首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Universal adhesives have been recently introduced for use as self‐etch or etch‐and‐rinse adhesives depending on the dental substrate and clinical condition. However, their bonding effectiveness to laser‐irradiated enamel is still not well‐known. Thus, the aim of this study was to compare the shear bond strength (SBS) of universal adhesives (Single Bond Universal; Nova Compo‐B Plus) applied to Er,Cr:YSGG laser‐irradiated enamel with SBS of the same adhesives applied in self‐etch and acid‐etching modes, respectively. Crown segments of sixty bovine incisors were embedded into standardized acrylic blocks. Flattened enamel surfaces were prepared. Specimens were divided into six groups according to universal adhesives and application modes randomly (n = 10), as follows: Single Bond Universal/acid‐etching mode; Nova Compo‐B Plus/acid‐etching mode; Single Bond Universal/self‐etching mode; Nova Compo‐B Plus/self‐etching mode; and Single Bond Universal/Er,Cr:YSGG Laser‐etching mode; Nova Compo‐B Plus/Er,Cr:YSGG Laser‐etching mode. After surface treatments, universal adhesives were applied onto surfaces. SBS was determined after storage in water for 24 h using a universal testing machine with a crosshead speed of 0.5 mm min?1. Failure modes were evaluated using a stereomicroscope. Data was analyzed using two‐way of analyses of variances (ANOVA) (p = 0.05). Two‐way ANOVA revealed that adhesive had no effect on SBS (p = 0.88), but application mode significantly influenced SBS (p = 0.00). Acid‐etching significantly increased SBS, whereas there are no significant differences between self‐etch mode and laser‐etching for both adhesives. The bond strength of universal adhesives may depend on application mode. Acid etching may significantly increase bond strength, while laser etching may provide similar bond strength when compared to self‐etch mode.  相似文献   

2.
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1‐etch‐and‐rinse mode with phosphoric acid; Group 2‐etch‐and‐rinse mode with Er,Cr:YSGG laser; Group 3‐selective‐etch mode with phosphoric acid; Group 4‐selective‐etch mode with Er,Cr:YSGG laser; Group 5‐self‐etch. After restorations were performed with a resin composite, Tetric N‐Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth‐resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal–Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.  相似文献   

3.
The purpose of this study was to compare total‐etch, self‐etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group‐1: bur preparation(bp)+Adper Single Bond 2 (ASB)+Filtek Z550 (FZ); Group‐2: laser preparation(lp)+(ASB)+(FZ); Group‐3: bp + Clearfil S3 Bond Plus (CSBP)+(FZ); Group‐4: lp+(CSBP) (FZ); Group‐5: bp + acid etching+(CSBP)+(FZ); Group‐6: lp + acid etching+(CSBP)+(FZ). All teeth were stored in distilled water at 37°C for 24 hr, and then thermocycled 1000 times (5–55°C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in the cervical regions compared to the occlusal regions in Groups 3, 5, and 6, respectively (p < .05). There is no statistically significant difference in Groups 1, 2, and 4, in terms of cervical regions versus occlusal regions (p > .05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p > .05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er:YAG laser and bur.  相似文献   

4.
The aim of this study was to evaluate gap formation after using two universal adhesives, Peak Universal Bond (P), which contains chlorhexidine and Adhese Universal (A), which contains 10‐MDP monomer, and to compare them with two gold standard adhesives. The adhesives were tested in different etching modes, etch‐and‐rinse (ER) or self‐etch (SE), and under thermomechanical loading (TML). Two identical Class V cavities were prepared in each of 30 human third molar teeth, and resin‐composite restorations were made. Before and after TML, replicas of the restorations were prepared. Gap formation and their frequency according to the modified classification of Blunck and Zaslansky and the width of the maximum marginal gap (MG) were separately evaluated in enamel and dentin. Gap frequency did not differ significantly only in the enamel before TML, despite the use of different adhesives or etching modes. At both timepoints, the highest MG values were obtained with the Peak Universal Bond self‐etch (PSE) group in enamel (6.2 μm before TML, 12.2 μm after TML) and the Peak Universal Bond etch‐and‐rinse (PER) group in dentine (21.3 μm before TML, 35.5 μm after TML). After TML, there was a significant increase of gap frequency for Adhese universal self‐etch (ASE) group and MG values for PER, PSE, ASE groups at the resin‐enamel interface, and gap frequency and MG values for all groups at the resin‐dentin interface. Universal adhesive with 10‐MDP monomer have beneficial effect on the resin‐dentin interface, while chlorhexidine may reduce the resistance of the universal adhesive system to oral cavity conditions.  相似文献   

