首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study energy, exergy and exergoeconomic analysis of the Afyon geothermal district heating system (AGDHS) in Afyon, Turkey is performed through thermodynamic performances and thermo-economic assessments. In the analysis, actual system data are used to assess the district heating system performance, energy and exergy efficiencies, exergy losses and loss cost rates. Energy and exergy losses throughout the AGDHS are quantified and illustrated in the flow diagram. The energy and exergy efficiencies of the overall system are found to be 37.59% and 47.54%, respectively. The largest exergy loss occurs in the heat exchangers with 14.59% and then in the reinjection wells with 14.09%. Besides, thermo-economic evaluations of the AGDHS are given in table. Energy and exergy loss rates for the AGDHS are estimated to be 5.36 kW/$ and 0.2  kW/$, respectively.  相似文献   

2.
A proposed hybrid solar hydrogen system with activated carbon storage for residential power generation is assessed using exergy analysis. Energy and exergy balances are applied to determine exergy flows and efficiencies for individual devices and the overall system. A ‘base case’ analysis considers the proposed system without modification, while a ‘modified case’ extends the base case by considering the possibility of multiple product outputs. It is determined that solar photovoltaic-based sub-systems have the lowest exergy efficiencies (14-18%) and offer the most potential for improvement. A comparison of these two scenarios shows that the additional outputs raise the exergy efficiency of the modified case (11%) relative to the base case (4.0%). An investigation of the energy and exergy efficiencies of separate devices illustrates how energy analyses can be misleading. The hybrid system is expected to have several environmental benefits, which may offset to some degree economic barriers to implementation.  相似文献   

3.
In this paper, energy and exergy analyses for a 1.2 kWp Nexa PEM fuel cell unit in a solar-based hydrogen production system is undertaken to investigate the performance of the system for different operating conditions using experimental setup and thermodynamic model. From the model results, it is found that there are reductions in energy and exergy efficiencies (about 14%) with increase in current density. These are consistent with the experimental data for the same operating conditions. A parametric study on the system and its parameters is undertaken to investigate the changes in the efficiencies for variations in temperature, pressure and anode stoichiometry. The energy and exergy efficiencies increase with pressure by 23% and 15%, respectively. No noticeable changes are observed in energy and exergy efficiencies with increase in temperature. The energy and exergy efficiencies decrease with increase in anode stoichiometry by 17% and 14%, respectively. These observations are reported for the given range of current density as 0.047–0.4 A/cm2. The results and analyses show that the PEM fuel-cell system has lower exergy efficiencies than the corresponding energy efficiencies due to the irreversibilities that are not considered by energy analysis. In comparison with experimental data, the model is accurate in predicting the performance of the proposed fuel-cell system. The parametric and multivariable analyses show that the option of selecting appropriate set of conditions plays a significant role in improving performance of existing fuel-cell systems.  相似文献   

4.
In this study, we investigate a solar-assisted biomass gasification system for hydrogen production and assess its performance thermodynamically using actual literature data. We also analyze the entire system both energetically and exergetically and evaluate its performance through both energy and exergy efficiencies. Three feedstocks, namely beech charcoal, sewage sludge and fluff, are considered as samples in the same reactor. While energy efficiencies vary from 14.14% to 27.29%, exergy efficiencies change from 10.43% to 23.92%. We use a sustainability index (SI), as a function of exergy efficiency, to calculate the impacts on sustainable development and environment. This index changes from 1.12 to 1.31 due to intensive utilization of solar energy. Also, environmental impact of these systems is evaluated through calculating the specific greenhouse gas (GHG) emissions. They are determined to be 17.97, 17.51 and 26.74 g CO2/MJ H2 for beech charcoal, sewage sludge and fluff, respectively.  相似文献   

