In this paper, a compact 3 kW air-cooled fuel cell stack consists of 95 single cells with metallic bipolar plate is designed. Compared with graphite bipolar plates, metal stamping bipolar plates are lighter in weight, smaller in size and faster in heat conduction, therefore the transient behaviors of the voltage and temperature of each cell are analyzed. The results show that the heat distribution of the air-cooled fuel cell is very uniform, and the temperature difference between the inlet and outlet of cathode air of the fuel cell is lower than 15 °C. The individual cell voltage uniformity percentage variation value reaches 7% when the drop in the loading current is over 25 A. Moreover, the voltage uniformity variation value is higher than 4% when the loading current output exceeds 35A. Thus, a large drop in loading and a high loading current easily increase the voltage uniformity variation value. Long-term continuous operation has a negative influence on the performance of the stack, especially the last fuel cell near the anode outlet. Anode purging can effectively alleviate the uniformity percentage variation in the voltages. The designed air-cooled fuel cell exhibits good performance and strong environmental adaptability.  相似文献   

2.
The temperature gradient inside an open-cathode air-cooled fuel cell is large because it uses air as its reaction and cooling media; moreover, the temperature of single cells near the endplates is low because of the high heat capacity of the endplate compared to single cells. Therefore, the cold start of open-cathode air-cooled fuel cells is difficult. In this work, the cold-start performance of an open-cathode air-cooled fuel cell stack, including the stack voltage, single-cell voltage and temperature distribution, are tested in a climatic chamber. The results show that the endplate effect has a significant adverse influence on the cold-start performance. Due to the existence of the endplate effect, the voltages of the single cells near the endplate decrease significantly. The stack can be successfully started at −5 °C without any external heating; however, when the temperature decreases below −10 °C, it cannot be started. At this time, if a certain power of endplate heating is adopted, successful cold-start can be achieved. However, if the temperature continues to decrease, the stack cannot be successfully started only through endplate heating because both the endplates and cold air affect the cold-start performance. Combining endplate and air heating may be a feasible cold-start method.  相似文献   

3.
Combining the oxidant and coolant flow in an air-cooled proton exchange membrane fuel cell can significantly simplify the fuel cell design. In this paper, an air-cooled PEM fuel cell stack with an open cathode flow field, which supplied the oxidant and removed the heat produced in the fuel cell, was fabricated and tested. The influence of different operating parameters on cell voltage performance and the overall cell ohmic resistance, such as cell temperature and airflow rate, was investigated. The cell temperature and the temperature difference between the cell and the hydrogen humidifier were shown to serve important roles in reducing the fuel cell ohmic resistance. The test results also showed a noteworthy temperature gradient between each cell of a 5-cell stack. A hydrophilic treatment of the cathode flow field channels was demonstrated to be an effective way to mitigate water management issues caused at elevated operating temperatures.  相似文献   

4.
This work experimentally investigates the effects of the pyrolytic graphite sheets (PGS) on the performance and thermal management of a proton exchange membrane fuel cell (PEMFC) stack. These PGS with the features of light weight and high thermal conductivity serve as heat spreaders in the fuel cell stack for the first time to reduce the volume and weight of cooling systems, and homogenizes the temperature in the reaction areas. A PEMFC stack with an active area of 100 cm2 and 10 cells in series is constructed and used in this research. Five PGS of thickness 0.1 mm are cut into the shape of flow channels and bound to the central five cathode gas channel plates. Four thermocouples are embedded on the cathode gas channel plates to estimate the temperature variation in the stack. It is shown that the maximum power of the stack increase more than 15% with PGS attached. PGS improve the stack performance and alleviate the flooding problem at low cathode flow rates significantly. Results of this study demonstrate the feasibility of application of PGS to the thermal management of a small-to-medium-sized fuel cell stack.  相似文献   

5.
Air-breathing proton exchange membrane (PEM) fuel cells provide for fully or partially passive operation and have gained much interest in the past decade, as part of the efforts to reduce the system complexity. This paper presents a detailed physics-based numerical analysis of the transport and electrochemical phenomena involved in the operation of a stack consisting of an array of vertically oriented air-breathing fuel cells. A comprehensive two-dimensional, nonisothermal, multi-component numerical model with pressurized hydrogen supply at the anode and natural convection air supply at the cathode is developed and validated with experimental data. Systematic parametric studies are performed to investigate the effects of cell dimensions, inter-cell spacing and the gap between the array and the substrate on the performance of the stack. Temperature and species distributions and flow patterns are presented to elucidate the coupled multiphysics phenomena. The analysis is used to determine optimum stack designs based on constraints on desired performance and overall stack size.  相似文献   