5.
Aim: Evaluate the composite‐to‐enamel bond after passive or active application of self‐etching primer systems on polished or pre‐etched enamel with phosphoric acid. Materials and Methods: Two self‐etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric‐acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three‐way ANOVA and the Tukey test. The enamel‐etching pattern was evaluated under SEM. Results: The 2‐step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1‐step (36.87 MPa). A poor enamel‐ etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. Conclusion: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.  相似文献   

6.
The erbium:yttrium–aluminum–garnet (Er:YAG) laser may be effective the bond strength of adhesive systems on dentine surfaces, the chemical composition and aggressiveness of adhesive systems in clinical practice. The purpose of this study was to evaluate the effects of the Er:YAG laser system with the bonding ability of two different self‐etching adhesives to caries‐affected dentine in primary molars. Ninety mid‐coronal flat dentine surfaces obtained from sound and caries‐affected human primary dentine were treated with an Er:YAG laser or a bur. The prepared surfaces were restored with an adhesive system (Xeno V; Clearfil S3) and a compomer (Dyract Extra). The restored teeth were sectioned with a low‐speed saw and 162 samples were obtained. The bond strength of the adhesive systems was tested using the micro‐tensile test method. The data were statistically analyzed. A restored tooth in each group was processed for scanning electron microscopy evaluation. The values of the highest bond strength were obtained from the Clearfil S3‐Er:YAG laser‐sound dentine group in all groups. (24.57 ± 7.27 MPa) (P > 0.05). The values of the lowest bond strength were obtained from the Xeno V‐Er:YAG laser‐sound dentine group in all groups (11.01 ± 3.89 MPa). It was determined that the Clearfil S3 increased the bond strength on the surface applied with Er:YAG laser according to the Xeno V. Microsc. Res. Tech. 77:282–288, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

7.
The purpose of this in vitro study was to evaluate the interaction pattern of adhesive systems on laser and bur cavities. Cavities were prepared according to the following groups (n=9): (G1) conventional diamond bur (No. 1013); (G2) Er:YAG laser (250 mJ, 4 Hz, 80.6 J/cm2); (G3) Er,Cr:YSGG laser (3.5 W, 20 Hz, 61.7 J/cm2). After cavity preparation, specimens were divided into three subgroups differing the adhesive systems used (n=3): (GA) AdheSE; (GB) Clearfil standard error (SE) Bond; (GC) Single Bond. After insertion of a micro-hybrid composite resin, the specimens were sectioned across the bonded surface dividing the teeth into two halves, which were prepared for SEM analysis. Cavities prepared with laser appeared to be more irregular than the bur cavities. Different patterns of gap formation and resin tags could be observed, showing the differences, advantages, and disadvantages of both types of cavities. Under the settings of the present study, resin tags were more pronounced in lased dentin than bur prepared dentin independently of the bonding systems used. On the other hand gap formation between dentin and resin in laser prepared cavities was observed suggesting collagen alteration.  相似文献   

8.
This study evaluates the bond strength of dentin prepared with Er:YAG laser or bur, after rewetting with chlorhexidine on long‐term artificial saliva storage and thermocycling. One hundred and twenty human third molars were sectioned in order to expose the dentin surface (n = 10). The specimens were randomly divided in 12 groups according to treatment and aging: Er:YAG laser rewetting with deionized water (LW) and 24 h storage in artificial saliva (WC); LW and 6 months of artificial saliva storage + 12.000 thermocycling (6M), LW and 12 months of artificial saliva storage + 24.000 thermocycling (12M), Er:YAG laser rewetting with 2% chlorhexidine (LC) and WC, LC and 6M, LC and 12M, bur on high‐speed turbine rewetting with deionized water (TW) and WC, TW6M, TW12M, bur on high‐speed turbine + 2% chlorhexidine (TC) and WC, TC and 6M, TC and12M. The specimens were etched with 35% phosphoric acid, washed, and dried with air. Single Bond 2 adhesive was applied and the samples were restored with a composite. Each tooth was sectioned in order to obtain 4 sticks, which were submitted to microtensile bond strength test (µTBS). The two‐way ANOVA, showed no significant differences for the interaction between the factors and for the aging factor. Tukey 5% showed that the LC group had the lowest µTBS. The rewetting with chlorhexidine negatively influenced the bond strength of the preparation with the Er:YAG laser. The artificial saliva aging and thermocycling did not interfere with dentin bond strength. Microsc. Res. Tech. 77:37–43, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

