Electrochemical hydrogen compression (EHC) is a promising alternative to conventional compressors for hydrogen storage at high pressure, because it has a simple structure, low cost of hydrogen delivery, and high efficiency. In this study, the performance of an EHC is evaluated using a three-dimensional numerical model and finite volume method. The results of numerical analysis for a single cell of EHC are extended to a full stack of EHC. In addition, exergy and exergoeconomic analyses are carried out based on the numerical data. The effects of operating temperature, pressure, and gas diffusion layer (GDL) thickness on the energy and exergy efficiencies and the exergy cost of hydrogen are examined. The motivation of this study is to examine the performance of the EHC at different working conditions and also to determine the exergy cost of hydrogen. The results reveal that the energy and exergy efficiency of EHC stack improve by almost 3.1% when operating temperature increases from 363 K to 393 K and the exergy cost of hydrogen decreases by 0.5% at current density of 5000 A m−2. It is concluded that energy and exergy efficiency of EHC stack decrease by 25% and 5.4% when the cathode pressure increases from 1 bar to 30 bar, respectively. Moreover, it is realized that the GDL thickness has a considerable effect on the EHC performance. The exergy cost of hydrogen decreases by 53% when the GDL thickness decreases from 0.5 mm to 0.2 mm at current density of 5000 A m−2.  相似文献   

2.
Energy and exergy analyses are reported of hydrogen production via an ocean thermal energy conversion (OTEC) system coupled with a solar-enhanced proton exchange membrane (PEM) electrolyzer. This system is composed of a turbine, an evaporator, a condenser, a pump, a solar collector and a PEM electrolyzer. Electricity is generated in the turbine, which is used by the PEM electrolyzer to produce hydrogen. A simulation program using Matlab software is developed to model the PEM electrolyzer and OTEC system. The simulation model for the PEM electrolyzer used in this study is validated with experimental data from the literature. The amount of hydrogen produced, the exergy destruction of each component and the overall system, and the exergy efficiency of the system are calculated. To better understand the effect of various parameters on system performance, a parametric analysis is carried out. The energy and exergy efficiencies of the integrated OTEC system are 3.6% and 22.7% respectively, and the exergy efficiency of the PEM electrolyzer is about 56.5% while the amount of hydrogen produced by it is 1.2 kg/h.  相似文献   

3.
A novel solar based combined system is proposed to produce hydrogen and cooling. The presented cogeneration system is analyzed in detail from the viewpoints of exergy and exergoeconomic (exergy based economic analysis). The proposed system includes a concentrated PVT (CPVT), a single effect LiBr-H2O absorption chiller and proton exchange membrane electrolyzer (PEM). Produced electrical power is consumed in the PEM electrolyzer to split water into oxygen and pure hydrogen while heat removal from the CPVT is done by the absorption chiller to guarantee its better performance. Second law analysis showed that, among the three different parts of the system, the most part of exergy destruction refers to the CPVT followed by absorption chiller unit and PEM electrolyzer. Also, it is observed that, among the absorption units' components, the highest percent of exergy destruction belongs to the generator which absorbs the heat from the CPVT. Moreover, exergoeconomic analysis revealed that the most important unit from the viewpoint of economic is the CPVT with the capital investment cost of 0.08946 $/h and an exergoeconomic factor of 28.82%.  相似文献   

4.
In this paper, a salinity gradient solar pond (SGSP) is used to harness the solar energy for hydrogen production through two cycles. The first cycle includes an absorption power cycle (APC), a proton exchange membrane (PEM) electrolyzer, and a thermoelectric generator (TEG) unit; in the second one, an organic Rankine cycle (ORC) with the zeotropic mixture is used instead of APC. The cycles are analyzed through the thermoeconomic vantage point to discover the effect of key decision variables on the cycles’ performance. Finally, NSGA-II is used to optimize both cycles. The results indicate that employing ORC with zeotropic mixture leads to a better performance in comparison to utilizing APC. For the base mode, unit cost product (UCP), exergy, and energy efficiency when APC is employed are 59.9 $/GJ, 23.73%, and 3.84%, respectively. These amounts are 47.27 $/GJ, 29.48%, and 5.86% if ORC with the zeotropic mixture is utilized. The APC and ORC generators have the highest exergy destruction rate which is equal to 6.18 and 10.91 kW. In both cycles, the highest investment cost is related to the turbine and is 0.8275 $/h and 0.976 $/h for the first and second cycles, respectively. In the optimum state the energy efficiency, exergy efficiency, UCP, and H2 production rate of the system enhances 42.44%, 27.54%,15.95%, and 38.24% when ORC with the zeotropic mixture is used. The maximum H2 production is 0.47 kg/h, and is obtained when the mass fraction of R142b, LCZ temperature, pumps pressure ratio, generator bubble point temperature are 0.603, 364.35 K, 2.12, 337.67 K, respectively.  相似文献   

