首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
马志虎 《山西建筑》2007,33(25):199-200
以某文体活动中心为例,从耗热量计算、空气源热泵的选型、空气源热泵的能耗计算三方面阐述了空气源热泵技术在游泳池水加热中的应用,并将其与燃油锅炉的能耗费用进行了比较,以说明空气源热泵技术的优越性。  相似文献   

2.
游泳馆内冬季足部寒冷的解决方法   总被引:2,自引:1,他引:1  
牟歆 《暖通空调》1999,29(2):46-48
给出了舒适环境下的足部温度值,分析了冬季室内游泳馆导致足部寒 因素,并提出了3各解决办法。  相似文献   

3.
室内恒温游泳馆由于散湿量大,能耗高,采用热泵技术回收游泳馆内热湿空气中的热量是降低恒温游泳池能耗的有效措施,对于目前广泛采用的2种空调热回收系统,本文给出详细的对比分析,并得出结论,为恒温游泳馆空调系统方案选择提供参考意见。  相似文献   

4.
H.T. Hsu  M.J. Chen  C.H. Lin  W.S. Chou  J.H. Chen   《Water research》2009,43(15):3693-3704
Human exposure to chloroform in indoor swimming pools has been recognized as a potential health concern. Although environmental monitoring is a useful technique to investigate chloroform concentrations in indoor swimming-pool air, in practice, the interpretations of measured data would inevitably run into difficulties due to the complex interactions among the numerous variables, including environmental conditions and occupant activities. Considering of the relevant variables of environmental conditions and occupant activities, a mathematical model was first proposed to predict the chloroform concentration in indoor swimming-pool air. The developed model provides a straightforward, conceptually simple way to predict the indoor air chloroform concentration by calculating the mass flux, J, and the Péclet number, Pe, and by using a heuristic value of the indoor airflow recycle ratio, R. The good agreement between model simulation and measured data demonstrates the feasibility of using the presented model for indoor air quality management, operational guidelines and health-related risk assessment.  相似文献   

5.
王桂林 《山西建筑》2010,36(20):179-180
通过工程实例介绍了空气源热泵辅助太阳能泳池加热系统的工作原理、系统原理图以及运行控制策略,通过节能技术的组合,以达到节能减排的效果,并尽可能实现工程投资经济和系统运行安全的最佳组合。  相似文献   

6.
在该恒温游泳池设计中引入了自然通风系统,结合CFD模拟结果确定了进排风方案。给出了自然通风、自然通风与机械通风联合运行和空调运行的逻辑判定条件。采用广州市典型气象年的气象资料计算了全年通风运行时间,并通过全年能耗模拟分析了其节能效益。  相似文献   

7.
赵素丽  李洪强 《山西建筑》2011,37(24):121-123
针对室内游泳池因通风空调设计不当造成的防结露问题,分析了游泳池特殊的温湿度环境,指出解决此问题可以采取的措施,并准确计算游泳池散湿量、通风量等,合理进行气流组织设计,从源头杜绝结露问题的发生。  相似文献   

8.
邱林 《暖通空调》2006,36(6):44-46,9
分析了燃气机热泵热电冷三联供系统节能的热力学原理及应用优势,探讨了不同季节采用不同的联供运行模式一次能源利用率PER的情况,并就影响PER的主要因素——废热回收率、热泵性能系数及用于发电的燃气能量占燃气总能量的比例的变动效应进行了模拟计算,给出了燃气机热泵不同联供运行工况下PER的对比及规律。  相似文献   

9.
王晓峰 《山西建筑》2003,29(7):125-126
结合设计实例 ,对室内游泳池的给排水设计作了简单介绍 ,指出应根据实际情况及甲方的要求 ,在设计中对工程投资及适用性予以重视  相似文献   

10.
介绍了北京室内游乐馆的结构体系、结构规则性、荷载分项系数、材料等内容,并进行了多遇地震内力分析、性能化分析和设计以及基础分析,结果表明:该设计满足规范要求,达到了预期目标。  相似文献   

11.
对夏热冬冷地区的办公楼,设计了一种燃气热泵结合除湿转轮的温湿度独立控制空调系统,并计算了其能耗和运行费用.结果表明在该地区能源价格下,该系统的能源消耗与费用明显低于电驱动空气源热泵,节能效果显著.  相似文献   

