首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The erbium:yttrium–aluminum–garnet (Er:YAG) laser may be effective the bond strength of adhesive systems on dentine surfaces, the chemical composition and aggressiveness of adhesive systems in clinical practice. The purpose of this study was to evaluate the effects of the Er:YAG laser system with the bonding ability of two different self‐etching adhesives to caries‐affected dentine in primary molars. Ninety mid‐coronal flat dentine surfaces obtained from sound and caries‐affected human primary dentine were treated with an Er:YAG laser or a bur. The prepared surfaces were restored with an adhesive system (Xeno V; Clearfil S3) and a compomer (Dyract Extra). The restored teeth were sectioned with a low‐speed saw and 162 samples were obtained. The bond strength of the adhesive systems was tested using the micro‐tensile test method. The data were statistically analyzed. A restored tooth in each group was processed for scanning electron microscopy evaluation. The values of the highest bond strength were obtained from the Clearfil S3‐Er:YAG laser‐sound dentine group in all groups. (24.57 ± 7.27 MPa) (P > 0.05). The values of the lowest bond strength were obtained from the Xeno V‐Er:YAG laser‐sound dentine group in all groups (11.01 ± 3.89 MPa). It was determined that the Clearfil S3 increased the bond strength on the surface applied with Er:YAG laser according to the Xeno V. Microsc. Res. Tech. 77:282–288, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

2.
The use of Er:YAG laser for cavity preparation: an SEM evaluation   总被引:1,自引:0,他引:1  
OBJECTIVE: The purpose of this study was to evaluate morphological changes in cavities prepared by the Er:YAG laser (2.94 mum) at different parameters of irradiation and by a diamond bur. EXPERIMENTAL DESIGN: Cavities were prepared on 27 human molars (n = 3): G1, 15 Hz/160 mJ enamel/6 Hz/200 mJ dentin; G2, 15 Hz/180 mJ enamel/6 Hz/200 mJ dentin; G3, 15 Hz/160 mJ enamel/6 Hz/250 mJ dentin; G4, 15 Hz/180 mJ enamel/6 Hz/250 mJ dentin; G5, 15 Hz/180 mJ enamel/10 Hz/180 mJ dentin; G6, 15 Hz/160 mJ enamel/10 Hz/180 mJ dentin; G7, 15 Hz/160 mJ enamel/10 Hz/160 mJ dentin; G8, 15 Hz/180 mJ enamel/10 Hz/160 mJ dentin; G9, diamond bur. For SEM analysis, samples were fixed (2.5% glutaraldheyde, 12 h, 4 degrees C), dehydrated (25-100% ethanol), dried, and sputter-coated with gold. RESULTS: Despite the changes on energy and repetition-rate settings, all laser-treated samples showed no evidence of thermal damage or signs of burning and melting. Er:YAG laser ablated dental hard tissues showed exposed enamel prisms, dentin surface without smear layer, and opened dentinal tubules. CONCLUSION: Different Er:YAG laser parameters were effective for ablation of hard tissues, creating an irregular and microretentive morphological pattern without hard tissue damage.  相似文献   