5.
In this research paper, a newly energy system consisting of parabolic trough solar collectors (PTSC) field, a thermoelectric generator (TEG), a Rankine cycle and a proton exchange membrane (PEM) is proposed. The integration is performed by establishing a TEG instead of the condenser as power generation and cooling unit thereafter surplus power output of the TEG is transferred to the PEM electrolyzer for hydrogen production. The integrated renewable energy system is comprehensively modeled and influence of the effective parameters is investigated on exergy and economic indicators through the parametric study to better understand the system performance. Engineering equation solver (EES) as a potential engineering tool is used to simulate the system and obtain the desired results. In order to optimize the system, a developed multi-objective genetic algorithm MATLAB code is applied to determine the optimum operating conditions of the system. Obtained results demonstrate that at optimum working condition from exergy viewpoint, exergy efficiency and total cost are 12.76% and 61.69 $/GJ, respectively. Multi-objective optimization results further show that the final optimal point which is well-balanced between exergy efficiency and total cost, has the maximum exergy efficiency of 13.29% and total cost of 63.96 $/GJ, respectively. The corresponding values for exergy efficiency and total cost are 10.01% and 60.21 $/GJ for optimum working condition from economic standpoint. Furthermore, hydrogen production at well-balanced operating condition would be 2.28 kg/h. Eventually, the results indicate that establishing the TEG unit instead of the condenser is a promising method to optimize the performance of the system and reduce total cost.  相似文献   

6.
This paper deals with energy, exergy, economic, and environmental (4E) analysis of two new combined systems for simultaneous power and hydrogen production. The combined systems are integrated from a city gate station (CGS) system, a Rankine cycle (RC), an absorption power cycle (APC), and a proton exchange membrane (PEM) electrolyzer. Since the pressure of natural gas (NG) in transmission pipeline is high, this pressure is reduced at CGS to a lower pressure. However, this NG has also ample potential to be recovered for multiple productions, too. In the proposed systems, the outlet energy of NG is used for power and hydrogen production by employing RC/APC and PEM electrolyzer. The power sub-cycles are driven by waste heat of CGS, while PEM electrolyzer is driven by this waste heat along with a portion of CGS-Turbine output power. A comprehensive thermodynamic modeling and parametric study of the proposed combined systems are conducted from the 4E analysis viewpoint. The results of two proposed systems are compared with each other, considering a fixed value of 1 MW for RC- and APC-Turbines power. Under the same external conditions and using steam as working fluid of RC, the thermal efficiency of the combined CGS/PEM-RC and -APC systems are obtained 32.9% and 33.6%, respectively. The overall exergy efficiency of the combined CGS/PEM-RC and -APC systems are also calculated by 47.9% and 48.9%, respectively. Moreover, the total sum unit cost of product (SUCP) and CO2 emission penalty cost rate are obtained 36.9 $/GJ and 0.033 $/yr for the combined CGS/PEM-RC and 36 $/GJ and 0.211 $/yr for the combined CGS/PEM-APC systems, respectively. The results of exergy analysis also revealed that the vapor generator (in both systems) has the main contribution in the overall exergy destruction.  相似文献   

