首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 234 毫秒
1.
采用两套相同的EGSB反应器,分别接种厌氧颗粒污泥和好氧活性污泥,在温度(35±1)℃、水力停留时间6 h、上升流速为4 m/h的条件下,通过低浓度基质模拟废水进行驯化启动厌氧氨氧化,考察驯化启动厌氧氨氧化反应变化的特性以及基质浓度梯度提升和基质比对驯化系统运行的影响特性。结果表明:接种厌氧颗粒污泥和好氧活性污泥分别经过93 d和63 d后成功驯化启动了厌氧氨氧化,并经过容积TN负荷提升达到1.76 kgN/(m3·d),TN去除率均值分别达到了83%和81%;当进水基质比为1.32时,接种厌氧颗粒污泥组的NH4+-N去除量∶NO2--N去除量∶NO3--N产生量为1∶1.24∶0.15,低于理论值1∶1.32∶0.26,而接种好氧活性污泥组的为1∶1.33∶0.17接近理论值。  相似文献   

2.
近年来,水体富营养化引起的水环境安全事件频发。总氮(TN)是引起水体富营养化的其中一个关键因素,废水脱氮处理能够有效减少TN的排放。研究采用序批式反应器(SBR),通过控制曝气量,建立溶解氧(DO)低于0.01 mg/L的表观厌氧环境,成功启动并维持了短程硝化及同步反硝化。低氨氮进水(80 mg/L)下,氨氮氧化率和亚硝酸盐氮(NO2--N)转化率分别为99%和94%;高氨氮进水(160 mg/L)下,氨氮氧化率和NO2--N转化率分别为98%和88%。比较分析发现,进水碳氮比(C/N)为2∶1时,短程硝化同步反硝化具有最高的成本效益,TN去除率和出水氨氮平均质量浓度分别约为50%和4.8 mg/L,去除1 g TN实际消耗4.94 g碱度(以CaCO3计)。  相似文献   

3.
为提高人工快渗(CRI)系统的脱氮性能,构建了好氧(O)/缺氧(A)两段式CRI系统处理模拟生活污水,采用NaCl-pH协同调控的方式启动短程硝化反硝化,考察了其对NH4+-N、TN去除的强化效果。结果表明,进水中投加质量浓度为6 000 mg/L的NaCl运行13 d后,O-CRI反应柱的NO2--N积累率可达到71.7%,此时提高进水pH至8.8,NO2--N积累率可增高至95.5%,NaCl-pH协同调控可成功启动短程硝化。O/A-CRI系统稳定运行期间NH4+-N、TN去除率均值分别达到97.6%、87.5%,比对照组分别提高了2.9、41.3个百分点。O-CRI反应柱内的脱氮功能菌以氨氧化菌(AOB)为主,其中相对丰度较高的菌属为Nitrosomonas、Nitrosospira,而以Nitrospira为代表的亚硝酸盐氧化菌(NOB)的活性由于被选择性抑制而致使其相对丰度大幅减小,从而保障了NO  相似文献   

4.
针对传统人工湿地脱氮效率低,构建了潮汐-垂直流和垂直潜流人工湿地,对二级好氧单元出水进行深度脱氮。结果表明,潮汐-垂直流和垂直潜流人工湿地分别对 NH4+-N 和 NO3--N 去除效果较好,其平均去除率分别为 79.92% 和72.45%,且后者出水 TN 浓度低于城镇污水处理厂污染物排放标准一级 A 标准限值,但 NH4+-N 则未能达标。增大进水C/N 比均显著提升了两系统对 TN 的去除效率(p<0.005)。两系统上层填料对 NH4+-N 的去除贡献均超过 75%,同时对TN 和 COD 的去除贡献也最高,表明上层填料在污染物去除过程中发挥了主导作用。完全氨氧化细菌(相对丰度为1.87%)和潜在硝化菌 Rudaea(相对丰度为 0.58%)分别是潮汐-垂直流和垂直潜流人工湿地上层填料主导的氨氧化菌,而Rhodanobacter和Denitratisoma以及norank_c_OLB14和Denit...  相似文献   

