首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

2.
The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study.  相似文献   

3.
This animal study compared the response of canine mandibular bone using the orthopedic principle of osteocompression by the function of an immediately loaded dental implant vs an unloaded dental implant of the same design and size. Two dogs were partially edentulated in the mandible. A total of 8 osteocompressive screw implants, 2 per quadrant were placed and evaluated histomorphometrically after 3 days in 1 dog and after 3 months in the second dog. The second dog had a two-unit fixed bridge placed immediately postsurgically in occlusal function on the right side; on the left side, the implants were splinted out of occlusion as a control. Histologically, no bone necrosis was observed at the implant interface by any of the 8 implants for either period as a direct result of the 4-mm-diameter by 13-mm-length implant design. Clinical parameters did not differ among the implants; however, at 3 months, the immediately loaded implants demonstrated more than twice the amount of bone density at their surfaces compared to the unloaded implants of the same design. Future human clinical research would be necessary to provide a meaningful statistical analysis to validate the importance of this implant design and the function of osteocompression.  相似文献   

4.
Since August 1989, 35 consecutive patients were treated with immediate implants to replace 50 teeth requiring extractions as a result of root fractures, endodontic instability, nonrestorable carious lesions, or periodontal disease. Defects relative to the implant were morphologically grouped and were treated for bone regeneration with demineralized freeze-dried crushed cancellous bone (DFDBA), e-PTFE membrane, or both. Thread exposure initially ranged from 4 to 20 threads, while implant lengths varied from 8.5 to 18 mm. The mean implant length was 15 mm, with mean thread exposure of 11.34 threads, or 54% of the threaded length of the implant. Reentry confirmed 100% thread coverage in all but one implant in the no-wall group treated with DFDBA alone. Histologic evaluation of three cases confirmed viability of the regenerated bone. The patients were followed through April 1993, with 49 implants (98%) remaining osseointegrated and functional, supporting the predictability of immediate implant placement. The age of the patients ranged from 16 to 80 years, hence implant placement considerations relative to adolescents are also discussed.  相似文献   

5.
The present study examined the influence of bone quality on the transmission of occlusal forces for endosseous dental implants. Employing the finite element method, the study modeled a 3.75 x 10-mm threaded implant placed in a 12 x 11 x 8-mm section of bone. By varying the elastic parameters assigned to the bone elements, four bone quality categories were established. A load of 100 N was applied at the occlusal surface of the restoration at a 30 degrees angle to the vertical axis of the implant. Maximum von Mises stress concentrations (sigma Emax) were observed to be located in the marginal bone at the coronal aspect of the implant fixture in all four cases. Values of sigma Emax were 13.7 MPa for type 1 bone, 15.8 MPa for type 2 bone, 20.1 MPa for type 3 bone, and 26.5 MPa for type 4 bone. Magnitude of the stresses in bone was strongly correlated (r = 0.997) with computed displacement of the implant system. This analysis predicts that placement of implants in bone with greater thickness of the cortical shell and greater density of the core will result in less micromovement and reduced stress concentration, thereby increasing the likelihood of fixture stabilization and tissue integration.  相似文献   

6.
The osteogenesis of mandibular bone to endosteal dental implants was examined using an in vivo dog model. One half of the implants examined were unloaded implants, with the remaining one half prosthodontically loaded for 6 months. Undecalcified mandibular implant samples were examined with both high-voltage electron microscopy (HVEM) stereology and routine transmission electron microscopy. The osseous interface to integrated implants was shown to vary in its morphology. Mineralized bone was observed directly apposing the implant, often separated from the implant by an electron-dense deposit of approximately 50 nm. Within this densely mineralized matrix, osteocytes were routinely observed. Adjacent areas were shown to contain slightly wider zones of either a less dense mineralized matrix or, alternatively, unmineralized tissue. Other zones consisted of wider unmineralized matrices containing collagen fibers and osteoblasts. These latter zones were consistent with the appearance of an appositional type of bone growth. Because bone is a dynamic, actively remodeling tissue, a varied morphology of the support tissues to dental implant is not unexpected. Areas of mature bone interfacing with successfully integrated implants were demonstrated, as well as areas adjacent to the mature bone that were undergoing remodeling or mineralization. This study has also shown that HVEM stereology is a valuable research tool to investigate the oral tissue interface with dental implants.  相似文献   

