首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents results of an experimental investigation on T-section reinforced concrete (RC) beams strengthened with externally bonded carbon fiber-reinforced polymer (CFRP) strips. Specimens, one of which was the control specimen and the remaining six were the shear deficient test specimens, were tested under cyclic load to investigate the effect of CFRP strips on behavior and strength. Five shear deficient specimens were strengthened with side bonded and U-jacketed CFRP strips, and remaining one tested with its virgin condition without strengthening. The type and arrangement of CFRP strips and the anchorage used to fasten the strips to the concrete are the variables of this experimental work. The main objective was to analyze the behavior and failure modes of T-section RC beams strengthened in shear with externally bonded CFRP strips. According to test results premature debonding was the dominant failure mode of externally strengthened RC beams so the effect of anchorage usage on behavior and strength was also investigated. To verify the reliability of shear design equations and guidelines, experimental results were compared with all common guidelines and published design equations. This comparison and validation of guidelines is one of the main objectives of this work. The test results confirmed that all CFRP arrangements differ from CFRP strip width and arrangement, improved the strength and behavior of the specimens in different level significantly.  相似文献   

2.
为了调查动荷载作用下碳纤维布与钢筋混凝土梁的粘贴性能及加固效果,进行了5根模拟交通荷载(等幅正弦波形动荷载)作用下粘贴碳纤维布加固钢筋混凝土梁和1根保持荷载下粘贴碳纤维布加固钢筋混凝土梁以及2根对比梁的试验研究。试验中考虑了混凝土等级、配筋率、有无锚固条、粘贴长度、荷载幅值5个变化参数。试验结果表明,在模拟交通荷载的作用下,碳纤维布加固的钢筋混凝土梁粘贴性能满足要求,粘贴效果良好。在模拟交通荷载后的静载作用下,试验梁的抗弯承载力提高较多,加固效果明显,进一步验证了粘贴效果。  相似文献   

3.
This paper presents the shear performance of reinforced concrete (RC) beams with T-section. Different configurations of externally bonded carbon fiber-reinforced polymer (CFRP) sheets were used to strengthen the specimens in shear. The experimental program consisted of six full-scale, simply supported beams. One beam was used as a bench mark and five beams were strengthened using different configurations of CFRP. The parameters investigated in this study included wrapping schemes, CFRP amount, 90°/0° ply combination, and CFRP end anchorage. The experimental results show that externally bonded CFRP can increase the shear capacity of the beam significantly. In addition, the results indicated that the most effective configuration was the U-wrap with end anchorage. Design algorithms in ACI code format as well as Eurocode format are proposed to predict the capacity of referred members. Results showed that the proposed design approach is conservative and acceptable.  相似文献   

4.
预应力FRP加固混凝土结构技术研究与应用   总被引:1,自引:0,他引:1  
介绍了笔者进行的预应力芳纶纤维布和碳纤维筋加固混凝土结构的一些主要研究成果,内容包括:预应力芳纶纤维布永久锚具的开发;预应力芳纶纤维布的应力松弛损失研究;预应力芳纶纤维布加固混凝土梁的受弯、受剪性能研究;温度对芳纶纤维布配套粘结材料的力学性能影响研究;体外预应力碳纤维筋局部加固混凝土梁的力学性能研究;碳纤维筋预应力粗纤维混凝土梁的抗震性能研究;预应力纤维布加固混凝土结构的工程应用等。  相似文献   

5.
金浏  张江兴  李冬  杜修力 《工程力学》2022,39(12):31-40
采用同时考虑混凝土材料非均质性、钢筋与混凝土之间的相互作用以及CFRP布与混凝土之间的相互作用影响的三维细观数值模拟方法,建立了CFRP布加固RC梁剪切破坏力学分析模型。在验证了细观数值方法合理性的基础上,设计并建立了12根CFRP布加固RC梁细观模型,探究相同CFRP配纤率(用布量)前提下,不同CFRP布加固方案对单调荷载作用下RC梁的剪切性能及尺寸效应的影响。结果表明:CFRP布应变分布与裂缝位置紧密相关,越靠近裂缝位置的CFRP布应变越大,提供的抗剪贡献越多;在CFRP配纤率一致的前提下,CFRP布宽度大厚度小的加固方案优于CFRP布厚度大宽度小的加固方案;CFRP布U型加固RC梁剪切强度存在尺寸效应现象,但相同CFRP配纤率下,不同CFRP布加固方案对名义抗剪强度尺寸效应的影响较小,可以忽略。  相似文献   

