首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A solar-wind hybrid trigeneration system is proposed and analyzed thermodynamically through energy and exergy approaches in this paper. Hydrogen, electricity and heat are the useful products generated by the hybrid system. The system consists of a solar heliostat field, a wind turbine and a thermochemical copper-chlorine (Cu-Cl) cycle for hydrogen production linked with a hydrogen compression system. A solar heliostat field is employed as a source of thermal energy while the wind turbine is used to generate electricity. Electric power harvested by the wind turbine is supplied to the electrolyzer and compressors and provides an additional excess of electricity. Hydrogen produced by the thermochemical copper-chlorine (Cu-Cl) cycle is compressed in a hydrogen compression system for storage purposes. Both Aspen Plus 9.0 and EES are employed as software tools for the system modeling and simulation. The system is designed to achieve high hydrogen production rate of 455.1 kg/h. The overall energy and exergy efficiencies of the hybrid system are 49% and 48.2%, respectively. Some additional results about the system performance are obtained, presented and discussed in the paper.  相似文献   

2.
In this study, a new solar power assisted multigeneration system designed and thermodynamically analyzed. In this system, it is designed to perform heating, cooling, drying, hydrogen and power generation with a single energy input. The proposed study consists of seven sub-parts which are namely parabolic dish solar collector, Rankine cycle, organic Rankine cycle, PEM-electrolyzer, double effect absorption cooling, dryer and heat pump. The effects of varying reference temperature, solar irradiation, input and output pressure of high-pressure turbine and pinch point temperature heat recovery steam generator are investigated on the energetic and exergetic performance of integration system. Thermodynamic analysis result outputs show that the energy and exergy performance of overall study are computed as 48.19% and 43.57%, respectively. Moreover, the highest rate of irreversibility has the parabolic dish collector with 24,750 kW, while the lowest rate of irreversibility is calculated as 5745 kW in dryer. In addition, the main contribution of this study is that the solar-assisted multi-generation systems have good potential in terms of energy and exergy efficiency.  相似文献   

3.
The dissociation of gaseous hydrogen sulphide (H2S) into its components is an energy intensive process. The process is studied in this paper with respect to the thermodynamic limits. The band gap of the catalyst and the nature of the solar radiation limit the proportion of incoming radiation that may be used for the reaction. The intensity of the incoming radiation and the reactor temperature are varied and the performance is studied. The exergy efficiency is determined as a function of the quantum efficiency of the photochemical process, and the catalyst band gap. It is shown that an optimum case exergy efficiency of up to 28% can be achieved for the process. With the current status of technology, an exergy efficiency value in the region of 0.4–1% is calculated, with a short-term improvement potential of up to 10%. Hydrogen sulfide has high energy content, but is not widely used due to its impact on environmental pollution. The proposed process in this paper is attractive as it allows that energy to be utilized, while degrading the highly toxic gas into less harmful products.  相似文献   

4.
In this paper, we propose an integrated system, consisting of a heliostat field, a steam cycle, an organic Rankine cycle (ORC) and an electrolyzer for hydrogen production. Some parameters, such as the heliostat field area and the solar flux are varied to investigate their effect on the power output, the rate of hydrogen produced, and energy and exergy efficiencies of the individual systems and the overall system. An optimization study using direct search method is also carried out to obtain the highest energy and exergy efficiencies and rate of hydrogen produced by choosing several independent variables. The results show that the power and rate of hydrogen produced increase with increase in the heliostat field area and the solar flux. The rate of hydrogen produced increases from 0.006 kg/s to 0.063 kg/s with increase in the heliostat field area from 8000 m2 to 50,000 m2. Moreover, when the solar flux is increased from 400 W/m2 to 1200 W/m2, the rate of hydrogen produced increases from 0.005 kg/s to 0.018 kg/s. The optimization study yields maximum energy and exergy efficiencies and the rate of hydrogen produced of 18.74%, 39.55% and 1571 L/s, respectively.  相似文献   