6.
A dynamic model of a high-temperature proton exchange membrane fuel cell with a fuel processor is developed in this study. In the model, a fuel processing system, a fuel cell stack, and an exhaust gas burner are modeled and integrated. The model can predict the characteristics of the overall system and each component at the steady and transient states. Specifically, a unit fuel cell model is discretized in a simplified quasi-three-dimensional geometry; therefore, the model can rapidly predict the distribution of fuel cell characteristics. Various operating conditions such as the steam-to-carbon ratio, oxygen-to-carbon ratio, and autothermal reforming inlet temperature are varied and investigated in this study. In addition, the dynamic characteristics exhibited during the transient state are investigated, and an efficiency controller is developed and implemented in the model to maintain the electrical efficiency. The simulation results demonstrate that the steam-to-carbon ratio and the oxygen-to-carbon ratio affect the electrical and system efficiency and that controlling the fuel flow rate maintains the electrical efficiency in the transient state. The model may be a useful tool for investigating the characteristics of the overall system as well as for developing optimal control strategies for enhancing the system performance.  相似文献   

7.
In the previous researches, researchers mainly focus on the single cell which is far away from the practical application. In this paper, shut-down process is studied in a 5-cell stack with segment technology. In the unprotected group, the hydrogen/air boundary is observed, and the output voltage performance degrades greatly after 300 start-stop cycles. A 2-phase auxiliary load strategy is proposed to avoid the hydrogen/air boundary. The lifetime is extended. But a serious local starvation is observed during the shut-down process. And corrosion happened in the inlet region. To avoid the starvation, the second strategy is designed, which combines 2-phase auxiliary and air purge (2-phase load& air purge strategy). With the new strategy, the degradation of the stack after 1500 cycles is acceptable, and the carbon corrosion in the inlet is effectively reduced. It could conclude that the hydrogen/air boundary is the main cause of the degradation of fuel cell during an unprotected shut-down process. And a strategy only with auxiliary load may suffer from the local starvation. The purge process can avoid the vacuum effect in the fuel cell caused by the auxiliary load. Therefore, adding an air purge during the shut-down process is promising in vehicle fuel cell.  相似文献   

8.
A numerical model of a proton exchange membrane fuel cell (PEMFC) cathode with a tapered channel design has been developed in order to examine the dynamic behavior of liquid water transport. Three-dimensional, transient simulations employing the level-set method (available in COMSOL 3.5a, a commercial finite element method software) have been used to explicitly track the liquid-gas interface. A liquid water droplet suspended in the center of the channel, 2 mm from the channel entrance, is subjected to airflow in the bulk of the channel. Three different cases have been studied: 1) hydrophobic bottom wall representing the gas diffusion layer and hydrophilic channel top and side walls, 2) all walls are partially wetted i.e. having a contact angle of 90°, 3) a hydrophilic bottom wall and hydrophobic top and side walls. The results show that tapering the channel downstream helps in water exhaust due to increased airflow velocity. A bottom wall, although hydrophilic, results in fast removal of water droplet as compared to partially wetted and hydrophobic bottom surfaces.  相似文献   

9.
A proton exchange membrane fuel cell (PEMFC) cogeneration system that provides high-quality electricity and hot water has been developed. A specially designed thermal management system together with a microcontroller embedded with appropriate control algorithm is integrated into a PEM fuel cell system. The thermal management system does not only control the fuel cell operation temperature but also recover the heat dissipated by FC stack. The dynamic behaviors of thermal and electrical characteristics are presented to verify the stability of the fuel cell cogeneration system. In addition, the reliability of the fuel cell cogeneration system is proved by one-day demonstration that deals with the daily power demand in a typical family. Finally, the effects of external loads on the efficiencies of the fuel cell cogeneration system are examined. Results reveal that the maximum system efficiency was as high as 81% when combining heat and power.  相似文献   

10.
The hydrogen recirculation in proton exchange membrane fuel cell (PEMFC) is recommended for the hydrogen supply of PEMFC, and hydrogen ejectors are gradually being used in fuel cell vehicles due to low noise and low energy consumption. However, there is a lack of discussion about the influence of recirculation rate on the stack. Due to passive regulating mechanism of the ejectors, a miniature speed-adjustable peristaltic pump is used to simulate the hydrogen ejector in this study to investigate the effect of hydrogen recirculation on the performance of PEMFC stack. Experiments are conducted under different pump flow rates. The stack with hydrogen recirculation is proven to have better performance, but over high pump flow rate can lead to hydrogen shortage. It is interesting to find that the flow rate fluctuation of hydrogen inlet affects the stability of stack performance, and pressure drop and recovery time during purge process are proposed as effective indicators for performance analysis. Finally, pump flow rates between 60 ml/min and 105 ml/min are defined as “effective area”. Based on the analysis of effective indicators, keeping at “effective area” is further proved to improve the performance of the stack, which is also useful to design hydrogen recirculation.  相似文献   

