首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liu G  Lin Y 《Analytical chemistry》2005,77(18):5894-5901
An electrochemical sensor for detection of organophosphate (OP) pesticides and nerve agents using zirconia (ZrO2) nanoparticles as selective sorbents is presented. Zirconia nanoparticles were electrodynamically deposited onto the polycrystalline gold electrode by cyclic voltammetry. Because of the strong affinity of zirconia for the phosphoric group, nitroaromatic OPs strongly bind to the ZrO2 nanoparticle surface. The electrochemical characterization and anodic stripping voltammetric performance of bound OPs were evaluated using cyclic voltammetric and square-wave voltammetric (SWV) analysis. SWV was used to monitor the amount of bound OPs and provide simple, fast, and facile quantitative methods for nitroaromatic OP compounds. The sensor surface can be regenerated by successively running SWV scanning. Operational parameters, including the amount of nanoparticles, adsorption time, and pH of the reaction medium have been optimized. The stripping voltammetric response is highly linear over the 5-100 ng/mL (ppb) methyl parathion range examined (2-min adsorption), with a detection limit of 3 ng/mL and good precision (RSD = 5.3%, n = 10). The detection limit was improved to 1 ng/mL by using 10-min adsorption time. The promising stripping voltammetric performances open new opportunities for fast, simple, and sensitive analysis of OPs in environmental and biological samples. These findings can lead to a widespread use of electrochemical sensors to detect OP contaminates.  相似文献   

2.
A differential pulse anodic stripping voltammetric (DPASV) method was used to differentiate between the cadmium species Cd(2+) and MeCd(+) (Me = methyl) in aquatic systems. These two species show peaks in the DPASV voltammogram which differ by 112 mV. In model experiments, it was demonstrated that monomethylcadmium is not stable at pH 2, but under higher pH conditions, normally found in fresh and ocean water samples, the identity of MeCd(+) was verified by different investigations, including cyclic voltammetry, selective extraction of a complex of diethyldithiocarbamate with MeCd(+) into n-hexane, and photochemical dissociation of MeCd(+) by UV irradiation. It was also shown that humic acids do not influence the voltammetric determination of monomethylcadmium. For the first time, it was possible to analyze MeCd(+) in environmental samples. During different expeditions with the German research vessel Polarstern, monomethylcadmium could be determined above the detection limit of 470 pg L(-1) in nearly all surface water samples of the South Atlantic with spot concentrations of up to about 700 pg L(-1), whereas in the North Atlantic only 15-30% of the total samples showed MeCd(+) concentrations above this limit. The existence of MeCd(+) in the remote area of the South Atlantic, as well as positive correlations with the local bioactivity in the ocean, indicates biomethylation as the most probable formation process for this methylated cadmium species. This assumption is supported by the simultaneous occurrence of other methylated heavy metal compounds, such as Me(3)Pb(+). Up to 48% of the total cadmium was found to be monomethylcadmium in some Arctic meltwater ponds.  相似文献   

3.
We have successfully developed electrochemical sensors based on functionalized nanostructured materials for voltammetric analysis of toxic metal ions. Glycinylurea self-assembled monolayers on mesoporous silica (Gly-UR SAMMS) were incorporated in carbon paste electrodes for the detection of toxic metal ions such as lead, copper, and mercury based on adsorptive stripping voltammetry (AdSV). The electrochemical sensor yields a linear response at a low ppb level of Pb2+ (i.e., 2.5-50 ppb) after a 2-min preconcentration period, with reproducible measurements (%RSD = 3.5, N = 6) and an excellent detection limit (1 ppb). By exploiting the interfacial functionality of Gly-UR SAMMS, the sensor is selective for the target species, does not require the use of a mercury film, and can be easily regenerated in dilute acid solution. The rigid, open, parallel pore structure, combined with suitable interfacial chemistry of SAMMS, also results in fast analysis times (2-3 min). The nanostructured SAMMS materials enable the development of miniature sensing devices that are compact and low cost, have low energy consumption, and are easily integrated into field-deployable units.  相似文献   