5.
为解决实际低碳氮比废水高效脱氮问题,以MBR-MBfR双膜耦合系统为研究对象,探究不同C/N双膜系统的脱氮效果。结果表明,当C/N=2时,其对NO3--N、NH4+-N、TN及COD的协同去除效果最好,COD、NO3--N、NO2--N、NH4+-N、TN的去除率分别达到79.16%、78.40%、88.41%、77.04%和77.31%,是适合MBR-MBfR双膜耦合系统的最佳碳氮比。用于处理实际废水经过20 d的运行,结果表明,COD、NO3--N、NH4+-N、TN去除率分别达到75.88%、80.02%、76.42%和80.92%。达到较好的双膜耦合效果,为反应器高效脱氮以及去除含有有机碳的低C/N废水提供参考和技术支持。高通量测序结果表明:1)作为氨氧化菌(AOB)的亚硝基...  相似文献   

6.
厌氧氨氧化技术利用NO2--N氧化NH4+-N来实现污水中氮素的高效去除,其中NO2-N的产生是实现厌氧氨氧化应用的难点,而短程硝化是获取NO2-N的重要途径之一。针对目前在实际工程中通过短程硝化难以实现长期稳定的亚硝酸盐累积的问题,介绍了厌氧氨氧化、短程反硝化工艺影响因素及工程应用的研究进展;分析了短程反硝化工艺累积NO2-N的过程,从而去除污水中的氮素污染物。对短程反硝化与厌氧氨氧化工艺耦合方式在处理实际废水时的可行性与应用前景进行展望。  相似文献   

7.
为了解决低C/N比污水的脱氮问题,本研究将NOx--N引入到初沉污泥厌氧发酵系统,利用初沉污泥厌氧发酵过程释放的有机碳源完成反硝化,以达到利用初沉污泥作为碳源强化污水脱氮的目的。通过对系统中VFAs积累、NOx--N去除及VSS变化情况的考察,对比研究了4种不同电子受体类型初沉污泥厌氧系统发酵性能、反硝化能力。得出:在34 d的发酵期里,NO3--N型系统以及NO2--N、NO3--N混合型系统中没有出现明显VFAs积累,而在NO2--N型系统和纯厌氧系统中出现了不同程度的VFAs积累,说明在试验条件下,NO3--N型和混合型系统发酵过程所释放的碳源能得到较好的利用;各系统中NOx--N还原总量分别为1692 mg·L-1(NO3--N型)、1330 mg·L-1(混合型)、1223 mg·L-1(NO2--N型),表明NO3--N型系统反硝化能力最强;此外,虽然各NOx--N系统中的VSS减量程度相对于厌氧系统稍有降低,但各系统均达到了60%以上的高VSS减量水平,其中NO3--N型系统VSS减量67.9%,在各NOx--N系统中最高。综上,NO3--N型初沉污泥厌氧发酵系统能同时取得相对最好的反硝化脱氮及污泥减量性能。  相似文献   

8.
采用两级A/O-海绵填料工艺处理DMF废水,探究一级A/O缺氧池(A1)和二级A/O缺氧池(A2)分段进水比(8∶2、7∶3、6∶4、5∶5)对系统脱氮除碳效能影响。结果表明,两级A/O-海绵填料工艺在不同分段进水比条件下均能实现对COD的高效去除,COD平均去除率均达到95%以上,而系统对TN、NO;-N和NH;-N的去除受分段进水比影响较大。在较高(8∶2和7∶3)分段进水比条件下,系统TN去除率为81.39%~89.03%,此时TN主要以NH4+-N和NO3--N形式存在;当分段进水比减小为6∶4时,系统TN去除率达到最优值91.33%,出水NH4+-N和NO3--N均明显低于其余进水比工况,分别降至8.04 mg/L和7.06 mg/L。因此通过优化两级A/O-海绵填料工艺分段进水比,可提升高浓度有机氮废水中难降解碳源的利用率与控制氨化反应进程,实现DMF废水有机氮的高效去除。  相似文献   