3.
Preservation of enamel during composite veneer restorations of fluorosed teeth could be achieved by conservative preparation with Erbium lasers. This study evaluated the effect of fluorosed enamel preparation with Er,Cr:YSGG vs. conventional diamond bur on the micromorphology and bond strength of a self‐etch and an etch‐and‐rinse adhesives. Er,Cr:YSGG laser or diamond bur preparation was performed on the flattened midbuccal surfaces of 70 extracted human premolars with moderate fluorosis (according to Thylstrup and Fejerskov index, TFI = 4–6). Adper Single Bond (SB) with acid etching for 20 or 40 s and Clearfil SE Bond (SEB) alone or with additional etching was applied in four laser groups. The same adhesive procedures were used in three bur groups except for 40 s of etching along with SB. After restoration, microshear bond strength was measured (MPa). Data were analyzed using ANOVA and Tamhane tests (α = 0.05). Six additional specimens were differently prepared and conditioned for scanning electron microscopy evaluation. The highest and lowest bond strengths were obtained for bur‐prepared/SB (39.5) and laser‐prepared/SEB (16.9), respectively, with a significant difference (P = 0.001). The different adhesive procedures used associated to two adhesives exhibited insignificantly lower bonding in laser‐prepared groups compared to bur‐prepared ones (P > 0.05), with the exception of additional etching/SEB, which bonded significantly higher to bur‐prepared (36.4) than to laser‐prepared enamel (18.7, P = 0.04). Morphological analyses revealed a delicate etch pattern with exposed enamel prisms on laser‐prepared fluorosed enamel after acid etching and less microretentive pattern after self‐etching primer. The etch‐and‐rinse adhesive was preferred in the laser‐prepared fluorosed enamel in terms of bonding performance. Microsc. Res. Tech. 77:779–784, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

4.
The purpose of this study was to analyze, correlate, and compare the demineralization and permeability of dentin remaining after caries removal with either an Er:YAG laser, a bur, or a curette. Thirty human dentin fragments were immersed in a demineralizing solution for 20 days and were randomly divided into three groups (n = 10) for the removal of the demineralized lesion. The groups were G1—Er:YAG laser (200 mJ/6 Hz; noncontact at 12 mm; spot: 0.63 mm), G2—Bur, and G3—Curette. The specimens were then immersed in a 10% copper sulfate solution, then in a 1% dithiooxamide alcoholic solution for 30 min and kept in ammonia vapor for 7 days. Next, the specimens were examined with optical microscopy. The amount of demineralized dentin and the level of copper ion infiltration in the dentin were quantified in μm using Axion Vision software. Data were analyzed with the Kruskal‐Wallis test (p < 0.05) and Pearson's Correlation test. The analysis revealed no significant differences between the three caries removal methods in terms of their capacity to remove demineralized tissue (G1: 10.6 μm; G2: 8.4 μm; G3: 11 μm), although the laser removal generated more tissue permeability than the others methods (G1: 17.6 μm; G2: 6.6 μm; G3: 5.5 μm). The correlation between the remaining demineralized dentin and the dentin permeability was moderate for the conventional methods and higher for the Er:YAG laser. It can therefore be concluded that the laser produced an increase in permeability that was directly proportional to the amount of demineralized tissue removal. Microsc. Res. Tech. 76:225–230, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

5.
The purpose of this in vitro study was to evaluate the interaction pattern of adhesive systems on laser and bur cavities. Cavities were prepared according to the following groups (n=9): (G1) conventional diamond bur (No. 1013); (G2) Er:YAG laser (250 mJ, 4 Hz, 80.6 J/cm2); (G3) Er,Cr:YSGG laser (3.5 W, 20 Hz, 61.7 J/cm2). After cavity preparation, specimens were divided into three subgroups differing the adhesive systems used (n=3): (GA) AdheSE; (GB) Clearfil standard error (SE) Bond; (GC) Single Bond. After insertion of a micro-hybrid composite resin, the specimens were sectioned across the bonded surface dividing the teeth into two halves, which were prepared for SEM analysis. Cavities prepared with laser appeared to be more irregular than the bur cavities. Different patterns of gap formation and resin tags could be observed, showing the differences, advantages, and disadvantages of both types of cavities. Under the settings of the present study, resin tags were more pronounced in lased dentin than bur prepared dentin independently of the bonding systems used. On the other hand gap formation between dentin and resin in laser prepared cavities was observed suggesting collagen alteration.  相似文献   

