首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The design and construction of a polymer electrolyte membrane fuel cell (PEMFC) system test bench suitable for investigating the effects of inert gas build-up and hydrogen quality on the performance of PEMFC systems is reported. Moreover, a new methodology to measure the inert gas crossover rate using an on-line hydrogen concentration sensor is introduced, and preliminary results are presented for an aged 8 kW PEMFC stack. The system test bench was also characterized using the same stack, whereupon its performance was observed to be close to commercial systems. The effect of inert gas accumulation and hence the quality of hydrogen on the performance of the system was studied by diluting hydrogen gas in the anode supply pipeline with nitrogen. During these experiments, uneven performance between cells was observed for the aged stack.  相似文献   

2.
For analyzing ejector's performance in the system, an ejector for a 10 kW polymer electrolyte membrane fuel cell (PEMFC) system was first designed, manufactured, and a 10 kW PEMFC system bench was built up. A proportional valve and PI pressure feedback control method were adopted to control the hydrogen supply and anode inlet pressure. During the test, performances between dead-ended anode (DEA) mode and ejector mode were compared. Ejector's performances in the system, i.e., volume flow recirculated ratio, difference pressure, dynamic responses of primary pressure, anode inlet pressure, and recirculated gas flow rate during the purge process and current variation condition, were investigated. The results show that pressure adjustment is accurate, continuous, and fast using the proportional valve and PI pressure feedback control method. The hydrogen consumption rate in the ejector mode can reduce from 5% to 10% compared with the rate in the DEA mode except for the stack current 5 A and 10 A conditions. For better water removal out of the anode channel in ejector mode, the maximum stack power increases from 5.11 kW (DEA mode) to 9.56 kW (ejector mode). Anode pressure surge caused by the purge valve switching enhances the ejector's recirculated performance significantly.  相似文献   

3.
In order to eliminate the local CO2 emissions from vehicles and to combat the associated climate change, the classic internal combustion engine can be replaced by an electric motor. The two most advantageous variants for the necessary electrical energy storage in the vehicle are currently the purely electrochemical storage in batteries and the chemical storage in hydrogen with subsequent conversion into electrical energy by means of a fuel cell stack. The two variants can also be combined in a battery electric vehicle with a fuel cell range extender, so that the vehicle can be refuelled either purely electrically or using hydrogen. The air compressor, a key component of a PEM fuel cell system, can be operated at different air excess and pressure ratios, which influence the stack as well as the system efficiency. To asses the steady state behaviour of a PEM fuel cell range extender system, a system test bench utilising a commercially available 30 kW stack (96 cells, 409 cm2 cell area) was developed. The influences of the operating parameters (air excess ratio 1.3 to 1.7, stack temperature 20 °C–60 °C, air compressor pressure ratio up to 1.67, load point 122 mA/cm2 to 978 mA/cm2) on the fuel cell stack voltage level (constant ambient relative humidity of 45%) and the corresponding system efficiency were measured by utilising current, voltage, mass flow, temperature and pressure sensors. A fuel cell stack model was presented, which correlates closely with the experimental data (0.861% relative error). The air supply components were modelled utilising a surface fit. Subsequently, the system efficiency of the validated model was optimised by varying the air mass flow and air pressure. It is shown that higher air pressures and lower air excess ratios increase the system efficiency at high loads. The maximum achieved system efficiency is 55.21% at the lowest continuous load point and 43.74% at the highest continuous load point. Future work can utilise the test bench or the validated model for component design studies to further improve the system efficiency.  相似文献   

4.
The proton exchange membrane fuel cell (PEMFC) stacks are not widely used in the field of transportation industry, due to their limited power. Thus, the PEMFC stacks usually connected in parallel or series to meet the load demand power in high-power applications. The hydrogen consumption of multi-stack fuel cells (MFCs) system is related to the efficiency and output power. In addition, the efficiency of PEMFC depends on the applied voltage and other parameters. Consequently, the hydrogen consumption of system changes with varying load, because the system parameters are also varying. It makes reducing the fuel consumption of system a challenging assignment. In order to achieve the goal of minimizing fuel consumption of parallel-connected PEMFCs system, this paper proposes a novel power distribution strategy based on forgetting factor recursive least square (FFRLS) online identification. The FFRLS algorithm is based on data-driven and uses real-time data of the system to improve the estimation accuracy of PEMFC system parameters. On the test bench of parallel-connected PEMFCs system consists of two 300 W PEMFC stacks, PEMFC stack controller, DC/DC converters, and DSP controller etc., a multi-index performance test and comparative analysis are carried out. The results showed that, the performance of proposed power allocation strategy has been successfully validated. In addition, compared with the power average and daisy chain algorithms, the proposed online identification power distribution method can get more satisfactory results. Such as, reducing the hydrogen consumption and improving efficiency.  相似文献   