9.
探讨了新型生物电化学-颗粒污泥反应器在不同进水氮浓度下的脱氮效能与产电性能,并从颗粒污泥的关键酶活性、胞外聚合物组分以及微生物群落分布等角度系统研究了其影响机制。结果表明,COD、NO3--N、NO2--N和溶解性甲烷在第Ⅰ、Ⅱ、Ⅲ、Ⅳ阶段(进水NO3--N和NO2--N浓度分别为60 mg·L-1和20 mg·L-1、100mg·L-1和40 mg·L-1、140 mg·L-1和60 mg·L-1、180 mg·L-1和80 mg·L-1)均得以有效去除,其中COD去除率在第Ⅳ阶段效果最佳,去除率达96%以上,NO3--N出水浓度在第Ⅱ阶段更为稳定,其去除率达99%以上,NO2  相似文献   

10.
为考察厌氧氨氧化反应器快速启动效果和脱氮性能,按照3∶1的体积比接种厌氧池厌氧污泥和氧化沟好氧污泥,运行77 d成功启动厌氧氨氧化反应。启动过程中反应器内污泥由黑色变为棕黄色最终变为红棕色,并逐渐颗粒化。采用高通量测序技术对启动成功后的厌氧氨氧化颗粒污泥进行微生物群落结构分析,发现主要菌门为:浮霉菌门(Planctomycetes)、变形菌门(Proteobacteria)、绿弯菌门(Chloroflexi)、拟杆菌门(Bacteroidetes)和酸杆菌门(Acidobacteria),其中浮霉菌门(Planctomycetes)相对丰度最大,占比41.98%。厌氧氨氧化菌(AnAOB)的优势菌属为Candidatus_Brocadia属,占比为38.78%。反应器稳定运行阶段NH4+-N和NO2--N平均去除率分别达到97.00%和98.58%,TN平均去除率及TN平均去除负荷分别达到81.57%和0.14 g/(L·d),化学计量比Δn(NH4+-N...  相似文献   

11.
生活污水对成熟厌氧氨氧化颗粒污泥的影响   总被引:1,自引:0,他引:1  
部分短程硝化和厌氧氨氧化技术的研究主要集中在高氨氮废水方面,对低氨氮浓度生活污水的研究相对较少。使经过除碳和部分短程硝化后的实际生活污水进入厌氧氨氧化UASB反应器,探究生活污水对成熟厌氧氨氧化颗粒污泥的影响。结果表明,当厌氧氨氧化UASB反应器的进水由配水变为生活污水后,反应器出水中氨氮浓度可降到5 mg·L-1以下,亚硝态氮浓度可降到1 mg·L-1以下,但是硝态氮的生成量高于理论值,可能是溶解氧被带入UASB反应器使硝化作用增强。UASB反应器内厌氧氨氧化污泥颜色由红色变为红黑色,T-EPS含量减少,PN/PS由1.13增大到3.66,沉降性变好,反应器内污泥中厌氧氨氧化菌Candidatus Brocadia所占比例由17.7%减少为14.4%,系统内AOB和NOB菌的含量增加,如果能够降低进入UASB反应器的溶解氧,有可能会减少出水硝氮,达到较好总氮去除效果。  相似文献   

12.
在好氧条件下,构建了蜂窝填料三相流化床,研究了三相流化床去除城市污水中总氮的效果以及氨态氮、亚硝酸盐和硝态氮转化规律.结果表明,当HRT为3h时,三相流化床对总氮去除率为52.61%.氨氮去除率为45.71%,进、出水中的亚硝酸盐和硝酸盐氮质量浓度均较低(进水低于1.12 mg/L,出水低于4.52 mg/L).对剥落...  相似文献   