6.
This study aimed to investigate dentin wettability and surface morphology after selective removal of carious lesion by erbium‐doped yttrium aluminum garnet (Er:YAG) laser, followed by dentin biomodification with carbodiimide (EDC) and chitosan (CHI). Seventy‐eight bovine dentin specimens were submitted to caries induction. Specimens were distributed according to methods of carious removal (n = 39): bur at low‐speed (40,000 rpm) or Er:YAG laser (noncontact mode, 250 mJ/pulse and 4Hz). All specimens were etched with 35% phosphoric acid, and subdivided according to dentin biomodification (n = 13): Control (no biomodification), EDC or CHI. The contact angle (n = 10) between adhesive system (3M ESPE) and dentin surface was measured by a goniometer. Eighteen specimens (n = 3) were analyzed by scanning electron microscopy. Data were analyzed by two‐way ANOVA and Tukey's test (α = .05). The method used to remove carious lesion did not influence the wettability of dentinal surface (p = .748). The angles produced on the remaining dentin after biomodification were influenced (p = .007). CHI promoted higher contact angles (p = .007) and EDC did not differ from the control group (p = .586). In the bur‐treated group, most tubules were open, regardless of which biomodifier was used. Laser modified the organic matrix layer. CHI promoted partially closed tubules in some areas while EDC exposed dentinal tubules. Regardless of which method was used for selective removal of carious lesion, biomodification with EDC did not affect the dentin wettability, whereas CHI changed the wettability of remaining dentin. Both biomodifiers promoted a slight change on dentin morphology.  相似文献   

7.
Previous studies have shown the effects of Er,Cr:YSGG laser irradiation on the dentin bond strength; but there are few reports that show the significance of the irradiation with different laser parameters on dentin bond strength and interface morphology. This in‐vitro study attempted to evaluate the microtensile bond strength (μTBS) and interface morphology of resin‐dentin interfaces, either followed by treatment with Er,Cr:YSGG laser irradiation with different parameters or not. The flattened dentin samples of 35 bovine teeth were embedded into acrylic blocks and randomly divided into seven groups according to surface treatments using Er,Cr:YSGG lasers with different parameters: 3 W/20 Hz, 3 W/35 Hz, 3 W/50 Hz, 1.5 W/20 Hz, 1.5 W/35 Hz, 1.5 W/50 Hz, or no laser treatment (n = 5). Composite buildups were done over bonded surfaces and stored in water (24 hours at 37°C). Specimens were sectioned into sticks that were subjected to μTBS testing and observed under FE‐SEM. Control groups (27.70 ± 7.0) showed statistically higher values than laser‐irradiated groups. There were no significant differences among laser groups. Despite that, increasing the pulse frequency yielded slightly higher bond strength. Depending on laser settings, Er,Cr:YSGG laser irradiation caused interfacial gaps and resin tags with wings morphology. With the parameters used in this study, Er,Cr:YSGG laser irradiation promoted morphological changes within resin‐dentin interfaces and negatively influenced the bond strength of adhesive systems. Microsc. Res. Tech. 78:1104–1111, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

8.
Dentin irradiation with erbium lasers has been reported to alter the composite resin bond to this treated surface. There is still a lack of studies reporting the effect of erbium lasers on dentin organic content and elucidating how laser treatment could interfere in the quality of the resin-dentin interface. This study aimed to evaluate the effect of erbium laser irradiation on dentin morphology and microtensile bond strength (μTBS) of an adhesive to dentin. Seventy-two dentin disks were divided into nine groups (n = 8): G1-Control (600-grit SiC paper); Er:YAG groups: G2- 250 mJ/4 Hz; G3- 200 mJ/4 Hz; G4- 180 mJ/10 Hz; G5- 160 mJ/10 Hz; Er,Cr:YSGG groups: G6- 2 W/20 Hz; G7- 2.5 W/20 Hz; G8- 3 W/20 Hz; G9- 4 W/20 Hz. Specimens were processed for cross-sectional analysis by scanning electron microscopy (SEM) (n = 3), transmission electron microscopy (TEM) (n = 2), and adhesive interface (n = 3). Forty-five dentin samples (n = 5) were restored and submitted to μTBS testing. ANOVA (α = 5%) revealed that G1 presented the highest μTBS values and irradiated groups did not differ from each other. TEM micrographs showed a superficial layer of denatured collagen fibrils. For SEM micrographs, it was possible to verify the laser effects extending to dentin subsurface presenting a rough aspect. Cross-sectional dentin micrographs of this hybridized surface revealed a pattern of modified tags with ringlike structures around it. This in vitro study showed that erbium laser irradiation interacts with the dental hard tissue resulting in a specific morphological pattern of dentin and collagen fibrils that negatively affected the bond strength to composite resin.  相似文献   