5.
In this paper, the energy, exergy, economic, environmental, steady-state, and process performance modeling/analysis of hybrid renewable energy (RE) based multigeneration system is presented. Beyond the design/performance analysis of an innovative hybrid RE system, this study is novel as it proposes a new methodology for determining the overall process energy and exergy efficiency of multigeneration systems. This novel method integrates EnergPLAN simulation program with EES and Matlab. It considers both the steady-state and the process performance of the modeled system on hourly timesteps in order to determine the overall efficiencies. Based on the proposed new method, it is observed that the overall process thermodynamic efficiencies of a hybrid renewable energy-based multigeneration system are different from its steady-state efficiencies. The overall energy and exergy efficiencies reduce from 81.01% and 52.52% (in steady-state condition) to 58.6% and 39.33% (when considering a one-year process performance). The integration of the hot water production with the multigeneration system enhanced the overall thermodynamic efficiencies in steady-state conditions. The Kalina system produces a total work output of 1171 kW with a thermal and exergy efficiency of 12.23% and 52% respectively while the wind turbine system produces 1297 kW of electricity in steady-state condition and it has the same thermal/exergy efficiency (72%). The economic analysis showed that the Levelized cost of electricity (LCOE) of the geothermal energy-based Kalina system is 0.0103 $/kWh. The greenhouse gas emission reduction analysis showed that the proposed system will save between 1,411,480 kg/yr and 3,518,760 kg/yr of greenhouse gases from being emitted into the atmosphere yearly. The multigeneration system designed in this study will produce electricity, hydrogen, hot water, cooling effect, and freshwater. Also, battery electric vehicle charging is integrated with process performance analysis of the multigeneration system.  相似文献   

6.
The process of charging of an encapsulated ice thermal energy storage device (ITES) is thermally modeled here through heat transfer and thermodynamic analyses. In heat transfer analysis, two different temperature profile cases, with negligible radial and/or stream-wise conduction are investigated for comparison, and the temperature profiles for each case are analyzed in an illustrative example. After obtaining temperature profiles through heat transfer analysis, a comprehensive thermodynamic study of the system is conducted. In this regard, energy, thermal exergy and flow exergy efficiencies, internal and external irreversibilities corresponding to flow exergy, as well as charging times are investigated. The energy efficiencies are found to be more than 99%, whereas the thermal exergy efficiencies are found to vary between 40% and 93% for viable charging times. The flow exergy efficiency varies between 48% and 88% for the flows and inlet temperatures selected. For a flow rate of 0.00164 m3/s, the maximum flow exergy efficiency occurs with an inlet temperature of 269.7 K, corresponding to an efficiency of 84.3%. For the case where the flow rate is 0.0033 m3/s, the maximum flow exergy efficiency becomes 87.9% at an inlet temperature of 270.7 K. The results confirm the fact that energy analyses, and even thermal exergy analyses, may lead to some unrealistic efficiency values. This could prove troublesome for designers wishing to optimize performance. For this reason, the flow exergy model provides the most useful information for those wishing to improve performance and reduce losses in such ITES systems.  相似文献   

7.
The proposed system targets the production of carbon dioxide-free hydrogen from liquefied natural gas through a solar-driven catalytic thermal cracking process integrated into the ammonia synthesis unit. The catalytic material is being regenerated in an adjacent vessel by burning the deposited coke. As a result, pure carbon dioxide stream is obtained and can be used directly in urea synthesis, sequestration or other related applications. It is expected that the system will reduce the amount of fossil fuel consumption in the ammonia synthesis and mitigate the associated environmental impacts. The energetic and exergetic analyses are carried out to assess the performance of the developed system and to identify the optimum operating conditions. At an operating temperature of 900 °C of thermocatalytic cracking, the optimum pressure for optimal production of hydrogen is determined to be 23.8 bar. The corresponding overall energy and exergy efficiencies are calculated as 35.8% and 37.4%, respectively. At the same conditions, the energy and exergy efficiencies of the thermal cracking unit reach 61.8% and 59.3%, respectively. Several parametric studies are conducted to evaluate the effects of operating conditions at the cracker, irradiance day-night ratio, and consideration of CO2 for transport and sequestration activities on the overall performance and production of the system. Ammonia production can reach 974 Metric Tons per Day (MTPD) and 893 MTPD considering operating conditions of 900 °C and 800 °C, and inlet LNG flow rate of 688 MTPD and 630 MTPD, respectively.  相似文献   

