首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The protein toxin ricin, which originates from the seeds of Ricinus communis plants, has been the subject of increased interest, due to its potential terrorist use. Exceptionally, this toxin is also subject to the Chemical Weapons Convention. In this paper, it is shown that mass spectrometry can be used to unambiguously verify the presence of ricin in crude toxin preparations. It is demonstrated that MALDI MS can be used for screening, either by direct analysis or by trypsin digestion and peptide mapping. Purified ricin from several varieties of R. communis was characterized by LC-ES MS(/MS). A crude ricin preparation from a single bean was similarly characterized. An LC method was set up with product ion MS/MS detection of selected marker peptides specific for ricin: T5, T7, T11, T12, and T13 from the A-chain and T3, T5, T14, T19, and T20 from the B-chain. This method was then used to unambiguously identify ricin in a crude preparation of ricin. The MALDI MS molecular weight analysis and the marker peptides LC-ES MS/MS analysis give a forensic level of identification of ricin when combined with activity testing.  相似文献   

2.
Off-site analysis of chemical warfare agents (CWAs) and related compounds plays a key role in the verification program of the Chemical Weapons Convention (CWC). The analysis results, aiming toward unambiguous identication of compounds, depend on the type of sample preparation method. Development of milder sample preparation methods, which offer good recoveries and do not alter the structure of analytes, is highly desirable. Organic liquid with high hydrocarbon background is a frequently encountered challenge in off-site analysis and in official proficiency tests conducted by OPCW. Sample cleanup procedures, namely, solvent exchange followed by cooling and liquid-liquid extraction were studied to eliminate the hydrocarbons from organic liquid. Acetonitrile, a polar aprotic solvent, was effectively used to remove the background in both methods, and recoveries of spiked CWAs by the two techniques were between 69 and 99%.  相似文献   

3.
xMAP technology was used for simultaneous identification of six protein toxins (staphylococcal enterotoxins A and B, cholera toxin, ricin, botulinum toxin A, and heat labile toxin of E. coli). Monoclonal antibody-conjugated xMAP microspheres and biotinilated monoclonal antibodies were used to detect the toxins in a sandwich immunoassay format. The detection limits were found to be 0.01 ng/mL for staphylococcal enterotoxin A, cholera toxin, botulinum toxin A, and ricin in model buffer (PBS-BSA) and 0.1 ng/mL for staphylococcal enterotoxin B and LT. In a complex matrix, such as cow milk, the limits of detection for staphylococcal enterotoxins A and B, cholera toxin, botulinum toxin A, and ricin increased 2- to 5-fold, while for LT the detection limit increased 30-fold in comparison with the same analysis in PBS-BSA. In the both PBS-BSA and milk samples, the xMAP test system was 3-200 times (depending on the toxin) more sensitive than ELISA systems with the same pairs of monoclonal antibodies used. The time required for a simultaneous analysis of six toxins using the xMAP system did not exceed the time required for ELISA to analyze one toxin. In the future, the assay may be used in clinical diagnostics and for food and environmental monitoring.  相似文献   

4.
Multiplexed toxin analysis using four colors of quantum dot fluororeagents   总被引:1,自引:0,他引:1  
Quantum dots (QDs) have the potential to simplify the performance of multiplexed analysis. In this work, we prepared bioinorganic conjugates made with highly luminescent semiconductor nanocrystals (CdSe-ZnS core-shell QDs) and antibodies to perform multiplexed fluoroimmunoassays. Sandwich immunoassays for the detection of cholera toxin, ricin, shiga-like toxin 1, and staphylococcal enterotoxin B were performed simultaneously in single wells of a microtiter plate. Initially the assay performance for the detection of each toxin was examined. We then demonstrated the simultaneous detection of the four toxins from a single sample probed with a mixture of all four QD-antibody reagents. Using a simple linear equation-based algorithm, it was possible to deconvolute the signal from mixed toxin samples, which allowed quantitation of all four toxins simultaneously.  相似文献   

5.
Biological membrane-like lipid films were deposited on the sensing surface in an optical biosensor instrument. The membranes were mixtures of biologically occurring lipids. Eight surfaces were prepared, some of which contained various glycolipids as minor components. One was supplemented with membrane proteins. The binding of six protein toxins (cholera toxin, cholera toxin B subunit, diphtheria toxin, ricin, ricin B subunit, staphylococcal enterotoxin B) and of bovine serum albumin at pH 7.4 and pH 5.2 to each of the sensor surfaces was studied. Each of the seven proteins gave a distinct binding pattern. The assay is rapid and simple, with no need for reagents. The lipid sensor surface is readily regenerated after binding and very stable. The concept with mixed lipid layers and assays at different pHs gives numerous combinations and could be applicable for developing a sensor for protein toxins.  相似文献   

