首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the posterior partially edentulous jaw, implants may be used to supplement existing natural dentition. Frequently, the maxillary sinuses and the mandibular nerve preclude the fabrication of freestanding implant-retained prostheses. However, if an implant and a natural abutment are combined, a fixed prosthesis can be fabricated, restoring the arch into the premolar area. The histories of three patients with attachments connecting implant-retained ceramotitanium crowns with crowns on natural abutments are described. A design for a rigid custom-made attachment for the Br?nemark system, using standard components with a machine-duplication, spark-erosion technique, is suggested.  相似文献   

2.
Single-tooth implants were used to replace congenitally absent maxillary lateral incisors in a 17-year-old patient. The inclination of the alveolar process caused a severe discrepancy between the axes of the planned implant and the crown. To avoid the need for a labial screw opening in the crown or labial overcontouring, a CeraOne abutment of the Br?nemark system was modified by selective grinding in the dental laboratory. Individual all-ceramic crowns were fabricated with the Celay In-Ceram system.  相似文献   

3.
The present experiment was performed to examine if the material used in the abutment part of an implant system influenced the quality of the mucosal barrier that formed following implant installation. 5 beagle dogs were included in the study. The mandibular premolars and the 1st, 2nd and 3rd maxillary premolars were extracted. Three fixtures of the Br?nemark System were installed in each mandibular quadrant (a total of 6 fixtures per animal). Abutment connection was performed after 3 months of healing. In each dog the following types of abutments were used: 2 "control abutments" (c.p. titanium), 2 "ceramic abutments" (highly sintered Al2O3), 1 "gold abutment", and 1 "short titanium abutment". This "short titanium abutment" was provided with an outer structure made of dental porcelain fused to gold. Following abutment connection a plaque control program was initiated and maintained for 6 months. The animals were sacrificed and perfused with a fixative. The mandibles were removed and each implant region was dissected, demineralized in EDTA and embedded in EPON. Semithin sections representing the mesial, distal, buccal and lingual aspects of the peri-implant tissues were produced and subjected to histological examination. The findings from the analysis demonstrated that the material used in the abutment portion of the implant influenced the location and the quality of the attachment that occurred between the periimplant mucosa and the implant. Abutments made of c.p. titanium or ceramic allowed the formation of a mucosal attachment which included one epithelial and one connective tissue portion that were about 2 mm and 1-1.5 mm high, respectively. At sites where abutments made of gold alloy or dental porcelain were used, no proper attachment formed at the abutment level, but the soft tissue margin receded and bone resorption occurred. The abutment fixture junction was hereby occasionally exposed and the mucosal barrier became established to the fixture portion of the implant. It was suggested that the observed differences were the result of varying adhesive properties of the materials studied or by variations in their resistance to corrosion.  相似文献   

4.
Clinical evaluations of a new porous-surfaced implant concept (Endopore) in a large population of fully and partially edentulous patients are reported, and a technique of spreading buccal and lingual plates with osteotomes to place these implants in proximity to the sinus of the posterior maxilla is described. Three-dimensional, interconnecting pores on this implant's bone interface surface give a great surface area for bone engagement. When the maxilla is prepared by this spreading procedure, these implants can be successfully placed in areas having limited available bone. Our success rates are 97.0% for implants stabilizing a mandibular overdenture and 94.8% for implants placed in partially edentulous patients. Many times, sinus lift or other augmentation procedures can be avoided in the maxilla and mandible, allowing for less patient morbidity and for an implant reconstruction that is more affordable for the patient.  相似文献   

5.
Rapid, accurate seating of screw-retained implant abutment heads, where timing is controlled by internal or external hex designs, can be readily accomplished with individual, custom-cast abutment head location devices. The devices are especially useful when the abutment head-implant body complex is to be permanently cemented. The use and design of abutment seating jigs for single tooth implants and completely implant or implant and natural tooth-supported prostheses are described.  相似文献   