5.
Proton-exchange membrane fuel cell (PEMFC) and liquid hydrogen are gaining attention as a power generation system and alternative fuel of ship. This study proposes a novel PEMFC system, integrated with the organic Rankine cycle–direct expansion cycle (ORC-DEC), which exploits cold exergy from liquid hydrogen and low temperature waste heat generated by the PEMFC for application in a liquid hydrogen fueled ship. A thermodynamic model of each subsystem was established and analyzed from the economic, energy, and exergy viewpoints. Moreover, parametric analysis was performed to identify the effects of certain key parameters, such as the working fluid in the ORC, pressure exerted by the fuel pump, cooling water temperature of the PEMFC, and the stack current density on the system performance. The results showed that the proposed system could generate 221 kW of additional power. The overall system achieved an exergy and energy efficiency of 43.52 and 40.45%, respectively. The PEMFC system had the largest exergy destruction, followed by the cryogenic heat exchanger. Propane showed the best performance among the several investigated ORC working fluids and the system performance improved with the increase in the cooling water temperature of the PEMFC. The economic analysis showed that the average payback time of ORC-DEC was 11.2 years and the average net present value (NPV) was $295,268 at liquid hydrogen costing $3 to $7, showing the potential viability of the system.  相似文献   

6.
7.
In the state-of-the-art high-power self-humidifying proton exchange membrane fuel cell (PEMFC) systems for vehicles, the high potential and low water production at idle or low load conditions strongly cause corrosion and decay of key materials and thus reduce durability. Therefore, the control technology of system-level durability requires an innovative design. Cathode recirculation is beneficial in alleviating the above unfavorable factors from the perspective of regulating oxygen and vapor partial pressure. This paper presents a pioneering study on the dynamics and control of cathode recirculation in vehicle high-power self-humidifying PEMFC system under low load conditions. First, a control-oriented dynamic model of the vehicle PEMFC system with a cathode recirculation loop is developed and the steady-state and dynamic performance is verified with experimental data from a 120 kW system. Active control of the intake component is achieved by re-feeding the reacted cathode gas to the air compressor outlet through a recirculation pump. On this basis, a high-potential controller based on oxygen partial pressure regulation is designed in combination with the dynamics of cathode recirculation. Results show that the designed dynamic fuzzy logic segmented proportional integral derivative controller with feedforward compensation achieves the optimal high-potential control effect by managing the oxygen partial pressure under variable low load conditions. It not only has excellent anti-disturbance ability but also effectively reduces the dynamic response time, transient overshoot, and steady-state error to satisfy the rapid and stable voltage output. Finally, the concomitant effect of humidification brought by the implementation of the optimal high-potential controller is analyzed, and the results show that the proton membrane is completely humidified.  相似文献   

8.
Tracking control of oxygen excess ratio (OER) is crucial for dynamic performance and operating efficiency of the proton exchange membrane fuel cell (PEMFC). OER tracking errors and overshoots under dynamic load limit the PEMFC output power performance, and also could lead oxygen starvation which seriously affect the life of PEMFC. To solve this problem, an adaptive sliding mode observer based near-optimal OER tracking control approach is proposed in this paper. According to real time load demand, a dynamic OER optimization strategy is designed to obtain an optimal OER. A nonlinear system model based near-optimal controller is designed to minimize the OER tracking error under variable operation condition of PEMFC. An adaptive sliding mode observer is utilized to estimate the uncertain parameters of the PEMFC air supply system and update parameters in near-optimal controller. The proposed control approach is implemented in OER tracking experiments based on air supply system of a 5 kW PEMFC test platform. The experiment results are analyzed and demonstrate the efficacy of the proposed control approach under load changes, external disturbances and parameter uncertainties of PEFMC system.  相似文献   

9.
The road testing and demonstration of a three-wheeler vehicle driven by a 5 kW proton exchange membrane fuel cell (PEMFC) was carried out in the absence and presence of lead acid batteries. Prior to integrating the PEMFC module and batteries in the three-wheeler, they were tested and demonstrated separately. The PEMFC module had a very fast response as the load was manually or, especially, automatically changed and it could supply a continuous power when the reactant was supplied continuously. In contrast, the 5 kW lead acid batteries alone could supply power for no longer than 300 s. In the presence of both the PEMFC module and batteries, when the drawing power was in the range of the PEMFC module capacity the propulsion motor gained its energy from the PEMFC module only, whilst the stack power output at all conditions was greater than the setting power of approximately 400 W. After integrating the PEMFC module and batteries into the three-wheeler, both energy sources were found to power the vehicle effectively. The motor power as well as the stack power changed as a linear proportion to the throttle. The motor consumed more power in case of high speed driving, take off or hill climbing, while it used only 0.354 kW in the absence of throttle. The hybrid system can achieve a maximum speed in this three-wheeler of around 24.9 km/h with a hydrogen consumption of 11 g H2/km (71 g H2/kWh) and an operating cost of 1.99 USD/km. The thermodynamic efficiency of the vehicle was 42.9%.  相似文献   