6.
Under the unmet need of efficient tumor‐targeting drugs for oncology, a recombinant version of the plant toxin ricin (the modular protein T22‐mRTA‐H6) is engineered to self‐assemble as protein‐only, CXCR4‐targeted nanoparticles. The soluble version of the construct self‐organizes as regular 11 nm planar entities that are highly cytotoxic in cultured CXCR4+ cancer cells upon short time exposure, with a determined IC50 in the nanomolar order of magnitude. The chemical inhibition of CXCR4 binding sites in exposed cells results in a dramatic reduction of the cytotoxic potency, proving the receptor‐dependent mechanism of cytotoxicity. The insoluble version of T22‐mRTA‐H6 is, contrarily, moderately active, indicating that free, nanostructured protein is the optimal drug form. In animal models of acute myeloid leukemia, T22‐mRTA‐H6 nanoparticles show an impressive and highly selective therapeutic effect, dramatically reducing the leukemia cells affectation of clinically relevant organs. Functionalized T22‐mRTA‐H6 nanoparticles are then promising prototypes of chemically homogeneous, highly potent antitumor nanostructured toxins for precise oncotherapies based on self‐mediated intracellular drug delivery.  相似文献   

7.
The toxin ricin is a biological weapon that may be used for bioterrorist purposes. As a member of the group of ribosome-inactivating proteins (RIPs), ricin has an A-chain possessing N-glycosidase activity which irreversibly inhibits protein synthesis. In this paper, we demonstrate that provided appropriate sample preparation is used, this enzymatic activity can be exploited for functional ricin detection with sensitivity similar to the best ELISA and specificity allowing application to environmental samples. Ricin is first captured by a monoclonal antibody directed against the B chain and immobilized on magnetic beads. Detection is then realized by determination of the adenine released by the A chain from an RNA template using liquid chromatography coupled to tandem mass spectrometry. The immunoaffinity step combined with the enzymatic activity detection leads to a specific assay for the entire functional ricin with a lower limit of detection of 0.1 ng/mL (1.56 pM) after concentration of the toxin from a 500 microL sample size. The variability of the assay was 10%. Finally, the method was applied successfully to milk and tap or bottled water samples.  相似文献   

8.
A 1.7-mm microcoil probe head was tested in the analysis of organophosphorus compounds related to the Chemical Weapons Convention. The microcoil probe head demonstrated a high mass sensitivity in the detection of traces of organophosphorus compounds in samples. Methylphosphonic acid, the common secondary degradation product of sarin, soman, and VX, was detected at level 50 ng (0.52 nmol) from a 30-microL water sample using proton-observed experiments. Direct phosphorus observation of methylphosphonic acid with (31)P{(1)H} NMR experiment was feasible at the 400-ng (4.17 nmol) level. Application of the microcoil probe head in the spiked sample analysis was studied with a test water sample containing 2-10 microg/mL of three organophosphorus compounds. High-quality (1)H NMR, (31)P{(1)H} NMR, 2D (1)H-(31)P fast-HMQC, and 2D TOCSY spectra were obtained in 3 h from the concentrated 1.7-mm NMR sample prepared from 1 mL of the water solution. Furthermore, a 2D (1)H-(13)C fast-HMQC spectrum with sufficient quality was possible to measure in 5 h. The microcoil probe head demonstrated a considerable sensitivity improvement and reduction of measurement times for the NMR spectroscopy in identification of chemicals related to the Chemical Weapons Convention.  相似文献   

9.
A thermal desorption GC/MS technique has been developed for the quantification of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter using the NIST Standard Reference Material (SRM1649a) Urban Dust. The technique was developed using standard linearity tests in order to establish optimum sample weights and optimum desorption and chromatographic parameters. This direct analysis technique eliminates the use of solvents in the sample preparation (reducing volatile component losses) and also significantly reduces the sample preparation time (no extraction procedure). The technique has been shown to give linearity in terms of the overall TIC response as well as for a prominent series of n-alkanes (C20-C33) and 10 NIST priority PAHs, 8 of which have been quantified. The technique is reported to be uniquely sensitive (PAH concentrations 2-6 mg kg(-1)) and reproducible (MW = 178-228 SD < or =0.228 mg kg(-1), < or =7%; MW = 252 SD < or =0.922 mg kg(-1), < or =33%) over the range of sample weights (1-5 mg). Such sample weights illustrate that the technique can be equally applied to the analysis of airborne particulate samples collected over short time periods (24-48 h) using only commonly used low-volume collection devices.  相似文献   