13.
The performance of nitrogen removal and electricity generation of a novel bio-electrochemical-granular sludge reactor at different influent nitrogen concentration was investigated. The impact mechanism of granular sludge, key enzyme activity, extracellular polymer composition and microbial community distribution were systematically studied. The results showed that COD, NO3--N, NO2--N and dissolved methane were efficiently removed in stages Ⅰ, Ⅱ, Ⅲ and Ⅳ (Influent NO3--N and NO2--N concentrations were 60 and 20 mg·L-1, 100 and 40 mg·L-1, 140 and 60 mg·L-1, 180 and 80 mg·L-1, respectively). The removal efficiency of COD was the highest in stage Ⅳ, and it was above 96%. The effluent concentration of NO3--N was the most stable at stage Ⅱ, and the removal efficiency was over 99%. The NO2--N removal efficiency was above 99% in each stage. In stage Ⅳ, the maximum power density and output voltage was 471.2 mV·m-3 and 608.1 mV at the fourth compartment, respectively. The polysaccharide and protein content of LB-EPS was the highest in stage Ⅱ of the fifth compartment, 13.7 mg·g-1 and 14.7 mg·g-1, respectively. Coenzyme F420 activity was the lowest in the first compartment. The protease activity of the sludge was increased due to the increase of influent nitrogen concentration. From stage Ⅰ to stage Ⅳ, the relative abundance of Protebaoteria was decreased, while the relative abundance of Chloroflexi, Firmicutes and Planctomycetes were increased. Although Thauera with denitrification effect was decreased by 8.64% in the first compartment, the nitrogen removal was still well in the reactor. The relative abundance of Methanothrix was increased to 12.3% in the fourth compartment, indicating that Methanothrix could co-exist with other bacteria in the reactor.  相似文献   

14.
CANON工艺处理实际晚期垃圾渗滤液的启动实验   总被引:1,自引:0,他引:1       下载免费PDF全文
针对晚期垃圾渗滤液NH4--N浓度高、C/N低、深度脱氮困难的问题,采用CANON工艺在曝气/缺氧搅拌循环交替的运行方式下,处理晚期垃圾渗滤液实现了深度脱氮。系统经过130 d的驯化培养后成功启动,长期试验研究结果表明,在进水COD、NH4--N、TN浓度(mg·L-1)分别为2050±250、1625±75和2005±352情况下,出水COD、NH4--N、TN浓度(mg·L-1)能达到407±14、8±4和19±4,总氮去除率达到了98.76%。在未投加外碳源的情况下,CANON工艺在曝气/缺氧搅拌的运行方式下实现了对晚期垃圾渗滤液的深度脱氮。此外,经荧光原位杂交(FISH)检测表明,在该运行方式下能够成功富集氨氧化菌和厌氧氨氧化菌,各占总菌数的19.5%±1.3%和42.7%±5.02%,为CANON工艺用于处理晚期垃圾渗滤液的工程应用提供参考。  相似文献   

15.
Mixed strains Delftia sp.YH01 and Acidovorax sp.YH02, with capability of heterotrophic nitrification-aerobic denitrification, were introduced into a two-stage aerobic sequencing batch reactor to enhance NO3--N removal. With optimal C/N of 8, efficient NO3--N removal was achieved at initial NO3--N concentration of 2000 mg·L-1. Meanwhile, the massive accumulation of NO2--N was avoided during the long operation. Compared to the one-stage aerobic sequencing batch reactor, the removal efficiency of NO3--N and TN in the two-stage aerobic sequencing batch reactor was increased by 36.5% and 42.7%, which respectively was 93.8% and 88.4%. Microbial community study showed that the mixed strains have the stronger viability and can synergistically denitrify with the indigenous microorganisms in system, such as Azoarcus, Uncultured Saprospiraceae, Thauera, Paracocccus, which could be major contributors for aerobic denitrification. The proposed technology was shown to achieve high-efficiency treatment of high NO3--N wastewater through aerobic denitrification.  相似文献   

16.
采用某污水处理厂A2/O工艺中的活性污泥为种泥,以模拟生活污水为对象,考察了交替式厌/缺氧-好氧双膜反硝化除磷工艺的启动与运行特性,并采用高通量测试技术分析系统除磷污泥的菌群结构。通过60天的启动试验,系统内反硝化聚磷菌占聚磷菌总数的比例由21.3%提高到94.4%,出水磷在0.6mg/L左右。通过逐步增加进水氨氮的方法运行2个月,系统的脱氮除磷效果稳定。在进水P浓度为6.4mg/L,保持进水N/P比为8.8,交替厌/缺氧-好氧双膜反硝化除磷工艺效能最优,可达0.12kgN/(m3?d)和0.018kgP/(m3?d),出水总磷(TP)0.8mg/L,总氮(TN)12mg/L,出水COD、NH3-N和TN达到国家综合排放标准GB18918-2002一级A排放标准。周期试验中,pH值、氧化还原电位(oxidation-reduction potential,ORP值)均可作为厌氧释磷的控制参数,ORP也可指示缺氧吸磷的终点。典型周期内硝酸盐、亚硝酸盐的消耗量与磷的吸收量基本呈线性关系。系统内污泥多样性约为种泥的0.5倍,在“门”、“属”分类级别上分别以ProteobacteriaXanthomonadales-nobank为主。  相似文献   