8.
High-temperature proton exchange membrane fuel cell (HT-PEMFC), which operates between 160 °C and 200 °C, is considered to be a promising technology, especially for cogeneration applications. In this study, a mathematical model of a natural gas fed integrated energy system based on HT-PEMFC is first developed using the principles of electrochemistry and thermodynamics (including energy and exergy analyses). The effects of some key operating parameters (e.g., steam-to-carbon ratio, HT-PEMFC operating temperature, and anode stoichiometric ratio) on the system performance (electrical, cogeneration, and exergetic efficiencies) are examined. The exergy destruction rates of each component in the integrated system are found for different values of these parameters. The results show that the most influential parameter which affects the performance of the integrated system is the anode stoichiometric ratio. For the baseline conditions, when the anode stoichiometric ratio increases from 1.2 to 2, the electrical, cogeneration, and exergetic efficiencies decrease by 42.04%, 33.15%, and 37.39%, respectively. The highest electrical power output of the system is obtained when the SCR, operating temperature, and anode stoichiometric ratio are taken as 2, 160 °C, and 1.2, respectively. For this case, the electrical, cogeneration, and exergetic efficiencies are found as 26.20%, 70.34%, and 26.74%, respectively.  相似文献   

9.
Electrochemical hydrogen compression (EHC) is a promising alternative to conventional compressors for hydrogen storage at high pressure, because it has a simple structure, low cost of hydrogen delivery, and high efficiency. In this study, the performance of an EHC is evaluated using a three-dimensional numerical model and finite volume method. The results of numerical analysis for a single cell of EHC are extended to a full stack of EHC. In addition, exergy and exergoeconomic analyses are carried out based on the numerical data. The effects of operating temperature, pressure, and gas diffusion layer (GDL) thickness on the energy and exergy efficiencies and the exergy cost of hydrogen are examined. The motivation of this study is to examine the performance of the EHC at different working conditions and also to determine the exergy cost of hydrogen. The results reveal that the energy and exergy efficiency of EHC stack improve by almost 3.1% when operating temperature increases from 363 K to 393 K and the exergy cost of hydrogen decreases by 0.5% at current density of 5000 A m−2. It is concluded that energy and exergy efficiency of EHC stack decrease by 25% and 5.4% when the cathode pressure increases from 1 bar to 30 bar, respectively. Moreover, it is realized that the GDL thickness has a considerable effect on the EHC performance. The exergy cost of hydrogen decreases by 53% when the GDL thickness decreases from 0.5 mm to 0.2 mm at current density of 5000 A m−2.  相似文献   

10.
In this study, a comprehensive performance analysis of a transportation system powered by a PEM fuel cell engine system is conducted thermodynamically both through energy and exergy approaches. This system includes system components such as a compressor, humidifiers, pressure regulator, cooling system and the fuel cell stack. The polarization curves are studied in the modeling and compared with the actual data taken from the literature works before proceeding to the performance modeling. The system performance is investigated through parametric studies on energy, exergy and work output values by changing operating temperature, operating pressure, membrane thickness, anode stoichiometry, cathode stoichiometry, humidity, reference temperature and reference pressure. The results show that the exergy efficiency increases with increase of temperature from 323 to 353 K by about 8%, pressure from 2.5 to 4 atm by about 5%, humidity from 97% to 80% by about 10%, and reference state temperature from 253 to 323 K by about 3%, respectively. In addition, the exergy efficiency increases with decrease of membrane thickness from 0.02 to 0.005 mm by about 9%, anode stoichiometry from 3 to 1.1 by about 1%, and cathode stoichiometry from 3 to 1.1 by about 35% respectively.  相似文献   

