首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The future success of fuel cell electric vehicles requires a corresponding infrastructure. In this study, two different refueling station concepts for fuel cell passenger cars with 70 MPa technology were evaluated energetically. In the first option, the input of the refueling station is gaseous hydrogen which is compressed to final pressure, remaining in gaseous state. In the second option, the input is liquid hydrogen which is cryo-compressed directly from the liquid phase to the target pressure. In the first case, the target temperature of −33 °C to −40 °C [1] is achieved by cooling down. In the second option, gaseous deep-cold hydrogen coming from the pump is heated up to target temperature. A dynamic simulation model considering real gas behavior to evaluate both types of fueling stations from an energetic perspective was created. The dynamic model allows the simulation of boil-off losses (liquid stations) and standby energy losses caused by the precooling system (gaseous station) dependent on fueling profiles. The functionality of the model was demonstrated with a sequence of three refueling processes within a short time period (high station utilization). The liquid station consumed 0.37 kWh/kg compared to 2.43 kWh/kg of the gaseous station. Rough estimations indicated that the energy consumption of the entire pathway is higher for liquid hydrogen. The analysis showed the high influence of the high-pressure storage system design on the energy consumption of the station. For future research work the refueling station model can be applied to analyze the energy consumption dependent on factors like utilization, component sizing and ambient temperature.  相似文献   

2.
Development of efficient hydrogen refueling station (HRS) is highly desirable to reduce the hydrogen cost and hence the life cycle expense of fuel cell vehicles (FCVs), which is hindering the large scale application of hydrogen mobility. In this work, we demonstrate the optimization of gaseous HRS process and control method to perform fast and efficient refueling, with reduced energy consumption and increased daily fueling capacity. The HRS was modeled with thermodynamics using a numerical integration method and the accuracy for hydrogen refueling simulation was confirmed by experimental data, showing only 2 °C of temperature rise deviation. The refueling protocols for heavy duty FCVs were first optimized, demonstrating an average fueling rate of 2 kg/min and pre-cooling demand of less than 7 kW for 35 MPa type III tanks. Fast refueling of type IV tanks results in more significant temperature rise, and the required pre-cooling temperature is lowered by 20 K to achieve comparable fueling rate. The station process was also optimized to improve the daily fueling capacity. It is revealed that the hydrogen storage amount is cost-effective to be 25–30% that of the nominal daily refueling capacity, to enhance the refueling performance at peak time and minimize the start and stop cycles of compressor. A novel control method for cascade replenishment was developed by switching among the three banks in the order of decreased pressure, and results show that the daily refueling capacity of HRS is increased by 5%. Therefore, the refueling and station process optimization is effective to promote the efficiency of gaseous HRS.  相似文献   

3.
One of the main obstacles of the diffusion of fuel cell electric vehicles (FCEV) is the refueling system. The new stations follow the refueling protocol from the Society of Automotive Engineers where the way to reach the target pressure is not explained. This work analyzes the thermodynamics of a hydrogen fueling station in order to study the effects of the cascade storage system topology on the energy consumption for the cooling facility. It is found that the energy consumption for cooling increases, expanding the total volume of the cascade storage system. Comparing the optimal and the worst volume configurations of the cascade storage tanks at different ambient temperatures, the energy saving is approximately 12% when the average ambient temperature is 20 °C and around 20% when the average ambient temperature is 30 °C. The energy consumption for cooling is significantly influenced by the topology of the cascade storage system and it is particularly relevant in the case of low daily-dispensed amount of hydrogen.  相似文献   

4.
In this study, different hydrogen refueling station (HRS) architectures are analyzed energetically as well as economically for 2015 and 2050. For the energetic evaluation, the model published in Bauer et al. [1] is used and norm-fitting fuelings according to SAE J2601 [2] are applied. This model is extended to include an economic evaluation. The compressor (gaseous hydrogen) resp. pump (liquid hydrogen) throughput and maximum pressures and volumes of the cascaded high-pressure storage system vessels are dimensioned in a way to minimize lifecycle costs, including depreciation, capital commitment and electricity costs. Various station capacity sizes are derived and energy consumption is calculated for different ambient temperatures and different station utilizations. Investment costs and costs per fueling mass are calculated based on different station utilizations and an ambient temperature of +12 °C. In case of gaseous trucked-in hydrogen, a comparison between 5 MPa and 20 MPa low-pressure storage is conducted. For all station configurations and sizes, a medium-voltage grid connection is applied if the power load exceeds a certain limit. For stations with on-site production, the electric power load of the hydrogen production device (electrolyzer or gas reformer) is taken into account in terms of power load. Costs and energy consumption attributed to the production device are not considered in this study due to comparability to other station concepts. Therefore, grid connection costs are allocated to the fueling station part excluding the production device. The operational strategy of the production device is also considered as energy consumption of the subsequent compressor or pump and the required low-pressure storage are affected by it. All station concepts, liquid truck-supplied hydrogen as well as stations with gaseous truck-supplied or on-site produced hydrogen show a considerable cost reduction potential. Long-term specific hydrogen costs of large stations (6 dispensers) are 0.63 €/kg – 0.76 €/kg (dependent on configuration) for stations with gaseous stored hydrogen and 0.18 €/kg for stations with liquid stored hydrogen. The study focuses only on the refueling station and does not allow a statement about the overall cost-effectiveness of different pathways.  相似文献   

