首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This article is a careful examination of an energy poly-generation unit integrated with an evacuated solar thermal tube collector. A proton exchange membrane (PEM) electrolysis unit is used for hydrogen production, an ejector refrigeration system (ERS) is utilized for cooling demand, and a heater unit is used for heating demand. All sub-systems are validated by considering recent articles. Cooling and heating demand, as well as the net output power are calculated. The modeled poly-generation system's exergy and energy efficiency are maximized by considering the inlet temperature of the heat exchanger and primary pressure of the ejector with the parametric evaluation of the system. The proposed poly-generation set-up can produce cooling load, heating load, and hydrogen with amounts of 5.34 kW, 5.152 kW, and 63 kg/year, respectively. Based on these values, the energy ef?ciency, and exergy ef?ciency are computed to be 64.14%, and 49.62%, respectively. Higher energy and exergy ef?ciencies are obtained by reducing high pressure of the refrigeration cycle or decreasing the temperature outlet of an auxiliary heater. The heat exchanger and thermal energy storage unit have the highest cost rate among all system components with 73,463 $ and 46,357, respectively. Parametric study indicates that the main determinative elements in the total cost rate of the system are the heater, and the solar collector.  相似文献   

2.
In this study, exergoeconomic and environmental impact analyses, through energy, exergy, and sustainability assessment methods, are performed to investigate a hybrid version renewable energy (including wind and solar) based hydrogen and electricity production system. The dead state temperatures considered here are 10 °C, 20 °C and 30 °C to undertake a parametric study. An electrolyzer and a metal hydride tank are used for hydrogen production and hydrogen storage, respectively. Also, the Proton Exchange Membrane Fuel Cell (PEMFC) and battery options are utilized for electricity generation and storage, respectively. As a result, the energy and exergy efficiencies and the sustainability index for the wind turbine are found to be higher than the ones for solar photovoltaic (PV) system. Also, the overall exergy efficiency of the system is found to be higher than the corresponding overall energy efficiency. Furthermore, for this system, it can be concluded that wind turbine with 60 gCO2/month is more environmentally-benign than the solar PV system with 75 gCO2/month. Finally, the total exergoeconomic parameter is found to be 0.26 W/$, when the energy loss is considered, while it is 0.41 W/$, when the total of exergy loss and destruction rates are taken into account.  相似文献   

3.
Renewable energy based multi-generation systems can help solving energy-related environmental problems. For this purpose, a novel solar tower-based multi-generation system is proposed for the green hydrogen production as the main product. A solar-driven open Brayton cycle with intercooling, regeneration and reheat is coupled with a regenerative Rankine cycle and a Kalina cycle-11 as a unique series of power cycles. Significant portion of the produced electricity is utilized to produce green hydrogen in an electrolyzer. A thermal energy storage, a single-effect absorption refrigeration cycle and two domestic hot water heaters are also integrated. Energy, exergy and economic analyses are performed to examine the performance of the proposed system, and a detailed parametric analysis is conducted. Multiobjective optimization is carried out to determine the optimum performance. Optimum energy and exergy efficiencies, unit exergy product cost and total cost rate are calculated as 39.81%, 34.44%, 0.0798 $/kWh and 182.16 $/h, respectively. Products are 22.48 kg/h hydrogen, 1478 kW power, 225.5 kW cooling and 7.63 kg/s domestic hot water. Electrolyzer power size is found as one of the most critical decision variables. Solar subsystem has the largest exergy destruction. Regenerative Rankine cycle operates at the highest energy and exergy efficiencies among power cycles.  相似文献   

4.
This paper investigates the performance of a hydrogen refueling system that consists of a polymer electrolyte membrane electrolyzer integrated with photovoltaic arrays, and an electrochemical compressor to increase the hydrogen pressure. The energetic and exergetic performance of the hydrogen refueling station is analyzed at different working conditions. The exergy cost of hydrogen production is studied in three different case scenarios; that consist of i) off-grid station with the photovoltaic system and a battery bank to supply the required electric power, ii) on-grid station but the required power is supplied by the electric grid only when solar energy is not available and iii) on-grid station without energy storage. The efficiency of the station significantly increases when the electric grid empowers the system. The maximum energy and exergy efficiencies of the photovoltaic system at solar irradiation of 850 W m-2 are 13.57% and 14.51%, respectively. The exergy cost of hydrogen production in the on-grid station with energy storage is almost 30% higher than the off-grid station. Moreover, the exergy cost of hydrogen in the on-grid station without energy storage is almost 4 times higher than the off-grid station and the energy and exergy efficiencies are considerably higher.  相似文献   