9.
The purpose of this study was to comparatively evaluate the effects of different caries removal methods on microleakage success of class V adhesive restorations by means of light microscopy (stereomicroscope) and scanning electron microscopy (SEM) observations. Sixty‐four human teeth with class V caries that measured with DIAGNOdent were used. The samples were divided into four groups (n = 16) randomly according to caries removing methods of conventional method, Carisolv, Papacarie, and Er,Cr:YSGG laser system. The self‐etch Clearf?l SE Bond and Clearf?l Majesty Es‐II were used as restoration materials. After thermal cycles of 2,000 (5 and 55°C) samples were immersed in a 50% wt/wt AgNO3. Samples were finally imaged and scored under light microscopy and SEM, respectively. The data were statistically analyzed using Kruskal–Wallis H, pairwise comparison and Wilcoxon's T tests at 5% significance level (p < .05). Statistical analysis demonstrated that there was no significant difference between microleakage scores in dentin regions but there were significant difference between the Papacarie and Er,Cr:YSGGlaser in terms of leakage scores in enamel sites. No statistically significant difference in leakage scores emerged between light microscopy and SEM.  相似文献   

10.
This study evaluated the effect of 10% sodium hypochlorite (NaOCl) as deproteinizing agent and storage media on bond strength (BS) of two etch‐and‐rinse adhesive systems to dentin. Twenty‐eight sound extracted human third molars were divided in four groups (n = 7), according to dentin treatment (conventional etching or etching followed by 10% NaOCl application) and adhesive systems (GB—Gluma 2Bond and OS—One‐Step). After dentin treatments and adhesive application, a composite block was built‐up on dentin surface and teeth were serially sectioned to obtain bonded sticks specimens. The sticks were submitted to three aging conditions: (24H) 24 hr in water (immediate), (SH) 3 hr of NaOCl accelerated‐aging or (1Y) 1 year of water storage. Afterward, submitted to microtensile bond strength test (μTBS), failure modes and adhesive interfaces analyzes. Data were analyzed by two‐way analysis of variance (ANOVA) and Tukey's test (α = .05). Dentin deproteinization before bonding significantly reduced μTBS for GB‐treated group (p < .05), regardless the aging conditions. Water storage for 1 year (1Y) and NaOCl accelerated‐aging (SH) decreased μTBS for both adhesives. Yet, the groups stored in NaOCl (SH) exhibited the lowest BS results (p < .05). Bond strength of deproteinized dentin was dependent on the adhesive system composition and NaOCl accelerated‐aging promoted decreased bond strength and further degradation than water storage for 1 year.  相似文献   

11.
Purpose: The aim of this study was to evaluate the nanoleakage patterns between dental enamel and reinforced leucite ceramic, bonded with resin luting systems and a flowable composite resin. Materials and Methods: Twelve crowns of bovine incisors were randomly divided into four groups (n = 3) according to the luting procedure: Excite/Variolink II, Clearfil SE Bond/Panavia F, Scotchbond Multi‐Purpose Plus/RelyX ARC, and Single Bond 2/Filtek Z350 Flow. To evaluate the nanoleakage patterns, IPS Empress Esthetic disks (5 mm Ø and 1.2‐mm thick) were bonded to enamel, and, after 24 h, the specimens were immersed in a 50% (w/v) solution of silver nitrate (24 h), fixed, dehydrated, and processed scanning electron microscopy (SEM). Results: None nanoleakage on interface of the groups that Single Bond 2 followed by the flowable composite were used. The highest percentage of nanoleakage was shown by the Excite/Variolink II protocol. Also, in all conditions tested, none silver nitrate uptake was observed between the leucite‐reinforced ceramic and the resin luting cement. Conclusions: The use of a two‐step etch‐and‐rinse adhesive with flowable composite was able to promote an adequate seal of the bond interface at the enamel. Moreover, the conventional dual‐cured resin cements associated with simplified and dual‐cured adhesives tested are also indicated to bond thin ceramics to enamel, since all presented low silver nitrate uptake. Microsc. Res. Tech., 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

