1.
裂化催化剂生产过程中产生的高盐度、高浊度、高氨氮、低C/N比废水难以处理。构建了电絮凝-半短程硝化-厌氧氨氧化组合工艺,考察了该组合工艺对实际裂化催化剂废水的处理效果以及处理稳定性。结果表明组合工艺处理裂化催化剂废水具有较好的稳定性,出水水质稳定在以下水平:浊度< 30 NTU,NH4+-N< 10 mg·L-1,NO2--N< 3 mg·L-1, NO3-< 40 mg·L-1,COD< 100 mg·L-1;通过进水氨氮浓度确定曝气时间的方式可以保证长期稳定的半短程硝化过程,出水NO2-/NH4+-N比值维持在0.9~1.4之间,满足厌氧氨氧化反应器的进水要求;同时在裂化催化剂废水的高盐度胁迫下厌氧氨氧化工艺能够表现出显著的厌氧氨氧化效果。  相似文献   

2.
采用稳定运行的环状生物膜反应器(bio-films annular reactor,BAR)模拟原水长距离输水管道水质净化过程,以不同投氯方式进行预氯化对原水输水管道硝化性能的破坏与恢复试验研究。结果表明,预氯化对管道生物膜AOB损伤较大,灭活率为4.96log,对NH4+-N、NO2--N去除效能影响明显。恢复阶段CT值越高生物膜中AOB恢复生长速率越快。生物膜对NH4+-N去除效能的恢复较NO2--N快2 d,NH4+-N、NO2--N分别在第8 d和第10 d完成恢复。生膜中AOB数量的恢复与管道对NH4+-N的去除率之间存在明显的相关性,其相关系数可达到92%。  相似文献   

3.
为保证长距离输水管道输送水水质,采用管道模拟反应器考察了溶解氧(DO)对输水管道水质影响以及曝气充氧后水质恢复情况。结果表明:DO降低影响氨氮(NH+4-N)的去除,DO浓度越低越不利于NH+4-N的去除,且曝气充氧后恢复越缓慢,DO=0.5 mg·L-1和DO=1.5 mg·L-1的反应器在运行95 h后,NH+4-N去除率分别由90%降到21%和85%,曝气充氧54 h和3 h后恢复;DO浓度降低导致亚硝酸氮(NO-2-N)积累明显增加,DO浓度越低,NO-2-N的积累越严重,且曝气充氧后恢复越缓慢,DO=0.5 mg·L-1的反应器在运行95 h后,出水NO-2-N由0.02 mg·L-1增加到0.354 mg·L-1,曝气充氧54 h后恢复,DO=1.5 mg·L-1的反应器在运行32 h后,出水NO-2-N达到最大值0.112 mg·L-1,曝气充氧4 h后恢复;DO浓度降低使水中UV254升高,DO=0.5 mg·L-1和DO=1.5mg·L-1的反应器在运行2 h后,出水UV254分别增加了70.8%和20.8%,均在运行32 h后恢复,且曝气充氧后保持稳定。因此,DO对长距离输水管道水质具有重要影响,可采用DO实现对水质的调控。  相似文献   

4.
长泥龄改良A2/O工艺的短程硝化反硝化除磷   总被引:1,自引:0,他引:1       下载免费PDF全文
罗亚红  李冬  鲍林林  许达  蔡言安  张杰 《化工学报》2014,65(12):4985-4996
为解决传统A2/O工艺硝化与除磷泥龄(SRT)之间的矛盾,进一步提高低C/N(P)比生活污水同步脱氮除磷效率,采用一种改良A2/O工艺在长SRT条件下处理生活污水.试验结果表明,该工艺可有效筛选和强化反应器内活性污泥,并大量富集长SRT的反硝化除磷菌(DPAO).通过亚硝酸盐氧化菌(NOB)淘洗阶段后,反应器在SRT=19.6d、A2O段污泥浓度(MLSS)=5.5 g·L-1、水力停留时间(HRT)=8.2 h、污泥回流比(R)=90%、硝化液回流比(r)=250%、溶解氧(DO)=1.5~0.3 mg·L-1,间歇曝气段HRT=4 h、曝气周期1 h曝气1 min(DO=0.3~0.5 mg·L-1)、沉淀59 min条件下长期运行,COD、NH4+-N、TP和TN的平均去除率分别为88.71%、99.2%、93.77%和89.52%,出水亚硝化率(NO2--N/NOx--N)可达97.2%,DPAO占聚磷菌(PAO)比为95.5%.污水中约72.96%的COD被DPAO合成PHA除磷,15.75%的COD由异养反硝化消耗,约41.96%和31.31%的N分别通过反硝化除磷和异养反硝化去除.剩余污泥主要由DPAO和反硝化菌增殖产生,分别占82.74%和17.24%,较传统脱氮除磷途径减少了58.76%的碳源消耗和44.6%的污泥排放.  相似文献   

