 共查询到20条相似文献,搜索用时 15 毫秒
1.
Due to the high cost of fossil fuels and the environmental problems caused by the extensive use of air-conditioning systems for both residential and industrial buildings, the use of solar energy to drive cooling cycles becomes attractive since the cooling load is roughly in phase with solar energy availability particularly in Tunisia. In this paper, we present a research project aiming at assessing the feasibility of solar-powered absorption cooling technology under Tunisian conditions. Simulations using the TRNSYS and EES programs with a meteorological year data file containing the weather parameters of Tunis, the capital of Tunisia, were carried out in order to select and size the different components of the solar system to be installed. The optimized system for a typical building of 150 m2 is composed of a water lithium bromide absorption chiller of a capacity of 11 kW, a 30 m2 flat plate solar collector area tilted 35° from the horizontal and a 0.8 m3 hot water storage tank.  相似文献   

2.
The impact from using cool roof coatings on the cooling and heating loads and the indoor thermal comfort conditions of residential buildings for various climatic conditions is estimated. The energy cooling loads and peak cooling demands are estimated for different values of roof solar reflectance and roof U-value. The results show that increasing the roof solar reflectance reduces cooling loads by 18–93% and peak cooling demand in air-conditioned buildings by 11–27%. The indoor thermal comfort conditions were improved by decreasing the hours of discomfort by 9–100% and the maximum temperatures in non air-conditioned residential buildings by 1.2–3.3 °C. These reductions were found to be more important for poorly or non-insulated buildings. For the locations studied, the heating penalty (0.2–17 kWh/m2 year) was less important than the cooling load reduction (9–48 kWh/m2 year). The application of cool roof coatings is an effective, minimal cost and easy to use technique that contributes to the energy efficiency and the thermal comfort of buildings.  相似文献   

3.
Shanghai is characteristic of subtropical monsoonal climate with the mean annual temperature of 17.6 °C, and receives annual total radiation above 4470 MJ/m2 with approximately 2000 h of sunshine. A solar energy system capable of heating, cooling, natural ventilation and hot water supply has been built in Shanghai Research Institute of Building Science. The system mainly contains 150 m2 solar collector arrays, two adsorption chillers, floor radiation heating pipes, finned tube heat exchangers and a hot water storage tank of 2.5 m3 in volume. It is used for heating in winter, cooling in summer, natural ventilation in spring and autumn, hot water supply in all the year for 460 m2 building area. The whole system is controlled by an industrial control computer and operates automatically. Under typical weather condition of Shanghai, it is found that the average heating capacity is up to 25.04 kW in winter, the average refrigerating output reaches 15.31 kW in summer and the solar-enhanced natural ventilation air flow rate doubles in transitional seasons. The experimental investigation validated the practical effective operation of the adsorption cooling-based air-conditioning system. After 1-year operation, it is confirmed that the solar system contributes 70% total energy of the involved space for the weather conditions of Shanghai.  相似文献   

4.
Cooling load calculation is the first step in designing the air-conditioning system of a building. The calculated cooling capacity with appropriate buffer is then used to select the number and size of chillers in the system. N + 1 is a common formula used by designers to size the chiller plants in Hong Kong buildings, where N is the actual number of chillers required and 1 is a redundant chiller provided to ensure reliability. This paper reviews the problem of excess capacity and discusses the risk exposure of chiller systems without redundant chillers. The cooling load profiles of the chiller plants of four medium-sized commercial buildings in Hong Kong are reviewed. The risk exposure of chiller systems without redundant chillers can be minimized by applying risk-based preventive maintenance. The just-in-demand design reduces capital cost of the building and frees up funds for continuous energy measurement and improving the energy efficiency of chiller plant systems. This paper presents a model for designing chiller plants that improves the energy efficiency of the plant in a cost effective and thoughtful manner. It is designed with consideration of the life cycle of the plant and real-time continuous commissioning, monitoring, measurement, comparison and execution for better energy management.  相似文献   

5.
The design of buildings to provide a suitable thermal environment is discussed and the reasons for artificial heating or cooling introduced. The problem of sizing a solar-powered cooling plant is investigated. An iterative method of estimating heat flow and resultant temperatures in buildings subject to fluctuating heat loads is described. A model is developed to allow investigation of the performance of a solar collector and thermal storage system and some of the basic relationships between performance and physical parameters are determined.

An iterative method of predicting the cooling output from a lithium bromide-water absorption refrigeration plant having variable heat input is described.

