首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.  相似文献   

2.
Jiang X  Zhuo S  Xu R  Chen J 《Scanning》2012,34(3):170-173
Mouse is an important animal model to investigate skin physiological and pathological states. In this article, multiphoton microscopic imaging of in vivo hair mouse skin based on two-photon excited fluorescence and second harmonic generation was examined. Our results show that multiphoton microscopy can clearly display microstructure of stratum corneum, stratum spinosum, and dermis of in vivo mouse skin. The main components of epidermis and dermis such as corneocytes, spinosum cell, collagen fibers, and hair follicles can be distinctly identified in MPM images. Using the optional HRZ 200 fine focusing stage, thickness of different layers can be easily assessed. The results demonstrate that MPM can be regarded as an efficient method for in vivo investigation of skin physiological and pathological states by using hair mouse animal model.  相似文献   

3.
Huang Z  Zhuo S  Chen J  Chen R  Jiang X 《Scanning》2008,30(6):452-456
The fresh adipose tissue was investigated by the use of multiphoton microscopy (MPM) based on two-photon excited fluorescence and second-harmonic generation (SHG). Microstructure of collagen and adipose cells in the adipose tissue is clearly imaged at a subcellular level with the excitation light wavelengths of 850 and 730 nm, respectively. The emission spectrum of collagen SHG signal and NADH and FAD fluorescence signal can also be obtained, which can be used to quantify the content of collagen and adipose cells and reflect the degree of pathological changes when comparing normal tissue with abnormal adipose tissue in the same condition. The results indicate that MPM has the potential to be applied to investigate the adipose tissue and can be used in the research field of lipid and connective tissues.  相似文献   

4.
Long-term high-resolution multiphoton imaging of nonlabeled human salivary gland stem cell spheroids has been performed with submicron spatial resolution, 10.5-nm spectral resolution, and picosecond temporal resolution. In particular, the two-photon-excited coenzyme NAD(P)H and flavins have been detected by time-correlated single photon counting (TCSPC). Stem cells increased their autofluorescence lifetimes and decreased their total fluorescence intensity during the adipogenic-differentiation process. In addition, the onset of the biosynthesis of lipid vacuoles was monitored over a period of several weeks in stem-cell spheroids. Time-resolved multiphoton autofluorescence imaging microscopes may become a promising tool for marker-free stem-cell characterization and cell sorting.  相似文献   

5.
6.
We demonstrate the potential of fluorescence lifetime imaging by time-correlated single-photon counting as a method for monitoring the transdermal diffusion pathway and diffusion rate of pharmaceuticals in human skin. The current application relies on observing subtle changes in the fluorescence lifetime of the intrinsic fluorophores present in the intracellular region between corneocytes of the stratum corneum. We have comprehensively characterized the measured fluorescence lifetimes from intracorneocyte junctions in three skin section types (dermatomed skin, epidermal membranes and stratum corneum) revealing statistically significant differences of the short lifetime component between each of the types, which we attribute to the sample preparation and imaging method. We show using epidermal membrane sections that application of a drug/solvent formulation consisting of ethinyl estradiol and spectroscopic grade ethanol to the surface gives rise to a slight but statistically significant shortening of the fluorescence lifetime of the long-lived emitting species present in the sample, from approximately 2.8 ns to 2.5 ns. The method may be useful for future studies where the kinetics and pathways of a variety of applied formulations could be investigated.  相似文献   