5.
生物转鼓反应器氧转移特性及运行效能   总被引:1,自引:1,他引:0       下载免费PDF全文
李宁  苗志加  李再兴  王忠东  秦学  黄娟 《化工学报》2015,66(7):2678-2685
采用一种研制的新型生物转鼓反应器(RDBC),内部装填MBBR悬浮填料,通过调节浸没深度和转速可实现厌氧、缺氧、好氧等工况条件下运行,其氧总体积传质系数KLa可达25.87 h-1,动力效率可达228.62g·(kW·h)-1。利用生物转鼓分段进水后置反硝化工艺处理模拟生活污水,结果表明:在进水流量6 L·h-1(HRT 18 h),好氧生物转鼓反应器浸没高度比2/3、转速8 r·min-1、DO 3.0 mg·L-1,缺氧生物转鼓反应器浸没高度比5/6、转速4 r·min-1、DO 1.0 mg·L-1,进水流量分配比3:1,进水COD、NH4+-N和TN浓度平均值分别为385.0、38.0和38.0 mg·L-1时,COD、NH4+-N和TN去除率分别达到90.4%、93.7%和80.9%,出水水质可满足我国《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A排放标准要求。  相似文献   

6.
张建华  彭永臻  张淼  王淑莹  王聪 《化工学报》2015,66(12):5045-5053
以A2/O-生物接触氧化(biological contact oxidation,BCO)系统反硝化除磷活性污泥为研究对象,通过投加不同浓度的NO2--N和NO3--N(30 mg·L-1),考察了反硝化聚磷菌(denitrifying polyphosphate accumulating organisms,DPAOs)在不同电子受体配比(NO2--N:NO3--N0, 0.2:0.8, 0.4:0.6, 0.5:0.5, 0.6:0.4)条件下的脱氮除磷特性。结果表明:乙酸钠为DPAOs用于反硝化除磷的理想碳源,且其浓度为200 mg·L-1时最佳;仅以NO3--N为电子受体进行缺氧吸磷反应时,NO3--N的投加量为30 mg·L-1时较为合适;以NO2--N作为电子受体,未经 驯化的DPAOs,短时间内很难利用NO2--N,但低浓度的 (6 mg·L-1)不会影响DPAOs以 作电子受体进行反硝化除磷;同时,NO2--N对于DPAOs吸磷作用的抑制程度明显强于 反硝化作用,当NO2--N浓度达到18 mg·L-1时,吸磷反应基本停止;此外,较高浓度的NO2--N不仅会抑制聚羟基脂肪酸酯(poly-β-hydroxyalkanoate,PHA)的分解利用,且会使PHA分解产生的能量较多地用于储存糖原(glycogen,Gly),而所分解利用的PHA中90%以上为聚-β-羟基丁酸酯(poly-β-hydroxybutyrate,PHB)。  相似文献   

7.
唐晓雪  马斌  徐竹兵  彭永臻 《化工学报》2012,63(11):3666-3672
为了实现城市污水处理过程中的节能降耗,提出了三段式城市污水自养脱氮工艺,阐述了除有机物SBR在整套工艺中的重要地位,探讨了不同曝气量与污泥浓度条件下,除有机物SBR中有机物的去除特征与规律。结果表明,在不同的曝气量及污泥浓度条件下,COD降解结束前NO2--N与NO3--N的浓度均低于0.1 mg·L-1,反应器进入COD难降解阶段后,NO2--N与NO3--N的浓度快速提高,可以认为在除有机物SBR内有机物的去除和硝化过程是分步进行的,即先进行有机物的去除,而后进行硝化过程。DO曲线与pH曲线的突越点与除有机物过程的终点始终保持一致,可将其作为实时控制参数监测有机物的去除终点,对好氧曝气过程进行实时控制。  相似文献   