7.
This paper investigates the performance of a high temperature Polymer Electrolyte Membrane (PEM) electrolyzer integrated with concentrating solar power (CSP) plant and thermal energy storage (TES) to produce hydrogen and electricity, concurrently. A finite-time-thermodynamic analysis is conducted to evaluate the performance of a PEM system integrated with a Rankine cycle based on the concept of exergy. The effects of solar intensity, electrolyzer current density and working temperature on the performance of the overall system are identified. A TES subsystem is utilized to facilitate continuous generation of hydrogen and electricity. The hydrogen and electricity generation efficiency and the exergy efficiency of the integrated system are 20.1% and 41.25%, respectively. When TES system supplies the required energy, the overall energy and exergy efficiencies decrease to 23.1% and 45%, respectively. The integration of PEM electrolyzer enhances the exergy efficiency of the Rankine cycle, considerably. However, it causes almost 5% exergy destruction in the integrated system due to conversion of electrical energy to hydrogen energy. Also, it is concluded that increase of working pressure and membrane thickness leads to higher cell voltage and lower electrolyzer efficiency. The results indicate that the integrated system is a promising technology to enhance the performance of concentrating solar power plants.  相似文献   

8.
The present study aimed to investigate a multi-generation energy system for the production of hydrogen, freshwater, electricity, cooling, heating, and hot water. Steam Rankine cycle (SRC), organic Rankine cycle (ORC), absorption chiller, Parabolic trough collectors (PTCs), geothermal well, proton exchange membrane (PEM) electrolyzer, and reverse osmosis (RO) desalination are the main subsystems of the cycle. The amount of exergy destruction is calculated for each component after modeling and thermodynamic analysis. The PTCs, absorption chiller, and PEM electrolyzer had the highest exergy destruction, respectively. According to meteorological data, the system was annually and hourly tested for Dezful City. For instance, it had a production capacity of 13.25 kg/day of hydrogen and 147.42 m3/day of freshwater on 17th September. Five design parameters are considered for multi-objective optimization after investigating objective functions, including cost rate and exergy efficiency. Using a Group method of data handling (GMDH), a mathematical relation is obtained between the input and output of the system. Next, a multi-objective optimization algorithm, a non-dominated sorting genetic algorithm (NSGA-II), was used to optimize the relations. A Pareto frontier with a set of optimal points is obtained after the optimization. In the Pareto frontier, the best point is selected by the decision criterion of TOPSIS. At the TOPSIS point, the exergy efficiency is 31.66%, and the total unit cost rate is 21.9 $/GJ.  相似文献   

9.
In this study, a comprehensive performance analysis of a transportation system powered by a PEM fuel cell engine system is conducted thermodynamically both through energy and exergy approaches. This system includes system components such as a compressor, humidifiers, pressure regulator, cooling system and the fuel cell stack. The polarization curves are studied in the modeling and compared with the actual data taken from the literature works before proceeding to the performance modeling. The system performance is investigated through parametric studies on energy, exergy and work output values by changing operating temperature, operating pressure, membrane thickness, anode stoichiometry, cathode stoichiometry, humidity, reference temperature and reference pressure. The results show that the exergy efficiency increases with increase of temperature from 323 to 353 K by about 8%, pressure from 2.5 to 4 atm by about 5%, humidity from 97% to 80% by about 10%, and reference state temperature from 253 to 323 K by about 3%, respectively. In addition, the exergy efficiency increases with decrease of membrane thickness from 0.02 to 0.005 mm by about 9%, anode stoichiometry from 3 to 1.1 by about 1%, and cathode stoichiometry from 3 to 1.1 by about 35% respectively.  相似文献   

10.
In this paper, a mathematical model is developed to study the performance of a polymer membrane electrolyser (PEM) and the effect of different parameters including operating temperature, cathode pressure, membrane thickness, the width and height of channel and current density on the performance and energy and exergy efficiency of PEM electrolyser are investigated. In addition to the resistance overvoltage of components, the concentration overvoltage is modeled using an accurate equation. The model is validated against experimental data. The results indicate that by increasing current density, the voltage of the electrolyser increases, and energy and exergy efficiencies reduce. Increase of temperature from 313 K to 353 K, and decrease of cathode pressure from 40 bar to 1 bar lead to decrease of voltage of the PEM electrolyser by 8.3% and 4.8%, respectively. Moreover, energy and exergy efficiencies increase between 2% and 6% in the range of working temperature and pressure. It is concluded that decrease of membrane thickness, height and width of channel, and increase of exchange current density of the anode and cathode electrodes lead to decrease of voltage of the electrolyser and increase of energy and exergy efficiencies. However, the effect of temperature and cathode pressure and the exchange current densities is greater than the effect of geometric parameters.  相似文献   