9.
The aim of the study was to evaluate the adhesion of a self‐adhering flowable composite resin to primary tooth enamel and dentin after silicon carbide paper (SiC) and laser pretreatment. Adhesive properties were evaluated as shear bond strength (SBS) and scanning electron microscopic (SEM) characteristics. A total 120 primary canine teeth were randomly divided into two groups to study enamel and dentin. Each group was divided into 6 subgroups (n = 10) according to type of surface preparation (SiC or Er:YAG laser) of enamel or dentin. Three methods were used to build cylinders of restoration on tooth surface: OptiBond All‐In‐One + Premise Flowable composite, OptiBond All‐In‐One + Vertise Flow and Vertise flow. After restoration, samples were tested for SBS and failure mode. Twenty eight samples were examined by SEM. The results of the study showed SBS of Vertise Flow was lower than others in enamel and dentin samples pretreated with SiC and in dentin samples pretreated with laser (P < 0.001). Compared to SiC pretreatment, laser pretreatment led to a significantly higher SBS with Vertise Flow on enamel (P < 0.001). Vertise Flow associated with the adhesive led to a higher SBS in enamel and dentin compared to Vertise Flow alone. Adhesive and mixed failure modes were observed more frequently in Vertise Flow groups. SEM images showed that Vertise Flow led to more irregularities on enamel and more open dentinal tubules after laser ablation compared SiC pretreatment. Microsc. Res. Tech. 79:334–341, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

10.
The purpose of this study was to compare total‐etch, self‐etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group‐1: bur preparation(bp)+Adper Single Bond 2 (ASB)+Filtek Z550 (FZ); Group‐2: laser preparation(lp)+(ASB)+(FZ); Group‐3: bp + Clearfil S3 Bond Plus (CSBP)+(FZ); Group‐4: lp+(CSBP) (FZ); Group‐5: bp + acid etching+(CSBP)+(FZ); Group‐6: lp + acid etching+(CSBP)+(FZ). All teeth were stored in distilled water at 37°C for 24 hr, and then thermocycled 1000 times (5–55°C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in the cervical regions compared to the occlusal regions in Groups 3, 5, and 6, respectively (p < .05). There is no statistically significant difference in Groups 1, 2, and 4, in terms of cervical regions versus occlusal regions (p > .05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p > .05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er:YAG laser and bur.  相似文献   

11.
The study aimed to evaluate the effect of different output powers of Er:YAG laser on microtensile bonding strength of indirect composite to resin cements.36 indirect composite blocks (GC Gradia DA2, Japan) size 15 × 10 × 10 mm3 were constructed, and divided into 12 groups, as follows:G1: control group (no treatment); Groups G2 to G6: treated with Er:YAG laser (2,940 nm) in noncontact mode, frequency 20 Hz, pulse duration 470 µs, with output power ranging from 2W to 6W; Groups G7 sandblasting, Groups 8 to G12: as Groups G2 to G 6 with preparatory sandblasting. One specimen from each group was analyzed by SEM; each specimen was fixed to a specialized metal jig using cyanoacrylate (Mitreapel, Beta Kimya San. Ve TIC, Iran) and debonded under tension with a universal testing machine (Zwick, Germany) at a crosshead speed of 0.5 mm min?1. Sandblasting and laser can improve bond strength above an energy level of 150 mJ. SEM evaluation of laser‐treated specimens showed irregularities and deep undercuts. T test analysis showed no significant difference between sandblasted and non‐sandblasted group, with laser output power of 0, 100, or 150 mJ (P = 0.666, P = 0.875, and P = 0.069); in the specimens irradiated with energy output of 200, 250, or 300 mJ, sandblasted specimens showed higher bond strength than non‐sandblasted ones. The results demonstrate that, in composite resin irradiated with laser at energy output of 200–300 mJ, sandblasting might be a suitable procedure to enhance bond strength of resin cement. Microsc. Res. Tech. 79:328–333, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