8.
微生物法处理空间站废水是未来空间站水回收管理系统的发展方向之一,为了探究生化法对空间站废水的处理效果,设计并搭建了一套MABR反应器,以出水COD、NH4+-N和TN等作为主要考察指标,并结合NO2--N、NO3--N等指标对反应器的处理效果进行评估和分析。试验对比了不同曝气压力、不同断面流速下反应器的处理效能,从而找出各因素对反应器处理效果的影响规律,然后在一定条件对空间站模拟废水进行处理。结果表明:反应器启动后具有同步硝化反硝化功能;当处理市政污水时,设定曝气压力为0.015 MPa,断面流速为2.5 mm/s,HRT为24 h,COD、NH4+-N和TN去除率分别达到99.9%、97.8%和86.69%;当处理空间站模拟废水(稀释10%)时,补充碳源150 mg/L(葡萄糖),曝气压力为0.02 MPa,断面流速为2.5 mm/s,HRT为24 h,COD、NH4+  相似文献   

9.
移动床生物膜反应器(Moving Bed Biofilm Reactor,MBBR)兼具活性污泥和生物膜两者的优点,硝化和反硝化能同步进行。为研究曝气量对MBBR运行效果的影响,分别设置曝气量为0.3 L/min、0.4 L/min和0.5 L/min,培养5 d后测定反应器中NH4+-N、NO2--N、NO3--N浓度变化,分析不同曝气量下反应器生物膜中微生物的硝化活性差异。结果表明,在COD浓度为350 mg/L、NH4+-N浓度为45 mg/L时,曝气量为0.4 L/min的微生物硝化活性最佳,结果为以后高效运行MBBR提供依据。  相似文献   

10.
张建华  彭永臻  张淼  孙雅雯  王淑莹  王聪 《化工学报》2016,67(11):4817-4824
以低C/N比实际生活污水为处理对象,聚氨酯海绵填料为生物载体(填料填充率25%),采用逐步提高氮负荷的方式,在较短的时间内(98 d)成功启动了同步硝化反硝化(simultaneous nitrification and denitrification,SND)的序批式生物膜反应器(sequencing batch biofilm reactor,SBBR)。实时定量PCR(real-time qualitative polymerase chain reaction,real-time qPCR)结果表明系统内硝化菌得到富集。在稳定运行期间,系统对有机物及氮的去除效果良好,平均出水COD、NH4+-N、TN分别为38.28 mg·L-1、1.23 mg·L-1、8.23 mg·L-1。微生物将大部分碳源以聚羟基脂肪酸酯(poly-β-hydroxyalkanoate,PHA)的形式储存至体内,系统内NO3--N的去除主要通过内源反硝化作用,且反硝化过程基本无NO2--N积累,平均SND率为70.57%,TN去除率高达82.95%。由于硝化反应和反硝化反应在同一反应器内同时进行,反硝化过程产生的碱度可补充硝化过程消耗的碱度,维持系统内pH的相对稳定。此外,可以通过DO和pH的变化判断SND的进行状态,有效地控制反应时间,节省动力消耗。  相似文献   

11.
In this study, the performance of a sequencing batch biofilm reactor (SBBR) for removal of nitrogen and phosphorus from swine wastewater was evaluated. The replacement rate of wastewater was set at 12.5%throughout the exper-iment. The anaerobic and aerobic times were 3 h and 7 h, respectively, and the dissolved oxygen concentration of the aerobic phase was about 3.95 mg·L?1. The SBBR process demonstrated good performance in treating swine wastewater. The percentage removal of total chemical oxygen demand (COD), ammonia nitrogen (NH4+-N), total nitrogen (TN), and total phosphorus (TP) was 98.2%, 95.7%, 95.6%, and 96.2%at effluent concentrations of COD 85.6 mg·L?1, NH4+-N 35.22 mg·L?1, TN 44.64 mg·L?1, and TP 1.13 mg·L?1, respectively. Simultaneous nitrification and denitrification phenomenon was observed. Further improvement in removal efficiency of NH4+-N and TN occurred at COD/TN ratio of 11:1, with effluent concentrations at NH4+-N 18.5 mg·L?1 and TN 34 mg·L?1, while no such improvement in COD and TP removal was found. Microbial electron microscopy analysis showed that the fil er surface was covered with a thick biofilm, forming an anaerobic–aerobic microenvironment and facilitating the removal of nitrogen, phosphorus and organic matters. A long-term experiment (15 weeks) showed that stable removal efficiency for N and P could be achieved in the SBBR system.  相似文献   