11.
In this paper, a conceptual hybrid biomass gasification system is developed to produce hydrogen and is exergoeconomically analyzed. The system is based on steam biomass gasification with the lumped solid oxide fuel cell (SOFC) and solid oxide electrolyser cell (SOEC) subsystem as the core components. The gasifier gasifies sawdust in a steam medium and operates at a temperature range of 1023-1423 K and near atmospheric pressure. The analysis is conducted for a specific steam biomass ratio of 0.8 kmol-steam/kmol-biomass. The gasification process is assumed to be self-thermally standing. The pressurized SOFC and SOEC are of planar types and operate at 1000 K and 1.2 bar. The system can produce multi-outputs, such as hydrogen (with a production capacity range of 21.8-25.2 kgh−1), power and heat. The internal hydrogen consumption in the lumped SOFC-SOEC subsystem increases from 8.1 to 8.6 kg/h. The SOFC performs an efficiency of 50.3% and utilizes the hydrogen produced from the steam that decomposes in the SOEC. The exergoeconomic analysis is performed to investigate and describe the exergetic and economic interactions between the system components through calculations of the unit exergy cost of the process streams. It obtains a set of cost balance equations belonging to an exergy flow with material streams to and from the components which constitute the system. Solving the developed cost balance equations provides the cost values of the exergy streams. For the gasification temperature range and the electricity cost of 0.1046 $/kWh considered, the unit exergy cost of hydrogen ranges from 0.258 to 0.211 $/kWh.  相似文献   

12.
This study presents an analysis and assessment study of an integrated system which consists of cryogenic air separation unit, polymer electrolyte membrane electrolyzer and reactor to produce ammonia for a selected case study application in Istanbul, Turkey. A thermodynamic analysis of the proposed system illustrates that electricity consumption of PEM electrolyzer is 3410 kW while 585.4 kW heat is released from ammonia reactor. The maximum energy and exergy efficiencies of the ammonia production system which are observed at daily average irradiance of 200 W/m2 are found as 26.08% and 30.17%, respectively. The parametric works are utilized to find out the impacts of inlet air conditions and solar radiation intensity on system performance. An increase in the solar radiation intensity results in a decrease of the efficiencies due to higher potential of solar influx. Moreover, the mass flow rate of inlet air has a substantial effect on ammonia production concerning the variation of generated nitrogen. The system has a capacity of 0.22 kg/s ammonia production which is synthesized by 0.04 kg/s H2 from PEM electrolyzer and 0.18 kg/s N2 from a cryogenic air separation unit. The highest exergy destruction rate belongs to PEM electrolyzer as 736.2 kW while the lowest destruction rate is calculated as 3.4 kW for the separation column.  相似文献   

13.
Based on a high temperature proton exchange membrane fuel cell (HT-PEMFC), a cogeneration system is proposed to produce heat and power. The system includes a coke oven gas steam reformer, a water gas shift reactor, and an afterburner. The system is analyzed in detail considering the energy, exergy and economic viewpoints. The analyses reveal the importance of HT-PEMFC in the system and according to the results, 9.03 kW power is generated with energy and exergy efficiencies of 88.2% and 26.2%, respectively and the total product unit cost is calculated as 91.8 $/GJ. Through a parametric study the effects on system performance are studied of such variables as the current density, fuel cell and reformer operating temperatures, and cathode stoichiometric ratio. It is found that an increase in the fuel cell temperature and/or a decrease in the reformer temperature enhance the exergy efficiency. The exergy efficiency is also maximized at the cathode stoichiometric ratio of 2.4. By performing a two-objective optimization using genetic algorithm, the best operating point is determined at which the exergy efficiency is (32.86%) and the total product unit cost is (78.68 $/GJ).  相似文献   