12.
This study reports the effects on micromorphology and temperature rise in human dentin using different frequencies of Er:YAG laser. Sixty human dentin fragments were randomly assigned into two groups (n = 30): carious or sound dentin. Both groups were divided into three subgroups (n = 10), according to the Er:YAG laser frequency used: 4, 6, or 10 Hz (energy: 200 mJ; irradiation distance: 12 mm; and irradiation time: 20 s). A thermocouple adapted to the tooth fragment recorded the initial temperature value (°C); then, the temperature was measured after the end of the irradiation (20 s). Morphological analysis was performed using images obtained with scanning electron microscope. There was no difference between the temperatures obtained with 4 and 6 Hz; the highest temperatures were achieved with 10 Hz. No difference was observed between carious and sound dentin. Morphological analyses revealed that all frequencies promoted irregular surface in sound dentin, being observed more selectively ablation especially in intertubular dentin with tubule protrusion. The caries dentin presented flat surface for all frequencies used. Both substrates revealed absence of any signs of thermal damage. It may be concluded that the parameters used in this study are capable to remove caries lesion, having acceptable limits of temperature rise and no significant morphological alterations on dentin surface. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

13.
Universal adhesives have been recently introduced for use as self‐etch or etch‐and‐rinse adhesives depending on the dental substrate and clinical condition. However, their bonding effectiveness to laser‐irradiated enamel is still not well‐known. Thus, the aim of this study was to compare the shear bond strength (SBS) of universal adhesives (Single Bond Universal; Nova Compo‐B Plus) applied to Er,Cr:YSGG laser‐irradiated enamel with SBS of the same adhesives applied in self‐etch and acid‐etching modes, respectively. Crown segments of sixty bovine incisors were embedded into standardized acrylic blocks. Flattened enamel surfaces were prepared. Specimens were divided into six groups according to universal adhesives and application modes randomly (n = 10), as follows: Single Bond Universal/acid‐etching mode; Nova Compo‐B Plus/acid‐etching mode; Single Bond Universal/self‐etching mode; Nova Compo‐B Plus/self‐etching mode; and Single Bond Universal/Er,Cr:YSGG Laser‐etching mode; Nova Compo‐B Plus/Er,Cr:YSGG Laser‐etching mode. After surface treatments, universal adhesives were applied onto surfaces. SBS was determined after storage in water for 24 h using a universal testing machine with a crosshead speed of 0.5 mm min?1. Failure modes were evaluated using a stereomicroscope. Data was analyzed using two‐way of analyses of variances (ANOVA) (p = 0.05). Two‐way ANOVA revealed that adhesive had no effect on SBS (p = 0.88), but application mode significantly influenced SBS (p = 0.00). Acid‐etching significantly increased SBS, whereas there are no significant differences between self‐etch mode and laser‐etching for both adhesives. The bond strength of universal adhesives may depend on application mode. Acid etching may significantly increase bond strength, while laser etching may provide similar bond strength when compared to self‐etch mode.  相似文献   

14.
The purpose of this study was to evaluate the efficiency of the Er:YAG laser and diamond bur cavity preparation on the marginal microleakage of Class V cavities. Group 1: bur preparation (bp) + Vertise Flow (VF); Group 2: laser preparation (lp) + VF; Group 3: bp + Adper Easy One (AEO) + Filtek Ultimate Flowable Composite (FUFC); Group 4: lp + AEO + FUFC; Group 5: bp + Clearfil S3 Bond (CSB) + Clearfil Majesty Flow (CMF); Group 6: lp + CSB + CMF. Data were analyzed by Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in cervical regions compared to occlusal regions in all groups (p < .05). No significant difference was observed among all groups in terms of occlusal and cervical surfaces, respectively (p > .05). The use of the Er:YAG laser for cavity preparation with different adhesive systems and flowable composites did not influence microleakage.  相似文献   

