首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
Energy aspects vs. hygiene aspects of thermal insulation. Are current design criteria for thermal insulation in winter suitable for assessing mould risk in older and new buildings? Determining minimum surface temperatures in affected areas with the aid of thermal bridge calculations is an important basis for analysing mould growth. According to the generally recognised state of the art, calculations are usually based on steady‐state conditions and design data for minimum thermal insulation requirements in winter. This article initially explains the origins of these boundary conditions in the field of thermal insulation and current options and requirements for assessing calculation results. The article then illustrates that, contrary to the conventional view, the “cold, dry” boundary conditions currently used do not necessarily represent the worst case of external climate conditions that can be expected. The authors suggest that the boundary conditions for the calculations should be amended, so that less favourable “mild, damp” external conditions during spring and autumn can be taken into account. Suitable approaches are proposed.  相似文献   

6.
What was the maximum Temperature of the prestressing Steel of the Bridge over the BAB 2 during the Fire at July 16, 2004? At July 16, 2004 a bridge over the BAB 2 was damaged by fire. The practicability to repair the brigde was mainly determined by the maximum temperature of the prestressing steels during the fire. By computer simulations and chemical analysis it could be determined, that the prestressing steel has not reached a temperature of 200 °C. Plastic deformations and a permanent loss of strength could therefore be excluded with great certainty. The bridge can be repaired with relative low expense.  相似文献   

7.
8.
Christoph Geyer 《Bauphysik》2004,26(4):172-183
Examination of the thermal insulation characteristics of external corners above unheated basements in dwellings – the Achilles' heel of heavy‐weight external walls with thermal insulation on the outside? External walls in dwellings consist often of a heavy‐weight wall and a thermal insulation fixed outside. With this construction the insulation of the external wall is separated by the plinth of the external wall from the thermal insulation incorporated in the slab above an unheated basement. This results in a thermal bridge along the edge of the basement slab. The most critical point of the construction with regard to thermal protection occurs at the exterior corner at ground floor level, where two linear thermal bridges overlay. For this reason the minimum inner surface temperature of the corner is used to estimate the heat protection of the construction. A number of calculations of the minimum temperature at the interior surface of this three dimensional thermal bridge is performed to evaluate the parameters of the adjacent construction details which affect the minimum temperature at the inner surface of the corner. To reach the minimum temperature at he inner surface of the corner of 12.6 °C demanded by the German standard DIN 4108‐2 as the minimum requirement of heat protection for thermal bridges, thermal resistances of the whole wall construction much higher than 1.2 m2K/W are necessary. For this construction type of exterior walls a thermal resistance of 1.2 m2K/W as demanded in table 3 of the German standard DIN 4108‐2 as a minimum heat insulation for exterior walls can be shown to be insufficient to assure a minimum temperature of 12.6 °C at the inner surface of the corner at ground floor level. Thus it is proposed to add additional notes concerning this construction type in this standard.  相似文献   

9.
10.
11.
12.
Bezüglich der Beibehaltung der Parteistellung kommt es nicht auf ein "Einverst?ndnis" des Nachbarn mit einem Bauvorhaben an, sondern ausschlie?lich auf die Geltendmachung von subjektiv-?ffentlichen Rechten. Die blo?e Aufforderung des Grundeigentümers, sich vertraglich (hier: zu L?rmschutzma?nahmen sowie einem bestimmten Dienstbarkeitsvertrag) gegenüber dem Nachbarn zu verpflichten, stellt keine Einwendung dar.  相似文献   

13.
14.
ThermoShield – a contribution to thermal insulation? For some time now, so called thermal coatings are being introduced onto the market. Advertisement to these products announce that these coatings reduce heating energy requirement in buildings considerably. These coatings are facade paintings, e.g the product “ThermoShield”, to which microscopic small ceramic bubbles are added. In the product data to these coatings, a heating energy saving up to 30% are mentioned. The manufacturer impute these saving to different effects of the “ThermoShield” coating. To check the upper mentioned promising product properties, the thermal behaviour of test specimens coated with “ThermoShield – Exterieur” are being studied within the scope of a research work at the University of Hannover. The evaluation of the measurement results showed, that the specimens coated with “ThermoShield” did not have the thermal properties expected and that this coating do not show any of the promised thermal insulating properties.  相似文献   

15.
16.
Handelt es sich bei Abweichungen von der Baubewilligung bereits um einen bewilligungspflichtigen "Umbau" (iSd krnt BauO), k?nnen diese ?nderungen nicht im Zuge einer Planwechselbewilligung genehmigt werden.  相似文献   

17.
Von einer Abweichung von den Vertragsbestimmungen der ?NORM B 2110 "in einzelnen Punkten" kann nicht gesprochen werden, wenn die Bestimmungen der ?NORM B 2110 überhaupt nur vereinzelt "in Randbereichen" gelten sollen.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号