5.
Solar thermochemical hydrogen production with energy level upgraded from solar thermal to chemical energy shows great potential. By integrating mid-and-low temperature solar thermochemistry and solid oxide fuel cells, in this paper, a new distributed energy system combining power, cooling, and heating is proposed and analyzed from thermodynamic, energy and exergy viewpoints. Different from the high temperature solar thermochemistry (above 1073.15 K), the mid-and-low temperature solar thermochemistry utilizes concentrated solar thermal (473.15–573.15 K) to drive methanol decomposition reaction, reducing irreversible heat collection loss. The produced hydrogen-rich fuel is converted into power through solid oxide fuel cells and micro gas turbines successively, realizing the cascaded utilization of fuel and solar energy. Numerical simulation is conducted to investigate the system thermodynamic performances under design and off-design conditions. Promising results reveal that solar-to-hydrogen and net solar-to-electricity efficiencies reach 66.26% and 40.93%, respectively. With the solar thermochemical conversion and hydrogen-rich fuel cascade utilization, the system exergy and overall energy efficiencies reach 59.76% and 80.74%, respectively. This research may provide a pathway for efficient hydrogen-rich fuel production and power generation.  相似文献   

6.
With the continuous penetration of renewable energy plants into energy markets and their surplus power generation during off-peak periods, the need for utility-scale energy storage technologies is globally prioritized. Among the existing large-scale energy storage technologies, hydrogen storage has appeared as a powerful alternative due to its environmental benefits and the ability to store a large amount of energy for several hours to months. The major objective of the proposed research is to introduce a novel configuration of green hydrogen production for power generation during peak demand periods. In this regard, an innovative hybridization of a solar unit based on a parabolic trough collector with a proton-exchange membrane electrolyzer and a fuel cell is introduced and analyzed from the thermodynamic and exergoeconomic perspectives. Moreover, a sensitivity analysis and a multi-objective optimization based on the combination of neural network and grey wolf optimization algorithms are conducted to select the best working fluid of the solar unit and ideal operating conditions according to the minimum cost rate and the maximum exergy efficiency. The results indicate that Dowtherm? A synthetic oil is the best working fluid, and the proposed system can generate 9, 14.9, and 20.1 MW of power during off-, mid-, and on-peak times, respectively. The results also show that the proposed system operates with an exergy efficiency of 17.6% and a cost rate of 492.4 $/hr under the optimal conditions.  相似文献   

7.
This paper investigates the performance of a high temperature Polymer Electrolyte Membrane (PEM) electrolyzer integrated with concentrating solar power (CSP) plant and thermal energy storage (TES) to produce hydrogen and electricity, concurrently. A finite-time-thermodynamic analysis is conducted to evaluate the performance of a PEM system integrated with a Rankine cycle based on the concept of exergy. The effects of solar intensity, electrolyzer current density and working temperature on the performance of the overall system are identified. A TES subsystem is utilized to facilitate continuous generation of hydrogen and electricity. The hydrogen and electricity generation efficiency and the exergy efficiency of the integrated system are 20.1% and 41.25%, respectively. When TES system supplies the required energy, the overall energy and exergy efficiencies decrease to 23.1% and 45%, respectively. The integration of PEM electrolyzer enhances the exergy efficiency of the Rankine cycle, considerably. However, it causes almost 5% exergy destruction in the integrated system due to conversion of electrical energy to hydrogen energy. Also, it is concluded that increase of working pressure and membrane thickness leads to higher cell voltage and lower electrolyzer efficiency. The results indicate that the integrated system is a promising technology to enhance the performance of concentrating solar power plants.  相似文献   