12.
不同来源家庭户用沼气池沼液成分分析及风险评价   总被引:1,自引:0,他引:1       下载免费PDF全文
采集了中国8个省市的43个不同原料家庭户用沼气池的沼液,进行化学需氧量(COD)、氨氮(NH4+-N)、磷酸盐(PO43-)和重金属等指标分析,阐述不同原料导致沼液成分的差异,评价了不同来源沼液存在的生态风险,旨在为不同来源沼液的资源化利用提供理论依据。研究结果表明,以牛粪和秸秆为原料的沼液COD浓度较高,分别达到6800 mg·L-1和5800 mg·L-1;以猪粪和混合粪便为原料的沼液氨氮浓度较高,都超过1800 mg·L-1,而牛粪原料沼液氨氮浓度明显低于其他原料,平均值仅有450 mg·L-1,因此以牛粪为原料的沼液COD/NH4+-N显著高于其他三种原料,COD/NH4+-N达到15,而其他三种原料的沼液COD/ NH4+-N均低于5;所有原料沼液磷酸盐浓度的平均值均低于80 mg·L-1;沼液中汞的污染较严重,且在不同原料和不同地区的沼液中具有普遍性;潜在生态风险指数RI分析结果表明,云南、河南和湖北的沼液RI介于130~260之间,属于中等生态危害,存在一定的生态风险。  相似文献   

13.
为了考察单级SBR处理实际中期垃圾渗滤液深度脱氮的可行性,采用单级SBR在“厌氧/好氧/缺氧”(AOA)运行方式下处理实际中期垃圾渗滤液。试验发现,厌氧/好氧/缺氧交替运行下驯化的微生物能在厌氧段消耗胞内糖原,并将水中部分溶解性有机物以聚羟基脂肪酸酯(PHAs)形式储存;在好氧段微生物消耗胞内PHAs,转化为胞内糖原,氨氧化的同时也伴随着同步硝化反硝化脱氮;好氧段氨氧化结束后贮存的碳源(PHAs和糖原)能为后置缺氧反硝化提供碳源。经长期试验研究,进水COD、NH4+-N、TN浓度分别为6430~9372 mg·L-1、1025.6~1327 mg·L-1、1345.7~1853.9 mg·L-1,出水COD、NH4+-N、TN浓度能达到525~943 mg·L-1、1.2~4.2 mg·L-1、18.9~38.9 mg·L-1。在未投加外碳源的情况下,SBR法AOA运行方式下能够实现中期垃圾渗滤液的深度脱氮,出水TN<40 mg·L-1。其中,好氧段(DO<1 mg·L-1)通过同步硝化反硝化去除TN占总去除量的1/3左右;缺氧后置反硝化去除的TN占总去除量的2/3左右。  相似文献   

14.
王成  孟佳  李玖龄  李建政  赵贞 《化工学报》2016,67(9):3895-3901
针对高氨氮低C/N比干清粪养猪废水处理面临的脱氮问题,制作并运行了一种升流式微氧生物膜反应器(UMBR),考察了废水水质和由出水回流比调控的溶解氧(DO)对系统处理效能的影响。结果表明,将系统内DO控制在0.23~0.70 mg·L-1范围,不会对UMBR的COD去除率造成不良影响,而且能够保证NH4--N的氧化效能。但DO为0.70 mg·L-1的微氧环境,会抑制厌氧氨氧化作用,降低系统的TN去除效能。在HRT 8 h、27℃和DO 0.40 mg·L-1的条件下,UMBR对NH4--N和TN的去除负荷平均可达0.94和0.91 kg·m-3·d-1,COD去除负荷也能达到0.60 kg·m-3·d-1左右。分析认为,填料的布设及生物膜的着生,不仅保证了UMBR的微生物持有量,而且可为化能自养菌群、氨氮氧化菌群、自养反硝化菌群和异养反硝化菌群等微生物类群创造各自适宜的微环境,是系统保持污染物高效去除的生物学基础。  相似文献   

