用具有重要的意义.  相似文献   

7.
Geothermal Heat Pumps, or Ground Coupled Heat Pumps (GCHP), are systems combining a heat pump with a ground heat exchanger (closed loop systems), or fed by ground water from a well (open loop systems). They use the earth as a heat source when operating in heating mode, with a fluid (usually water or a water–antifreeze mixture) as the medium that transfers the heat from the earth to the evaporator of the heat pump, thus utilising geothermal energy. In cooling mode, they use the earth as a heat sink. With Borehole Heat Exchangers (BHE), geothermal heat pumps can offer both heating and cooling at virtually any location, with great flexibility to meet any demands. More than 20 years of R&D focusing on BHE in Europe has resulted in a well-established concept of sustainability for this technology, as well as sound design and installation criteria. Recent developments are the Thermal Response Test, which allows in-situ-determination of ground thermal properties for design purposes, and thermally enhanced grouting materials to reduce borehole thermal resistance. For cooling purposes, but also for the storage of solar or waste heat, the concept of underground thermal energy storage (UTES) could prove successful. Systems can be either open (aquifer storage) or can use BHE (borehole storage). Whereas cold storage is already established on the market, heat storage, and, in particular, high temperature heat storage (> 50 °C) is still in the demonstration phase. Despite the fact that geothermal heat pumps have been in use for over 50 years now (the first were in the USA), market penetration of this technology is still in its infancy, with fossil fuels dominating the space heating market and air-to-air heat pumps that of space cooling. In Germany, Switzerland, Austria, Sweden, Denmark, Norway, France and the USA, large numbers of geothermal heat pumps are already operational, and installation guidelines, quality control and contractor certification are now major issues of debate.  相似文献   

8.
地源热泵是一种利用土壤所储藏的太阳能资源作为冷热源进行能量转换的供暖制冷空调系统,通过输入少量的高品位能源(如电力、机械功、燃气和液体燃料),实现热量从低温热源向高温热源的转移.以上海某小型别墅为对象,设计了一套家用地源热泵空调系统.首先计算了夏季冷负荷和冬季热负荷,然后根据冷、热负荷选择一套水源热泵机组(MWH080CR型机组)和相应的风机盘管,进行了室内水管环路系统、土壤热交换器和地板采暖的设计选型,最后对系统的能效比进行了计算.结果表明,该空调系统具有节能环保、稳定可靠、舒适耐用等优点.  相似文献   

9.
根据上海的气候条件,以上海地区某写字楼为对象,提出4种太阳能驱动的溴化锂吸收式与电动蒸汽压缩式热泵联合制冷与供暖系统。这4种系统分别由热管式真空管集热器或抛物面槽形聚光集热器,单效或双效溴化锂吸收式制冷机,以及风冷热泵或水源热泵构成。分析比较这4种系统的节能型和经济性的结果表明,采用抛物面槽形聚光集热器+双效溴化锂吸收式制冷机+风冷热泵组成的系统,同时具备较好的节能性与经济性,一次能源利用率可降低约50%。  相似文献   

10.
胡先芳  李玉云  马勇  胡贵华  赵亚洲 《节能技术》2012,30(4):353-356,365
通过对某办公楼地源热泵系统的短期测试与长期监测,分析了影响系统能效的主要因素,得出了该热回收热泵机组的部分负荷制冷性能系数低于额定工况下的制冷性能系数,热泵系统能效比略高于常规机组系统能效比下限值2.4,得出了夏热冬冷地区实际累计采暖+卫生热水热负荷大于累计冷负荷,增量成本的实际回收期高于预测回收期。建议夏热冬冷地区采用三工况(制冷、制热、热回收)地源热泵系统,可不设辅助冷却系统。  相似文献   

11.
The ground-water heat-pump system (GWHP) provides a high efficient way for heating and cooling while consuming a little electrical energy. Due to the lack of scientific guidance for operating control strategy, the coefficient of performance (COP) of the system and units are still very low. In this paper, the running strategy of GWHP was studied. First, the groundwater thermal transfer calculation under slow heat transfixion and transient heat transfixion was established by calculating the heat transfer simulation software Flow Heat and using correction factor. Next, heating parameters were calculated based on the building heat load and the terminal equipment characteristic equation. Then, the energy consumption calculation model for units and pumps were established, based on which the optimization method and constraints were established. Finally, a field test on a GWHP system in Beijing was conducted and the model was applied. The new system operation optimization idea for taking every part of the GWHP into account that put forward in this paper has an important guiding significance to the actual operation of underground water source heat pump.  相似文献   