6.
PURPOSE: This study evaluates a treatment regimen for reconstruction of residual maxillary alveolar cleft defects consisting of mandibular bone grafting and immediate implant installation. PATIENTS AND METHODS: Sixteen cleft patients (five female and 11 male) had residual cleft defects of the alveolar ridge reconstructed with bone grafts from the mandibular symphyseal region. The bone graft was pretapped at the donor site before fixation in the residual ridge with Br?nemark implants. Twenty implants were installed according to this concept. The period of observation ranged from 36 to 69 months, with a mean of 48 months after implant installation. RESULTS: Five patients developed wound dehiscenses that resulted in total or partial bone graft sequestration. Two implants were lost, one due to sequestration and the other due to mobility at the abutment procedure; 18 implants were still well functioning at the end of the observation period. However, all patients showed significant periimplant bone resorption after this one-stage treatment. CONCLUSION: Because of the observed complication rate, the one-stage procedure may not be optimal for reconstructing residual cleft defects.  相似文献   

7.
Some adult cleft palate patients show severe maxillary transverse contraction and posterior crossbite. This case report demonstrates successful surgical-orthodontic treatment of such a patient. Surgically assisted rapid maxillary expansion (SA-RME) was completed prior to comprehensive orthodontic treatment. The osteotomy was performed on both the buccal and lingual aspects of the posterior maxillary alveolus. A Hyrax-type maxillary-expansion appliance was used, and the screw (0.2 mm, one quarter turn) was turned two or three times per day. Comprehensive orthodontic treatment was initiated after extraction of the mandibular first premolars and four third molars. The maxillary lateral incisors were also extracted after active orthodontic treatment. The amount of expansion achieved using SA-RME was greater at the posterior than at the anterior maxilla. Midpalatal suture opening occurred. After orthodontic treatment, occlusal stability was satisfactory. This case demonstrates the effectiveness of SA-RME in adult cleft palate patients with severe posterior crossbite.  相似文献   

8.
Traditionally, the procedure of implant placement requires a surgical periosteal flap to be raised. In a percentage of implant cases, there is no need for flap surgery for implant placement, or for a follow-up surgical procedure for abutment connection. In this clinical investigation, 20 maxillary and mandibular implants were placed in seven adult male patients. The sites for implant placement were prepared according to an alternative surgical technique without raising a surgical flap. Patients were recalled periodically for 2 years to evaluate healing and clinical integration of implants. The results showed normal clinical healing at the first week of reexamination in all implant sites; periodontal probing of less than 2 mm circumferentially around all healing caps at 3 months and later at subsequent recall periods; no radiolucency observed in the peri-implant zone; no sign of clinical mobility during recall examination; and no persistent or irreversible sign or symptoms of pain, infection, or necrosis. This alternative surgical technique can provide several advantages over the traditional 2-step procedure.  相似文献   

9.
A 53-year-old male with a history of initial oral facial trauma causing the loss of three maxillary incisors, multiple failures of tooth-borne fixed prosthetic reconstructions, and a resultant condition of structural failure of abutment cuspids and lateral incisor was to be retreated. The case contained numerous anatomic and dimensional constraints. The patient's desire to achieve a long-term, dependable prosthetic reconstruction prompted professional consideration of incorporating implants to lend structural support in the edentulous area. An extensive review of current implant-abutment options and their single-tooth implant replacement design and treatment rationales was conducted. The IMZ Generation III (IMZTwinPlus) implant system, a nonhex system, was chosen for treatment of the case of report to optimize mechanics, biomechanics, and esthetics for multiple individual-tooth implant replacement.  相似文献   

10.
A new design of single tooth implant (AstraTech, Molndal Sweden) featuring a microthreaded conical neck and TiO blast surface was evaluated clinically and radiographically after 2 years in function. Fifteen patients (age range 16 to 48) with missing maxillary anterior teeth (6 central incisors, 8 laterals, 1 bicuspid) had 4, 13 mm and 11, 15 mm implants placed under local anaesthesia and left for a period of 6 months before exposure and abutment connection/crown fabrication. All patients were seen at 4 to 6 monthly intervals for hygienist maintenance. Radiographs using Rinn holders and a long cone technique were taken at the crown insertion and after 1 year (14 subjects) and 2 years (12 subjects). All implants were successfully integrated at stage 2, and no implants have been lost. The internal conical seal design of the abutment/implant interface facilitated connection and there were no cases of abutment screw loosening. No soft tissue problems were observed, and the gingival morphology/health was well maintained. One crown was recemented after 18 months in function, and 1 crown was replaced because of a fracture to the porcelain incisal edge. At crown insertion, the mean bone level was 0.46 to 0.48 mm apical to the top of the implant and there were no statistically significant changes in the bone level over the 2 years of the study. In conclusion, the single tooth Astra implants were highly successful and bone changes within the first 2 years of function were comparable with other systems reporting high long-term success rates.  相似文献   