14.
A transient thermodynamic analysis is reported of a novel chemical hydrogen storage system using energy and exergy approaches. The hydrogen is stored chemically in ammonia using the proposed hydrogen storage system and recovered via the electrochemical decomposition of ammonia through an ammonia electrolyzer. The proposed hydrogen storage system is based on a novel subzero ammonia production reactor. A single stage refrigeration system maintains the ammonia production reactor at a temperature of −10 °C. The energy and exergy efficiencies of the proposed system are 85.6% and 85.3% respectively. The proposed system consumes 34.0 kJ of work through the process of storing 1 mol of hydrogen and recovering it using the ammonia electrolyzer. The system is simulated for filling 30,000 L of ammonia at a pressure of 5 bar, and the system was able to store 7500 kg of ammonia in a liquid state (1% vapor) in 1500 s. The system consumes nearly 45.3 GJ of energy to store the 7500 kg of ammonia and to decompose it to reproduce the stored hydrogen during the discharge phase.  相似文献   

15.
In this paper, the thermodynamic study of a combined geothermal power-based hydrogen generation and liquefaction system is investigated for performance assessment. Because hydrogen is the energy of future, the purpose of this study is to produce hydrogen in a clear way. The results of study can be helpful for decision makers in terms of the integrated system efficiency. The presented integrated hydrogen production and liquefaction system consists of a combined geothermal power system, a PEM electrolyzer, and a hydrogen liquefaction and storage system. The exergy destruction rates, exergy destruction ratios and exergetic performance values of presented integrated system and its subsystems are determined by using the balance equations for mass, energy, entropy, energy and exergy and evaluated their performances by means of energetic and exergetic efficiencies. In this regard, the impact of some design parameters and operating conditions on the hydrogen production and liquefaction and its exergy destruction rates and exergetic performances are investigated parametrically. According to these parametric analysis results, the most influential parameter affecting system exergy efficiency is found to be geothermal source temperature in such a way that as geothermal fluid temperature increases from 130 °C to 200 °C which results in an increase of exergy efficiency from 38% to 64%. Results also show that, PEM electrolyzer temperature is more effective than reference temperature. As PEM electrolyzer temperature increases from 60 °C to 85 °C, the hydrogen production efficiency increases from nearly 39% to 44%.  相似文献   

16.
In this study, a novel multi-generation system is proposed by integrating a solid oxide fuel cell (SOFC)-gas turbine (GT) with multi-effect desalination (MED), organic flash cycle (OFC) and polymer electrolyte membrane electrolyzer (PEME) for simultaneous production of electricity, fresh water and hydrogen. A comprehensive exergoeconomic analysis and optimization are conducted to find the best design parameters considering exergy efficiency and total unit cost of products as objective functions. The results show that the exergy efficiency and the total unit cost of products in the optimal condition are 59.4% and 23.6 $/GJ, respectively, which offers an increase of 2% compared to exergy efficiency of SOFC-GT system. Moreover, the system is capable of producing 2.5 MW of electricity by the SOFC-GT system, 5.6 m3/h of fresh water by MED unit, and 1.8 kg/h of hydrogen by the PEME. The associated cost for producing electricity, fresh water and hydrogen are 3.4 cent/kWh, 37.8 cent/m3, and 1.7 $/kg, respectively. A comparison between the results of the proposed system and those reported in other related papers are presented. The diagram of the exergy flow is also plotted for the exact determination of the exergy flow rate in each component, and also, location and value of exergy destruction. Finally, the capability of the proposed system for a case study of Iran is examined.  相似文献   