7.
The aim of this study was to evaluate clinically, histologically and histometrically the use of anorganic bovine bone matrix (i.e. Bio-oss) as a grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (i.e. Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted. The remaining bone between the alveolar crest and the bottom of the sinus was then reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed on one side of the jaws in each monkey and the sinuses were grafted with the bovine bone matrix. At that time, 2 IMZ pure titanium plasma coated implants were immediately placed into the augmented sinuses (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into these previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received the same treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants-unloaded group and delayed implants-unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologically, the grafted sinuses exhibited significant bone formation with integration of the bovine bone matrix particles to the new bone. Direct mineralized bone-to-implant contact was greater for the delayed implant placement groups than for the implants installed simultaneously with the sinus augmentation. Furthermore, the percentage of direct mineralized bone-to-implant contact was greater in the residual bone than in the augmented area. It was concluded that the anorganic bovine bone matrix facilitated bone formation and implant osseointegration in the augmented sinuses and that the delayed implant placement in combination with the sinus augmentation procedure seemed to be preferable.  相似文献   

8.
The specific aim of this study was to determine the response of alveolar bone after it was augmented vertically using distraction osteogenesis and subsequently loaded with implant restorations. Four dogs each had four implants placed horizontally into an edentulous mandibular quadrant and, after integration, a distraction osteogenesis device was fabricated in the laboratory. An osteotomy was made to allow the crest of the alveolar ridge to be distracted vertically. After 10 mm of vertical distraction, the device was stabilized with light cured resin. Following bone fill confirmation of the distraction gap at 10 weeks, two implants were placed into the ridges, one in distracted bone and one in nondistracted bone. After 4 months for implant integration, freestanding prostheses were fabricated. Crestal bone levels were evaluated throughout the period of function. Animals were sacrificed after 1 year of loading, for histologic evaluation of the bone. The vertical ridge augmentation averaged 8.85 +/- 1.05 mm after 10 weeks of healing following distraction, without change over 1 year of implant loading. Histologic examination showed that bone had formed between the distracted segments, creating an augmented ridge. The average thickness of the labial cortex in the distraction gap was significantly thinner than the lingual cortex in distracted bone and the lingual and labial nondistracted cortical bone. The presence of the dental implant did not significantly affect cortical bone thickness. Serial sections showed that implants remained integrated and functional without soft tissue inflammation. Dental implants placed into alveolar ridges augmented with the technique of distraction osteogenesis maintained bone and were functional for the length of this study.  相似文献   

9.
We hypothesized that reduced stem stiffness of orthopaedic implants contributes to a high risk of loosening, since interface stresses and relative motions may exceed a tolerable range. To study this hypothesis, three types of load-bearing implant with different stiffnesses were inserted into the tibia of the goat. Histological analysis was performed of bone repair after insertion of the implant, bone ingrowth, interface disruption and loosening. A finite element model of the configuration provided the quantitative range of interface stresses and relative motions for the present experiment. The implants were made out of stainless steel, hollow titanium and a thin titanium core covered with a polyacetal coating. The stiffness ratios of these implants were approximately 10:4:1, respectively. All implants were coated with a layer of hydroxyapatite (HA) in order to minimize the possible biological effects of the different implant materials. Irrespective of the type of implant, there was a repair phase that lasted 6-12 weeks. The stiff implants functioned well. Large areas of bone bonding to the HA layer were found after the repair phase at 12 weeks postoperatively. After 24 weeks, some signs of loosening were observed. More loosening occurred with the hollow titanium and polyacetal implants, mainly during the repair phase. Three hollow titanium and three polyacetal coated implants survived this period, and were killed after 24 weeks. The integrity of the HA layer at the bone-implant interface of the titanium implants was good. In the polyacetal implants, the repair reaction of the cortical bone was incomplete. Bone ingrowth into HA was largely lacking. In conclusion, we found significant differences in the repair and interface reactions around implants of different stiffness. Stiff implants showed favourable initial interface conditions for bone ingrowth. Intermediate and flexible implants provoked unfavourable interface conditions for initial bone ingrowth. The finite element study showed that the flexible stems produce larger micromotions and higher interface stresses at the bone-prosthesis interface than the stiff stems, indicating an explanation for the histological findings.  相似文献   