11.
The specific aim of this study was to determine the response of alveolar bone after it was augmented vertically using distraction osteogenesis and subsequently loaded with implant restorations. Four dogs each had four implants placed horizontally into an edentulous mandibular quadrant and, after integration, a distraction osteogenesis device was fabricated in the laboratory. An osteotomy was made to allow the crest of the alveolar ridge to be distracted vertically. After 10 mm of vertical distraction, the device was stabilized with light cured resin. Following bone fill confirmation of the distraction gap at 10 weeks, two implants were placed into the ridges, one in distracted bone and one in nondistracted bone. After 4 months for implant integration, freestanding prostheses were fabricated. Crestal bone levels were evaluated throughout the period of function. Animals were sacrificed after 1 year of loading, for histologic evaluation of the bone. The vertical ridge augmentation averaged 8.85 +/- 1.05 mm after 10 weeks of healing following distraction, without change over 1 year of implant loading. Histologic examination showed that bone had formed between the distracted segments, creating an augmented ridge. The average thickness of the labial cortex in the distraction gap was significantly thinner than the lingual cortex in distracted bone and the lingual and labial nondistracted cortical bone. The presence of the dental implant did not significantly affect cortical bone thickness. Serial sections showed that implants remained integrated and functional without soft tissue inflammation. Dental implants placed into alveolar ridges augmented with the technique of distraction osteogenesis maintained bone and were functional for the length of this study.  相似文献   

12.
This investigation was initiated to develop a method to provide patients with a fixed provisional prosthesis placed at the time of implant placement. Sixty-three standard 3.75-mm Nobel Biocare implants of varying lengths were placed into mandibular sites in 10 patients and followed for up to 10 years. Twenty-eight implants were immediately loaded at implant placement, providing support for fixed provisional prostheses, while 35 adjacent implants were allowed to heal submerged and stress-free. Following a 3-month healing period, the submerged implants were exposed and definitive reconstruction was accomplished. All 10 prostheses supported by 28 implants placed into immediate function at the time of implant placement were successful during the 3-month healing period. Of these 28 implants placed into immediate function, 4 ultimately failed. Of the 35 submerged implants, all are osseointegrated and in function to date. Life-table analysis demonstrates an overall 10-year survival rate of 93.4% for all implants. The 10-year life-table analysis of survival is 84.7% for immediately loaded implants and 100% for submerged implants. Statistical analysis of the submerged versus immediately loaded implants demonstrates failure rates for immediately loaded implants to be significantly higher (P = .022 by the log rank test). These data demonstrate that although mandibular implants can be successfully placed into immediate function in the short term to support fixed provisional prostheses, long-term prognosis is guarded for those implants placed into immediate function distal to the incisor region.  相似文献   

13.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

14.
STATEMENT OF PROBLEM: Implant-supported restorations in the partially edentulous jaw have been performed at the Mayo Clinic for more than 10 years. Clinical performance of the implants and the prostheses should be reported to ensure effectiveness of this procedure. PURPOSE: This retrospective study described results for implant survival, implant fracture rate, prosthetic complications, and design changes that may impact these results. MATERIAL AND METHODS: A retrospective chart review was conducted of all registered implant patients in a large multispecialty medical center. Patients with a partially edentulous jaw who had received endosseous implants to support and retain dental prostheses were included in this review. Implant survival and fracture, prosthetic complications, and demographic data were recorded and analyzed through Kaplan-Meier methods. RESULTS: A total of 1170 implants were placed in four anatomic locations: anterior maxilla, posterior maxilla, anterior mandible, or posterior mandible. Location of implants was shown to have no effect on implant survival (p = 0.7398), implant fracture rates (p = 0.2385), screw loosening (p = 0.8253), or screw fracture (p = 0.2737). Development of new restorative components has resulted in significantly better rates of implant survival without fracture (p = 0.0054), screw function without loosening (p < 0.0001) and screw function without fracture (p = 0.0013). Implant survival seems to have been improved with the new components (p = 0.0513). CONCLUSIONS: Implant survival in this study was independent of anatomic location of implants. Virtually all clinical performance factors were improved by design changes in implant restorative components that were brought to market in early 1991.  相似文献   