4.
Song Y  Swain GM 《Analytical chemistry》2007,79(6):2412-2420
We demonstrate that a Au-coated, boron-doped, diamond thin-film electrode provides a sensitive, reproducible, and stable response for total inorganic arsenic (As(III) and As(V)) using differential pulse anodic stripping voltammetry (DPASV). As is preconcentrated with Au on the diamond surface during the deposition step and detected oxidatively during the stripping step. Au deposition was uniform over the electrode surface with a nominal particle size of 23 +/- 5 nm and a particle density of 109 cm-2. The electrode and method were used to measure the As(III) concentration in standard and river water samples. The detection figures of merit were compared with those obtained using conventional Au-coated glassy carbon and Au foil electrodes. The method was also used to determine the As(V) concentration in standard solutions after first being chemically reduced to As(III) with Na2SO3, followed by the normal DPASV determination of As(III). Sharp and symmetric stripping peaks were generally observed for the Au-coated diamond electrode. LODs were 0.005 ppb (S/N = 3) for As(III) and 0.08 ppb (S/N = 3) for As(V) in standard solutions. An As(III) concentration of 0.6 ppb was found in local river water. The relative standard deviation of the As stripping peak current for river water was 1.5% for 10 consecutive measurements and was less than 9.1% over a 10-h period. Excellent electrode response stability was observed even in the presence of up to 5 ppm of added humic acid. In summary, the Au-coated diamond electrode exhibited better performance for total inorganic As analysis than did Au-coated glassy carbon or Au foil electrodes. Clearly, the substrate on which the Au is supported influences the detection figures of merit.  相似文献   

5.
With the aim of producing a general purpose sensor for environmental analysis, we describe a simple and sensitive method for organohalide detection, based on an electrochemical collector-generator process. The sensor consists of four coplanar electrodes contacting a solution volume of 300 microL, containing organohalide. At the first working electrode (a Zn/PTFE composite), the analyte is electrolyzed to liberate halide ions. At the second working electrode (Ag), the halide ions are detected by cathodic stripping voltammetry. Using a preconcentration time of 600 s, with differential pulse voltammetry for stripping, the responses to 1-chloropropane, chloroform, carbon tetrachloride, iodoethane, and bromoethane can be plotted on a common calibration curve, with a detection limit of 0.1 nM (1.3 pg L(-1) or less depending on the organohalide). To the best of our knowledge, this is the lowest reported organohalide detection limit by an electrochemical method and is so far the only general purpose electrochemical method sensitive enough for regulatory requirements. The sensor response was invariant for approximately 40 measurements. Analysis of tap water, spiked with chloroform or carbon tetrachloride, gave recoveries within 1.0-2.6% of the recoveries by the standard GC method.  相似文献   

6.
Electrochemical adsorption and voltammetry of hen-egg-white-lysozyme (HEWL) was studied at an array of microinterfaces between two immiscible electrolyte solutions (μITIES). Adsorption of the protein was achieved at an optimal applied potential of 0.95 V, after which it was desorbed by a voltammetric scan to lower potentials. The voltammetric peak recorded during the desorption scan was dependent on the adsorption time and on the aqueous phase concentration of HEWL. The slow approach to saturation or equilibrium indicated that protein reorganization at the interface was the rate-determining step and not diffusion to the interface. For higher concentrations and longer adsorption times, a HEWL multilayer surface coverage of 550 pmol cm(-2) was formed, on the basis of the assumption that a single monolayer corresponded to a surface coverage of 13 pmol cm(-2). Implementation of adsorption followed by voltammetric detection as an adsorptive stripping voltammetric approach to HEWL detection demonstrated a linear dynamic range of 0.05-1 μM and a limit of detection of 0.03 μM, for 5 min preconcentration in unstirred solution; this is a more than 10-fold improvement over previous HEWL detection methods at the ITIES. These results provide the basis for a new analytical approach for label-free protein detection based on adsorptive stripping voltammetry.  相似文献   