5.
The capacity of hydrogen storage by solar adsorption in activated carbon AX-21 and filling rate with simultaneous production have been conditioned under a minimum pressure, to nullify the cost of energy supplied to compressor. A gas accumulator tank connected to electrolyzer and continuous adsorption beds have been proposed in the process scheme. Minimum pressure required for the tank at an ambient filling temperature fixed to 25 °C is only 2 bar. While at atmospheric filling pressure the corresponding value of filling temperature is found to be 5 °C. However, a cooling fluid at low temperature for adsorbent bed during the adsorption process will be an efficient way for increasing the stored amount of hydrogen. Almost 4.5 kg of hydrogen can be stored in an adsorbent mass of 200 kg. The adsorption flow rate has been also modelled to be controlled for being adapted to production rate.  相似文献   

6.
TC21 alloy is hydrogenated under different initial hydrogen pressures at hydrogenation temperatures in the range of 450 °C–850 °C. Hydrogen absorption characteristic and kinetics during the heat preservation stage and cooling stage, hydrogen content and activation energy are investigated. The hydrogen absorption reaches equilibrium first at higher hydrogenation temperature and initial hydrogen pressure during the heat preservation stage. The hydrogen absorption reaches equilibrium first at lower hydrogenation temperature and initial hydrogen pressure during the cooling stage. Mechanisms of hydrogen absorption are analyzed during the heat preservation stage and the cooling stage. Phase compositions of the hydrogenated TC21 alloys are analyzed by XRD. Hydrogen content increases first and then decreases, then increases slightly, and finally decreases with the increase of hydrogenation temperature. Hydrogen content increases gradually with the increase of initial hydrogen pressure. The activation energy of hydrogen absorption in TC21 alloy is about 18.304 kJ/mol.  相似文献   

7.
A housing insulation of hydrogen refuelling station is vital from the aspect of safe operation of equipment in an environment that is installed. To secure hydrogen supply during the whole year, this work brings the solution for both cooling and heating insulation equipment inside of hydrogen refuelling station installed in Croatia, Europe. This hydrogen refuelling station was designed as an autonomous photovoltaic-hydrogen system. In the interest of improving its energy efficiency, an optimal thermal management strategy was proposed. To select the best technological solution for thermal management design which will maintain optimal temperature range inside the housing in cold and warm months, a detailed analysis of the system components thermodynamic parameters was performed. Optimal operating temperatures were established to be 25 °C in summer and 16 °C in winter, considering components working specifications. Insulation, type of cooling units, and heaters have been selected according to the HRN EN 12831 and VDI 2078 standards, while the regime of the heating and cooling system has been selected based on the station's indoor air temperature. The annual required heating and cooling energy were calculated according to HRN EN ISO 13790 standard, amounting to 1135.55 kW h and 1219.55 kW h, respectively. Annual energy share obtained from solar power plant used for the heating and cooling system resulted in 5%. The calculated thermal management system load turned out to be 1.437 kW.  相似文献   

8.
A novel silica gel–water adsorption chiller (driven by hot water of 60–90 °C) with three vacuum chambers has been built in Shanghai Jiao Tong University (SJTU). This chiller was an improvement of an earlier deigned chiller and it integrated two single-bed systems (basic system) with only one vacuum valve. The performance of the chiller was tested and compared with the former adsorption chiller. The results show that the cooling power and COP of the chiller are 8.70 kW and 0.39 for the heat source temperature of 82.5 °C, cooling water temperature of 30.4 °C and chilled water outlet temperature of 12 °C. For a higher chilled water outlet temperature of about 16 °C, the COP increases to 0.43 while the cooling power is about 11.0 kW. Compared with that of the former chiller, the COP of this chiller increases by 20%.  相似文献   