The design of a solar collector/thermal storage) absorption cooler system, its performance on a particular building and its fine tuning are examined.  相似文献   

6.
A group of buildings in the pharmaceutical industry located in Southern Germany is experiencing a trend of growing cooling loads to be met by the chilled water plant composed of 10 chillers of greatly varying cost effectiveness. With a capacity shortfall inevitable, the question arises whether to install an additional chiller or improve the utilization of the existing chillers, in particular those with low operating costs per unit cooling, through the addition of a chilled water thermal energy storage (TES) system. To provide decision support in this matter, an optimization environment was developed and validated that adopts mixed integer programming as the approach to optimizing the chiller dispatch for any load condition, while an overarching dynamic programming based optimization approach optimizes the charge/discharge strategy of the TES system. In this fashion, the chilled water plant optimization is decoupled but embedded in the TES control optimization. The approach was selected to allow for arbitrary constraints and optimization horizons, while ensuring a global optimum to the problem.  相似文献   

7.
This paper reviews 17 measures to reduce phosphorus leakage from Swedish agriculture to surface waters. Our aim is to evaluate the possible contribution from agriculture to achieve environmental goals including the Baltic Sea Action Plan. Using a regional approach integrating the variability in field specific characteristics, typical costs and national potential for the included measures may be estimated without identifying, e.g., suitable individual fields for implementation. The result may be helpful to select suitable measures but may also influence the design of environmental targets before they are determined.We find that the cheapest measures are reduced phosphorus content in animal food and fertilizer application supervision in pig farms, both measures with annual potentials of around 50 t each, and costs of €7 to €11 kg− 1 yr− 1. The total potential of the listed measures is an annual phosphorus reduction to surface waters of 242 t. If the most expensive measures are excluded (> €1000 kg− 1 yr− 1) and including retention in lakes the phosphorus transport to the sea could be reduced by 165 t yr− 1. This amount can be compared with the Swedish commitment in the Baltic Sea Action Plan (BSAP) to reduce input to the Baltic Proper by 290 t yr− 1.  相似文献   

8.
Micro gas turbines are considered to meet the electrical, domestic hot water, heating and cooling energy needs of a residential building located in Tehran, Ahvaz and Hamedan. The building is 10 stories high and has a total of 8000 m2 floor area with the peak demands of electricity of 32.96 kW, DHW of 0.926 kW, heating load of 1590 kW and the cooling load of 2028 kW, when the building is located in Tehran. With these demands, 30 micro turbines of 30 kW (nominal power) are needed to meet all the energy needs of the building. The excess electricity generated by the micro turbines is to be used in a heat pump, and the energy in the exhaust gases is to be used to meet other thermal energy needs of the building. With proper energy conservation measures and the use of ceiling fans in each room, the peak heating and cooling demands of the building were reduced to 225 kW and 760 kW, respectively. With these measures, two micro gas turbines of 30 kW nominal capacity, or one of 40 kW, could meet all the electrical, DHW, heating and a great portion of the cooling needs of the building. The remaining cooling needs of the building during the hot hours of summer could be met by an additional absorption refrigeration, utilizing natural gas as its energy source. It is recommended that with energy conservation measures, the heating and cooling loads of buildings be reduced as much as possible, and micro gas turbines be employed to meet the electrical demands and a portion of heating and cooling needs. The remaining thermal energy needs are to be met through the use of natural gas. Only with these measures, the on-site combined heat and power (OS-CHP) is a viable option for residential buildings in Iran.  相似文献   

9.
A double-skin system (double-glazed external wall) is an effective passive system that can be used to decrease solar heat gain into buildings. Detailed information on the thermal distribution of double-skin facades is necessary to design better systems that can provide thermal comfort and conserve energy. In this study, the three-dimensional thermal characteristics of double-skin facades that had the ventilation opening installed partially and were screened partially by the adjacent buildings were investigated by field measurements. To that end, field measurements were carried out on the double-skin exterior wall (9.4 m high and 27.0 m wide) installed in an atrium located in the west of an existing building during cooling period for typical summer conditions. Maximum air change rate of natural ventilation through the bottom opening up to the top opening is about 20–25 [1/h], the reduction ratio of total solar heat gain compared with those of non-natural ventilation is about 25%. The exhaust solar heat gain is about 100 W/m2 per inner glass surface area of the double-skin facades. Air temperature distribution of air space in the double skin was ranged from 30 °C to 44 °C, and heat gain difference ranged from 50 W/m2 to 130 W/m2. The influence of the ventilation openings and the shade conditions on temperature distribution of double skin is found to be significant and the double-skin system was verified to reduce the cooling loads effectively.  相似文献   

10.
It is possible to evaluate the energy demand as well as the parameters related to indoor thermal comfort through building energy simulation tools. Since energy demand for heating and cooling is directly affected by the required level of thermal comfort, the investigation of the mutual relationship between thermal comfort and energy demand (and therefore operating costs) is of the foremost importance both to define the benchmarks for energy service contracts and to calibrate the energy labelling according to European Directive 2002/92/CE. The connection between indoor thermal comfort conditions and energy demand for both heating and cooling has been analyzed in this work with reference to a set of validation tests (office buildings) derived from a European draft standard. Once a range of required acceptable indoor operative temperatures had been fixed in accordance with Fanger's theory (e.g. −0.5 < PMV < −0.5), the effective hourly comfort conditions and the energy consumptions were estimated through dynamic simulations. The same approach was then used to quantify the energy demand when the range of acceptable indoor operative temperatures was fixed in accordance with de Dear's adaptive comfort theory.  相似文献   