6.
碳纤维布加固RC梁中粘结性能的非线性有限元分析   总被引:18,自引:0,他引:18  
碳纤维布加固钢筋混凝土(RC)梁中,碳纤维布与梁底混凝土的剥离破坏使碳纤维布的强度不能得到充分发挥。分析碳纤维布与梁底混凝土的粘结应力,是研究碳纤维布加固剥离破坏承载力的基础问题。根据4根碳纤维布加固RC梁的试验研究结果,采用商业有限元程序MSC.Marc建立有限元模型,进行了非线性计算分析。通过分离总粘结应力中的局部粘结应力,得到粘结延伸长度范围内的锚固粘结应力分布,并结合试验数据对其分布规律进行了研究。根据分析和试验结果,引入了“有效锚固粘结长度”和“锚固粘结应力”的概念,给出了极限荷载下锚固粘结应力的计算建议。  相似文献   

7.
This paper aims to develop 3D nonlinear finite element (FE) models for reinforced concrete (RC) deep beams containing web openings and strengthened in shear with carbon fiber reinforced polymer (CFRP) composite sheets. The web openings interrupted the natural load path either fully or partially. The FE models adopted realistic materials constitutive laws that account for the nonlinear behavior of materials. In the FE models, solid elements for concrete, multi-layer shell elements for CFRP and link elements for steel reinforcement were used to simulate the physical models. Special interface elements were implemented in the FE models to simulate the interfacial bond behavior between the concrete and CFRP composites. A comparison between the FE results and experimental data published in the literature demonstrated the validity of the computational models in capturing the structural response for both unstrengthened and CFRP-strengthened deep beams with openings. The developed FE models can serve as a numerical platform for performance prediction of RC deep beams with openings strengthened in shear with CFRP composites.  相似文献   

8.
This paper presents the results of fire resistance tests on reinforced concrete (RC) beams flexurally strengthened with carbon fibre reinforced polymer (CFRP) strips installed according to the near surface mounted (NSM) technique using two different adhesives. The beams were simultaneously subjected to a service load and the ISO 834 standard fire. Different fire protection schemes were studied, comprising a thinner insulation layer along the bottom soffit of the beams and a thicker one at the CFRP anchorage zones. The main objectives of this paper were (i) to understand in further depth the fire behaviour of NSM-strengthened RC beams, in particular the structural effectiveness of the strengthening system during fire, (ii) to evaluate the efficiency of the above-mentioned fire protection strategy in extending the CFRP mechanical contribution during fire, and (iii) to compare the fire performance of the NSM-strengthening system with that of the alternative externally bonded reinforcement (EBR) technique, recently investigated under similar test conditions. The results obtained showed that using the adopted insulation schemes (i.e., thicker insulation at the anchorage zone and thinner insulation in the current zone), even after the CFRP-concrete bond is highly damaged in the central zone of the beams, the strengthening system is able to retain its structural effectiveness through a cable mechanism: for insulation thicknesses of 25 mm (current zone) and 50 mm (anchorage zones), the fire resistance of the strengthening system was extended up to 114 min. The loss of effectiveness of the CFRP system occurred when the average temperature in the adhesive at the CFRP anchorage zones attained values ranging from 2.2 to 5.6 times its glass transition temperature (Tg). The comparison with the EBR-strengthened beams confirmed the much better performance of the NSM strengthening.  相似文献   

9.
《Composites Part B》2013,45(1):604-612
This paper presents experimental research on reinforced concrete (RC) beams with external flexural and flexural–shear strengthening by fibre reinforced polymer (FRP) sheets consisting of carbon FRP (CFRP) and glass FRP (GFRP). The work carried out has examined both the flexural and flexural–shear strengthening capacities of retrofitted RC beams and has indicated how different strengthening arrangements of CFRP and GFRP sheets affect behaviour of the RC beams strengthened. Research output shows that the flexural–shear strengthening arrangement is much more effective than the flexural one in enhancing the stiffness, the ultimate strength and hardening behaviour of the RC beam. In addition theoretical calculations are developed to estimate the bending and shear capacities of the beams tested, which are compared with the corresponding experimental results.  相似文献   