9.
The application of hydrogen energy urgently requires a high-capacity hydrogen storage technology that can release hydrogen at low temperature. The composite of LiAlH4 and NH4F has a hydrogen storage capacity of up to 8.06 wt%, but the release of hydrogen requires a reaction temperature of about 170 °C, and the reaction is difficult to control. In this work, the reaction between LiAlH4 and NH4F is proposed to be carried out in diethyl ether to improve its hydrogen release performance. It exhibits good hydrogen release performance over a wide temperature range of −40–25 °C, and the hydrogen release capacity at −40 °C, −20 °C, 0 °C and 25 °C can reach 4.41 wt%, 6.79 wt%, 6.85 wt% and 7.78 wt%, respectively. The activation energy of the reaction is 38.41 kJ mol−1, which is much lower than many previously reported catalytic hydrolysis systems that can release hydrogen at room temperature. Our study demonstrates a high-performance hydrogen storage system with very low operating temperature, which may lay the foundation for the development of practical mobile/portable hydrogen source in the north and the Arctic.  相似文献   

10.
The prototype of combined vapour compression–absorption refrigeration system was set up, where a gas engine drove directly an open screw compressor in a vapour compression refrigeration chiller and waste heat from the gas engine was used to operate absorption refrigeration cycle. The experimental procedure and results showed that the combined refrigeration system was feasible. The cooling capacity of the prototype reached about 589 kW at the Chinese rated conditions of air conditioning (the inlet and outlet temperatures of chilled water are 12 and 7°C, the inlet and outlet temperatures of cooling water are 30 and 35°C, respectively). Primary energy rate (PER) and comparative primary energy saving were used to evaluate energy utilization efficiency of the combined refrigeration system. The calculated results showed that the PER of the prototype was about 1.81 and the prototype saved more than 25% of primary energy compared to a conventional electrically driven vapour compression refrigeration unit. Error analysis showed that the total error of the combined cooling system measurement was about 4.2% in this work. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
Reliable hydrogen fueling stations will be required for the successful commercialization of fuel cell vehicles. An evolving hydrogen fueling station has been in operation in Irvine, California since 2003, with nearly five years of operation in its current form. The usage of the station has increased from just 1000 kg dispensed in 2007 to over 8000 kg dispensed in 2011 due to greater numbers of fuel cell vehicles in the area. The station regularly operates beyond its design capacity of 25 kg/day and enables fuel cell vehicles to exceed future carbon reduction goals today. Current limitations include a cost of hydrogen of $15 per kg, net electrical consumption of 5 kWh per kg dispensed, and a need for faster back-to-back vehicle refueling.  相似文献   

12.
《Renewable Energy》2007,32(3):365-381
The study deals with a solar or waste heat driven three-bed adsorption cooling cycle employing mass recovery scheme. A cycle simulation computer program is developed to investigate the performance of the chiller. The innovative chiller is driven by exploiting solar/waste heat of temperatures between 60 and 90 °C with a cooling source at 30 °C for air-conditioning purpose. The performance of the three-bed adsorption chiller with mass recovery scheme was compared with that of the three-bed chiller without mass recovery. It is found that cooling effect as well as solar/waste heat recovery efficiency, η of the chiller with mass recovery scheme is superior to those of three-bed chiller without mass recovery for heat source temperatures between 60 and 90 °C. However, COP of the proposed chiller is higher than that of the three-bed chiller without mass recovery, when heat source temperature is below 65 °C.  相似文献   

13.
Hydrogen fueling stations are emerging around and in larger cities in Europe and United States together with a number of hydrogen vehicles. The most stations comply with the refueling protocol made by society of automotive engineers and they use a cascade fueling system on-site for filling the vehicles. The cascade system at the station has to be refueled as the tank sizes are limited by the high pressures. The process of filling a vehicle and afterward bringing the tanks in refueling station back to same pressures, are called a complete refueling cycle. This study analyzes power consumption of refueling stations as a function of number of tanks, volume of the tanks and the pressure in the tanks. This is done for a complete refueling cycle. It is found that the energy consumption decreases with the number of tanks approaching an exponential function. The compressor accounts for app. 50% of the energy consumption. Going from one tank to three tanks gives an energy saving of app. 30%. Adding more than four tanks the energy saving per extra added tank is less than 4%. The optimal numbers of tanks in the cascade system are three or four.  相似文献   