10.
Aiming at the power fluctuation and mismatch of the combined cooling, heating, and power (CCHP) system based on proton exchange membrane fuel cells (PEMFCs) and adsorption chiller, this study proposes a multi-stack coupled power supply strategy. The PEMFC stacks are divided into types Ⅰ, Ⅱ, and Ⅲ to meet the electric load and cooling load of the data center, and the heat requirements of the system. Meanwhile, economic analysis is conducted on the single-stack energy supply strategy and the multi-stack coupled energy supply strategy. The results show that with the multi-stack coupling power supply strategy, the cooling power and electric power almost completely match the load of the data center, without power fluctuations and overshoot. By smoothing the PID control results of the current of the stacks-Ⅲ, the heating power fluctuation is significantly reduced, and the maximum overshoot does not exceed 0.5 kW. Therefore, the strategy is conducive to the stable operation of the PEMFC stack and improves the lifetime of the system. Considering investment costs, maintenance costs, hydrogen costs, and electricity benefits, the multi-stack coupled energy supply strategy can save about 6.1 × 105 $ per year. In summary, the multi-stack coupled energy supply strategy has advantages in system lifetime, operational stability, and economy.  相似文献   

11.
A hybrid system combining a 2 kW air-blowing proton exchange membrane fuel cell (PEMFC) stack and a lead–acid battery pack is developed for a lightweight cruising vehicle. The dynamic performances of this PEMFC system with and without the assistance of the batteries are systematically investigated in a series of laboratory and road tests. The stack current and voltage have timely dynamic responses to the load variations. Particularly, the current overshoot and voltage undershoot both happen during the step-up load tests. These phenomena are closely related to the charge double-layer effect and the mass transfer mechanisms such as the water and gas transport and distribution in the fuel cell. When the external load is beyond the range of the fuel cell system, the battery immediately participates in power output with a higher transient discharging current especially in the accelerating and climbing processes. The DC–DC converter exhibits a satisfying performance in adaptive modulation. It helps rectify the voltage output in a rigid manner and prevent the fuel cell system from being overloaded. The dynamic responses of other operating parameters such as the anodic operating pressure and the inlet and outlet temperatures are also investigated. The results show that such a hybrid system is able to dynamically satisfy the vehicular power demand.  相似文献   

12.
13.
This paper develops robust control and power management strategies for a 6 kW stationary proton exchange membrane fuel cell (PEMFC) hybrid power system. The system consists of two 3 kW PEMFC modules, a Li–Fe battery set, and electrical components to form a parallel hybrid power system that is designed to supply uninterruptible power to telecom base stations during power outages. The study comprises three parts: PEMFC control, power management, and system integration. First, we apply robust control to regulate the hydrogen flow rates of the PEMFC modules in order to improve system stability, performance, and efficiency. Second, we design a parallel power train that consists of two PEMFC modules and one Li–Fe battery set for the uninterruptible power supply (UPS) requirement. Lastly, we integrate the system for experimental verification. Based on the results, the proposed robust control and power management are deemed effective at improving the stability, performance, and efficiency of the stationary power system.  相似文献   

14.
15.
This paper investigates the issue of performance optimization for proton exchange membrane fuel cell (PEMFC) system. In PEMFC system, the system efficiency is the key parameters to evaluate the system performance which is sensitive to the air flow rate. Thus, the careful selection of the air flow rate is crucial to ensure efficient, reliable and durable operation of the PEMFC system. In this paper, the dynamic response of the system under variable air flow rate is studied in detail by means of experiments on the built 5 kW PEMFC system with 110 cells and a catalyst active area of 250 cm2. The oxygen excess ratio (OER) is defined to indicate the state of oxygen supply. The experimental results show that the maximum efficiency is existed under certain net current. The OER conditions have the optimal characteristic for system efficiency. Through the optimization of system performance, the system efficiency can be increased by 12.2% on average. At the same time, the system dynamic characteristic under oxygen starvation and oxygen saturation are analyzed in detail based on the experimental data.  相似文献   