7.
In this work, the organic compound 2-mercaptobenzimidazole was covalently bound on the surface of a glassy carbon rod, via silanization, yielding a material capable of selectively complexing Hg(2+) ions. This material was applied as an electrode for voltammetric determination of mercury(II) following its nonelectrolytic preconcentration. After exchanging the medium, the voltammetric measurements were carried out by anodic stripping in the differential pulse mode (pulse amplitude, 50 mV; scan rate, 1.25 mV s(-)(1)) using 10(-)(2) mol L(-)(1) NaSCN solution as supporting electrolyte. An anodic stripping peak was obtained at 0.06 V (vs SCE) by scanning the potential from -0.3 to +0.3 V. After a 5 min preconcentration period in a pH 4.0 Hg(2+) solution, this electrode shows increasing voltammetric response in the range 0.1-2.2 μg mL(-)(1), with a relative standard deviation of 5% and a practical detection limit of 0.1 μg mL(-)(1) (5.0 × 10(-)(7) mol dm(-)(3)). Compared with the conventional stripping approach, this chemically modified glassy carbon electrode procedure presented good discrimination against interference from Cu(II) in up to 10-fold molar excess.  相似文献   

8.
Nanowires of poly-cobalt[tetrakis(o-aminophenyl)porphyrin] (PCoTAPPNW) were fabricated by electrochemical polymerization by the cyclic voltammetric method in anodic aluminum oxide membranes. A glassy carbon electrode (GCE) modified by PCoTAPPNW and single-walled carbon nanotubes (SWNT) without any binder was investigated with voltammetric methods in phosphate buffer saline (PBS) at pH 7.4. The PCoTAPPNW + SWNT/GCE exhibited strongly enhanced voltammetric and amperometric sensitivity towards hydrogen peroxide (H2O2), which shortened the response time (< 5 seconds), showed detection limit of 1.0 microM and enhanced the sensitivity for H2O2 detection with 194 microA mM(-1) cm(-2). The PCoTAPPNW + SWNT/GCE can be used to monitor H2O2 at very low concentration in physiological pH as an efficient electrochemical H2O2 sensor.  相似文献   

9.
Cui R  Pan HC  Zhu JJ  Chen HY 《Analytical chemistry》2007,79(22):8494-8501
A versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels has been developed for sensitive protein detection. This sandwich-type sensor is fabricated on an indium tin oxide chip covered with a well-ordered gold nanoparticle monolayer. Gel imaging systems were successfully introduced to develop a novel high-efficient optical immunoassay, which could perform simultaneous detection for the samples with a series of different concentrations of a target analyte. The linear range of this assay was between 0.1 and 500 ng/mL, and the assay sensitivity could be further increased to 0.005 ng/mL with the linear range from 0.005 to 100 ng/mL by stripping voltammetric analysis. The immunosensor showed good precision, high sensitivity, acceptable stability, and reproducibility and could be used for the detection of real sample with consistent results in comparison with those obtained by the ELISA method.  相似文献   

10.
An electrochemical immunoassay for cardiac troponin I (cTnI) combining the concepts of the dual monoclonal antibody "sandwich" principle, the silver enhancement on the nano-gold particle, and the anodic stripping voltammetry is described. Four main steps were carried out to obtain the analytical signal, i.e., electrode preparation, immunoreaction, silver enhancement, and anodic stripping voltammetric detection. A linear relationship between the anodic stripping peak current and concentration of cTnl from 1 to 20 ng/ml and a limit of detection of 0.8 ng/ml were obtained. The established method was tested by determining cTnI in acute myocardial infarction (AMI) samples using enzyme-linked immunoadsorbent assay (ELISA) for comparison analysis, and good results were obtained.  相似文献   