14.
Hydrogen has been used as chemicals and fuels in industries for last decades. Recently, it has become attractive as one of promising green energy candidates in the era of facing with two critical energy issues such as accelerating deterioration of global environment (e.g. carbon dioxide emissions) as well as concerns on the depletion of limited fossil sources. A number of hydrogen fueling stations are under construction to fuel hydrogen-driven vehicles. It would be indispensable to ensure the safety of hydrogen station equipment and operating procedure in order to prevent any leak and explosions of hydrogen: safe design of facilities at hydrogen fueling stations e.g. pressurized hydrogen leak from storage tanks. Several researches have centered on the behaviors of hydrogen ejecting out of a set of holes of pressurized storage tanks or pipes. This work focuses on the 3D simulation of hydrogen leak scenario cases at a hydrogen fueling station, given conditions of a set of pressures, 100, 200, 300, 400 bar and a set of hydrogen ejecting hole sizes, 0.5, 0.7, 1.0 mm, using a commercial computational fluid dynamics (CFD) tool, FLACS. The simulation is based on real 3D geometrical configuration of a hydrogen fueling station that is being commercially operated in Korea. The simulation results are validated with hydrogen jet experimental data to examine the diffusion behavior of leak hydrogen jet stream. Finally, a set of marginal safe configurations of fueling facility system are presented, together with an analysis of distribution characteristics of blast pressure, directionality of explosion. This work can contribute to marginal hydrogen safety design for hydrogen fueling stations and a foundation on establishing a safety distance standard required to protect from hydrogen explosion in Korea being in the absence of such an official requirement.  相似文献   

15.
Currently, the hydrogen storage method used aboard fuel cell electric vehicles utilizes pressures up to 70 MPa. Attaining such high pressures requires mechanical gas compression or hydrogen liquefaction followed by heating to form a high-pressure gas, and these processes add to the cost and reduce the energy efficiency of a hydrogen fueling system. In previous work we have evaluated the use of high-pressure electrolysis, in which hydrogen is generated from water and the electrolyzer boosts the hydrogen pressure to values from 13 to 45 MPa. While electrolytic compression is a novel and energy efficient method to produce high-pressure hydrogen, it has several limitations at present and will require more development work. Another concept is to use hydrogen absorbing alloys that form metal hydrides, in combination with a heat engine (hot and cold reservoirs), to drive a cyclic process in which hydrogen gas is absorbed and desorbed to compress hydrogen. Furthermore, by using a thermally-driven compressor, the hot and cold reservoirs can be obtained using renewable energy such as sunlight for heating together with ambient air or water for cooling. In this work we evaluated the thermodynamics and kinetics of a prototype metal hydride hydrogen compressor (MHHC) built for us by a research group in China. The compressor utilized a hydrogen input pressure of approximately 14 MPa, and, operating between an initial temperature of approximately 300 K and a final temperature of 400 K, a pressure of approximately 41 MPa was attained. In a series of experiments with those conditions the average compression ratio for a single-stage compression was approximately three. In the initial compression cycles, up to 300 g of hydrogen was compressed for each 100 K temperature cycle. The enthalpy of the metallic-alloy-hydriding reaction was found to be approximately 20.5 kJ per mole of H2, determined by measuring the pressure composition isotherm at three temperatures and using a Van't Hoff plot. The thermodynamic efficiency of the compressor, as measured by the value of the compression work performed divided by the heat energy added and removed in one complete cycle, was determined via first and second law analyses. The Carnot efficiency was approximately 25%, the first law efficiency was approximately 3–5%, and the second law efficiency was approximately 12–20%, depending on the idealized compression cycle used to assign a value to the compression work, as well as other assumptions. These efficiencies compare favorably with values reported for other thermally-driven compressors.  相似文献   

16.
Fuel cell vehicles using green hydrogen as fuel can contribute to the mitigation of climate change. The increasing utilization of those vehicles creates the need for cost efficient hydrogen refueling stations. This study investigates how to build the most cost efficient refueling stations to fuel small fleet sizes of 2, 4, 8, 16 and 32 fuel cell busses. A detailed physical model of a hydrogen refueling station was built to determine the necessary hydrogen storage size as well as energy demand for compression and precooling of hydrogen. These results are used to determine the refueling costs for different station configurations that vary the number of storage banks, their volume and compressor capacity.It was found that increasing the number of storage banks will decrease the necessary total station storage volume as well as energy demand for compression and precooling. However, the benefit of adding storage banks decreases with each additional bank. Hence the cost for piping and instrumentation to add banks starts to outweigh the benefits when too many banks are used. Investigating the influence of the compressor mass flow found that when fueling fleets of 2 or 4 busses the lowest cost can be reached by using a compressor with the minimal mass flow necessary to refill all storage banks within 24 h. For fleets of 8, 16 and 32 busses, using the compressor with the maximum investigated mass flow of 54 kg/h leads to the lowest costs.  相似文献   