5.
A Brayton plant-based multigenerational system is proposed and investigated thermodynamically through energetic and exergetic approaches in this study. Liquid hydrogen, electrical energy, heating-cooling and fresh water are the useful outputs produced by the combined plant. For this purpose, the Brayton cycle, organic Rankine cycle, multi-effect distillation plant, single-effect absorption cooling plant, hydrogen generation and liquefaction unit are used in the multigeneration system design. The study targets are to design a novel multigeneration system design, develop the related software codes, analyze the system thermodynamically, and evaluate the effects of plant design indicators. Thermodynamic assessment results indicate that the energy efficiency of the multigeneration system ranges between 63.64% and 74.31%, the exergy efficiency value ranges from 55.67% to 67.35%. Parametric analyses performed in this study indicate that the most influential parameter is the fuel mass flow rate. Also, it should be stated that an increase in the dead state temperature, combustion chamber temperature, and fuel mass flow rate positively affects the plant effectiveness.  相似文献   

6.
In this paper, exergy modeling is used to assess the exergetic performance of a novel trigeneration system using parabolic trough solar collectors (PTSC) and an organic Rankine cycle (ORC). Four cases are considered: electrical-power, cooling-cogeneration, heating-cogeneration, and trigeneration. In this trigeneration system a single-effect absorption chiller is utilized to provide the necessary cooling energy and a heat exchanger is utilized to provide the necessary heating energy. The trigeneration system considered is examined using three modes of operation. They are: solar mode during the low-solar radiation time of the day, solar and storage mode during the high-solar radiation time of the day, and storage mode during night time. The storage mode is operated through the heat collected in a thermal storage tank during the solar and storage mode. The exergy efficiencies and exergy destruction rates are examined under the variation of the ORC evaporator pinch point temperature, ORC pump inlet temperature, and turbine inlet pressure. This study reveals that the maximum electrical-exergy efficiency for the solar mode is 7%, for the solar and storage mode is 3.5%, and for the storage mode is 3%. Alternatively, when trigeneration is used, the exergy efficiency increases noticeably. The maximum trigeneration-exergy efficiency for the solar mode is 20%, for solar and storage mode is 8%, and for the storage mode is 7%. Moreover, this study shows that the main sources of exergy destruction rate are the solar collectors and ORC evaporators. Therefore, careful selection and design of these two components are essential to reduce the exergy destructed by them and, thus, increase the exergy efficiencies of the system.  相似文献   

7.
In this study, an integrated multigeneration system that can produce hydrogen, electricity, heat, and methanol simultaneously is thermodynamically investigated. This integrated multigeneration system consists of three subsystems, namely: (i) electrolyzer, (ii) thermal power plant; and (iii) methanol production reactor. Energy and exergy analyses of all system components, as well as the sustainability analysis of the whole system, is performed thoroughly. The integrated system's thermodynamic performance is thoroughly investigated by changing some critical operational and environmental parameters in parametric studies. Based on the results of this study, recommendations for better energetic, exergetic, and environmental performance are presented for better sustainability. The results of this study show that the integrated multigeneration system is capable of producing hydrogen, heat, electricity, and methanol with overall energetic and exergetic efficiencies about 68% and 47%, respectively.  相似文献   

8.
In the present work, an advanced hydrogen liquefaction system with catalyst infused heat exchangers is proposed, analyzed and assessed energetically and exergetically. The analysis starts with exergetic considerations on hydrogen liquefaction using different alternatives of pre-cooling including the conversion from normal to parahydrogen. It further explains the fundamentals of a proposed liquefaction process. The goal is then to assess the proposed system, make modifications and improve the system. The present system covers all of these portions of a hydrogen liquefaction system with an ultimate goal of achieving a sustainable and environmentally harmless system. The proposed hydrogen liquefaction system is simulated in the Aspen Plus and the performance of the system is measured through energy and exergy efficiencies. The resulting energy efficiency of the system is calculated to be 15.4%, and the exergy efficiency of the system is found to be 11.5%.  相似文献   