11.
In this paper, a pore network model is developed to investigate the coupled transport and reaction processes in the cathode catalyst layer (CCL) of proton exchange membrane fuel cell (PEMFC). The developed model is validated by comparing the predicted polarization curve with the experimental data, and the parametric studies are carried out to elucidate the effects of CCL design parameters. With the decrease of the CCL thickness and the Nafion content, the cell voltage reduces at the low current density but increases when the current density is higher. The cell performance is also improved by increasing the proton conductivity of the Nafion film in the CCL. As compared to the CCL of uniformly distributed Nafion, the CCL with the Nafion volume decreasing along the thickness direction exhibits better performance at the high current density.  相似文献   

12.
Air-breathing is known as a way to reduce the weight, volume, and the cost of PEMFCs. In this study, the thermal management of the high-powered air-breathing PEMFC stacks by applying different cathode flow channel configurations is carried out to improve the stack performance. In order to verify the thermal management results, numerical simulation is also performed. The research results show that a combination of the 50% and 58.3% opening ratios in the air-breathing stack reduces the stack temperature and enhances the temperature distribution uniformity, leading to a better and more stable stack performance. In addition, it is found that the stack performance is significantly improved under the assisted-air-breathing condition. Moreover, the simulation results and the experimental data are basically consistent. It is suggested to adopt the average temperature over the cross-sectional flow region from simulation as fitting the simulation results and the measured data.  相似文献   

13.
Many places experience extreme temperatures below −30 °C, which is a great challenge for the fuel cell vehicle (FCV). The aim of this study is to optimize the strategy to achieve rapid cold start-up of the 30-cell stack at different temperature conditions. The test shows that the stack rapidly starts within 30 s at an ambient temperature of −20 °C. Turning on the coolant at −25 °C show stability of the cell voltage at both ends due to the end-plate heating, however, voltage of intermediate cells fluctuates sharply, and successful start-up is completed after 60 s. The cold start strategy changes to load-voltage cooperative control mode when the ambient temperature reduced to −30 °C, the voltage of multiple cells in the middle of the stack fluctuate more drastic, and start-up takes 113 s. The performance and consistency of the stack did not decay after 20 cold start-up experiments, which indicates that our control strategies effectively avoided irreversible damage to the stack caused by freeze-thaw process.  相似文献   

14.
Proton exchange membrane fuel cells (PEMFCs) are devices that attract the interest for a variety of applications including portable devices, transportation and stationary power. Several models are available in the literature concerning PEMFCs with different modelling approaches. In this paper, two representative dynamic models are examined, one using an electrical equivalent and one based on semi-empirical equations. Moreover, an enhanced model based on semi – empirical equations and a simplified transfer function representation for the dynamic response is proposed. All models can be easily incorporated in power system simulation software. Scope of this paper is to present a parametric analysis method in order to determine the ability of each model to represent accurately the steady – state as well as the slow and fast dynamics of a PEMFC. The influence of each specific parameter is investigated and the tuning procedure is described. Finally, simulation results are presented and the adaptability of all models is evaluated.  相似文献   

15.
The number of working points and response speed are two essential characteristics of proton exchange membrane fuel cell (PEMFC). The improper setting of the number of working points and response speed may reduce the life of PEMFC and increase the hydrogen consumption of the vehicle. This paper explores the impact of the response speed as well as the working points of the PEMFC on the hydrogen consumption in the real-system level. In this paper a dynamic model of the PEMFC system is established and verified by experiments. The model is able to reflect the dynamic response process of PEMFC under a series different number of working points and different response speed. Based on the proposed model, the influence of working points and the response speed of PEMFC on the hydrogen consumption in the vehicle under different driving cycles is analyzed and summarized, for the first time, in the open literature. The results highlight that the hydrogen consumption will decreases in both cases that with the increase of working point number and increase of response speed. However, the reduction range of hydrogen consumption trends to smaller and may reach to an optimal level considering the trade-off between the hydrogen saving and the other costs, for example the control cost. Also, with a more complex driving cycle, the working points and response speed have a greater the impact on the hydrogen consumption in the vehicle applications.  相似文献   