17.
The looming threat of global warming has elicited efforts to develop reliable sustainable energy resources. Hydrogen as a clean fuel is deemed a potential solution to the problem of storage of power from renewable energy technologies. Among current thermochemical hydrogen generation methods, the thermochemical copper-chlorine (Cu–Cl) cycle is of high interest owing to lower temperature requirements. Present study investigates a novel heat exchanger comprising a thermoelectric generator (TEG) to recover heat from high temperature molten CuCl exiting the thermolysis reactor. Employing casting/extrusion method, the performance of the proposed heat exchanger is numerically examined using COMSOL Multiphysics. Results indicate that maximum generated power could exceed 40 W at the matching current of 4.5 A. Maximum energy conversion efficiency yields to 7.1%. Results demonstrate that TEG performance boosts with increasing the inlet Re number, particularly at the hot end. For the molten CuCl chamber, findings denote that there is a 36% discrepancy between highest and lowest Re numbers. Similarly, the highest efficiency value pertains to the case with the highest inlet velocity. Moreover, the highest temperature difference between inlet and outlet of the cooling water is about 28 °C and 10 °C for the lowest and highest inlet Re numbers, respectively. Average deviation from anticipated friction factor and Nusselt number are 0.31% and 12.62%, respectively.  相似文献   

18.
One two-phase thermo-syphon silica gel-water solar adsorption chiller and LiBr-H2O absorption chiller with new medium CPC (Compound Parabolic Concentrator) solar collectors were investigated. The reliability of adsorption chiller can be improved, because there is only one vacuum valve in this innovative design. Medium temperature evacuated-tube CPC solar collectors were firstly utilized in the LiBr-H2O air conditioning system. The former system was applied in north of China at Latitude 37.45° (Dezhou city, China), the latter system was applied at Latitude 36.65° (Jinan city, China). Experimental results showed that the adsorption chiller can be powered by 55 °C of hot water. The adsorption chiller can provide 15 °C of chilled water from 9:30 to 17:00, the average solar COP (COPs) of the system is 0.16. In the absorption cooling system, the efficiency of the medium temperature evacuated-tube CPC solar collector can reach 0.5 when the hot water temperature is 125 °C. The absorption chiller can provide 15 °C of chilled water from 11:00 to 15:30, and the average solar COPs of absorption system is 0.19.  相似文献   

19.
Hydrogen gas generation from water in the temperature range of 10–60 °C using iron and carbon dioxide was studied. During the reaction, carbon dioxide consumption and hydrogen generation were observed, and the stoichiometry of the redox reaction with iron carbonation was checked. The rate of the reaction steadily increased with the temperature, and the time required to consume half of the carbon dioxide at 60 °C was less than one-fifth of that at 10 °C. The activation energy was determined by examining the temperature dependence of the reaction rate. Carbon dioxide used in the reaction precipitated as carbonate in the aqueous phase, covering the raw material iron and hindering the progress of hydrogen generation reaction. Experiments following the same procedure were performed using steel and sludge from steel processing, which contained elements other than iron, to show that hydrogen generation and carbon dioxide fixation were also possible.  相似文献   

20.
In this study, the performance of the combined cooling cycle with the Organic Rankine power cycle, which provides cooling of the hydrogen at the compressor inlet which compresses the constant temperature in the Claude cycle used for hydrogen liquefaction, on the system is examined. The Organic Rankine combined cooling cycle was considered to be using a geothermal source with a flow rate of 120 kg/s at a temperature of 200 °C. The first and second law performance evaluations of the whole system were made depending on the heat energy at different levels taken from the geothermal source. The thermodynamic analysis of the equipment making up the system has been done in detail. The temperature values at which the hydrogen can be effectively cooled were determined in the presented combined system. The efficiency coefficient of the total system was calculated based on varying pre-cooling values. As a result of the study, it was determined that cold entry of hydrogen into the Claude cycle reduced the energy consumption required for liquefaction. Amount of hydrogen cooled to specified temperature increase by increase in mass flow of geothermal water and its temperature. Liquefaction cost is calculated to be 0.995 $/kg H2 and electricity produced by itself is calculated to be 0.025 $/kWh by the new model of liquefaction system. Cost of the liquefaction in the proposed system is about 39.7% lower than direct value of hydrogen liquefaction of 1.650 $/kg given in the literature.  相似文献   