15.
PURPOSE: This study focuses on the curvature and inclination of the lingual surfaces of the maxillary anterior teeth from the transition point on the cingulum to the incisal edge. MATERIALS AND METHODS: On 32 sets of mounted casts, 768 measurements were made of the curvature of the lingual surfaces utilizing radius gauges. The inclination of the lingual surface relative to the occlusal plane was recorded. The relationship of the incisal edge of the mandibular teeth to the transition point on the cingulum of the maxillary teeth was determined. Centric occlusion contact was noted on each tooth. RESULTS: Significant differences were found between the measured areas of any one tooth and between the types of teeth. The average radius ranged from 20.5 mm on the mesial ridge of the canine to 5.3 mm in the fossa of the central. The average inclination of the lingual surfaces was 46 degrees. In centric occlusion, 97% of the canines and 59% of the centrals and laterals were in contact with the opposing teeth. These contacts occurred 2.8 mm incisal to the transition point. The centrals contracted two opposing teeth (45%), and canines contacted one opposing tooth (53%). CONCLUSIONS: The function and curvature of the incisor teeth vary considerably from those of the canines. Overcontouring the lingual surfaces of the maxillary incisors to gain contact is not normal and may be detrimental.  相似文献   

16.
17.
A patient with a severely atrophic right posterior mandible had three endosseous implants placed in conjunction with transposition of the inferior alveolar nerve. Three weeks following implant placement surgery, the patient experienced a spontaneous fracture of the mandible involving the two anterior implants. The two implants were removed, and the fracture was treated with open reduction and fixation with titanium mesh. The fracture healed, and the posterior implant integrated. This report suggests that the buccolingual and superior-inferior position of the mandibular canal can increase the possibility of mandibular fracture by increasing the size of the buccal cortical plate that is removed to expose the nerve during surgery.  相似文献   

18.
Roughened implant surfaces are thought to enhance osseointegration. Torque removal forces have been used as a biomechanical measure of anchorage or osseointegration in which the greater forces required to remove implants may be interpreted as an increase in the strength of osseointegration. The purpose of this study was to compare the torque resistance to removal of screw shaped titanium implants having an acid etched (HC1/H2SO4) surface (Osseotite) with implants having a machined surface. Two custom screw shaped implants, 1 acid etched and the other machined, were placed into the distal femurs of 10 adult New Zealand White rabbits. These implants were 3.25 mm in diameter x 4.00 mm in length without holes, grooves or slots to resist rotation. Following a 2 month healing period, the implants were removed under reverse torque rotation with a digital torque measuring device. Two implants with the machined surface preparation failed to achieve osseointegration. All other implants were found to be anchored to bone. Resistance to torque removal was found to be 4 x greater for the implants with the acid etched surface as compared to the implants with the machined surface. The mean torque values were 20.50 +/- 6.59 N cm and 4.95 +/- 1.61 N cm for the acid etched and machined surfaces respectively. The results of this study suggest that chemical etching of the titanium implant surface significantly increases the strength of osseointegration as determined by resistance to reverse torque rotation.  相似文献   

19.
The possibility of placing endosseous implants in the edentulous maxilla is frequently reduced by inadequate bone volume of the residual ridge. In totally edentulous maxillae with knife-edge conformation, insufficient thickness is frequently associated with insufficient height of the residual ridge in the posterior maxilla because of pneumatization of the maxillary sinuses. This surgical method combines grafting of the maxillary sinuses, onlay grafts on the buccal side of maxillary posterior segments, and sagittal osteotomy of the anterior maxilla with interpositional bone grafts. Five to six months after maxillary reconstruction, Br?nemark implants were placed and, after osseointegration occurred, implant-supported dental prostheses were fabricated. Three patients have been treated with this method and 22 implants have been placed. The mean follow-up after final prosthetic rehabilitation has been 16 months; survival rate has been 100%. Despite the small number of patients and the short follow-up, preliminary results have shown very promising results.  相似文献   

20.
Lingual orthodontics presents a few technical problems; when practicing it, it reveals a considerable amount of advantages. The occlusal interference of the lingual maxillary bite plane with the mandibular incisors generate contact forces. A moment of corono-vestibulary version will weight upon the upper incisor independently from teeth position. Actions regarding the mandibulary incisors are depending on their position according to the bite plane. An incisor axe in perpendicular position to the plan generates intrusion. A lingual position generates a moment of lingual version and vice versa. These actions have to be considered. They might be, according to clinical situation, beneficial or not.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号