11.
A pressurized gasification combined system is studied in a novel integration with geothermal energy to produce hydrogen-enriched syngas. This system utilizes dewatered sludge, which leaves the biological wastewater treatment facility during the wastewater treatment process and is used as a feedstock to produce hydrogen as a useful output. The hydrogen produced is transformed in a proton-exchange fuel cell to electricity for community use. This system also incorporates a wind farm with a hydrogen storage system to meet societies’ energy need when the energy demand fluctuates. The integrated system is then analyzed with thermodynamic-based energy and exergy approaches. The Greater Toronto area is chosen as the case study location and comprehensive thermodynamic analysis and simulation are completed on the Aspen Plus and Engineering Equation Solver softwares while the annual wind speed data are obtained from the RETScreen software. The daily total energy delivered to the community from this proposed system is recorded to be 2.1 GWh. In addition, the hydrogen production ratio at the gasification system is observed to be 0.12 through the sludge utilization where the energy and exergy efficiencies of the integrated gasification combined cycle were calculated to be 24% and 28%, in this order. The highest energy and exergy efficiency with 38.6% and 42.2%, respectively, are observed in January where the wind farm operated at a capacity of 41.7% and the average wind speed was 6.3 m/s for Greater Toronto Area. The overall energy and exergy efficiencies of this waste-to-energy system are calculated as 32.7% and 36.6%, respectively.  相似文献   

12.
In this paper, a detailed review is presented to discuss biomass‐based hydrogen production systems and their applications. Some optimum hydrogen production and operating conditions are studied through a comprehensive sensitivity analysis on the hydrogen yield from steam biomass gasification. In addition, a hybrid system, which combines a biomass‐based hydrogen production system and a solid oxide fuel cell unit is considered for performance assessment. A comparative thermodynamic study also is undertaken to investigate various operational aspects through energy and exergy efficiencies. The results of this study show that there are various key parameters affecting the hydrogen production process and system performance. They also indicate that it is possible to increase the hydrogen yield from 70 to 107 g H2 per kg of sawdust wood. By studying the energy and exergy efficiencies, the performance assessment shows the potential to produce hydrogen from steam biomass gasification. The study further reveals a strong potential of this system as it utilizes steam biomass gasification for hydrogen production. To evaluate the system performance, the efficiencies are calculated at particular pressures, temperatures, current densities, and fuel utilization factors. It is found that there is a strong potential in the gasification temperature range 1023–1423 K to increase energy efficiency with a hydrogen yield from 45 to 55% and the exergy efficiency with hydrogen yield from 22 to 32%, respectively, whereas the exergy efficiency of electricity production decreases from 56 to 49.4%. Hydrogen production by steam sawdust gasification appears to be an ultimate option for hydrogen production based on the parametric studies and performance assessments that were carried out through energy and exergy efficiencies. Finally, the system integration is an attractive option for better performance. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
The energy and exergy flow for a space heating systems of a typical residential building of natural ventilation system with different heat generation plants have been modeled and compared. The aim of this comparison is to demonstrate which system leads to an efficient conversion and supply of energy/exergy within a building system.The analysis of a fossil plant heating system has been done with a typical building simulation software IDA–ICE. A zone model of a building with natural ventilation is considered and heat is being supplied by condensing boiler. The same zone model is applied for other cases of building heating systems where power generation plants are considered as ground and air source heat pumps at different operating conditions. Since there is no inbuilt simulation model for heat pumps in IDA–ICE, different COP curves of the earlier studies of heat pumps are taken into account for the evaluation of the heat pump input and output energy.The outcome of the energy and exergy flow analysis revealed that the ground source heat pump heating system is better than air source heat pump or conventional heating system. The realistic and efficient system in this study “ground source heat pump with condenser inlet temperature 30 °C and varying evaporator inlet temperature” has roughly 25% less demand of absolute primary energy and exergy whereas about 50% high overall primary coefficient of performance and overall primary exergy efficiency than base case (conventional system). The consequence of low absolute energy and exergy demands and high efficiencies lead to a sustainable building heating system.  相似文献   