10.
This investigation was initiated to develop a method to provide patients with a fixed provisional prosthesis placed at the time of implant placement. Sixty-three standard 3.75-mm Nobel Biocare implants of varying lengths were placed into mandibular sites in 10 patients and followed for up to 10 years. Twenty-eight implants were immediately loaded at implant placement, providing support for fixed provisional prostheses, while 35 adjacent implants were allowed to heal submerged and stress-free. Following a 3-month healing period, the submerged implants were exposed and definitive reconstruction was accomplished. All 10 prostheses supported by 28 implants placed into immediate function at the time of implant placement were successful during the 3-month healing period. Of these 28 implants placed into immediate function, 4 ultimately failed. Of the 35 submerged implants, all are osseointegrated and in function to date. Life-table analysis demonstrates an overall 10-year survival rate of 93.4% for all implants. The 10-year life-table analysis of survival is 84.7% for immediately loaded implants and 100% for submerged implants. Statistical analysis of the submerged versus immediately loaded implants demonstrates failure rates for immediately loaded implants to be significantly higher (P = .022 by the log rank test). These data demonstrate that although mandibular implants can be successfully placed into immediate function in the short term to support fixed provisional prostheses, long-term prognosis is guarded for those implants placed into immediate function distal to the incisor region.  相似文献   

11.
Bone cement is commonly used to affix femoral implants to the bone during total hip reconstruction. Previous studies suggest that the expected life of a cemented femoral implant may depend on the thickness of the cement mantle surrounding the implant and the implant geometry. The purpose of this study was to determine whether different cement-mantle thicknesses and femoral stem sizes affected strain patterns in the bone cement around cemented femoral stems. Two different sizes of cobalt-chromium stems were cemented into composite femora with varying cement-mantle thickness. Strain gages were embedded in the cement mantle and the implanted stems were loaded axially and under conditions simulating walking and standing. An increase in stem size with the same cement-mantle thickness (approximately 2.2 mm) caused a 65% decrease in proximal medial cement strains. Increasing cement mantle thickness from 2.4 to 3.7 mm caused substantial strain reductions in the distal cement (40-49%). We conclude that increased cement-mantle thickness around femoral stems may increase the fatigue life of a bone-implant system by reducing peak strains within the cement.  相似文献   

12.
Opportunities to increase prosthetic treatment efficiency by means of applying osseointegrated implants of traditional and prospective types are analysed. A technique of mathematical modelling of the interaction between implants and jaw bone is exposed. The numerical model and applied program, developed on the basis of finite element method, enabling to analyse a stress strain state of the bone and to determine extreme safe loads on implants are described. It is shown, that the most loaded zone is a layer of the compact bone directly contiguous to the neck of the implant. That is in good agreement with the results of clinical research, according to which just this zone has the highest percentage of complications. Methods for further optimisation of implants and prosthetic structures for the purpose to perfect the techniques of prosthetic treatment are discussed.  相似文献   