15.
This study evaluated the shear bond strength (SBS) and internal marginal adaptation of pulp‐capping materials to dentin. Flat occlusal deep dentin surfaces were produced and randomly assigned to two groups (sound or artificial caries‐affected dentin). The specimens in each group were assigned to one of seven subgroups according to the materials used: Biodentine, Theracal LC, Ultra‐Blend plus, Calcimol LC, ApaCal ART, EQUIA Forte, and Ionoseal. Buildups (3‐mm inner diameter and 2‐mm deep) were made over the dentin surfaces. The bonded specimens were tested under shear forces at a crosshead speed of 0.8 mm/min and fracture modes were determined using a stereomicroscope at 25× magnification. The materials were applied to the pulp floor of prepared Class I cavities and then the cavities were restored with composite resin. Restored molar teeth were subjected to 5,000 thermocycles and sectioned in a bucco–lingual direction. Resin replicas were made to determine the adaptation at the pulp floor with scanning electron microscopy. Significant differences were determined among both bond strengths and gap formations of the materials. EQUIA Forte applied to both dentin substrates had a significantly higher SBS than the other materials. The bond strength of each material was not influenced by the dentin condition. Biodentine (3.03%), EQUIA Forte (7.83%), and Theracal LC (13.37%) had lower gap formations compared to other materials but were not significantly different from each other.  相似文献   

16.
Oxalate‐based products are effective against dentine sensitivity and have been studied as an option to improve long‐term adhesive bonding strength. Our aim was to evaluate the effect of potassium oxalate on the microtensile bond strength (µTBS) of the dentin/resin interface after 24 h, 1, and 6 years. Dentin on the occlusal surface of 16 human premolars was exposed and etched with 35% phosphoric acid. The teeth were divided into four groups. Two groups received 3% monohydrated potassium oxalate and the following adhesive systems and composites: Adper Scotchbond Multipurpose + FiltekZ350 (3M/ESPE) and Prime & Bond NT + Esthet‐X (Dentsply). Two control groups did not receive potassium oxalate. Teeth were cut into sticks and kept in distilled water at 37°C for 24 h, 1, and 6 years. The sticks underwent µTBS testing after storage. ANOVA, Tukey's post hoc test, and paired t test were used to compare storage times (α = 0.05). The fracture mode of the specimens was classified under a stereomicroscope (40×). Morphology of the hybrid layer and the fracture pattern were observed with scanning electronic microscopy (SEM). Mean µTBS was high at 24 h and decreased after 1 and 6 years. After 6 years, the mean µTBS values were similar with no statistically significant difference between the groups (p = .121). SEM images showed proper dentin hybridization. Dentin pretreatment with potassium oxalate did not affect hybrid layer formation, but bond strength decreased over time after 24 h. Therefore, the clinical use of potassium oxalate to increase dentin bond durability is not indicated.  相似文献   

17.
This study evaluated the effects of an antioxidant application on the compromised bond strength of an adhesive to dentin bleached with 35% hydrogen peroxide. The dentin surfaces of the pulp chambers of 70 human third molars were ground, and the specimens were assigned randomly into seven groups, as follows: (a) control (unbleached); (b) bleached for 45 min, bonded immediately; (c) bleached for 45 min, treated with sodium ascorbate (SA) for 2 min, and bonded; (d) bleached for 45 min, bonded after 2 weeks; (e) bleached for 12 days, bonded immediately; (f) bleached for 12 days, treated with SA for 10 min, and bonded; and (g) bleached for 12 days, bonded after 2 weeks. In each group, the multimode adhesive was applied in etch‐and‐rinse and self‐etch modes. The dentin surfaces were covered with a resin‐based composite, and the bonded specimens were sectioned to produce composite–dentin sticks. The sticks were attached to a testing machine and subjected to a tensile force, and the representative specimens were examined via scanning electron microscopy. The bond strength was not affected by the application period of the bleaching agent. Both bleaching treatments significantly reduced the bond strength to the dentin in the self‐etch or etch‐and‐rinse mode when compared with the control group. The bond strengths returned to normal levels with the SA applications or by waiting 2 weeks, regardless of the application period of the bleaching gel. The adhesive revealed a higher bond strength in the etch‐and‐rinse mode than in the self‐etch mode.  相似文献   