10.
Two-dimensional 1H-31P Fast-HMQC was tested for determination of the presence in low concentrations of organophosphorus compounds related to the Chemical Weapons Convention. This method, based on inverse detection, demonstrated high sensitivity and selectivity. Background signals, such as solvent peaks, are suppressed with good efficiency, and organophosphorus compounds present at a concentration level 1-10 microg/mL can be detected within a few hours. In addition, phosphorus-selective one-dimensional 1H-31P HSQC-TOCSY was applied to produce a complete proton spectrum of selected organophosphorus compound from a sample containing intense background resonances. Application of the methods presented in this paper resulted in considerably improved performance of NMR spectroscopy as a complementary technique for screening as well as identification of chemical warfare agents in environmental samples.  相似文献   

11.
Toxin profiles of representative ciguatera species caught at different locations of Japan were investigated in fish flesh by high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. Identification and quantification of 16 toxins were facilitated by the use of 14 reference toxins prepared by either synthesis or isolation from natural sources and the previous LC-MS data thereof. Sodium adduct ions [M + Na](+) were used as parent and product ions. Distinct regional differences were unveiled: ciguatoxin-1B type toxins were found in snappers and groupers from Okinawa, ciguatoxin-3C type toxins were found in a spotted knifejaw, Oplegnathus punctatus, from Miyazaki located 730 km north of Okinawa, and both types of toxins were found in a red snapper, Lutjanus bohar, from Minamitorishima (Marcus) Island. Twelve toxins were identified in a dinoflagellate, Gambierdiscus toxicus, collected as the primary toxin source in French Polynesia. Occurrence of M-seco-toxins in fish and oxidized toxins in the dinoflagellate was confirmed for the first time. The present LC-MS/MS method is rapid, specific, and accurate. It not only outperforms the currently employed mouse bioassays but also enables the study of the toxin dynamics during the food chain transmission.  相似文献   

12.
Can quantum dots (Qdots) act as relevant intracellular probes to investigate routing of ligands in live cells? The intracellular trafficking of Qdots that were coupled to the plant toxin ricin, Shiga toxin, or the ligand transferrin (Tf) was studied by confocal fluorescence microscopy. The Tf:Qdots were internalized by clathrin-dependent endocytosis as fast as Tf, but their recycling was blocked. Unlike Shiga toxin, the Shiga:Qdot bioconjugate was not routed to the Golgi apparatus. The internalized ricin:Qdot bioconjugates localized to the same endosomes as ricin itself but could not be visualized in the Golgi apparatus. Importantly, we find that the endosomal accumulation of ricin:Qdots affects endosome-to-Golgi transport of both ricin and Shiga toxin: Transport of ricin was reduced whereas transport of Shiga toxin was increased. In conclusion, the data reveal that, although coupling of Qdots to a ligand does not necessarily change the endocytic pathway normally used by the ligands studied, it appears that the ligand-coupled Qdot nanoparticles can be arrested within endosomes and somehow perturb the normal endosomal sorting in cells. Thus, the results demonstrate that Qdots may have severe consequences on cell physiology.  相似文献   

13.
Retrospective detection and identification of chemical warfare agents (CWAs) is important from the verification point of view of the Chemical Weapons Convention. In the present work, a novel method for determination of CWAs and their markers in water has been described. It is based on a single drop micro extraction (SDME) of analytes and gas chromatography/mass spectrometric identification. Extraction conditions, such as solvent selection, agitation, extraction time, and salt content, were found to have significant influence on SDME. The conditions optimized for extraction of CWAs were 1 microL CH2Cl2/CCl4 (3:1 v/v), 30-min extraction time, 300-rpm stirring rate, and with or without NaCl addition. Under optimized conditions, comparison of SDME, solid-phase microextraction, and liquid-liquid extraction was also made. The limit of detection by SDME ranged from 75 to 10 microg L(-1) at a signal-to-noise ratio of 10:1.  相似文献   

14.
A mini ball mill (MBM) solvent-free matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method allows for the analysis of bacteriorhodopsin (BR), an integral membrane protein that previously presented special analytical problems. For well-defined signals in the molecular ion region of the analytes, a desalting procedure of the MBM sample directly on the MALDI target plate was used to reduce adduction by sodium and other cations that are normally attendant with hydrophobic peptides and proteins as a result of the sample preparation procedure. Mass analysis of the intact hydrophobic protein and the few hydrophobic and hydrophilic tryptic peptides available in the digest is demonstrated with this robust new approach. MS and MS/MS spectra of BR tryptic peptides and intact protein were generally superior to the traditional solvent-based method using the desalted "dry" MALDI preparation procedure. The solvent-free method expands the range of peptides that can be effectively analyzed by MALDI-MS to those that are hydrophobic and solubility-limited.  相似文献   