11.
Cooling load reduction by using thermal mass and night ventilation   总被引:1,自引:0,他引:1  
We provide a quantitative understanding of the relationship between thermal mass and cooling load, i.e. the effect of thermal mass on energy consumption of air-conditioning in office buildings. A simple office-building model with air-conditioning at daytime and free cooling at nighttime is analyzed in detail to quantify the hourly and overall variation of cooling load of air-conditioning. As an important parameter, an increase of time constant can effectively reduce the cooling load, by as much as more than 60% when the time constant is more than 400 h. However, when the time constant is larger than 1000 h, a further increase may slightly increase the cooling load, as a too large time constant may also postpone the heat release of thermal mass until the daytime. For the most effective reduction of cooling load, the interior and exterior convective heat transfer numbers need to be matched.  相似文献   

12.
《Energy and Buildings》2006,38(5):447-453
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m2 solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80 °C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by 73.8% at a 42% latent load. The optimal ratio of adsorption refrigerating power to total cooling load for this kind of hybrid systems is also studied in this paper.  相似文献   

13.
Thermal insulation is one of the most effective energy conservation measures for cooling and heating in buildings. Therefore, determining and selecting the optimum thickness of insulation is the main subject of many engineering investigations. In this study, the determination of optimum insulation thickness on external walls of buildings is comparatively analyzed based on annual heating and cooling loads. The transmission loads, calculated by using measured long-term meteorological data for selected cities, are fed into an economic model (P1P2 method) in order to determine the optimum insulation thickness. The degree-hours method that is the simplest and most intuitive way of estimating the annual energy consumption of a building is used in this study. The results show that the use of insulation in building walls with respect to cooling degree-hours is more significant for energy savings compared to heating degree-hours in Turkey's warmest zone. The optimum insulation thickness varies between 3.2 and 3.8 cm; the energy savings varies between 8.47 and 12.19 $/m2; and the payback period varies between 3.39 and 3.81 years depending on the cooling degree-hours. On the other hand, for heating load, insulation thickness varies between 1.6 and 2.7 cm, energy savings varies between 2.2 and 6.6 $/m2, and payback periods vary between 4.15 and 5.47 years.  相似文献   

14.
This paper proposed a new solar assisted air source heat pump system with flexible operational modes to improve the performance of the heating system. A mathematical model was established on the solar assisted air source heat pump system for building heating with a heating capacity of 10 kW, and an air source heat pump unit was developed to validate the model. The effect of the solar collector area on the performance of the system running in Nanjing was studied. The results showed that the COP of the heat pump unit was enhanced with the increase of the solar radiation density during the typical sunny day in the heating season. In addition, the COP also increased in proportion to the solar collector area. Compared with the case when the solar collector area was 0 m2, the COP increase of the heat pump and the energy-saving rate were 11.22% and 24% respectively when the solar collector area was 40 m2. Meanwhile, the solar equivalent generation power efficiency could reach 11.8%.  相似文献   

15.
Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model. The model was validated using a wide range of operating data from an existing chiller with specific settings of outdoor temperature and condensing pressure in controlling the condensing temperature. The validated model was developed specifically to ascertain the maximum coefficient of performance of chiller (COP) together with the strategy for optimizing the condensing temperature under various operating conditions. It is found that the highest COP occurs at a part load ratio (PLR) of 0.71–0.84, depending on the outdoor temperature and the control of condensing temperature, rather than at full load. Yet the chillers operating at such part load conditions will cause extra energy used for the early staging of chilled water pumps. To minimize the overall chiller plant energy consumption, it is still preferable to implement chiller sequencing based on the full load condition than on the aforementioned PLRs. The results of this paper present criteria for implementing low-energy strategies for operating air-cooled chillers satisfying a given building cooling load profile.  相似文献   

16.
随着建筑围护结构保温性能的逐步提高,以室内人员为代表的内部因素已成为影响建筑负荷的重要不确定性因素,内部负荷扰量(简称内扰)在空调负荷设计中的重要性需要被强调。通过对两栋办公建筑的实地测试发现,办公建筑中人员在室率普遍只有设计人数的40%~60%,设备的实际功率也远低于20 W/m~2的概算指标,过大的经验值是造成机组选型偏大的重要原因。重新思考标准中的人员密度系数和设备使用密度系数,以人为核心将建筑内扰负荷结合起来,提出"代表人"的内扰负荷计算方法,并对案例建筑的负荷设计进行修正。相比最大实测冷负荷,修正后的设计冷负荷富余率均在10%以内。  相似文献   