16.
Durability is an important issue in proton exchange membrane fuel cells (PEMFCs) currently. Fuel starvation could be one of the reasons for PEMFC degradation. In this research, the fuel starvation conditions of a unit cell in a stack are simulated experimentally. Cell voltage, current distribution and localized interfacial potentials are detected in situ to explore their behaviors under different hydrogen stoichiometries. Results show that the localized fuel starvation occurs in different sections at anode under different hydrogen stoichiometries when the given hydrogen is inadequate. This could be attributed to the “vacuum effect” that withdraws fuel from the manifold into anode. Behaviors of current distribution show that the current will redistribute and the position of the lowest current shifts close to the anode inlet with decreasing hydrogen stoichiometry, which indicates that the position of the localized fuel starvation would move towards the inlet of the cell. It is useful to understand the real position of the degradation of MEA.  相似文献   

17.
In this investigation, hydrophobic dodecylamine-modified carbon supports are prepared for proton exchange membrane fuel cells by organic synthesis. Well-dispersed Pt-Ru nanoparticles, with a narrow size distribution, are then deposited on the dodecylamine-modified carbon supports by methanol reduction to serve as cathodic catalysts. These dodecylamine-modified catalysts are separately mixed with either a commercial catalyst or unmodified catalyst to provide hydrophobic channels to convey the reaction gas to the active sites in the catalyst layer. The best cathode composite catalyst, containing 20-40 wt% of modified-catalyst, gives approximate 30% increase in the maximum power density, comparing to E-TEK catalyst (125 mW cm−2). The increase in the maximum power density is attributed to higher activity and lower resistance. This result is discussed in the context of AC-impedance and proton conductivity analysis.  相似文献   

18.
The modeling of proton exchange membrane fuel cells (PEMFC) may work as a powerful tool in the development and widespread testing of alternative energy sources in the next decade. In order to obtain a suitable PEMFC model, which can be used in the analysis of fuel cell-based power generation systems, it is necessary to define the values of a specific group of modeling parameters. In this paper, the authors propose a dynamic model of PEMFC, the originality of which lays on the use of non-integer derivatives to model diffusion phenomena. This model has the advantage of having least number of parameters while being valid on a wide frequency range and allows simulating an accurate dynamic response of the PEMFC.

In this model, the fuel cell is represented by an equivalent circuit, whose components are identified with the experimental technique of electrochemical impedance spectroscopy (EIS). This identification process is applied to a commercially available air-breathing PEMFC and its relevance is validated by comparing model simulations and laboratory experiments. Finally, the dynamic response derived from this fractional model is studied and validated experimentally.  相似文献   


19.
The proton exchange membrane fuel cell (PEMFC) system with a shell-and-tube gas-to-gas membrane humidifier is considered to be a promising PEMFC system because of its energy-efficient operation. However, because the relative humidity of the dry air flowing into the stack depends on the stack exhaust air, this system can be unstable during transients. To investigate the dynamic behavior of the PEMFC system, a system model composed of a lumped dynamic model of an air blower, a two-dimensional dynamic model of a shell-and-tube gas-to-gas membrane humidifier, and a one-dimensional dynamic model of a PEMFC system is developed. Because the water management during transient of the PEMFC system is one of the key challenges, the system model is simulated at the step change of current. The variations in the PEMFC system characteristics are captured. To confirm the superiority of the system model, it is compared with the PEMFC component model during transients.  相似文献   

20.
This work characterizes the thermal management of a proton exchange membrane fuel cell (PEMFC) stack with combined passive and active cooling. A 10-cell PEMFC stack with an active area of 100 cm2 for each cell is constructed. Six thermally conductive 0.1-mm-thick Pyrolytic Graphite Sheets (PGSs) are cut into the shape of flow channels and bound to the six central cathode gas channel plates. These PGSs, which are lightweight and have high thermal conductivity, function as heat spreaders and fins and provide passive cooling in the fuel cell stack, along with two small fans for forced convection. Three other cooling configurations with differently sized fans are also tested for comparisons (without PGSs). Although the maximum power generated by the stack with the configuration combining PGSs and fans was 183 W, not the highest among all configurations, it significantly reduced the volume, weight, and cooling power of the thermal management system. Net power, specific power, volumetric power density, and back work ratio of this novel thermal management method are 179 W, 18.54 W kg−1, 38.9 kW m−3, and 2.1%, respectively, which are superior to those of the other three cooling configurations with fans.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号