首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到14条相似文献,搜索用时 93 毫秒
1.
Kenics混合器混合性能的模拟研究   总被引:2,自引:0,他引:2  
王丽  张沛  姬宜朋 《塑料》2006,35(3):87-93
利用Fluent有限元分析软件计算了流体流过Kenics混合器过程中的应变速率,进而分析混合元件转速与旋转式Kenics混合器混合效率的关系,以及混合元件与机筒间隙对静态和旋转式Kenics混合器对混合效率的影响。模拟分析结果表明:旋转式Kenics混合器混合效率随转速增加而提高;减小混合元件与机筒间间隙有利于增加静态Kenics混合器混合效率,但间隙的减小对旋转式Kenics混合器混合效率的影响却很小。  相似文献   

2.
张晓露  陈伟  王小芳 《化工机械》2007,34(3):144-147
采用计算流体动力学(CFD)的方法,分别计算了Kenics型静态混合器和GK型静态混合器内的流场。数值模拟的结果表明,Kenics型静态混合器内流场的湍动强度大于GK型静态混合器的,导致了Kenics型静态混合器的流体阻力和传热系数大于GK型静态混合器的。GK型静态混合器的压力降大约只是Kenics型静态混合器压力降的0.554~0.579倍,但两者的传热膜系数相差不大。GK型静态混合器具有较强的综合性能。  相似文献   

3.
采用CFD-PBM耦合方法对Kenics型静态混合器内分散相油滴破碎及聚并行为进行数值模拟研究,分析了雷诺数、混合元件数、元件长径比等参数对分散相液滴粒径的影响,揭示了分散相在Kenics静态混合器内流动过程中液滴粒径的演化规律.结果表明,随雷诺数增大,分散相液滴出口粒径不断减小,并出现临界趋势;静态混合器的前几个元件...  相似文献   

4.
通过对管内插入Kenics静态混合器的水平液固循环流化床换热器进行数值模拟和实验研究,考察了静态混合器扭率对颗粒分布、传热性能和流阻性能的影响。结果表明:水平管内安装Kenics静态混合器的扭率越小,管内颗粒分布均匀距离越长。当雷诺数在10 000—45 000之间,扭率为1.5,2.5,4,6的Kenics静态混合器的综合性能评价指标PEC均大于1,说明了水平流化床换热器插入Kenics静态混合器能够改善传热。当流速大于1.5 m/s,在2 m长的水平流化床换热器内安装一个扭率为1.5的Kenics静态混合器能够达到改善颗粒分布和提高传热性能的效果。  相似文献   

5.
陈再良  王传洋 《塑料工业》2004,32(11):31-32,42
以聚丙烯/蒙脱土纳米复合材料(PP/MMT)为原料,在单螺杆挤出装置上,通过连接Kenics静态混合器,研究了静态混合器对PP/MMT微观形态的影响,并用透射电子显微镜(TEM)研究了MMT在PP中分散的形态。结果表明:通过Kenics静态混合器混合后,MMT在基体PP中的分散更加均匀,并出现明显的片层剥离;混沌混合是获取剥离型PP/MMT的有效手段。  相似文献   

6.
利用专用CFD软件Polyflow对SMX型和Kenics型静态混合器中PS/CO_2发泡溶液进行数值模拟计算,分析比较不同板厚在不同元件个数条件下两种静态混合器消耗的压力损失,以及不同CO_2浓度对静态混合器压力损失的影响;并引入"离散系数"分析比较两种静态混合器出口温度均匀性的变化.数值模拟的结果表明:SMX型静态混合器冷却效果优于Kenics型静态混合器,并且SMX型静态混合器出口温度均匀性高于Kenics型静态混合器.  相似文献   

7.
本文提出了在各种类型的静态混合器中连续混合过程的放大通用关系式;利用这些关系式能精确计算混合器所需要的混合元件数和测定流体流量,并且应用常规方程对Kenics型、Sulzer型和RossISG型混合器进行了放大描述和比较。  相似文献   

8.
刘燕  张英迪  裴程林  王智  张伟 《化工进展》2016,35(11):3421-3425
对管内插入Kenics静态混合器的水平液固循环流化床换热器进行实验研究,实验考察了静态混合器扭率、静态混合器安装方式、液体流速、颗粒体积分数对传热性能和流阻性能的影响,并运用综合强化传热性能评价指标(PEC)对其进行分析。实验发现,传热性能和阻力系数均随扭率增加而减小。当雷诺数在10000~45000之间时,扭率为1.5、2、2.5、3.5的Kenics静态混合器的PEC指标均大于1,说明了水平流化床换热器插入Kenics静态混合器能够改善传热。在雷诺数达到25000左右、Kenics静态混合器扭率为2.5、颗粒体积分数为4%时,水平流化床换热器的PEC指标最高达到1.18。当两个扭率均为2.5的Kenics静态混合器安装间距为200mm时,水平流化床换热器的PEC指标最高。  相似文献   