17.
This paper examines the thermal performance of a roof-integrated solar concrete collector for reducing heat gain to a house and providing domestic hot water. The solar concrete collector is made of PVC pipes embedded in deck slab or concrete roof. No glazing on the top of the solar concrete collector or insulation at the back has been used as in conventional solar water heaters. To compare the energy saving, two test rooms of 2.3 m width, 2.5 m length and 2.5 m height were built. In the first room, the reinforced cement concrete (R.C.C.) slab was used as deck slab whereas the second room was equipped with a cement concrete solar collector. The experimental results showed that the cement concrete solar collector is extremely interesting as it can produce up to 40 l of hot water per day at water temperatures ranging from 40 to 50 °C. A mathematical model based on the conservation equations of energy is developed to predict the performance of the cement concrete solar collector. There is reasonable agreement from the comparison between measured data and predicted results. The economic analysis indicates that the payback period is rather fast.  相似文献   

18.
Many central cooling systems in air-conditioned buildings have multiple chillers to meet various cooling load requirements. This paper further develops optimum load sharing strategies for the chillers in order to maximize their aggregate coefficient of performance (COP). Based on the part load performance curves of air-cooled screw chillers, it is ascertained that for two equally sized chillers operating, one should carry a full load and the other should be partially loaded to meet the system load. When two chillers of different sizes are running, the larger chiller should be fully loaded and the smaller chiller should operate at part load in order that their combined capacity satisfies the system load. Such an uneven load sharing strategy for achieving maximum COP is independent of ambient conditions and the control of condensing temperature. The variable primary flow of chilled water should be applied to chillers in order to implement the strategy. The results of this paper are useful in developing low-energy chiller plants.  相似文献   

19.
This work proposes an efficient combined treatment for the decontamination of a pesticide-containing wastewater resulting from phytopharmaceutical plastic containers washing, presenting a moderate organic load (COD = 1662-1960 mg O2 L−1; DOC = 513-696 mg C L−1), with a high biodegradable organic carbon fraction (81%; BOD5 = 1350-1600 mg O2 L−1) and a remaining recalcitrant organic carbon mainly due to pesticides. Nineteen pesticides were quantified by LC-MS/MS at concentrations between 0.02 and 45 mg L−1 (14-19% of DOC). The decontamination strategy involved a sequential three-step treatment: (a) biological oxidation process, leading to almost complete removal of the biodegradable organic carbon fraction; (b) solar photo-Fenton process using CPCs, enhancing the bio-treated wastewater biodegradability, mainly due to pesticides degradation into low-molecular-weight carboxylate anions; (c) and a final polishing step to remove the residual biodegradable organic carbon, using a biological oxidation process. Treatment performance was evaluated in terms of mineralization degree (DOC), pesticides content (LC-MS/MS), inorganic ions and low-molecular-weight carboxylate anions (IC) concentrations. The estimated phototreatment energy necessary to reach a biodegradable wastewater, considering pesticides and low-molecular-weight carboxylate anions concentrations, Zahn-Wellens test and BOD5/COD ratio, was only 2.3 kJUV L−1 (45 min of photo-Fenton at a constant solar UV power of 30 W m−2), consuming 16 mM of H2O2, which pointed to 52% mineralization and an abatement higher than 86% for 18 pesticides. The biological oxidation/solar photo-Fenton/biological oxidation treatment system achieved pesticide removals below the respective detection limits and 79% mineralization, leading to a COD value lower than 150 mg O2 L−1, which is in agreement with Portuguese discharge limits regarding water bodies.  相似文献   

20.
Estimates of daily electrical cooling load for a city of 800,000 are developed based on the relationship between weather variables and daily-average electricity consumption over 1 year. The relationship is found to be nearly linear above a threshold temperature. Temperature and humidity were found to be the largest, at 59%, and second largest, at 21%, contributors to electrical cooling load. Direct normal irradiation intercepted by a vertical cylinder, DNI sin θ, was found to be a useful explanatory variable when modeling aggregates of buildings without a known or dominant orientation. The best study case model used DNI sin θ and diffuse horizontal irradiation (DHI) as distinct explanatory variables with annual electrical cooling load contributions of 9% and 11% respectively. Although the seasonal variation in electrical cooling load is large - on peak summer days more than 1.5 times the winter base load - the combined direct and diffuse solar contribution is essentially flat through the year, a condition at odds with the common assumption that solar cooling always provides a good match between supply and demand. The final model gives an electrical cooling load estimate for Abu Dhabi Island that corresponds to 40% of the total annual electrical load and 61% on the peak day.  相似文献   