8.
In this study, a solar and wind energy-based system integrated with H2O2 combustor is developed to produce fresh water from sea-water desalination, electricity, cooling, hydrogen, and oxygen as well as to provide food drying and domestic water heating. The main components of the proposed system contains concentrated solar power (CSP), wind turbine, Rankine cycle, multi stage flash (MSF) desalination unit, water electrolyzer, a refrigeration unit, a food drying system, oxy-hydrogen combustor, domestic water heater, as well as hydrogen and oxygen storage units. Furthermore, for continuous operation of the system during night time and in cloudy weather conditions, a thermal energy storage (TES) unit and oxy-hydrogen combustion unit are integrated to the system. Based on energy and exergy balances, performance assessment of the proposed system is conducted. Moreover, effects of various parameters such as solar irradiation, wind speed and ambient temperature on some of the outputs of the system are investigated. The results illustrate that the proposed system fulfills most of the remote community requirements in an efficient, environmentally benign and uninterrupted way. The obtained results for the reference case show that with installation of parabolic trough concentrators (PTCs) on an area of 111,728 m2, the plant produces net electrical power of approximately 11.4 MW, approximately 828 m3/day of freshwater, about 36 kg/s of hot air for food drying, about 31 kg/s of heated domestic water, approximately 920 kg/day of H2 and about 2.26 MW of cooling. The overall energy efficiency of the system is found to be 50%, while the exergy efficiency of the system is 34%. In addition, the energy and exergy efficiencies of single generation in which there is only electrical power output are approximately 15% and 16%, respectively.  相似文献   

9.
In this study, thermodynamic analysis of solar-based hydrogen production via copper-chlorine (Cu–Cl) thermochemical water splitting cycle is presented. The integrated system utilizes air as the heat transfer fluid of a cavity-pressurized solar power tower to supply heat to the Cu–Cl cycle reactors and heat exchangers. To achieve continuous operation of the system, phase change material based on eutectic fluoride salt is used as the thermal energy storage medium. A heat recovery system is also proposed to use the potential waste heat of the Cu–Cl cycle to produce electricity and steam. The system components are investigated thoroughly and system hotspots, exergy destructions and overall system performance are evaluated. The effects of varying major input parameters on the overall system performance are also investigated. For the baseline, the integrated system produces 343.01 kg/h of hydrogen, 41.68 MW of electricity and 11.39 kg/s of steam. Overall system energy and exergy efficiencies are 45.07% and 49.04%, respectively. Using Genetic Algorithm (GA), an optimization is performed to evaluate the maximum amount of produced hydrogen. The optimization results show that by selecting appropriate input parameters, hydrogen production rate of 491.26 kg/h is achieved.  相似文献   

10.
In front of the opportunity of the rapid development of renewable energy power generation, energy storage is playing a more important role in improving its utilization efficiency. In this paper, a hybrid energy system based on combination of hydrogen fueled compressed air energy storage system and water electrolysis hydrogen generator is proposed. The superfluous renewable energy power is charged by compressing the air and/or producing hydrogen through water electrolysis. A hydrogen combustor is introduced to raise the air temperature in the discharging process. A thermodynamic model of the proposed system is built. Energy and exergy analysis found that under the design condition, the proposed system can achieve a round trip efficiency of 65.11%, an exergy efficiency of 79.23%, and an energy storage density of 5.85 kWh/m3. The exergy loss of water electrolysis hydrogen generator and hydrogen combustor rank in the top two of all components. Sensitivity analysis indicates that the outlet temperature of hydrogen combustor and specific energy consumption of water electrolysis hydrogen generator are the crucial influencing factor of system performance.  相似文献   

11.
It is a promising method for hydrogen generation without carbon emitting by ammonia decomposition in a catalytic palladium membrane reactor driven by solar energy, which could also store and convert solar energy into chemical energy. In this study, kinetic and thermodynamic analyses of mid/low-temperature solar thermochemical ammonia decomposition for hydrogen generation in membrane reactor are conducted. Hydrogen permeation membrane reactor can separate the product and shift the reaction equilibrium forward for high conversion rate in a single step. The variation of conversion rate and thermodynamic efficiency with different characteristic parameters, such as reaction temperature (100–300 °C), tube length, and separation pressure (0.01–0.25 bar), are studied and analyzed. A near-complete conversion of ammonia decomposition is theoretically researched. The first-law thermodynamic efficiency, net solar-to-fuel efficiency, and exergy efficiency can reach as high as 86.86%, 40.08%, and 72.07%, respectively. The results of this study show the feasibility of integrating ammonia decomposition for hydrogen generation with mid/low-temperature solar thermal technologies.  相似文献   