17.
A techno-economic assessment of hydrogen production from waste heat using a proton exchange membrane (PEM) electrolyzer and solid oxide electrolyzer cell (SOEC) integrated separately with the Rankine cycle via two different hybrid systems is investigated. The two systems run via three available cement waste heats of temperatures 360 °C, 432 °C, and 780 °C with the same energy input. The waste heat is used to run the Rankine cycle for the power production required for the PEM electrolyzer system, while in the case of SOEC, a portion of waste heat energy is used to supply the electrolyzer with the necessary steam. Firstly, the best parameters; Rankine working fluid for the two systems and inlet water flow rate and bleeding ratio for the SOEC system are selected. Then, the performance of the two systems (Rankine efficiency, total system efficiency, hydrogen production rate, and economic and CO2 reduction) is investigated and compared. The results reveal that the two systems' performance is higher in the case of steam Rankine than organic, while a bleeding ratio of 1% is the best condition for the SOEC system. Rankine output power, total system efficiency, and hydrogen production rate rose with increasing waste heat temperature having the same energy. SOEC system produces higher hydrogen production and efficiency than the PEM system for all input waste heat conditions. SOEC can produce 36.9 kg/h of hydrogen with a total system efficiency of 23.8% at 780 °C compared with 27.4 kg/h and 14.45%, respectively, for the PEM system. The minimum hydrogen production cost of SOEC and PEM systems is 0.88 $/kg and 1.55 $/kg, respectively. The introduced systems reduce CO2 emissions annually by about 3077 tons.  相似文献   

18.
Hybridized engines have become the focus of research nowadays in order to update the existing engines in different transportation sectors. This paper presents a hybridized aircraft engine consisting of a molten carbonate fuel cell system and a commercial turbofan system. The MCFC units are connected to a steam reforming and a water gas shift system. Also, five clean fuels are selected, such as dimethyl ether, hydrogen, ethanol, methane, and methanol, which are combined with different mass ratios to form five different fuel blends. The hybridized aircraft is investigated using three approaches: exergy analysis, exergoeconomic analysis, and exergoenvironmental analysis. It is found that the proposed engine has an average exergetic efficiency of 88% and an average exergy destruction ratio of 12%. The specific exergetic cost of electricity of the engine has an average value of 710 $/GJ for the high-pressure turbine and 230$/GJ for the intermediate and low-pressure turbines, as well as 50 $/GJ for the MCFC. The average specific exergoenvironmental impact of electricity is 14 mPt/MJ for turbines and 4 mPt/MJ for the MCFC. In addition, a blend of ethanol and hydrogen appears to be a viable option economically and environmentally.  相似文献   

19.
In today, the basic necessity for the economic and social development of countries is to have a cheap, reliable, sustainable, and environmentally friendly energy source. For this reason, renewable energy sources stand out as the most important key. Solar energy-based multi-energy generation systems are one of the most important options among the current scenarios to prevent global warming. In this presented study, electricity and hydrogen production from a solar collector with medium temperature density is investigated. In this system, 34 pipes evacuated tube solar collector (ETSC) is used for thermal energy generation, organic Rankine cycle (ORC) for electricity generation, and Proton exchanger membrane electrolyzer (PEMe) for hydrogen production. In addition, the energy and exergy efficiencies of the whole system calculated as 51.82% and 16.30%, respectively. Moreover, the amount of hydrogen obtained in PEM is measured as 0.00527 kg/s.  相似文献   

20.
Energy and exergy analyses of an integrated system based on anaerobic digestion (AD) of sewage sludge from wastewater treatment plant (WWTP) for multi-generation are investigated in this study. The multigeneration system is operated by the biogas produced from digestion process. The useful outputs of this system are power, freshwater, heat, and hydrogen while there are some heat recoveries within the system for improving efficiency. An open-air Brayton cycle, as well as organic Rankine cycle (ORC) with R-245fa as working fluid, are employed for power generation. Also, desalination is performed using the waste heat of power generation unit through a parallel/cross multi-effect desalination (MED) system for water purification. Moreover, a proton exchange membrane (PEM) electrolyzer is used for electrochemical hydrogen production option in the case of excess electricity generation. The heating process is performed via the rejected heat of the ORC's working fluid. The production rates for products including the power, freshwater, hydrogen, and hot water are obtained as 1102 kW, 0.94 kg/s, 0.347 kg/h, and 1.82 kg/s, respectively, in the base case conditions. Besides, the overall energy and exergy efficiencies of 63.6% and 40% are obtained for the developed system, respectively.  相似文献   