9.
Energy and exergy analyses of an integrated system based on anaerobic digestion (AD) of sewage sludge from wastewater treatment plant (WWTP) for multi-generation are investigated in this study. The multigeneration system is operated by the biogas produced from digestion process. The useful outputs of this system are power, freshwater, heat, and hydrogen while there are some heat recoveries within the system for improving efficiency. An open-air Brayton cycle, as well as organic Rankine cycle (ORC) with R-245fa as working fluid, are employed for power generation. Also, desalination is performed using the waste heat of power generation unit through a parallel/cross multi-effect desalination (MED) system for water purification. Moreover, a proton exchange membrane (PEM) electrolyzer is used for electrochemical hydrogen production option in the case of excess electricity generation. The heating process is performed via the rejected heat of the ORC's working fluid. The production rates for products including the power, freshwater, hydrogen, and hot water are obtained as 1102 kW, 0.94 kg/s, 0.347 kg/h, and 1.82 kg/s, respectively, in the base case conditions. Besides, the overall energy and exergy efficiencies of 63.6% and 40% are obtained for the developed system, respectively.  相似文献   

10.
In this paper, thermodynamic analysis and assessment of a novel geothermal energy based integrated system for power, hydrogen, oxygen, cooling, heat and hot water production are performed. This integrated process consists of (a) geothermal subsystem, (b) Kalina cycle, (c) single effect absorption cooling subsystem and (d) hydrogen generation and storage subsystems. The impacts of some design parameters, such as absorption chiller evaporator temperature, geothermal source temperature, turbine input pressure and pinch point temperature on the integrated system performance are investigated to achieve more efficient and more effective. Also, the impacts of reference temperature and geothermal water temperature on the integrated system performance are studied in detail. The energetic and exergetic efficiencies of the integrated system are then calculated as 42.59% and 48.24%, respectively.  相似文献   

11.
In this study, we investigate a solar-assisted biomass gasification system for hydrogen production and assess its performance thermodynamically using actual literature data. We also analyze the entire system both energetically and exergetically and evaluate its performance through both energy and exergy efficiencies. Three feedstocks, namely beech charcoal, sewage sludge and fluff, are considered as samples in the same reactor. While energy efficiencies vary from 14.14% to 27.29%, exergy efficiencies change from 10.43% to 23.92%. We use a sustainability index (SI), as a function of exergy efficiency, to calculate the impacts on sustainable development and environment. This index changes from 1.12 to 1.31 due to intensive utilization of solar energy. Also, environmental impact of these systems is evaluated through calculating the specific greenhouse gas (GHG) emissions. They are determined to be 17.97, 17.51 and 26.74 g CO2/MJ H2 for beech charcoal, sewage sludge and fluff, respectively.  相似文献   

12.
In this paper, the thermodynamic study of a combined geothermal power-based hydrogen generation and liquefaction system is investigated for performance assessment. Because hydrogen is the energy of future, the purpose of this study is to produce hydrogen in a clear way. The results of study can be helpful for decision makers in terms of the integrated system efficiency. The presented integrated hydrogen production and liquefaction system consists of a combined geothermal power system, a PEM electrolyzer, and a hydrogen liquefaction and storage system. The exergy destruction rates, exergy destruction ratios and exergetic performance values of presented integrated system and its subsystems are determined by using the balance equations for mass, energy, entropy, energy and exergy and evaluated their performances by means of energetic and exergetic efficiencies. In this regard, the impact of some design parameters and operating conditions on the hydrogen production and liquefaction and its exergy destruction rates and exergetic performances are investigated parametrically. According to these parametric analysis results, the most influential parameter affecting system exergy efficiency is found to be geothermal source temperature in such a way that as geothermal fluid temperature increases from 130 °C to 200 °C which results in an increase of exergy efficiency from 38% to 64%. Results also show that, PEM electrolyzer temperature is more effective than reference temperature. As PEM electrolyzer temperature increases from 60 °C to 85 °C, the hydrogen production efficiency increases from nearly 39% to 44%.  相似文献   