11.
An ultrasensitive immunodiagnostic readout method based on an electrochemical analysis is presented. Different inorganic quantum dot (QD) nanocrystals (ZnS, CdS, and PbS) are tagged to antibodies for the on-site voltammetric stripping measurements of multiple antigen targets. The multiprotein electrical sensing capability is coupled to the amplification feature of anodic stripping voltammetric transduction and with an efficient magnetic removal (to minimize nonspecific adsorption and cross-reactivity effects). Sandwich-immunoassay formats were performed using model proteins (/spl beta//sub 2/-microglobulin, myoglobin, and human serum albumin). These encoding QD tracers with distinct redox potential yield highly sensitive and selective stripping peaks at -1.11 V (Zn), -0.67 V (Cd), and -0.52 V (Pb) at the mercury-film screen printed carbon electrode (versus Ag/AgCl reference). The position and size of these peaks reflect the identity and risk level of the corresponding antigen marker. The favorable signal-to-noise characteristics of the response for the initial 25-ng/mL mixture indicate a detection limit of ca. 10 ng/mL far below the early warning range and allow a reliable determination of very low protein concentrations. Such analog peaks of the QDs were converted to simple and rapid barcode signals. The digital readout system can code 215 electrically tuned barcodes to mark different protein analytes and to be useful for a wireless communication system.  相似文献   

12.
Liu G  Lin YY  Wang J  Wu H  Wai CM  Lin Y 《Analytical chemistry》2007,79(20):7644-7653
We describe a disposable electrochemical immunosensor diagnosis device that integrates the immunochromatographic strip technique with an electrochemical immunoassay and exploits quantum dot (QD, CdS@ZnS) as labels for amplifying signal output. The device takes advantage of the speed and low cost of the conventional immunochromatographic strip test and the high sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1-10 ng mL(-1) IgG, and the limit of detection is estimated to be 30 pg mL(-1) in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL(-1) using a 20-min immunoreaction time. The device has been successfully applied for the detection of prostate-specific antigen (PSA) in human serum sample with a detection limit of 20 pg mL(-1). The results were validated by using the commercial PSA enzyme-linked immunosorbent assay kit and showed high consistency. The new disposable electrochemical diagnosis device thus provides a rapid, clinically accurate, and quantitative tool for protein biomarker detection.  相似文献   

13.
A particle-based renewable electrochemical magnetic immunosensor was developed by using magnetic beads and gold nanoparticle labels. Anti-IgG antibody-modified magnetic beads were attached to a renewable carbon paste transducer surface by magnet that was fixed inside the sensor. Gold nanoparticle labels were capsulated to the surface of magnetic beads by sandwich immunoassay. Highly sensitive electrochemical stripping analysis offers a simple and fast method to quantify the capatured gold nanoparticle tracers and avoid the use of an enzyme label and substrate. The stripping signal of gold nanoparticles is related to the concentration of target IgG in the sample solution. A transmission electron microscopy image shows that the gold nanoparticles were successfully capsulated to the surface of magnetic beads through sandwich immunoreaction events. The parameters of immunoassay, including the loading of magnetic beads, the amount of gold nanoparticle conjugate, and the immunoreaction time, were optimized. The detection limit of 0.02 microg ml(-1) of IgG was obtained under optimum experimental conditions. Such particle-based electrochemical magnetic immunosensors could be readily used for simultaneous parallel detection of multiple proteins by using multiple inorganic metal nanoparticle tracers and are expected to open new opportunities for disease diagnostics and biosecurity.  相似文献   

14.
Zhang HX  Cao AM  Hu JS  Wan LJ  Lee ST 《Analytical chemistry》2006,78(6):1967-1971
An electrochemical sensor for ultratrace nitroaromatic compounds (NACs) using mesoporous SiO2 of MCM-41 as sensitive materials is reported. MCM-41 was synthesized and characterized by scanning electron microscope, transmission electron microscopy, and small-angle X-ray diffraction. Glassy carbon electrodes modified with MCM-41 show high sensitivity for cathodic voltammetric detection of NACs (including 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitrobenzene (TNB), 2,4-dinitrotoluene, and 1,3-dinitrobenzene) down to the nanomolar level. The high sensitivity is attributed to the strong adsorption of NACs by MCM-41 and large surface area of the working electrode resulting from MCM-41 modification. The voltammetric response is fast, and the detection of NACs can be finished within 14 s. SiO2 nanospheres were similarly used to modify glassy carbon electrodes for electrochemical detection of TNT and TNB. The detection limit of SiO2 nanosphere-modified electrodes is lower than that of MCM-41-modified electrodes, possibly due to the smaller surface area of SiO2 nanospheres than mesoporous MCM-41. The results show mesoporous SiO2-modified glassy carbon electrodes, particularly MCM-41-modified electrodes, open new opportunities for fast, simple, and sensitive field analysis of NACs.  相似文献   