18.
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1‐etch‐and‐rinse mode with phosphoric acid; Group 2‐etch‐and‐rinse mode with Er,Cr:YSGG laser; Group 3‐selective‐etch mode with phosphoric acid; Group 4‐selective‐etch mode with Er,Cr:YSGG laser; Group 5‐self‐etch. After restorations were performed with a resin composite, Tetric N‐Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth‐resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal–Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.  相似文献   

19.
The morphological and chemical changes in deciduous dentin produced by different conditioning protocols were evaluated in this in vitro study. Eighty primary dentin samples were divided into eight groups (n = 10): G1, acid etching; G2, self‐etching adhesive; G3, G4, Er: YAG laser irradiation at 25.5 and 38.2 J cm?2, respectively; 10 Hz and spray irrigation. Groups 5, 6, 7, and 8 were irradiated at previous densities, and then phosphoric acid or self‐etching adhesive conditioning was applied. Scanning electron microscopy (SEM) and energy dispersive X‐ray spectroscopy (EDS) were used to evaluate chemical and morphological changes. Paired t‐test and One‐way ANOVA were used for statistical analysis (p ≤ 0.05). All samples showed different morphology with specific characteristics according to the conditioning protocol. Changing element concentration values are expressed in atomic percent (at %). After conditioning, there were statistically significant differences (p ≤ 0.05) for p at% and Ca/P in all groups; highlighting the following additional findings by group: G1, G7, and G8 showed changes in all elements studied, G2 presented a decrease in C at% and increased Ca at%, G3 and G4 exhibited at% changes in C, trace elements and Ca. Furthermore, G5 showed at% changes in O and trace elements; while G6 changes were observed on C at%, O at% and trace elements at%. Dentin morphology and chemical composition varied in accordance with the conditioning protocol, with characteristics specific for each one that could have clinical implications for the retention and bond strength performance of adhesive materials.  相似文献   

20.
This study evaluated the effect of Er,Cr:YSGG laser on the root canal dentin after luting a fiber post. Twenty‐four bovine teeth roots were prepared using NiTi instruments and filled with Sealer 26 and gutta‐percha. Post spaces were prepared and roots were distributed according to dentin treatment (n = 8): 2.5%NaOCl (group control), Er,Cr:YSGG laser (1.5 W, 20 Hz, 20 s) (group test 1) or 2.5%NaOCl + Er,Cr:YSGG laser (group test 2). Fiber posts were luted using adhesive cement (Rely X U200, 3M) and roots were prepared to confocal laser scanning microscopy (CLSM) and scanning electron microscope (SEM). The morphology of interface, thickness of cement, and the gaps and tags were analyzed. Non‐parametrical data for thickness of cement were submitted to Friedman and Kruskall–Wallis tests (α = 0.05) and parametrical data for gaps to ANOVA (α = 0.05). CLSM of the cement thickness and gaps revealed no significant difference in surface treatment (NaOCl, Er,Cr:YSGG laser and NaOCl + Er,Cr:YSGG laser) (p > .05) and canal thirds (cervical, middle, and apical) (p > 0.05). SEM showed tags and a residual layer of cement adhered to dentin, mainly in laser‐irradiated specimens. The pretreatment of root canal with Er,Cr:YSGG laser previously to luting the fiber post with a self‐adhesive cement did not influence the cement thickness and gaps but affected the dentin interaction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号