12.
This study evaluated the effect of Er,Cr:YSGG laser on the root canal dentin after luting a fiber post. Twenty‐four bovine teeth roots were prepared using NiTi instruments and filled with Sealer 26 and gutta‐percha. Post spaces were prepared and roots were distributed according to dentin treatment (n = 8): 2.5%NaOCl (group control), Er,Cr:YSGG laser (1.5 W, 20 Hz, 20 s) (group test 1) or 2.5%NaOCl + Er,Cr:YSGG laser (group test 2). Fiber posts were luted using adhesive cement (Rely X U200, 3M) and roots were prepared to confocal laser scanning microscopy (CLSM) and scanning electron microscope (SEM). The morphology of interface, thickness of cement, and the gaps and tags were analyzed. Non‐parametrical data for thickness of cement were submitted to Friedman and Kruskall–Wallis tests (α = 0.05) and parametrical data for gaps to ANOVA (α = 0.05). CLSM of the cement thickness and gaps revealed no significant difference in surface treatment (NaOCl, Er,Cr:YSGG laser and NaOCl + Er,Cr:YSGG laser) (p > .05) and canal thirds (cervical, middle, and apical) (p > 0.05). SEM showed tags and a residual layer of cement adhered to dentin, mainly in laser‐irradiated specimens. The pretreatment of root canal with Er,Cr:YSGG laser previously to luting the fiber post with a self‐adhesive cement did not influence the cement thickness and gaps but affected the dentin interaction.  相似文献   

13.
The purpose of this study was to: (a) evaluate the role of enamel surface roughness on bond fatigue durability and (b) evaluate statistical differences in roughness values based on measurement technique, including the use of spatial filtering for optical profilometry (OP). OptiBond XTR (Kerr Corp), Prime & Bond elect (DENTSPLY Caulk), Scotchbond Universal (3 M Oral Care), and XTR pre‐etched with Ultra‐Etch phosphoric acid (35%) (Ultradent) self‐etch adhesives were used to treat enamel. A flat ground enamel surface was included as a control. Atomic force microscopy (AFM) and OP were used to measure the surface topography of each enamel surface following the application of adhesives. AFM, OP, and filtered OP (FOP) roughness values, where FOP was designed to only include the lateral spatial resolution consistent with AFM roughness values, were collected. Spatial resolution filtering with OriginPro was used to compare line scans from the two imaging techniques and generate the FOP group. These micro‐ versus nanoscale lateral roughness values were correlated with shear bond and shear fatigue strengths of the adhesives bonded to enamel. Roughness values showed differences based on measurement technique and strong correlations with bond and fatigue strength. The filtered OP group demonstrated the importance of careful usage and reporting of atomic force microscopy and OP metrics in adhesive dentistry. Best practices for surface roughness analysis were also discussed.  相似文献   

14.
This study evaluates the bond strength of four self‐etching adhesive systems with different acidity levels in normal and artificially hypermineralized dentin substrate. Healthy human molars were divided into groups: normal dentin—N (n = 36) and artificially hypermineralized dentin—H (n = 36). Self‐etching adhesive systems Clearfil S3 Bond (n = 9), Optibond All in One (n = 9), Clearfil SE Bond (n = 9), and Adhese (n = 9) were used for both the N and H groups. Transparent cylindrical matrices were positioned on the treated dentin surfaces, filled with composite resin, and light‐cured for 40 s. After the transparent cylindrical matrices were removed, the specimens were stored for 24 hr in a humid environment at 37°C and were subjected to a micro‐shear bond strength test. For each group, a specimen was prepared and evaluated in scanning electron microscope for adhesive interface observation. Normality was confirmed and the two‐way analysis of variance and Games–Howell post‐tests were conducted (α = .05). The data demonstrated an interaction between the adhesive system and type of dentin substrate (p < .01). For normal dentin, all adhesive systems assessed were adequate; however, in the hypermineralized dentin, the Clearfil SE Bond two‐step self‐etching adhesive system with mild pH presented the highest immediate bond strength. There was a predominance of adhesive failures for all adhesive systems in the different dentin substrates evaluated. It was concluded that the self‐etching adhesive systems evaluated were efficient for both substrates, and for the hypermineralized dentin, the Clearfil SE Bond presented a higher bond strength value.  相似文献   