15.
Kim Y  Amemiya S 《Analytical chemistry》2008,80(15):6056-6065
A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode is based on the submicrometer-thick plasticized poly(vinyl chloride) membrane spin-coated on the poly(3-octylthiophene)-modified gold electrode. The liquid membrane serves as the first thin-layer cell for ion-transfer stripping voltammetry to give low detection limits of 0.2-0.5 nM perchlorate in deionized water, commercial bottled water, and tap water under a rotating electrode configuration. The detection limits are not only much lower than the action limit (approximately 246 nM) set by the U.S. Environmental Protection Agency but also are comparable to the detection limits of the most sensitive analytical methods for detecting perchlorate, that is, ion chromatography coupled with a suppressed conductivity detector (0.55 nM) or electrospray ionization mass spectrometry (0.20-0.25 nM). The mass transfer of perchlorate in the thin-layer liquid membrane and aqueous sample as well as its transfer at the interface between the two phases were studied experimentally and theoretically to achieve the low detection limits. The advantages of ion-transfer stripping voltammetry with a thin-layer liquid membrane against traditional ion-selective potentiometry are demonstrated in terms of a detection limit, a response time, and selectivity.  相似文献   

16.
A simple portable handheld electrochemical sensor with an integrated sound source for the detection of ultratrace quantities of arsenic using square wave anodic stripping voltammetry is described. The sensor uses low-frequency sound (250 Hz) during the arsenic deposition step to enhance the sensitivity of the arsenic stripping response. It is found that under quiescent (silent) conditions a detection limit of 2.1 x 10(-7) M with a sensitivity of 0.51 M(-1) A is achievable using a 120-s accumulation period, while applying low-frequency sound using a "sonotrode" reduced this detection limit to 3.7 x 10(-9) M with an increased sensitivity of 27.2 M(-1) A. Thus, the low-frequency sonotrode is shown to increase the sensitivity by ca. 50 times while reducing the limit of detection by 2 orders of magnitude. A study of the effect of copper contamination is carried out as well as analysis in real samples; it is found that although as expected copper detrimentally effects the arsenic limit of detection, it does not rise significantly above 10(-8) M levels.  相似文献   

17.
Microfluidic chip devices are shown to be attractive platforms for performing microscale voltammetric analysis and for integrating voltammetric procedures with on-chip chemical reactions and fluid manipulations. Linear-sweep, square-wave, and adsorptive-stripping voltammograms are recorded while electrokinetically "pumping" the sample through the microchannels. The adaptation of voltammetric techniques to microfluidic chip operation requires an assessment of the effect of relevant experimental variables, particularly the high voltage used for driving the electroosmotic flow, upon the background current, potential window, and size or potential of the voltammetric signal. The exact potential window of the chip detector is dependent upon the driving voltage. Manipulation of the electroosmotic flow opens the door to hydrodynamic modulation (stopped-flow) and reversed-flow operations. The modulated analyte velocity permits compensation of the microchip voltammetric background. Reversal of the driving voltage polarity offers extended residence times in the detector compartment. Rapid square-wave voltammetry/flow injection operation allows a detection limit of 2 x 10(-12) mol (i.e., 2 pmol) of 2,4,6-trinitrotoluene (TNT) in connection with 47 nL of injected sample. The ability of integrating chemical reactions with voltammetric detection is demonstrated for adsorptive stripping measurements of trace nickel using the nickel-dimethylglyoxime model system. The voltammetric response is characterized using catechol, hydrazine, TNT, and nickel as test species. The ability to perform on-chip voltammertic protocols in advantageous over nanovial voltammetric operations that lack a liquid-handling capability. Coupling the versatility of microfluidic chips with the rich information content of voltammetry thus opens an array of future opportunities.  相似文献   