17.
傅金祥  罗迪  柳溪若  钱杰  由昆  张黎 《水处理技术》2021,47(3):110-113,118
通过批次实验和UASB反应的连续实验考察了在不同缺乏外源磷的程度时,厌氧氨氧化颗粒污泥对基质氮的去除情况以及出水磷含量的变化.结果表明,批次实验中,PO43--P的质量浓度在2.3?0mg/L对厌氧氨氧化顆粒污泥的脱氮效能没有明显的消极影响,而当P043--P的质量浓度为1.0mg/L时基质去除率93.160%比进水P...  相似文献   

18.
刘灵婕  季民  王芬  孙未  翟思媛  王阳 《化工进展》2018,37(12):4917-4923
采用石英砂、活性炭双层滤料反硝化深床滤柱处理城镇污水处理厂二沉池出水中硝酸盐氮(NO3--N),研究了深床滤柱反硝化脱氮性能以及主要反硝化功能基因对进水碳氮比(化学需氧量/总氮,即COD/TN,简称C/N)的响应。结果表明,NO3--N平均转化率随着C/N升高,由46.5%升高至90.0%,化学需氧量(COD)平均去除率由97.2%降至76.5%。低碳氮比(C/N<6)条件下,出水亚硝酸盐氮(NO2--N)出现明显的积累,在C/N=4.2时,积累率达41.5%,在高碳氮比(C/N ≥ 6)条件下,NO2--N积累量逐渐减少,直至出水无NO2--N。研究表明,反硝化深床滤柱对污染物的转化主要发生在前35cm滤料深度,COD去除率和NO3--N转化率分别为94.0%、81.2%。采用荧光实时定量PCR技术在C/N分别为4.2、6和7条件下,对深床滤柱中反硝化功能基因napAnarGnirKnirSnosZ数量进行分析,结果表明,随着C/N升高,各反硝化功能基因拷贝数也随之升高,说明增加碳源投加量可以为反硝化细菌提供更好的生长环境,有利于其生长繁殖,促进反硝化过程的进行;当narG基因拷贝数大于(nirS+nirK)基因拷贝数时,NO2--N会产生积累。  相似文献   

19.
长泥龄改良A2/O工艺的短程硝化反硝化除磷   总被引:1,自引:0,他引:1       下载免费PDF全文
罗亚红  李冬  鲍林林  许达  蔡言安  张杰 《化工学报》2014,65(12):4985-4996
为解决传统A2/O工艺硝化与除磷泥龄(SRT)之间的矛盾,进一步提高低C/N(P)比生活污水同步脱氮除磷效率,采用一种改良A2/O工艺在长SRT条件下处理生活污水.试验结果表明,该工艺可有效筛选和强化反应器内活性污泥,并大量富集长SRT的反硝化除磷菌(DPAO).通过亚硝酸盐氧化菌(NOB)淘洗阶段后,反应器在SRT=19.6d、A2O段污泥浓度(MLSS)=5.5 g·L-1、水力停留时间(HRT)=8.2 h、污泥回流比(R)=90%、硝化液回流比(r)=250%、溶解氧(DO)=1.5~0.3 mg·L-1,间歇曝气段HRT=4 h、曝气周期1 h曝气1 min(DO=0.3~0.5 mg·L-1)、沉淀59 min条件下长期运行,COD、NH4+-N、TP和TN的平均去除率分别为88.71%、99.2%、93.77%和89.52%,出水亚硝化率(NO2--N/NOx--N)可达97.2%,DPAO占聚磷菌(PAO)比为95.5%.污水中约72.96%的COD被DPAO合成PHA除磷,15.75%的COD由异养反硝化消耗,约41.96%和31.31%的N分别通过反硝化除磷和异养反硝化去除.剩余污泥主要由DPAO和反硝化菌增殖产生,分别占82.74%和17.24%,较传统脱氮除磷途径减少了58.76%的碳源消耗和44.6%的污泥排放.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号