12.
In this study, the iron-based chemical looping process driven by various biomasses for hydrogen production purposes is studied and evaluated thermodynamically through energy and exergy approaches. The overall system consists of some key units (combustor, reducers and oxidizer) a torrefier, a drying chamber, an air separation unit, a heat exchanger, and auxiliary units as well. The biomasses considered are first dried and torrified in the drying chamber and sent to reactors to produce hydrogen. The exergy and energy efficiencies of the iron based chemical looping facility are investigated comparatively for performance evaluation. The maximum exergy destruction and entropy production rates are calculated for the torrefaction process as 123.15 MW and 4926 kW/K respectively. Under the steady–state conditions, a total of 8 kg/s hydrogen is produced via chemical looping process. The highest energy efficiency is obtained in the looping of rice husk with 86% while the highest exergy efficiency is obtained in the looping using sugarcane bagasse with 91%, respectively.  相似文献   

13.
Thermal management of metal hydride (MH) hydrogen storage systems is critically important to maintain the hydrogen absorption and release rates at desired levels. Implementing thermal management arrangements introduces challenges at system level mostly related to system's overall mass, volume, energy efficiency, complexity and maintenance, long-term durability, and cost. Low effective thermal conductivity (ETC) of the MH bed (~0.1–0.3 W/mK) is a well-known challenge for effective implementation of different thermal management techniques. This paper comprehensively reviews thermal management solutions for the MH hydrogen storage used in fuel cell systems by also focusing on heat transfer enhancement techniques and assessment of heat sources used for this purpose. The literature recommended that the ETC of the MH bed should be greater than 2 W/mK, and heat transfer coefficient with heating/cooling media should be in the range of 1000–1200 W/m2K to achieve desired MH's performance. Furthermore, alternative heat sources such as fuel cell heat recovery or capturing MH heat during charging and releasing it back during discharging have also been thoroughly reviewed here. Finally, this review paper highlights the gaps and suggests directions accordingly for future research on thermal management for MH systems.  相似文献   

14.
The study aims to optimize the geothermal and solar-assisted sustainable energy and hydrogen production system by considering the genetic algorithm. The study will be useful by integrating hydrogen as an energy storage unit to bring sustainability to smart grid systems. Using the Artificial Neural Network (ANN) based Genetic Algorithm (GA) optimization technique in the study will ensure that the system is constantly studied in the most suitable under different climatic and operating conditions, including unit product cost and the plant's power output. The water temperature of the Afyon Geothermal Power Plant varies between 70 and 130 °C, and its mass flow rate varies between 70 and 150 kg/s. In addition, the solar radiation varies between 300 and 1000 W/m2 for different periods. The net power generated from the region's geothermal and solar energy-supported system is calculated as 2900 kW. If all of this produced power is used for hydrogen production in the electrolysis unit, 0.0185 kg/s hydrogen can be produced. The results indicated that the overall energy and exergy efficiencies of the integrated system are 4.97% and 16.0%, respectively. The cost of electricity generated in the combined geothermal and solar power plant is 0.027 $/kWh if the electricity is directly supplied to the grid and used. The optimized cost of hydrogen produced using the electricity produced in geothermal and solar power plants in the electrolysis unit is calculated as 1.576 $/kg H2. The optimized unit cost of electricity produced due to hydrogen in the fuel cell is calculated as 0.091 $/kWh.  相似文献   

15.
Renewable energy-based hydrogen production plants can offer potential solutions to both ensuring sustainability in energy generation systems and designing environmentally friendly systems. In this combined work, a novel solar energy supported plant is proposed that can generate hydrogen, electricity, heating, cooling and hot water. With the suggested integrated plant, the potential of solar energy usage is increased for energy generation systems. The modeled integrated system generally consists of the solar power cycle, solid oxide fuel cell plant, gas turbine process, supercritical power plant, organic Rankine cycle, cooling cycle, hydrogen production and liquefaction plant, and hot water production sub-system. To conduct a comprehensive thermodynamic performance analysis of the suggested plant, the combined plant is modeled according to thermodynamic equilibrium equations. A performance assessment is also conducted to evaluate the impact of several plant indicators on performance characteristics of integrated system and its sub-parts. Hydrogen production rate in the suggested plant according to the performance analysis performed is realized as 0.0642 kg/s. While maximum exergy destruction rate is seen in the solar power plant with 8279 kW, the cooling plant has the lowest exergy destruction rate as 1098 kW. Also, the highest power generation is obtained from gas turbine cycle with 7053 kW. In addition, energetic and exergetic efficiencies of solar power based combined cycle are found as 56.48% and 54.06%, respectively.  相似文献   