15.
Background: It remains unclear as to whether or not dental bleaching affects the bond strength of dentin/resin restoration. Purpose: To evaluated the bond strength of adhesive systems to dentin submitted to bleaching with 38% hydrogen peroxide (HP) activated by LED‐laser and to assess the adhesive/dentin interfaces by means of SEM. Study design: Sixty fragments of dentin (25 mm2) were included and divided into two groups: bleached and unbleached. HP was applied for 20 s and photoactivated for 45 s. Groups were subdivided according to the adhesive systems (n = 10): (1) two‐steps conventional system (Adper Single Bond), (2) two‐steps self‐etching system (Clearfil standard error (SE) Bond), and (3) one‐step self‐etching system (Prompt L‐Pop). The specimens received the Z250 resin and, after 24 h, were submitted to the bond strength test. Additional 30 dentin fragments (n = 5) received the same surface treatments and were prepared for SEM. Data were analyzed by ANOVA and Tukey's test (α = 0.05). Results: There was significant strength reduction in bleached group when compared to unbleached group (P < 0.05). Higher bond strength was observed for Prompt. Single Bond and Clearfil presented the smallest values when used in bleached dentin. SEM analysis of the unbleached specimens revealed long tags and uniform hybrid layer for all adhesives. In bleached dentin, Single Bond provided open tubules and with few tags, Clearfil determined the absence of tags and hybrid layer, and Prompt promoted a regular hybrid layer with some tags. Conclusions: Prompt promoted higher shear bond strength, regardless of the bleaching treatment and allowed the formation of a regular and fine hybrid layer with less deep tags, when compared to Single Bond and Clearfil. Microsc. Res. Tech., 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

16.
OBJECTIVES: To compare microleakage of three self‐etch adhesives and to analyze enamel surface morphology and interfacial morphology of resin–enamel and resin–dentin interface under scanning electron microscope (SEM). EXPERIMENTAL DESIGN: Study was conducted in 65 extracted human premolars. Class V cavities were prepared in 45 teeth and assigned to three groups (n = 15) according to three self‐etch adhesives (OptiBond All‐in‐One, iBond, and Adper Prompt L‐Pop). After restoration, 10 samples from each group were used to assess microleakage at enamel and dentin margin. Five samples from each group were used for analysis of interfacial morphology at resin–enamel and resin–dentin interface under SEM. Remaining 20 teeth were used to prepare flat enamel buccal surfaces to analyze the difference in surface morphology after treatment with three adhesives (n = 5 each) and 36% phosphoric acid treatment (n = 5). PRINCIPAL OBSERVATIONS: At enamel margin, Prompt L‐Pop depicted least leakage of all the three adhesives and also showed best interfacial adaptation under SEM. At dentin margin, OptiBond All‐in‐One showed significant less leakage than iBond and Prompt L‐Pop. On flat enamel surface, phosphoric acid produced the most retentive etching pattern when compared with the three adhesives. CONCLUSION: Prompt L‐Pop showed the best bonding effectiveness in enamel, whereas OptiBond All‐in‐One performed significantly better in dentin. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
Aim: To evaluate and compare the effect of double‐application of single‐step self‐etch adhesives using microleakage study and to analyze the dentin–adhesive interfacial micromorphology. Methods: In total, 72 extracted human premolars were divided into three groups for different self‐etch adhesives (G Bond, GC [GB], Optibond, Kerr [OB], and Xeno V Plus, Dentsply [XV]). Class V cavities were prepared. Each group was further divided into two subgroups (n = 10) according to the placement technique of the adhesive, using the single‐application [subgroup (a)] or double‐application method [subgroup (b)]. Resin composite (Z 250, 3M ESPE, St. Paul, MN) was used to restore the cavities and light cured for 40 s. Twenty samples from each group were subjected to microleakage study. Two samples from both the subgroups of the three adhesives were used for scanning electron microscopic examination of the resin–dentin interfacial ultrastructure. Dye leakage scores were subjected to statistical analysis using Kruskal–Wallis and Mann–Whitney U‐tests at significance level of P < 0.05. Results: GB depicted significantly more microleakage which was significantly greater than OB and XV. The double application led to significant decrease in microleakage of GB with no significant effect on the microleakage scores of other two all‐in‐one adhesives, that is OB and XV. Conclusion: Double application of all‐in‐one self‐etch adhesives improves the marginal sealing ability in dentin although it appears to be product dependent. Microsc. Res. Tech. 78:489–494, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