15.
赵博玮  李建政  邓凯文  孟佳 《化工学报》2015,66(6):2248-2255
为处理高氨氮、低C/N比的养猪废水厌氧消化液, 构建了具有缓释碳源特性的木质框架土壤渗滤系统(WFSI), 并通过运行测试了进水浓度和表面水力负荷(SHL)对系统处理效能的影响。在SHL为0.2 m3·m-2·d-1条件下, 当进水COD和NH4+-N平均浓度分别从152和175.5 mg·L-1提高到421和788.7 mg·L-1时, 系统对COD的去除率从52.3%提高到61.2%, NH4+-N去除率从84.2%下降到61.5%, TN去除率从28.6%提高到了33.5%, NH4+-N和TN去除负荷分别达到了75.5和41.7 g·m-3·d-1。当SHL提高为0.32 m3·m-2·d-1时, 系统仍能维持运行, 但处理效能受到显著影响。在进水COD 和NH4+-N分别为265和465 mg·L-1左右时, COD、NH4+-N及TN的去除率分别平均为56.5%、53.3%和20.9%。木质填料及其附着层形成的NH4+-N浓度梯度, 可使系统承受较高的SHL的同时获得缓释碳源, 并保护氨氧化细菌免受自由氨毒性。  相似文献   

16.
向厌氧氨氧化反应器内投加填料形成生物膜有利于污泥的持留,然而有关填料本身的不同特点对厌氧氨氧化生物膜生长影响的报道较少。将两种不同密度的悬浮塑料填料和两种不同密度的海绵填料置于同一反应器内,进行厌氧氨氧化污泥的挂膜,结果发现海绵填料的单个填料氨氮平均去除速率和亚硝态氮平均去除速率整体高于悬浮塑料填料,所挂污泥的EPS含量整体也高于悬浮塑料填料,并且挂膜速度也相对较快。在挂膜30 d后,单个小密度海绵填料便可检测出氨氮和亚硝态氮去除速率,且Δ(NO2--N)/(NH4+-N)值接近1.32。在挂膜105 d后,单个小密度海绵填料的氨氮平均去除速率为0.123 mg·L-1·h-1,亚硝态氮平均去除速率为0.160 mg·L-1·h-1,值为1.30,最为接近理论值1.32,厌氧氨氧化活性为最佳,并且其所挂污泥的厌氧氨氧化菌丰度值在4种填料中最大,为1.73×1010 copies·(g dry sludge)-1,总体来看小密度海绵填料的挂膜效果更好。  相似文献   

17.
Wastewaterwith high NH4+-N is difficult to treat by traditional methods. So in this paper, a wild strain of photosynthetic bacteria was used for high NH4+-N wastewater treatment together with biomass recovery. Isolation, identification, and characterization of the microorganism were carried out. The strain was inoculated to the biological wastewater treatment unit. The impacts of important factorswere examined, including temperature, dissolved oxygen, and light intensity. Results showed that photosynthetic bacteria could effectively treat high NH4+- Nwastewater. Forwastewaterwith NH4+-N of 2300 mg · L-1, COD/N=1.0, 98.3% of COD was removed, and cell concentration increased by 43 times. The optimal conditions for the strain's cell growth and wastewater treatment were 30 ℃, dissolved oxygen of 0.5-1.5 mg · L-1 and a light intensity of 4000 lx. Photosynthetic bacteria could bear a lower C/N ratio than bacteria in a traditionalwastewater treatment process, but the NH4+-N removal was only 20%-40% because small molecule carbon source was used prior to NH4+-N. Also, the use of photosynthetic bacteria in chickenmanurewastewater containingNH4+-Nabout 7000mg· L-1 proved that photosynthetic bacteria could remove NH4+-N in a real case, finally, 83.2% of NH4+-N was removed and 66.3% of COD was removed.  相似文献   