18.
Du D  Wang J  Wang L  Lu D  Smith JN  Timchalk C  Lin Y 《Analytical chemistry》2011,83(10):3770-3777
We report a new approach for electrochemical quantification of enzymatic inhibition and phosphorylation for biomonitoring of exposure to organophosphorus (OP) pesticides and nerve agents based on a magnetic bead (MB) immunosensing platform. The principle of this approach is based on the combination of MB immunocapture-based enzyme activity assay and competitive immunoassay of the total amount of enzyme for simultaneous detection of enzyme inhibition and phosphorylation in biological fluids. Butyrylcholinesterase (BChE) was chosen as a model enzyme. In competitive immunoassay, the target BChE in a sample competes with the BChE immobilized on the MBs to bind to the limited sites of anti-BChE antibody labeled with quantum dots (QD-anti-BChE), followed by stripping voltammetric analysis of the bound QD conjugate on the MBs. This assay shows a linear response over the total BChE concentration range of 0.1-20 nM. Simultaneous real time BChE activity was measured on an electrochemical carbon nanotube-based sensor coupled with a microflow injection system after immunocapture by the MB-anti-BChE conjugate. Therefore, the formed phosphorylated BChE adduct (OP-BChE) can be estimated by the difference values of the total amount of BChE (including active and OP-inhibited) and active BChE from established calibration curves. This approach not only eliminates the difficulty in screening of low-dose OP exposure (less than 20% inhibition of BChE) because of individual variation of BChE values but also avoids the drawback of the scarce availability of OP-BChE antibody. It is sensitive enough to detect 0.5 nM OP-BChE, which is less than 2% BChE inhibition. This method offers a new method for rapid, accurate, selective, and inexpensive quantification of OP-BChE and enzyme inhibition for biomonitoring of OP and nerve agent exposures.  相似文献   

19.
郭吉鹏  卢立新  潘嘹  卢莉璟 《包装工程》2022,43(23):174-181
目的 将分子印迹技术与电化学相结合,实现食品接触材料中4,4''–二氨基二苯甲烷(DDM)的快速检测。方法 采用分子印迹技术,以羧基化碳纳米管(OH–MWCNT)为增敏材料,分别以DDM和吡咯(PPY)作为模板分子和功能单体,在玻璃碳电极(GCE)表面电沉积制备DDM印迹分子薄膜(MIP),对印迹电极的检测能力使用扫描电镜(SEM)和电化学分析法进行表征。结果 电沉积的DDM电化学传感器具有优良的检测性能和可重复性,其线性范围为10~50 μmol/L,检出限为116 ng/L。结论 该方法具备操作简单、精度高、速度快等优点,能够实现对食品接触材料中DDM的痕量检测。  相似文献   

20.
A new procedure for the direct determination of picomolar levels of iron in seawater is presented. Cathodic stripping voltammetry (CSV) is preceded by adsorptive accumulation of the iron(III)-2,3-dihydroxynaphthalene (DHN) complex from seawater, containing 20 microM DHN at pH 8.0, onto a static mercury drop electrode, followed by reduction of the adsorbed species. The reduction current is catalytically enhanced by the presence of 20 mM bromate. Optimized conditions include a 60-s adsorption period at -0.1 V and a voltammetric scan using sampled dc modulation at 10 Hz. In these conditions, a detection limit of 13 pM iron in seawater was achieved which can be lowered further by extending the adsorption time to 300 s. The new catalytic CSV method is approximately 5 times more sensitive than existing CSV methods and was tested on samples from the Atlantic Ocean.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号