12.
马景月 《住宅科技》2009,28(1):32-35
文章论述了居住区室内游泳池设计的一般要求,并结合实例介绍了室内游泳池、游泳馆的建筑设计及细部设计做法:  相似文献   

13.
Study on hybrid ground-coupled heat pump systems   总被引:1,自引:0,他引:1  
Although ground-coupled heat pump (GCHP) systems are becoming attractive air-conditioning systems in some regions, the significant drawback for their wider application is the high initial cost. Besides, more energy is rejected into ground by the GCHP system installed in cooling-dominated buildings than the energy extracted from ground on an annual basis and this imbalance can result in the degradation of system performance. One of the available options that can resolve these problems is to apply the hybrid ground-coupled heat pump (HGCHP) systems, with supplemental heat rejecters for rejecting extra thermal energy when they are installed in cooling-dominated buildings. This paper presents a practical hourly simulation model of the HGCHP system by modeling the heat transfer of its main components. The computer program developed on this hourly simulation model can be used to calculate the operating data of the HGCHP system according to the building load. The design methods and running control strategies of the HGCHP system for a sample building are investigated. The simulation results show that proper HGCHP system can effectively reduce both the initial cost and the operating cost of an air-conditioning system compared with the traditional GCHP system used in cooling-dominated buildings.  相似文献   

14.
马德慧 《山西建筑》2011,37(24):89-90
结合山西体育中心比赛用游泳池的工程设计情况,重点针对游泳池赛道长度施工提出了质量控制措施,经施工中的严格控制,赛道长度完全符合泳联的有关标准规定。  相似文献   

15.
张如心 《山西建筑》2005,31(7):147-148
结合工程实例,介绍了比赛娱乐两用游泳池的给排水设计,从游泳池的规格尺寸、池水的循环方式、池水净化系统等方面进行了论述,提出了推广“两用型”设计的几点改进意见。  相似文献   

16.
能源塔热泵技术在空调工程中的应用与分析   总被引:2,自引:0,他引:2  
介绍了能源塔热泵技术的发展、原理和分类,分析了能源塔热泵的特点,简要阐述了能源塔热泵的关键技术问题、设计要点和运行管理方式。指出能源塔不同于冷却塔,用冷却塔代替能源塔会因为吸收低品位热源的能力不足而使能源塔热泵不能正常工作。将能源塔与其他空调方式进行了比较,认为在我国长江以南地区的新建建筑或既有建筑改造中,能源塔热泵是一种制冷制热设备的新选择。  相似文献   

17.
吴薇  张小松 《暖通空调》2007,37(5):108-111,82
介绍了水环热泵空调系统辅助热源的形式,提出了采用空气源和电加热作为辅助热源的空气源-水环复合热泵空调系统,研究了不同室外温度时建筑不同内外区冷热负荷比下该系统的能耗,分析了循环水温对系统能耗的影响,比较了该系统与采用电热锅炉和燃煤锅炉的传统水环热泵空调系统的一次能耗。  相似文献   

18.
通过大量的实验和对实验数据的系统分析,得到华北某城市污水源热泵系统的变工况运行特性以及污水源热泵蒸发换热器换热系数的变化规律。污水源热泵蒸发换热器换热系数的变化特性是污水源热泵系统热工计算的基础;污水源热泵系统的变工况运行特性是评价污水源热泵系统的重要指标.其中主要包括污水温度和输出负荷对机组运行参数的影响。掌握了污水源热泵系统的变工况运行特性。可以得到污水源热泵蒸发换热器和污水源热泵机组的最优运行工况。  相似文献   

19.
赵金秀 《山西建筑》2008,34(5):257-258
介绍了热泵系统的工作原理、组成及系统形式,分析了热泵系统的特点和在供热空调工程中的技术经济性,并说明了热泵是一种环保节能的能源利用技术,以推广热泵技术的应用,从而更好地节约能源.  相似文献   

20.
空气源热泵COP值与节能应用探讨   总被引:1,自引:0,他引:1  
刘国双 《山西建筑》2009,35(22):193-194
以金华市某新建工程为例,介绍了空气源热泵系统COP实际值,提出了当地全年可以达到的COP值,以某改造工程为例,分析了空气源热泵系统的节能效果,并展望其应用前景,以期推广该技术的应用。  相似文献   