12.
X. YuR.Z. Wang  X.Q. Zhai 《Energy》2011,36(2):1309-1318
Numerous studies about the ground source heat pump building heating and cooling systems have been constructed in office building, hotel, residential building and school et al. However, few researches about the constant temperature and humidity air-conditioning system driven by ground-coupled heat pumps were carried out. In this paper, a constant temperature and humidity air-conditioning system driven by ground source heat pump was designed and constructed in an archives building in Shanghai, China. During the operation in the cooling mode, the heat extraction from the condenser of the heat pump was divided: part was rejected to the soil while another was used to reheat the air in AHUs. According to the experimental results, the indoor temperature and relative humidity fulfilled the “Archives Design Code”. In summer, the heat rejected to the soil was reduced by 32%, which was helpful for the earth energy conservation. The soil temperature increased only 0.5 °C after the GSHP system operating for a year. The energy cost of the air-conditioning system was 56.1 kWh/m2. Compared with air source heat pump system and water cooled unit with boiler system, the operating cost of ground source heat pump was reduced by 55.8% and 48.4%, respectively.  相似文献   

13.
The energy needs of a typical one-family house in the Thessaloniki area for heating, cooling and domestic hot water production are calculated. The calculations are based on the typical average daily consumption of hot water and on the degree-day method for heating and cooling. The results are finally translated into thermal energy consumption, assuming the typical Greek situation (heating with diesel oil boilers and conventional radiators, cooling with local air-to-air split-type heat pumps and hot water production with electric heaters). The same energy needs are assumed to be covered by a vertical closed loop ground heat exchanger combined with a water-to-water heat pump system with fan-coils for heating and cooling and a thermosyphonic solar system for domestic hot water production. The ground heat exchanger/heat pump system efficiency is determined using data from an existing and continuously monitored similar system installed in the broader area of Thessaloniki. The solar system load coverage is calculated using the f-chart method. The energy consumption of the renewable energy systems is calculated and compared to that of the conventional system. The results prove that significant energy savings can be achieved.  相似文献   

14.
The main solution for the reduction of energy consumption in the field of HVAC is the development of new and renewable energy technologies. Among the various renewable energy systems, ground source heat pump (GSHP) systems have been spotlighted as efficient building energy systems because of their great potentials for energy reduction in building air conditioning and reducing CO2 emissions. However, higher initial cost works as a barrier to the promotion of their use. Therefore, it is critical to reduce the initial costs by optimizing the design of the system. In this paper, parameters that affect the performance of the GSHP system and the size of ground loop heat exchanger (GLHX) have been investigated. Ratio of GLHX length to unit capacity (L/Q) decreased according to increasing value of thermal conductivity, but L/Q increased according to increasing value of borehole heat transfer resistance. In cooling mode, L/Q decreased according to increasing EWT of underground circulating water and borehole distance but increased in heating mode. The value of L/Q tended to increase according to increasing underground initial temperature in cooling mode, but decreased in heating mode. L/Q decreased according to increasing U-tube separation distance and decreasing underground circulating water flow rate, because the thermal interference effect of underground circulating water and heat absorption and emission rate from the ground decreased. The reduction of the size of GLHX is very important in the aspect of saving total installation cost of a GSHP system. Therefore, the size of GLHX and the performance of GSHP system should be considered together for optimum design of the GSHP system.  相似文献   

15.
Heat pump systems are recognized to be outstanding heating, cooling and water heating systems. They provide high levels of comfort as well as offering significant reductions in electrical energy use. In addition, they have very low levels of maintenance requirements and are environmentally attractive. The purpose of this study is to evaluate the experimentally performance and energy analysis of vertical ground-source heat pump (GSHP) for winter climatic condition of Erzurum, Turkey. For this aim, an experimental analysis was performed on GSHP system made up in the Energy Laboratory in the campus of Ataturk University. The experimental apparatus consisted of a ground heat exchanger, the depth of which was 53 m, a liquid-to-liquid vapor compression heat pump, water circulating pumps and other measurement and control equipments. Tests were performed under laboratory conditions for space heating, in which experimental results were obtained during January–May within the heating season of 2007. The experimentally obtained results were used to calculate the heat pump coefficient of performance (COP) and the system performance (COPs). The COP and COPs were found to be in the range of 2.43–3.55 and 2.07–3.04, respectively. This study also shows that the system proposed could be used for residential heating in the province of Erzurum which is one of the coldest climate region of Turkey.  相似文献   

16.
In this paper, we deal with the energy and exergy analysis of a fossil plant and ground and air source heat pump building heating system at two different dead-state temperatures. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for heat pump building heating system. Since energy and exergy demand are key parameters to see which system is efficient at what reference temperature, we did a study on the influence of energy and exergy efficiencies. In this regard, a commercial software package IDA-ICE program is used for calculation of fossil plant heating system, however, there is no inbuilt simulation model for heat pumps in IDA-ICE, different COP (coefficient of performance) curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy. The outcome of the energy and exergy flow analysis at two different dead-state temperatures revealed that the ground source heat pumps with ambient reference have better performance against all ground reference systems as well as fossil plant (conventional system) and air source heat pumps with ambient reference.  相似文献   