7.
Ulrich V  Fischer P  Riemann I  Königt K 《Scanning》2004,26(5):217-225
An inverted fluorescence microscope was upgraded into a compact three-dimensional laser scanning microscope (LSM) of 65 x 62 x 48 cm dimensions by means of a fast kHz galvoscanner unit, a piezodriven z-stage, and a picosecond (ps) 50 MHz laser diode at 405 nm. In addition, compact turn-key near infrared femtosecond lasers have been employed to perform multiphoton fluorescence and second harmonic generation (SHG) microscopy. To expand the features of the compact LSM, a time-correlated single photon counting unit as well as a Sagnac interferometer have been added to realize fluorescence lifetime imaging (FLIM) and spectral imaging. Using this unique five-dimensional microscope, TauMap, single-photon excited (SPE), and two-photon excited (TPE) cellular fluorescence as well as intratissue autofluorescence of water plant leaves have been investigated with submicron spatial resolution, <270 ps temporal resolution, and 10 nm spectral resolution.  相似文献   

8.
In this paper, multiphoton microscopy (MPM), based on two‐photon excited fluorescence and second harmonic generation signals, was used to image microstructures of human rectal mucosa and submucosa. The morphology and distribution of the main components in mucosa layer, goblet cells, intestinal glands, and a little collagen fibers have been clearly monitored, and the content and distribution of collagen, elastic fibers, and blood vessels in submucosa layer have also been distinctly obtained. The variation of these components is very relevant to the pathology in gastrointestinal system, especially early rectal cancer. Our results indicate that the MPM technique has the potential application in vivo in the clinical diagnosis and monitoring of early rectal cancer. SCANNING 32: 347–350, 2010. © 2010 Wiley Periodicals, Inc.  相似文献   

9.
The polar representation or phasor, which provides a fast and visual indication on the number of exponentials present in the intensity decay of the fluorescence lifetime images is increasingly used in time domain fluorescence lifetime imaging microscopy experiments. The calculations of the polar coordinates in time domain fluorescence lifetime imaging microscopy experiments involve several experimental parameters (e.g. instrumental response function, background, angular frequency, number of temporal channels) whose role has not been exhaustively investigated. Here, we study theoretically, computationally and experimentally the influence of each parameter on the polar calculations and suggest parameter optimization for minimizing errors. We identify several sources of mistakes that may occur in the calculations of the polar coordinates and propose adapted corrections to compensate for them. For instance, we demonstrate that the numerical integration method employed for integrals calculations may induce errors when the number of temporal channels is low. We report theoretical generalized expressions to compensate for these deviations and conserve the semicircle integrity, facilitating the comparison between fluorescence lifetime imaging microscopy images acquired with distinct channels number. These theoretical generalized expressions were finally corroborated with both Monte Carlo simulations and experiments.  相似文献   

10.
The real-time uptake of serotonin, a neurotransmitter, by rat leukemia mast cell line RBL-2H3 and 5-hydroxytryptophan by Chinese hamster V79 cells has been studied by fluorescence lifetime imaging microscopy (FLIM), monitoring ultraviolet (340 nm) fluorescence induced by two-photon subpicosecond 630 nm excitation. Comparison with two-photon excitation with 590 nm photons or by three-photon excitation at 740 nm shows that the use of 630 nm excitation provides optimal signal intensity and lowered background from auto-fluorescence of other cellular components. In intact cells, we observe using FLIM three distinct fluorescence lifetimes of serotonin and 5-hydroxytryptophan according to location. The normal fluorescence lifetimes of both serotonin (3.8 ns) and 5-hydroxytryptophan (3.5 ns) in solution are reduced to approximately 2.5 ns immediately on uptake into the cell cytosol. The lifetime of internalized serotonin in RBL-2H3 cells is further reduced to approximately 2.0 ns when stored within secretory vesicles.  相似文献   

11.
In this paper, microstructures of human oesophageal submucosa are evaluated using multiphoton microscopy, based on two‐photon excited fluorescence and second harmonic generation. The content and distribution of collagen, elastic fibers and cancer cells in normal and cancerous submucosa layer have been distinctly obtained and briefly discussed. The variation of these components is very relevant to the pathology in oesophagus, especially in early oesophageal cancer. Our results further indicate that the multiphoton microscopy technique has the potential application in vivo in clinical diagnosis and monitoring of early oesophageal cancer.  相似文献   