14.
A transient thermodynamic analysis is reported of a novel chemical hydrogen storage system using energy and exergy approaches. The hydrogen is stored chemically in ammonia using the proposed hydrogen storage system and recovered via the electrochemical decomposition of ammonia through an ammonia electrolyzer. The proposed hydrogen storage system is based on a novel subzero ammonia production reactor. A single stage refrigeration system maintains the ammonia production reactor at a temperature of −10 °C. The energy and exergy efficiencies of the proposed system are 85.6% and 85.3% respectively. The proposed system consumes 34.0 kJ of work through the process of storing 1 mol of hydrogen and recovering it using the ammonia electrolyzer. The system is simulated for filling 30,000 L of ammonia at a pressure of 5 bar, and the system was able to store 7500 kg of ammonia in a liquid state (1% vapor) in 1500 s. The system consumes nearly 45.3 GJ of energy to store the 7500 kg of ammonia and to decompose it to reproduce the stored hydrogen during the discharge phase.  相似文献   

15.
This paper reports on an energy/exergy analysis of a standalone solar-hydrogen system with a metal hydride (MH) system thermally managed using a phase change material (PCM). This is a self-contained thermal management arrangement that stores the heat released from the MH unit, when it is being charged and transfers it back to the MH while discharging hydrogen. The first and second laws of thermodynamics were used to develop a mathematical model in MATLAB to simulate this system and quality its performance from the energy and exergy viewpoints. The model was then applied on a passive standalone house, with ~3.8 MWh/year electricity demand, located in southeast Australia. The exergy efficiencies of the solar PV, electrolyser, fuel cell and the whole solar hydrogen system were found to be 6.5%, 88%, 50.6%, and 3.74%, respectively. The paper also provides the detailed entropy generation and exergy analysis on the MH hydrogen storage unit together with its PCM-based thermal management arrangement. The results show that the annual entropy generation, exergy destruction and exergy efficiency of the MH hydrogen storage unit were 173 Wh/K, 51.5 kWh, and 98.8%, respectively.  相似文献   

16.
An improved very high temperature gas-cooled reactor (VHTR) and copper-chlorine (Cu–Cl) cycle-based nuclear hydrogen production system is proposed and investigated in this paper, in order to reveal the unknown thermo-economic characteristics of the system under variable operating conditions. Energy, exergy and economic analysis method and particle swarm optimization algorithm are used to model and optimize the system, respectively. Parametric analysis of the effects of several key operating parameters on the system performance is conducted, and energy loss, exergy loss, and investment cost distributions of the system are discussed under three typical production modes. Results show that increasing the reactor subsystem pressure ratio can enhance the system's thermo-economic performance, and the total efficiencies and cost of producing compressed hydrogen from nuclear energy are respectively lower and higher than that of generating electricity. When the system operates at the maximum hydrogen production rate of 403.1 mol/s, the system's net electrical power output, thermal efficiency, exergy efficiency, and specific energy cost are found to be 38.77 MW, 39.3%, 41.26%, and 0.0731 $/kW·h, respectively. And when the system's hydrogen production load equals to 0, these values are respectively calculated to be 177.25 MW, 50.64%, 53.29%, and 0.0268 $/kW·h. In addition, more than 90% of the system's total energy losses are caused by condenser and Cu–Cl cycle, and about 50–60% of the system's total exergy destructions occur in VHTR. About 60% and 30% of the system's specific energy cost are respectively caused by the equipment investment and the system operation & maintenance, and the investment costs of VHTR and Cu–Cl plant are the system's main capital investment sources.  相似文献   

17.
In this paper we study an integrated PV/T absorption system for cooling and hydrogen production based on U.A.E weather data. Effect of average solar radiation for different months, operating time of the electrolyzer, air inlet temperature and area of the PV module on power and rate of heat production, energy and exergy efficiencies, hydrogen production and energetic and exergetic COPs are studied. It is found that the overall energy and exergy efficiency varies greatly from month to month because of the variation of solar radiation and the time for which it is available. The highest energy and exergy efficiencies are obtained for the month of March and their value is 15.6% and 7.9%, respectively. However, the hydrogen production is maximum for the month of August and its value is 9.7 kg because in august, the solar radiation is high and is available for almost 13 h daily. The maximum energetic and exergetic COPs are calculated to be 2.28 and 2.145, respectively and they are obtained in the month of June when solar radiation is high for the specified cooling load of 15 kW.  相似文献   