13.
In this paper, a comprehensive study on thermodynamic analysis and assessment, through energy and exergy approaches, is conducted for a multigenerational solar based integrated energy system. The system proposed in this study is based on heliostat solar system integrated with steam turbine. The system is also integrated with seawater reverse osmosis desalination unit and absorption cooling system. The desalination unit operates with energy recovery through the utilization of Pelton turbine. The system produces cooling, heating, fresh water and hydrogen through electrolysis. It is furthermore designed to cover the demand of 4 MW electric power with the production of 1.25 kg/h of hydrogen and 90 kg/s of fresh water. The system advisor model software is applied on a case study for the solar heliostat optimization analysis.  相似文献   

14.
The current study investigates a holistically developed solar energy system combined with a ground-sourced heat pump system for stand-alone usage to produce power, heat, and cooling along with domestic hot water for residential buildings. An integrated system is proposed where three types of building-integrated photovoltaic plant orientation are considered and integrated with a vertical-oriented ground-sourced heat pump system as well as an anion exchange membrane electrolyser for hydrogen-based energy storage along with proton exchange membrane fuel cells. The ground-sourced heat pump system covers the heating requirements and exploits the available thermal energy under the ground. Hydrogen subsystem enables the integrated system to be used anytime by compensating the peak periods with stored hydrogen via fuel cell and exploiting the excess energy to produce hydrogen via electrolyser. The photovoltaic plant orientations are extensively designed by considering geometries of three different applications, namely, rooftop photovoltaic, building-integrated photovoltaic façade and photovoltaic canopy. The shading and geometrical losses of photovoltaic applications are extensively identified and considered. In addition, the openly available high-rise building load profiles are obtained from the OpenEI network and are modified accordingly to utilize in the current study. The building requirements are considered for 8760 h annually with meteorological data and energy usage characteristics of the selected regions. The integrated system is assessed via thermodynamic-based approach from energy and exergy points of views. In order to increase generality, the proposed building energy system is analyzed for five different cities around the globe. The obtained results show that a 20-floor building with approximately 62,680 m2 residential area needs between 550 kWp and 1550 kWp of a photovoltaic plant in five different cities. For Ottawa, Canada, the overall energy and exergy efficiencies are found as 18.76% and 10.49%, respectively, in a typical meteorological year. For the city of Istanbul in Turkey, a 20-floor building is found to be self-sufficient by only using the building's surface area with a 495 kWp BIPV façade and a 90 kWp rooftop PV.  相似文献   

15.
The purpose of this paper is to conduct a parametric study to show the best steam to carbon ratio that produces the maximum system performance of an integrated gasifier for hydrogen production. The study focuses on the energy and exergetic efficiency of the system and hydrogen production. The work is completed using computer simulation models in Engineering Equation Solver software package. This software is used for its extensive thermodynamic properties library. An equilibrium based model is used to determine the performance of the system. The data is presented in graphs which show the chemical composition in molar fractions of the syngas, the overall energy and exergy efficiency of the system, and the hydrogen production rates. A study of these parameters is conducted by varying the steam to carbon ratio entering the gasifier and the ambient temperature. It is observed that the higher the steam to carbon ratio that is achieved the more hydrogen and more power the plant is able to produce. Because of this, the exergy and energy efficiency of the system increases as the steam to carbon ratio increases as well. It is also observed that the system favors a lower ambient temperature for maximum exergy efficiency and hydrogen production.  相似文献   

16.
The performance of a clean energy system that combines the coal gasification and alkaline water electrolyzer concepts to produce hydrogen is evaluated through thermodynamic modeling and simulations. A parametric study is conducted to determine the effect of water ratio in coal slurry, gasifier temperature, effectiveness of carbon dioxide removal, and hydrogen recovery efficiency of the pressure swing adsorption unit on the system hydrogen production. The exergy efficiency and exergy destruction in each system component are also evaluated. The results reveal that the overall energy and exergy efficiencies of this system are ∼58% and ∼55%, respectively. The weight ratio of the hydrogen yielded to the coal fed to this system is ∼0.126. Although this system produces hydrogen from coal, the greenhouse gases emitted from this system are fairly low.  相似文献   