18.
This study evaluated the effects of an antioxidant application on the compromised bond strength of an adhesive to dentin bleached with 35% hydrogen peroxide. The dentin surfaces of the pulp chambers of 70 human third molars were ground, and the specimens were assigned randomly into seven groups, as follows: (a) control (unbleached); (b) bleached for 45 min, bonded immediately; (c) bleached for 45 min, treated with sodium ascorbate (SA) for 2 min, and bonded; (d) bleached for 45 min, bonded after 2 weeks; (e) bleached for 12 days, bonded immediately; (f) bleached for 12 days, treated with SA for 10 min, and bonded; and (g) bleached for 12 days, bonded after 2 weeks. In each group, the multimode adhesive was applied in etch‐and‐rinse and self‐etch modes. The dentin surfaces were covered with a resin‐based composite, and the bonded specimens were sectioned to produce composite–dentin sticks. The sticks were attached to a testing machine and subjected to a tensile force, and the representative specimens were examined via scanning electron microscopy. The bond strength was not affected by the application period of the bleaching agent. Both bleaching treatments significantly reduced the bond strength to the dentin in the self‐etch or etch‐and‐rinse mode when compared with the control group. The bond strengths returned to normal levels with the SA applications or by waiting 2 weeks, regardless of the application period of the bleaching gel. The adhesive revealed a higher bond strength in the etch‐and‐rinse mode than in the self‐etch mode.  相似文献   

19.
The aim of the study was to evaluate the adhesion of a self‐adhering flowable composite resin to primary tooth enamel and dentin after silicon carbide paper (SiC) and laser pretreatment. Adhesive properties were evaluated as shear bond strength (SBS) and scanning electron microscopic (SEM) characteristics. A total 120 primary canine teeth were randomly divided into two groups to study enamel and dentin. Each group was divided into 6 subgroups (n = 10) according to type of surface preparation (SiC or Er:YAG laser) of enamel or dentin. Three methods were used to build cylinders of restoration on tooth surface: OptiBond All‐In‐One + Premise Flowable composite, OptiBond All‐In‐One + Vertise Flow and Vertise flow. After restoration, samples were tested for SBS and failure mode. Twenty eight samples were examined by SEM. The results of the study showed SBS of Vertise Flow was lower than others in enamel and dentin samples pretreated with SiC and in dentin samples pretreated with laser (P < 0.001). Compared to SiC pretreatment, laser pretreatment led to a significantly higher SBS with Vertise Flow on enamel (P < 0.001). Vertise Flow associated with the adhesive led to a higher SBS in enamel and dentin compared to Vertise Flow alone. Adhesive and mixed failure modes were observed more frequently in Vertise Flow groups. SEM images showed that Vertise Flow led to more irregularities on enamel and more open dentinal tubules after laser ablation compared SiC pretreatment. Microsc. Res. Tech. 79:334–341, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

20.
Previous studies have shown the effects of Er,Cr:YSGG laser irradiation on the dentin bond strength; but there are few reports that show the significance of the irradiation with different laser parameters on dentin bond strength and interface morphology. This in‐vitro study attempted to evaluate the microtensile bond strength (μTBS) and interface morphology of resin‐dentin interfaces, either followed by treatment with Er,Cr:YSGG laser irradiation with different parameters or not. The flattened dentin samples of 35 bovine teeth were embedded into acrylic blocks and randomly divided into seven groups according to surface treatments using Er,Cr:YSGG lasers with different parameters: 3 W/20 Hz, 3 W/35 Hz, 3 W/50 Hz, 1.5 W/20 Hz, 1.5 W/35 Hz, 1.5 W/50 Hz, or no laser treatment (n = 5). Composite buildups were done over bonded surfaces and stored in water (24 hours at 37°C). Specimens were sectioned into sticks that were subjected to μTBS testing and observed under FE‐SEM. Control groups (27.70 ± 7.0) showed statistically higher values than laser‐irradiated groups. There were no significant differences among laser groups. Despite that, increasing the pulse frequency yielded slightly higher bond strength. Depending on laser settings, Er,Cr:YSGG laser irradiation caused interfacial gaps and resin tags with wings morphology. With the parameters used in this study, Er,Cr:YSGG laser irradiation promoted morphological changes within resin‐dentin interfaces and negatively influenced the bond strength of adhesive systems. Microsc. Res. Tech. 78:1104–1111, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号