12.
Jiang X  Zhong J  Liu Y  Yu H  Zhuo S  Chen J 《Scanning》2011,33(1):53-56
Multiphoton microscopic imaging of collagen plays an important role in noninvasive diagnoses of human tissue. In this study, two-photon fluorescence and second-harmonic generation (SHG) imaging of collagen in human skin dermis and submucosa of colon and stomach tissues were investigated based on multiphoton microscopy (MPM). Our results show that multiphoton microscopic image of collagen bundles exhibits apparently different pattern in human tissues. The collagen bundles can simultaneously reveal its SHG and two-photon excited fluorescence images in the submucosa of colon and stomach, whereas it solely emit SHG signal in skin dermis. The intensity spectral information from tissues further demonstrated the above results. This indicates that collagen bundles have completely different space arrangement in these tissues. Our experimental results bring more detailed information of collagen for the application of MPM in human noninvasive imaging.  相似文献   

13.
A direct‐diode pumped Ti:sapphire femtosecond oscillator is used to perform multiphoton imaging for the first time.  相似文献   

14.
In this work, we proposed and built a multimodal optical setup that extends a commercially available confocal microscope (Olympus VF300) to include nonlinear second harmonic generation (SHG) and third harmonic generation (THG) optical (NLO) microscopy and fluorescence lifetime imaging microscopy (FLIM). We explored all the flexibility offered by this commercial confocal microscope to include the nonlinear microscopy capabilities. The setup allows image acquisition with confocal, brightfield, NLO/multiphoton and FLIM imaging. Simultaneously, two‐photon excited fluorescence (TPEF) and SHG are well established in the biomedical imaging area, because one can use the same ultrafast laser and detectors set to acquire both signals simultaneously. Because the integration with FLIM requires a separated modulus, there are fewer reports of TPEF+SHG+FLIM in the literature. The lack of reports of a TPEF+SHG+THG+FLIM system is mainly due to difficulties with THG because the present NLO laser sources generate THG in an UV wavelength range incompatible with microscope optics. In this article, we report the development of an easy‐to‐operate platform capable to perform two‐photon fluorescence (TPFE), SHG, THG, and FLIM using a single 80 MHz femtosecond Ti:sapphire laser source. We described the modifications over the confocal system necessary to implement this integration and verified the presence of SHG and THG signals by several physical evidences. Finally, we demonstrated the use of this integrated system by acquiring images of vegetables and epithelial cancer biological samples. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

15.
Papulonodular mucinosis (PM) is a cutaneous clue to the presence and activity of silent lupus erythematosus (LE), but the exact pathogenesis is still under secret. Moreover, the currently available treatments for PM are not satisfactory. To demonstrate the possibility of multiphoton microscopy (MPM) to trace the pathological state of PM and evaluate the treatment efficacy, epidermal and dermal alteration in skin lesion with PM before and after treatment was examined using MPM. Microstructure of epidermis as well as content and distribution of collagen and elastin in dermis were quantified to characterize the pathological states of PM. The results showed significant morphological difference between skin lesion before and after treatment, indicating the possibility of MPM to assess the therapeutic efficacy. With the advancement on MPM miniaturization and enhancement of contrast and depth of imaging, the MPM technique can be applied in in vivo tracking PM formation and progression, and leading the better understanding the PM pathogenesis and mechanism of response to any treatment, helping to establish novel effective therapies for PM. SCANNING 35:22‐27, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
Fluorescence lifetime imaging (FLIM) is a powerful microscopy technique for providing contrast of biological and other systems by differences in molecular species or their environments. However, the cost of equipment and the complexity of data analysis have limited the application of FLIM. We present a mathematical model and physical implementation for a low cost digital frequency domain FLIM (DFD-FLIM) system, which can provide lifetime resolution with quality comparable to time-correlated single photon counting methods. Our implementation provides data natively in the form of phasors. On the basis of the mathematical model, we present an error analysis that shows the precise parameters for maximizing the quality of lifetime acquisition, as well as data to support this conclusion. The hardware and software of the proposed DFD-FLIM method simplifies the process of data acquisition for FLIM, presents a new interface for data display and interpretation, and optimizes the accuracy of lifetime determination.  相似文献   