17.
In the present study, a novel supercritical hydrogen liquefaction process based on helium cooled hydrogen liquefaction cycles to produce liquid hydrogen is thermodynamically analyzed and assessed. The exergy analysis approach is used to study the exergy destruction rates in each component and the process efficiency. The energy and exergy efficiencies of liquefaction process are found to be 70.12% and 57.13%, respectively. In addition, to investigate the process efficiency more comprehensively to see how it is affected by varying process parameters and operating conditions, some parametric studies are undertaken to examine the impacts of different design variables on the energy efficiency, exergy efficiency and exergy destruction rates of the hydrogen liquefaction process. The results show that the increases in the cycle pressure of hydrogen and helium result in increasing hydrogen liquefaction process exergy efficiency and providing a smaller pinch point temperature difference of catalyst beds related with the heat transfer surface area and more efficiently process.  相似文献   

18.
Electrochemical hydrogen compression (EHC) is a promising alternative to conventional compressors for hydrogen storage at high pressure, because it has a simple structure, low cost of hydrogen delivery, and high efficiency. In this study, the performance of an EHC is evaluated using a three-dimensional numerical model and finite volume method. The results of numerical analysis for a single cell of EHC are extended to a full stack of EHC. In addition, exergy and exergoeconomic analyses are carried out based on the numerical data. The effects of operating temperature, pressure, and gas diffusion layer (GDL) thickness on the energy and exergy efficiencies and the exergy cost of hydrogen are examined. The motivation of this study is to examine the performance of the EHC at different working conditions and also to determine the exergy cost of hydrogen. The results reveal that the energy and exergy efficiency of EHC stack improve by almost 3.1% when operating temperature increases from 363 K to 393 K and the exergy cost of hydrogen decreases by 0.5% at current density of 5000 A m−2. It is concluded that energy and exergy efficiency of EHC stack decrease by 25% and 5.4% when the cathode pressure increases from 1 bar to 30 bar, respectively. Moreover, it is realized that the GDL thickness has a considerable effect on the EHC performance. The exergy cost of hydrogen decreases by 53% when the GDL thickness decreases from 0.5 mm to 0.2 mm at current density of 5000 A m−2.  相似文献   

19.
In this study, we present the thermodynamic feasibility analysis of a two-step hydrogen chloride cycle for sustainable hydrogen production. Exergy approach in addition to conventional energy approach is utilized to study the performance of the cycle. Here, a solid oxide membrane for the gas phase electrolysis of hydrogen chloride is employed and the temperature change between the cycle steps is eliminated for better thermal management. Moreover, a parametric study is conducted to observe the cycle variation with certain parameters such as operating temperature, current density, and hydrogen production rate. The calculated results show that with the use of the current cycle, one can produce 1 kg/s of hydrogen with the consumption of 335.8 MW electricity and 29.2 MW of thermal energy. Additionally, two different definitions of energy and exergy efficiencies are introduced to investigate the difference between actual and ideal (theoretical) cycle performances. The proposed cycle can be effectively used to produce hydrogen using concentrated solar and nuclear waste heat at high temperatures.  相似文献   

20.
In this thermodynamic investigation, an integrated energy system based on hydrogen fuel is developed and studied energetically and exergetically. The liquefied hydrogen fueled solid oxide fuel cell (SOFC) based system is then integrated with a steam producing cycle to supply electricity and potable water to ships. The first heat recovery system, after the fuel cells provide thrust for the ship, is by means of a turbine while the second heat recovery system drives the ship's refrigeration cycle. This study includes energy and exergy performance evaluations of SOFC, refrigeration cycle and ship thrust engine systems. Furthermore, the effectiveness of SOFCs and a hydrogen fueled engine in reducing greenhouse gas emissions are assessed parametrically through a case study. The main propulsion, power generation from the solid oxide fuel cells, absorption chiller, and steam bottoming cycle systems together have the overall energy and exergy efficiencies of 41.53% and 37.13%, respectively.  相似文献   