15.
Glycosphingolipids (GSLs) have been shown to undergo strong interactions with a number of protein toxins, including potential bioterrorism agents such as ricin and botulinum neurotoxin. Characterization of this interaction in recent years has led to a number of studies where GSLs were used as the recognition molecules for biosensing applications. Here, we offer a comparison of quartz crystal microbalance (QCM) sensors for the detection of ricin using antibodies and the GSLs GM1 and asialoGM1, which have been shown to undergo strong interactions with ricin. The presence, orientation, and activity of the GSL and antibody films were confirmed using ellipsometry, Fourier transform infrared spectroscopy (FT-IR), and QCM. It was found that the GSLs offered more sensitive detection limits when directly compared with antibodies. Both GSLs had lower detection limits at 5 microg/mL, approximately 5 times lower than were found for antibodies (25 microg/mL), and their linear detection range extended to the highest concentrations tested (100 microg/mL), almost an order of magnitude beyond the saturation point for the antibody sensors. Potential sites for nonspecific adsorption were blocked using serum albumin without sacrificing toxin specificity.  相似文献   

16.
Chen Y  Kim SC  Zhao Y 《Analytical chemistry》2005,77(24):8179-8184
The high sensitivity and accuracy of mass spectrometry for identifying proteins has led to an explosive expansion of proteomics research, necessitating rapid procedures for HPLC/MS/MS analysis. Current HPLC/MS/MS analysis usually relies on elution of peptides from the HPLC column with a gradient that takes a total of 45-70 min for each cycle, limiting sample throughput and the speed of protein identification. Here we report a simple method for high-throughput protein identification, using isocratic, either methanol- or acetonitrile-based buffer systems, HPLC elution into an LTQ mass spectrometer. This procedure allows each cycle of highly sensitive HPLC/MS/MS analysis to be completed in 5 min, thus boosting the efficiency of HPLC/MS/MS analysis 9-14-fold. Using this method, each operator can acquire HPLC/MS/MS data for 96 in-gel proteolytic digests in one 8-h working day. The method can easily be implemented in any laboratory with an LTQ mass spectrometer. This protocol should find wide application in mass spectrometry laboratories that require high-throughput analysis but are limited by inefficient use of machine time.  相似文献   

17.
A LC/MS method for the determination of cyanobacteria toxins in water   总被引:3,自引:0,他引:3  
The cyanobacteria toxins anatoxin-a, microcystin-LR, microcystin-RR, microcystin-YR, and nodularin were separated in less than 30 min on several 1 mm x 15 cm reversed-phase liquid chromatography (LC) columns, and their electrospray mass spectra were measured using injections of 50 ng or less with a benchtop time-of-flight (TOF) mass spectrometer. New data from this work include the following: (a) the impact of acetic acid concentrations in the methanol-water mobile phase on measured ion abundances; (b) the performance of the electrospray-TOF mass spectrometer as an LC detector; (c) the accuracy and precision of exact m/z measurements after LC separation with a routinely used mass spectrometer resolving power of 5000; and (d) recoveries of the five toxins from reagent water, river waters, and sewage treatment plant effluent samples extracted with C-18 silica particles enmeshed in thin Teflon membrane filter disks. This technique has the potential of providing a relatively simple and reasonable-cost sample preparation and LC/MS method that provides the sensitivity, selectivity, reliability, and information content needed for source and drinking water occurrence and human exposure studies.  相似文献   

18.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

19.
Two types of biotin-tagged glycopolymers carrying lactose or glucose in clusters along the polyacrylamide backbone were prepared and subjected to decontamination analyses with the plant toxin ricin. A buffer solution containing the toxin was treated with one glycopolymer followed by streptavidin-magnetic particles. Supernatant solutions were analyzed with surface plasmon resonance and capillary electrophoresis, and revealed that the lactose glycopolymer "captured" this toxin more effectively than the glucose polymer. Free toxin was not detectable in the supernatant after treatment with the glycopolymer and magnetic particles; >99% decontamination was achieved for this potentially fatal biological toxin.  相似文献   

20.
Antivirulence vaccination is a promising strategy for addressing bacterial infection that focuses on removing the harmful toxins produced by bacteria. However, a major challenge for creating vaccines against biological toxins is that the vaccine potency is often limited by lack of antigenic breadth, as most formulations have focused on single antigens, while most bacteria secrete a plethora of toxins. Here, a facile approach for generating multiantigenic nanotoxoids for use as vaccines against pathogenic bacteria by leveraging the natural affinity of virulence factors for cellular membranes is reported. Specifically, multiple virulent toxins from bacterial protein secretions are concurrently and naturally entrapped using a membrane‐coated nanosponge construct. The resulting multivalent nanotoxoids are capable of delivering virulence factors together, are safe both in vitro and in vivo, and can elicit functional immunity capable of combating live bacterial infections in a mouse model. Despite containing the same bacterial antigens, the reported nanotoxoid formulation consistently outperforms a denatured protein preparation in all of the metrics studied, which underscores the utility of biomimetic nanoparticle‐based neutralization and delivery. Overall this strategy helps to address major hurdles in the design of antivirulence vaccines, enabling increased antigenic breadth while maintaining safety.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号