10.
The effectiveness of the near surface mounted (NSM) shear strengthening technique with carbon fiber reinforced polymer (CFRP) laminates applied in high-strength concrete beams with a certain percentage of existing steel stirrups is assessed by experimental research. In this context, the influence of the following main parameters are investigated: (i) the percentage and the inclination of the CFRP laminates; (ii) the percentage of existing steel stirrups; (iii) the existence of cracks when the reinforced concrete (RC) beams are shear strengthened with NSM CFRP laminates. The results showed that the NSM shear strengthening technique with CFRP laminates is more effective when applied to RC beams of high-strength concrete, not only in terms of increasing the load carrying capacity of the beams, but also in assuring higher mobilization of the tensile properties of the CFRP. Inclined laminates were more effective than vertical laminates and the shear resistance of the beams has increased with the percentage of laminates. Pre-cracked RC beams strengthened with NSM CFRP laminates have presented a load carrying capacity similar to that of the homologous uncracked strengthened beams.  相似文献   

11.
Various methods are developed for strengthening reinforced concrete beams against shear. Nowadays, external bonding of various composite members to RC beams was very popular and successfully technique internationally. This study present test results on strengthening of shear deficient RC beams by external bonding of carbon fiber reinforced polymer (CFRP) straps. Six RC beams with a T section were tested under cyclic loading in the experimental program. Width of the CFRP straps, arrangements of straps along the shear span, and anchorage technique that were applied at the ends of straps was the main parameters that were investigated during experimental study. Inclined CFRP straps were bonded along the shear spans of shear deficient beams for strengthening against shear by using epoxy. Arrangements and width of the inclined CFRP straps were the main parameters that were changed among the specimens. The test results confirmed that all CFRP arrangements improved the strength and stiffness of the specimens significantly. The failure mode, and ductility of specimens were proved to differ according to the CFRP strap width and arrangement along the beam. Experimental results were compared with the analytical approaches that were suggested by ACI-440 Committee report.  相似文献   

12.
In this paper, the effects of fatigue leading to crack formation and potential durability-bonding problems in reinforced concrete (RC) beams strengthened by carbon fiber reinforced polymer (CFRP) are studied. These effects are shown to cause CFRP de-bonding and loss of load carrying capabilities under static or low cyclic loading. Two series of RC beams with CFRP strengthening system are constructed and designed to fail in shear and flexural failures, respectively, under static loading. Repeated loading tests are conducted according to various loading ranges and loading cycles, and the experimentally determined fatigue properties are discussed. The test results show that it is possible to eliminate the debonding modes for longitudinally bonded CFRP using a U-wrap CFRP combination. The fatigue loads tested showed a significant effect on concrete rather than the CFRP system especially for the strengthened beams bearing a higher shear level. Moreover, the proposed equation to fit the testing SN curve and the discussion of the stress in the component materials could be used for fatigue life predictions of beams with CFRP strengthening systems.  相似文献   

13.
为解决纯粘贴U形纤维增强聚合物基复合材料(FRP)加固钢筋混凝土梁中FRP端部容易发生剥离破坏等问题,自主研发了对纤维布条带端部进行自锁锚固的方法和锚板,提出了端锚与粘贴并用的混锚U形条带抗剪加固方法。通过2根未加固梁、1根纯粘贴和2根混锚U形碳纤维增强聚合物基复合材料(CFRP)带抗剪加固梁的对比试验,证实了混锚抗剪加固的有效性:混锚能够对纤维带端部进行可靠锚固,阻止端部剥离破坏的发生,实现纤维拉断破坏,大幅度提高材料强度利用率。混锚加固在抑制混凝土梁斜裂缝开展、延缓箍筋屈服、提高箍筋和CFRP的极限应变以及提高抗剪承载力等多个方面的表现均明显优于纯粘贴加固。  相似文献   

14.
Carbon and glass fiber reinforced polymer (CFRP and GFRP) are two materials suitable for strengthening the reinforced concrete (RC) beams. Although many in situ RC beams are of continuous constructions, there has been very limited research on the behavior of such beams with externally applied FRP laminate. In addition, most design guidelines were developed for simply supported beams with external FRP laminates. This paper presents an experimental program conducted to study the flexural behavior and redistribution in moment of reinforced high strength concrete (RHSC) continuous beams strengthened with CFRP and GFRP sheets. Test results showed that with increasing the number of CFRP sheet layers, the ultimate strength increases, while the ductility, moment redistribution, and ultimate strain of CFRP sheet decrease. Also, by using the GFRP sheet in strengthening the continuous beam reduced loss in ductility and moment redistribution but it did not significantly increase ultimate strength of beam. The moment enhancement ratio of the strengthened continuous beams was significantly higher than the ultimate load enhancement ratio in the same beam. An analytical model for moment–curvature and load capacity are developed and used for the tested continuous beams in current and other similar studies. The stress–strain curves of concrete, steel and FRP were considered as integrity model. Stress–strain model of concrete is extended from Oztekin et al.’s model by modifying the ultimate strain. Also, new parameters of equivalent stress block are obtained for flexural calculation of RHSC beams. Good agreement between experiment and prediction values is achieved.  相似文献   