16.
The present work describes the experimental characterisation of a self-humidified 1 kW PEM fuel stack with 24 cells. A test bench was prepared and used to operate a PEMFC stack, and several parameters, such as the temperature, pressure, stoichiometry, current and voltage of each cell, were monitored with a LabView platform to obtain a complete thermal and electrical characterisation. The stack was operated in the constant resistance load regime, in dead-end mode (with periodic releases of hydrogen), with 30% relative humidity air and with temperature control from a cooling water circuit. The need to operate the stack for significant periods of time to achieve repeatable performance behaviour was observed, as was the advantage of using some recuperation techniques to improve electrical energy production. At low temperatures, the individual cell voltage measurements show lower values for the cells nearer to the cooling channels. The performance of the fuel cell stack decreases at operating temperatures above 40 °C. The stack showed the best performance and stability at 30 °C, with 300 mbar of hydrogen and 500 mbar of air pressure. The optimised hydrogen purge interval was 15 s, and the most favourable air stoichiometry was 2. Between 15 A and 32 A, the maximum electrical efficiency was 40%, and the thermal energy recovery in the cooling system was 40.8%; these values are based on the HHV. Electrical efficiencies above 40% were obtained between 10 and 55 A. The variation in the electrical efficiency is explained by the variation in the following independently measured factors: the fuel utilisation coefficient and the faradic and voltage efficiencies. The deviation between the product of the factors and the measured electrical efficiency is below 0.5%. Measurements were taken to identify all the losses from the fuel cell stack; namely, the energy balance to the cooling water, which is the main portion. The other quantified losses by order of importance are the purged hydrogen and the latent and sensible heat losses from the cathode exhaust. The heat losses to the environment were also estimated based on the measured stack surface temperature. The sum of all the losses and the electrical output has a closure error below 2% except at the highest and lowest loads.  相似文献   

17.
The proton exchange membrane (PEM) fuel cell (PEMFC) is equipped with a series of auxiliary components which consume considerable amount of energy. It is necessary to investigate the design and operation of the PEMFC power system for better system performance. In this study, a typical PEMFC power system is developed, and a thermodynamic model of the system is established. Simulation is carried out, and the power distribution of each auxiliary component in the system, the net power and power efficiency of the system are obtained. This power system uses cooling water for preheating inlet gases, and its energy-saving effect is also verified by the simulation. On this basis, the exergy analysis is applied on the system, and the indexes of the system exergy loss, exergy efficiency and ecological function are proposed to evaluate the system performance. The results show that fuel cell stack and heat exchanger are the two components that cause the most exergy loss. Furthermore, the system performance under various stack inlet temperatures and current densities is also analyzed. It is found that the net power, energy efficiency and exergy efficiency of the system reach the maximum when the stack inlet temperature is about 348.15 K. The ecological function is maintained at a high level when the stack inlet temperature is around 338.15 K. Lower current density increases the system ecological function and the power and exergy efficiencies, and also helps decrease the system exergy loss, but it decreases the system net power.  相似文献   

18.
The durability of metal plate proton exchange membrane fuel cell (PEMFC) stack is still an important factor that hinders its large-scale commercial application. In this paper, we have conducted a 1000 h durability test on a 1 kW metal plate PEMFC stack, and explored the degradation of the core components. After 1000 h of dynamic load cycles, the voltage decay percentage of the stack under the current densities of 1000 mA cm?2 is 5.67%. By analyzing the scanning electron microscopy (SEM) images, the surfaces of the metal plates are contaminated locally by organic matter precipitated from the membrane electrode assembly (MEA). The SEM images of the catalyst coated membrane (CCM) cross section indicate that the MEA has undergone severe degradation, including the agglomeration of the catalyst layer, and the thinning and perforation of the PEM. These are the main factors that cause the rapid increase in hydrogen crossover flow rate and performance decay of the PEMFC stack.  相似文献   

19.
石磊  许思传  刘泽 《太阳能学报》2022,43(8):498-503
电堆工作过程中各个单体电压的一致性是提高其性能的关键,在3 kW电堆台架实验数据的基础上,利用人工神经网络(ANN)模型,对空气流量、氢气压力、过量空气系数等气体供给参数进行优化,并对优化前后电堆的功率特性、一致性特性进行对比分析。结果表明:当氢气入口压力为0.128 MPa、空气入口流量为11 g/s、过量空气系数为6.4时,电堆电压差异系数CV及功率参数可达到最佳。  相似文献   

20.
This paper presents a novel planar proton exchange membrane fuel cell (PEMFC) stack designed for portable electronic devices, consisting of twenty homemade membrane electrode assemblies (MEAs) arranged on a planar surface and three printed circuit boards (PCBs, including anode, interlayer and cathode PCBs) used to load these MEAs. The current collectors and electrical connectors are manufactured using printed circuit technology. The inlet holes of reaction gases are also machined on PCB substrates. The output performance tests are performed on the MEAs and the assembled planar PEMFC stack. The results show that the power densities of the MEAs and the planar PEMFC stack are 0.6 W/cm2 and 0.361 W/cm2 at rated voltage under ambient temperature and forced convection air conditions, respectively. The stability tests are also conducted on the planar PEMFC stack, and the results show no significant fluctuations in output current. The feasibility of the application of planar PEMFC stacks in portable electronic devices is preliminarily demonstrated, and the improvement directions for further improving the output performance are proposed accordingly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号