18.
A simple thermodynamic model of SOEC system was presented in this paper. We performed energy and exergy analysis on the SOEC system to determine its optimal operating conditions. Parametric studies have been carried out to determine the effects of key operating parameters on the SOEC system. For given operating conditions and set assumptions, it was found that the optimal voltage applied to the SOEC system is 1.37 V. At this optimal value, the SOEC system is capable of achieving 50% and 60%, respectively, in terms of energy and exergy efficiency. It also achieved 67% reduction in CO2 with maximum feedstock conversion of 63.5%. The corresponding energy and exergy required to convert one kg of CO2 is 16.4 kJ and 7.2 kJ, respectively.  相似文献   

19.
This paper presents the analysis of sectoral energy and exergy utilization of Saudi Arabia by considering the energy and exergy flows for the 12 years between 1990 and 2001. Sectoral energy and exergy efficiencies are obtained for the subsectors and the devices used in each sector. Energy and exergy flow diagrams for Saudi Arabia are also presented, respectively, to illustrate the situation on how energy and exergy efficiencies vary in each sector. The residential sector appears to be the most energy efficient sector, and the industrial sector to be the most exergy efficient. It is believed that the current methodology is useful for analyzing sectoral energy and exergy utilization, which will help Saudi Arabia with energy savings through energy efficiency and/or energy conservation measures. It is also be helpful to establish standards to facilitate application in various sectors and processes for a sustainable energy planning. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

20.
Hydrogen is an essential component of power-to-gas technologies that are needed for a complete transition to renewable energy systems. Although hydrogen has zero GHG emissions at the end-use point, its production could become an issue if non-renewable, and pollutant energy and material resources are used in this step. Therefore, a crucial step for the fully developed hydrogen economy is to find alternative hydrogen production methods that are clean, efficient, affordable, and reliable. With this motivation, in this study, an integrated and continuous type of hydrogen production system is designed, developed, and investigated. This system has three components. There is a solar spectral splitting device (Unit I), which splits the incoming solar energy into two parts. Photons with longer wavelength is sent to the photovoltaic thermal hybrid solar collector, PV/T, (Unit II) and used for combined heat and power generation. Then the remaining part is transferred to the novel hybrid photoelectrochemical-chloralkali reactor (Unit III) for simultaneous H2, Cl2, and NaOH production. This system has only one energy input, which is the solar irradiation and five outputs, namely H2, Cl2, NaOH, heat, and electricity. Unlike most of the studies in the literature, this system does not use only PV or only a photoelectrochemical reactor. With this approach, solar energy utilization is maximized, and the wasted portion is minimized. By selecting PV/T rather than PV, the performance of the panels is maximized because recovering the by-product heat as a system output in addition to electricity, and the PV/T has less waste and higher efficiency. The present reactor does not use any additional electron donors, so the wastewater discharge is only depleted NaCl solution, which makes the system significantly cleaner than the ones available in the literature. The specific aim of this study is to demonstrate the optimum operating parameters to reach the maximum achievable production rates and efficiencies while keeping the exergy destruction as little as possible. In this study, there are four case studies, and in each case study, one decision variable is optimized to get the desired performance results. Within the selected operating parameter range, all performance criteria (except exergy destruction) are normalized and ranked for proper comparison. The maximum production rates and efficiencies with the least possible exergy destruction are observed at the operating temperature of 30 °C. At 30 °C, 4.18 g/h H2, 127.55 g/h Cl2, 151 W electricity, and 716 W heat are produced with an exergy destruction rate of 95.74 W and 78% and 30% energy and exergy efficiencies, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号