9.
为了解决水平液固循环流化床中颗粒分布不均匀问题,在内径29 mm、长4 m的水平有机玻璃管流化床内放入Kenics静态混合器,采用CCD图像测量与数据处理系统考察静态混合器的结构、个数、安装位置对液固二相流中颗粒分布的影响;同时,利用U型管压差计考察不同条件下静态混合器的压降。实验结果表明:Kenics静态混合器能明显地改善管内颗粒分布情况;单个扭率Y=3.5的Kenics静态混合器压降最小;2个扭率Y=3.5的Kenics静态混合器间距为40 mm时对颗粒分布影响长度是最长的。  相似文献   

10.
Kenics静态混合器的流体力学性能   总被引:2,自引:1,他引:2  
用激光测速仪(LDV)测定了φ50mm Kenics静态混合器的流场、压力降和液滴平均直径。着重讨论了流量和混合单元数对轴向速度、切向速度和湍流强度的影响,并对静态混合器内液滴粉碎的机理进行了探讨。研究结果对消化吸收引进技术和合理地设计大型静态混合器具有参考价值。  相似文献   

11.
Performance of Kenics static mixer over a wide range of Reynolds number   总被引:1,自引:0,他引:1  
The present study deals with the numerical simulation of flow patterns and mixing behaviour in Kenics static mixer over a wide range of Reynolds number. Three different sets of Kenics mixer (aspect ratio = 1.5) comprised of 3, 9 and 25 elements each have been characterized. The Reynolds number was varied in the range of 1 to 25,000 (i.e., from laminar to turbulent flow regime). The numerical approach takes into account the aspects of the fluid flow at higher Reynolds number values including circumferential velocity profiles at different cross-sections within the Kenics mixer, which were neglected in previous studies. It was observed that cross-sectional mixing in the turbulent flow regime takes place up to 30% of each element length at element-to-element transition; beyond that velocity profiles were uniform. The experiments were also carried out to measure the circumferential and axial velocity profiles and pressure drop in three different Kenics Mixers using air as fluid. The pressure drop per unit element (ΔP/η) was found to be independent of the number of Kenics mixing elements used in the system. The total pressure drop across Kenics mixer obtained by CFD simulations were compared with the experimental pressure drop values and correlations available in the literature. The numerical results were found in good agreement with the experimental as well as the results reported in the literature. A new pressure drop correlation in the Kenics static mixer has been developed.  相似文献   

12.
以饱和硫酸钙为介质,在安装Kenics静态混合器的水平液固两相流化床换热管上进行实验研究,考察介质流速、Kenics静态混合器扭率、颗粒体积分数及颗粒尺寸对压降的影响,并与冷态实验条件下的压降变化规律进行比较。结果表明:同等操作条件,安装Kenics静态混合器后压降比安装前提高20%~140%;压降随雷诺数的增大而增大,随Kenics静态混合器扭率的增大而减小;颗粒体积分数对压降也有影响。根据实验数据,得出了稳定操作条件下压降与上述影响因素之间的经验关联式,为带有Kenics静态混合器的水平液固两相流化床换热器的设计提供计算依据。  相似文献   

13.
Temperature-sensitive hydrogel beads were prepared by Kenics static mixer technology. The temperature-sensitive monomer N,N-diethylacrylamide and photo-crosslinkable pre-polymer ENT were used as model hydrogel materials. Drop dispersion of high viscosity polymer material in low viscosity hexadecane was made using the static mixer. Drops of a solution of the mixed materials were rapidly photo-crosslinked by UV irradiation after mixing in the static mixer, and spherical hydrogel beads with narrow, normal size distribution were thus prepared. The Kenics static mixer is a useful device for the preparation of spherical beads of temperature-sensitive hydrogels. The Sauter Mean Diameter of the hydrogel beads swollen in deionized water at 293 K was measured. The experimentally determined dimensionless swollen hydrogel bead diameter was well correlated with the Weber number, degree of swelling and viscosity ratio. The effects of gelation and ENT addition on the bead size were evaluated from the degree of swelling. The correlation equation can be used for size adjustment of temperature-sensitive spherical hydrogel beads.  相似文献   

14.
混合元件数对SK型静态混合器流场特性的影响   总被引:4,自引:2,他引:2       下载免费PDF全文
龚斌  包忠平  张春梅  吴剑华 《化工学报》2009,60(8):1974-1980
以SK型静态混合器为对象,运用激光多普勒测速仪对混合器内流场进行测量分析,研究混合元件数对混合器内速度分布和湍动性能影响。结果表明:在扭旋叶片作用下,流体在混合器内的速度会重新分布,湍动会被强化,这一过程主要在前3个混合元件中实现,且湍动逐渐增加,但增加速度逐渐减弱,第1个混合元件强化作用最为显著,进入第4个混合元件后基本达到稳定;当混合叶片数量超过3个以后,对流体湍动的强化基本达到混合器强化能力的极限,继续增加元件数量不能提高流体的湍动程度,但可以维持这种湍动。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