16.
In this work, a unified renewable energy system has designed to assess the electricity and hydrogen production. This system consists of the evacuated tube solar collectors (ETSCs) which have the total surface area of 300 m2, a salt gradient solar pond (SGSP) which has the surface area of 217 m2, an Organic Rankine Cycle (ORC) and an electrolysis system. The stored heat in the heat storage zone (HSZ) transferred to the input water of the ETSCs by means of an exchanger and thereby ETSCs increase the temperature of preheated water to higher level as much as possible that primarily affects the performance of the ORC. The balance equations of the designed system were written and analyzed by utilizing the Engineering Equations Solver (EES) software. Hence, the energy and exergy efficiencies of the overall system were calculated as to be 5.92% and 18.21%, respectively. It was also found that hydrogen generation of the system can reach up to ratio 3204 g/day.  相似文献   

17.
This study proposes a combined hydrogen, heating and power system based on solar energy for the off-grid application of distributed renewable energy. With hydrogen as the energy carrier, the stable consumption of renewable energy can be achieved by integrating alkaline water electrolysis (AWE), metal hydride (MH) hydrogen storage, and proton exchange membrane fuel cells (PEMFCs). An energy management strategy is proposed based on the coordinated control of mass, energy, and information flow. Fluctuations in multi-source heat flow during solar photovoltaic (PV) power generation, hydrogen production, hydrogen-storage, and PEMFC power generation were studied based on electric and heating loads of typical winter and summer days in an eco-neighborhood in Ningbo, China. Owing to differences in solar radiation between summer and winter, the total electric energy generated by PV panels was 6179 kWh and 3667 kWh for summer and winter, respectively. The start-up times for AWE and MHs were 0.92 h and 0.32 h in summer and 1.70 h and 0.55 h in winter, respectively. After one day of operation, the hydrogen and heat surpluses were 57.17 kg and 5735.83 MJ in summer, while in winter the hydrogen surplus and heat deficit were 30.87 kg and 226.41 MJ, respectively.  相似文献   

18.
In today, the basic necessity for the economic and social development of countries is to have a cheap, reliable, sustainable, and environmentally friendly energy source. For this reason, renewable energy sources stand out as the most important key. Solar energy-based multi-energy generation systems are one of the most important options among the current scenarios to prevent global warming. In this presented study, electricity and hydrogen production from a solar collector with medium temperature density is investigated. In this system, 34 pipes evacuated tube solar collector (ETSC) is used for thermal energy generation, organic Rankine cycle (ORC) for electricity generation, and Proton exchanger membrane electrolyzer (PEMe) for hydrogen production. In addition, the energy and exergy efficiencies of the whole system calculated as 51.82% and 16.30%, respectively. Moreover, the amount of hydrogen obtained in PEM is measured as 0.00527 kg/s.  相似文献   

19.
An integrated hydrogen and power co-generation system based on slurry-feed coal gasification and chemical looping hydrogen generation (CLH) was proposed with Shenhua coal as fuel and Fe2O3/MgAl2O4 as an oxygen carrier. The sensitivity analyses of the main units of the system were carried out respectively to optimize the parameters. The syngas can be converted completely in the fuel reactor, and both of the fuel reactor and steam reactor can maintain heat balance. The purity of hydrogen produced after water condensation is 100%. The energy and exergy analyses of the proposed system were studied. Pinch technology was adopted to get a reasonable design of the heat transfer network, and it is found pinch point appears at the hot side temperature of 224.7 °C. At the given status of the proposed system, the hydrogen yield is 1040.11 kg·h−1 and the CO2 capture rate is 94.56%. At the same time, its energy and exergy efficiencies are 46.21% and 47.22%, respectively. According to exergy analysis, the degree of exergy destruction is ranked. The gasifier unit has the most serious exergy destruction, followed by chemical looping hydrogen generation unit and the heat recovery steam generator unit.  相似文献   

20.
A proposed hybrid solar hydrogen system with activated carbon storage for residential power generation is assessed using exergy analysis. Energy and exergy balances are applied to determine exergy flows and efficiencies for individual devices and the overall system. A ‘base case’ analysis considers the proposed system without modification, while a ‘modified case’ extends the base case by considering the possibility of multiple product outputs. It is determined that solar photovoltaic-based sub-systems have the lowest exergy efficiencies (14-18%) and offer the most potential for improvement. A comparison of these two scenarios shows that the additional outputs raise the exergy efficiency of the modified case (11%) relative to the base case (4.0%). An investigation of the energy and exergy efficiencies of separate devices illustrates how energy analyses can be misleading. The hybrid system is expected to have several environmental benefits, which may offset to some degree economic barriers to implementation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号