17.
The energy and exergy flow for a space heating systems of a typical residential building of natural ventilation system with different heat generation plants have been modeled and compared. The aim of this comparison is to demonstrate which system leads to an efficient conversion and supply of energy/exergy within a building system.The analysis of a fossil plant heating system has been done with a typical building simulation software IDA–ICE. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for other cases of building heating systems where power generation plants are considered as ground and air source heat pumps at different operating conditions. Since there is no inbuilt simulation model for heat pumps in IDA–ICE, different COP curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy.The outcome of the energy and exergy flow analysis revealed that the ground source heat pump heating system is better than air source heat pump or conventional heating system. The realistic and efficient system in this study “ground source heat pump with condenser inlet temperature 30 °C and varying evaporator inlet temperature” has roughly 25% less demand of absolute primary energy and exergy whereas about 50% high overall primary coefficient of performance and overall primary exergy efficiency than base case (conventional system). The consequence of low absolute energy and exergy demands and high efficiencies lead to a sustainable building heating system.  相似文献   

18.
Heat pumps play a central role in decarbonising the UK's buildings sector as part of the Committee on Climate Change's (CCC) updated abatement scenario for meeting the UK's fourth carbon budget. However, the UK has one of the least developed heat pump markets in Europe and renewable heat output from heat pumps will need to increase by a factor of 50 over the next 15 years to be in line with the scenario. Therefore, this paper explores what lessons the UK might learn from Finland to achieve this aim considering that its current level of heat pump penetration is comparable with that outlined in the CCC scenario for 2030. Despite the two countries’ characteristic differences we argue they share sufficient similarities for the UK to usefully draw some policy-based lessons from Finland including: stimulating new-build construction and renovation of existing stock; incorporating renewable heat solutions in building energy performance standards; and bringing the cost of heat pumps in-line with gas fired heating via a combination of subsidies, taxes and energy RD&D. Finally, preliminary efforts to grow the heat pump market could usefully focus on properties unconnected to the gas-grid, considering these are typically heated by relatively expensive oil or electric heating technologies.  相似文献   

19.
A method of improving the performance of heat pumps for domestic space heating has been investigated. The study focuses on the short-term storage of heat pump output energy in concrete floor panels. This paper describes the dynamic computer simulation of an air to water heat pump, a floor panel energy store and energy flowpaths in a dwelling. The heating plant, controls and building thermal behaviour, were simulated as a complete energy system to enable the study of interactions between the subsystems. The model heating system comprised a number of under floor water heated panels installed in ground floor rooms of a two storey dwelling. Supplementary energy was supplied by direct electric heaters situated in most rooms. Heat pump operating periods were controlled as a function of the external air temperature within two prescribed occupancy intervals per day. Results of the investigation indicate that a heat pump system using floor panel storage and emission may be efficiently managed to provide nearly continuous heating with little supplementary energy input. The short-term storage of energy in thick floor panels allowed the heat pump to be operated for extended periods without cycling. Because of this, the seasonal loss in heat pump performance resulting from intermittent operation was less than 1 per cent. Attempting to supply the total space heating load with the heat pump and floor panel system resulted in severe overheating during periods of high solar or casual gain. Under these conditions the simple control strategy based on the measurement of external air temperature was ineffective. This problem was eliminated by reducing the heat pump energy input to the dwelling and supplying about 10 per cent of the seasonal energy demand by direct electric heaters. The influence of floor panel energy storage capacity on the performance of the heating system was investigated. Concrete panel depths of between 25 and 150 mm were considered. The seasonal system efficiency was found to increase with floor panel thickness, although not significantly with panel depths beyond 100 mm. The extensive use of floor slabs to store energy caused mean floor temperatures to be higher than when using direct electric air heaters only. However, with the depth of under floor insulation considered in the study (75 mm), heating the floor slab increased the seasonal energy loss of the building by only 4 per cent.  相似文献   

20.
高云龙 《中外能源》2010,15(9):110-112
大庆油田处于亚寒地带,为了降低冬季采暖能耗,开展了水源热泵采暖试验。水源热泵机组由蒸发器、冷却器、压缩机和膨胀阀4部分组成,引入热力学中的逆卡语循环原理,具备冬季制热和夏季制冷两种功能。水源热泵热源介质采用油田注水站内的低温回注污水,该介质具有温度较高、水源稳定、不影响生产运行的优点。利用水源热泵技术,冬季把污水中蕴含的热能"提取"出来,供室内采暖需要;夏季把压缩机工作时产生的热能"释放"到污水中,通过热泵机组制取冷冻水,供室内降温和注水泵电机冷却需要。现场应用表明,与电采暖系统相比,水源热泵技术一个采暖期内可实现节电12.7×104kW·h,创造经济效益6.9万元。同时,热泵机组具有的夏季制冷功能,既改善了工作环境,又解决了注水泵机组运行温度偏高的问题。  相似文献   