17.
Two-photon fluorescence lifetime imaging microscopy was used noninvasively to monitor a fluorescent antigen during macrophage-mediated endocytosis, intracellular vacuolar encapsulation, and protease-dependent processing. Fluorescein-conjugated bovine serum albumin (FITC–BSA) served as the soluble exogenous antigen. As a relatively nonfluorescent probe in the native state, the antigen was designed to reflect sequential intracellular antigen processing events through time-dependent changes in fluorescence properties. Using two-photon lifetime imaging microscopy, antigen processing events were monitored continuously for several hours. During this time, the initial fluorescein fluorescence lifetime of 0.5 ns increased to α 3.0 ns. Control experiments using fluorescein conjugated poly- l -lysine and poly- d -lysine demonstrated that the increase in fluorescence parameters observed with FITC–BSA were due to intracellular proteolysis since addition of the inert d -isomer did not promote an increase in fluorescence lifetime or intensity. Comparisons of intravacuolar and extracellular FITC–dextran concentration suggested active localization of dextran in the vacuoles by the macrophage. In addition, the kinetics of degradation observed using two-photon microscopy were similar to results obtained on the flow cytometer, thus validating the use of flow cytometry for future studies.  相似文献   

18.
19.
A variety of high resolution optical microscopy techniques have been developed in recent years for basic and clinical studies of biological systems. We demonstrate a trimodal microscope combining optical coherence microscopy (OCM) with two forms of nonlinear microscopy, namely two-photon excited fluorescence (2PF) and second harmonic generation (SHG), for imaging turbid media. OCM combines the advantages of confocal detection and coherence gating for structural imaging in highly scattering tissues. Nonlinear microscopy enables the detection of biochemical species, such as elastin, NAD(P)H, and collagen. While 2PF arises from nonlinear excitation of fluorescent species, SHG is a form of nonlinear scattering observed in materials that lack a center of inversion symmetry, such as type I collagen. Characterization of the microscope showed nearly diffraction-limited spatial resolution in all modalities. Images were obtained in fish scales and excised human skin samples. The primary endogenous sources of contrast in the dermis were due to elastin autofluorescence and collagen SHG. Multimodal microscopy allows the simultaneous visualization of structural and functional information of biological systems.  相似文献   

20.
Studies of proteins' interaction in cells by FRET can take benefit from two important photo-physical properties describing fluorescent proteins: fluorescence emission spectrum and fluorescence lifetime. These properties provide specific and complementary information about the tagged proteins and their environment. However, none of them taken individually can completely quantify the involved fluorophore characteristics due to their multiparametric dependency with molecular environment, experimental conditions, and interpretation complexity. A solution to get a better understanding of the biological process implied at the cellular level is to combine the spectral and temporal fluorescence data acquired simultaneously at every cell region under investigation. We present the SLiM-SPRC160, an original temporal/spectral acquisition system for simultaneous lifetime measurements in 16 spectral channels directly attached to the descanned port of a confocal microscope with two-photon excitation. It features improved light throughput, enabling low-level excitation and minimum invasivity in living cells studies. To guarantee a fairly good level of accuracy and reproducibility in the measurements of fluorescence lifetime and spectra on living cells, we propose a rigorous protocol for running experiments with this new equipment that preserves cell viability. The usefulness of SLiM approach for the precise determination of overlapping fluorophores is illustrated with the study of known solutions of rhodamine. Then, we describe reliable FRET experiments in imaging mode realized in living cells using this protocol. We also demonstrate the benefit of localized fluorescence spectrum-lifetime acquisitions for the dynamic study of fluorescent proteins. proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号