13.
PURPOSE: This retrospective study investigated the survival of dental implants placed in the maxilla after composite grafting of the sinus and an average of 55 months of loading. PATIENTS AND METHODS: Maxillary sinuses of 88 patients were grafted with autogenous cancellous bone combined with dense hydroxyapatite particles. After an average healing period of 3.4 months, hydroxyapatite-coated titanium endosseous implants were placed. A total of 388 implants were placed in grafted sinus floors, and 82 were placed in onlay grafted nonsinus position in the canine region. The implants were loaded with overdentures and fixed bridges 4 months (mean) after implantation, with a follow-up for a mean of 55 months. RESULTS: The cumulative implant survival was calculated according to the Kaplan-Meier method. Implant survival from the time of loading was 89% in full reconstructed cases and 90% in partially edentulous cases. The overall cumulative implant survival rate, including the loss in the surgical stage, was 82%. CONCLUSION: Implant loss in composite grafted maxillae after 70 months of follow-up was similar to loss in nongrafted maxillae.  相似文献   

14.
The feasibility of implant treatment in patients after oral ablative tumor surgery has not yet been investigated with consideration of the requisite high periodontal standards. A report on this topic has to deal not only with implant survival but also with implant health, bone response, soft tissue health, failure pattern, time of failure, and ease of restoration. For the assessment of an implant system, an overview must be accomplished that takes into account the different restorations used and their interaction with the implant system that was used. This study presents the Bone-Lock implant system (Howmedica Leibinger GmbH, Freiburg, Germany) in a retrospective investigation after 5 years of follow-up with special emphasis on the prosthetic restorations used following resection of oral malignancies. From early in 1990 through June 1996, we inserted 210 dental endosteal Bone-Lock implants (58 patients) after oral tumor resectioning. Included in the study were 45 patients with 162 implants and prosthetic restorations that had been loaded for 1 year (dentures retained by telescopic or bar-clip or ball attachments, implant-supported prostheses, tooth-to-implant connected bridges). Regular follow-up consisted of evaluation of the Plaque Index (Silness and L?e) and of the Sulcus Bleeding Index (L?e), measurements of pocket probing depth, implant mobility (by means of the Periotest method), bone resorption (according to X-ray findings), and a questionnaire that registered patient satisfaction. The results were evaluated for each restoration and were compared with baseline standards. The overall 5-year survival rate was 83.2%. For implants that had been in place for over 365 days, the survival rate was 93%. The investigation showed that after resection of oral malignancies, patients could be treated with dental implants and superstructures with long-term efficacy similar to that found in healthy subjects considering internationally accepted standards. Implant treatment in tumor patients appeared to offer the most positive periodontic results when use of bar-clip or telescope-retained overdentures was involved. The patient satisfaction level with the described prosthodontic treatment was satisfactory.  相似文献   

15.
In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implant the apical border of the polished surface was placed approximately 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and "attachment" levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p < 0.05) was found between test and control implants with the test implants being placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p < 0.05; control 0.58 mm, p < 0.05). However, only the test implants significantly lost clinical bone height from 4-12 months (test 1.04 mm, p < 0.05; control 0.45 mm, p = 0.08). Overall, the test implants lost 2.26 mm and the control implants 1.02 mm of bone height during the first year of service. On the average, the test implants demonstrated a bone level of 0.38 mm lower than the controls at 12 months. Except for the modified gingival index at 4 months (mean difference 0.21, SD 0.19, p < 0.05), no clinical parameters yielded significant differences between test and control implants at any time. It is concluded that in addition to the crestal bone resorption occurring at implants placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. From a biological point of view, the placement of the border between the rough and the smooth surfaces into a subcrestal location should not be recommended.  相似文献   

16.
The response of mandibular bone to identical geometry LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants in baboons for 2 years was evaluated using histologic, microradiographic, and scanning electron microscopic methods. In addition, a quantitative histologic analysis was performed identifying the type, amount, and distribution of tissue surrounding the dental implant systems. This is the final phase of a study investigating the effect of implant elastic modulus and implant surface chemical composition on the performance of dental implants. Previous studies have utilized clinical and radiographic evaluations, postretrieval mechanical testing, and finite element stress analysis to evaluate the dental implant performance. The results of the histologic study revealed a direct implant-bone interface with no intervening soft tissue in 16 of the 21 implants (76%). A fibrous tissue interface was observed in 5 of 21 implants (24%). Quantitative histologic results for the implants with a direct implant-bone interface showed statistically larger crestal cortical plates (p less than 0.05) and greater area fraction crestal cancellous bone (p less than 0.05) in the LTI carbon implant compared to the carbon-coated and uncoated aluminum oxide implants. The carbon-coated and uncoated aluminum oxide implants demonstrated statistically greater area fraction cancellous bone at the inferior region of the implant (p less than 0.05) and thinned and reduced crestal cortical plates when compared to the LTI carbon implants. The results indicate that significant stress shielding of the crestal bone had occurred with the rigid carbon-coated and uncoated aluminum oxide implants when compared to the LTI carbon implants which had a material elastic modulus similar to cortical bone. Based upon the histologic results, it appears that the LTI carbon implants with the direct implant-bone interface exhibited a greater potential for long-term successful performance compared to the aluminum oxide substrate implants.  相似文献   

17.
While the original Br?nemark implant protocol has continued to evolve, the avoidance of implant loading during osseointegration remains a prerequisite with all implant systems. Immediately loaded transitional implants have recently been developed to support the fabrication of a fixed provisional prosthesis that provides implant patients with improved aesthetics and function during the osseointegration period. In this manner, osseointegration can occur free from prosthetic and transmucosal loads. This article describes the use of transitional implants and presents a classification of three different case types.  相似文献   

18.
This paper describes rapid bone resorption in the peri-implantitis of HA implants based on both our clinical observations of and histological research on extracted dense hydroxyapatite (HA) implants. The surfaces of extracted HA implants were rough, although they were smooth at fixture placement. Plaque formed on the necks of the implants, whereas little plaque was seen on the bottoms. The plaque consisted of cocci and rods, including filamentous bacteria. Few spirochetes were observed. Although surrounding bone was formed rapidly around the HA implant, bone thickness gradually decreased compared with the titanium implant. These facts suggest that the rigid biointegration of HA with the thin surrounding bone--that is, the overstressing of the bone--causes rapid bone resorption rather than plaque accumulation on HA.  相似文献   

19.
The postmortem examination of bilateral first metatarsophalangeal flexible hinge toe implants in a 66-year-old woman with rheumatoid arthritis is reported. The prosthesis had been inserted with grommets in 1 joint and without grommets in the other 2.5 years before her death. The implants were removed, and the bone/implant interfaces were examined microscopically by hematoxylin eosin stains and an electron probe microanalyzer. Surfaces of the implants were examined by scanning electron microscopy. Silicone particles within the fibrous tissue at the bone/implant interface, and a tear and significant scuffing of the implant surface, were detected in the joint without grommets. Such changes were not detected in the joint with grommets. These findings suggest that grommets may improve implant durability and preventing silicone synovitis.  相似文献   

20.
The histologic examination of dental implants retrieved from humans is important to establish the causal determinants of implant failure, and to compare and validate the results obtained from animal studies. This study presents a retrospective review of the histologic features of 230 implants retrieved in an 8-year period (1989-1996). All the implants were treated to obtain thin (20 to 30 microm) ground sections. The majority of implants were retrieved because of mobility (n=56), peri-implantitis (n=54), or fractures (n=90). Peri-implantitis occurred more frequently before (n=44) than after (n=10) abutment connection. A dense fibrous connective tissue with no inflammatory cells was present at the interface in the implants retrieved for mobility; bone was found only in the most apical part. In many of these implants epithelial cells were present. The main histologic features of peri-implantitis consisted of the presence of a bone sequestrum near the implant, many bacteria present on the implant surface, and an inflammatory infiltrate (macrophages, lymphocytes, and plasma-cells) nearby. Histology showed that in the implants removed for fracture, there was a very high percentage (80 to 100%) of peri-implant bone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号