15.
Abstract: The near‐surface mounted (NSM) is one of the most recent techniques applied for the increase of the shear resistance of reinforced concrete (RC) beams. This technique involves the installation of carbon fibre reinforcement polymers (CFRP) laminates into thin slits open on the concrete cover of the elements to strengthen. The effectiveness of this technique for the shear strengthening of T cross‐section RC beams was assessed by experimental research. For this purpose, three inclinations of laminates were tested (45º, 60º and 90º) and, for each inclination, three percentages of CFRP were applied in RC beams with a percentage of steel stirrups of 0.10% (ρsw). The highest percentage of laminates was designed to provide a maximum load similar to the reference RC beam, which was reinforced with a reinforcement ratio of steel stirrups of 0.28% (ρsw = 0.28%). For each percentage of laminates, a homologous RC beam strengthened with unidirectional U‐shaped CFRP wet lay‐up sheets (discrete strips) applied according to the externally bonded reinforcement technique was also tested, with the purpose of comparing the effectiveness of these two CFRP‐strengthening techniques. To evaluate the influence of the percentage of steel stirrups in the effectiveness of the NSM technique, some of the abovementioned CFRP configurations were also applied in beams with ρsw = 0.17%.  相似文献   

16.
Although many in-situ RC beams are of continuous constructions, there has been very little research on the behavior of such beams with external reinforcement. This article presents an experimental program conducted to study the flexural behavior and redistribution of moment of reinforced high strength concrete (RHSC) continuous beams strengthened with carbon and glass-fiber-reinforced polymer (CFRP and GFRP) sheets. The program consists of six RHSC continuous (two-span) beams with overall dimensions equal to 250 × 150 × 6000 mm. One beam was not strengthened and was tested as a control beam. Five beams were strengthened with CFRP and GFRP in flexure along their sagging and hogging regions. The main parameters including type of FRP (GFRP or CFRP), the different ratios of CFRP sheet and effectiveness of end anchorage. The test results showed that the use of GFRP sheet in strengthening of continuous beam reduced loss in ductility and moment redistribution but it did not significantly increase the ultimate strength of them. The use of end anchorage in strengthened continuous beams increased the ultimate strength and moment redistribution. The moment enhancement ratio of the strengthened continuous beams was significantly higher than the ultimate load enhancement ratio in the same beam. Also existing international codes and model such as ACI, fib, JSCE, Teng and Toutanji for prediction of IC debonding strain or stress of strengthened continuous beams are verified. Verifications were carried out based on the test results in this research and the published literature on RC continuous beams strengthened with FRP.  相似文献   

17.
This experimental study aims at investigating the behavior of reinforced concrete (RC) beams strengthened by unidirectional and hybrid bidirectional fiber-reinforced polymer (FRP) sheets and subjected to cyclic loading. RC beams tested under cycled loading were subsequently repaired using both epoxy injection and external FRP sheets, and then re-tested under monotonic loading. Six RC beam specimens, two of which were control specimens and four were shear deficient, were upgraded with side-bonded FRP sheets in the first phase of the experimental program. In the second phase, three of the damaged beams were repaired using epoxy injection and unidirectional carbon fiber polymer (CFRP) sheets. The repairing method, FRP type, and FRP wrapping scheme were the test variables investigated. Test results show that the repair schemes imparted significant mechanical improvements in terms of ultimate shear capacity and ductility. The simultaneous application of epoxy injection and externally bonded FRP sheets was found to be a highly effective repair technique.  相似文献   

18.
A Near Surface Mounted (NSM) strengthening technique was developed to increase the shear resistance of concrete beams. The NSM technique is based on fixing, by epoxy adhesive, Carbon Fiber Reinforced Polymer (CFRP) laminates into pre-cut slits opened in the concrete cover of lateral surfaces of the beams. To assess the efficacy of this technique, an experimental program of four-point bending tests was carried out with reinforced concrete beams failing in shear. Each of the four tested series was composed of five beams: without any shear reinforcement; reinforced with steel stirrups; strengthened with strips of wet lay-up CFRP sheets, applied according to the externally bonded reinforcement (EBR) technique; and two beams strengthened with NSM precured laminates of CFRP, one of them with laminates positioned at 90° and the other with laminates positioned at 45° in relation to the beam axis. Influences of the laminate inclination, beam depth and longitudinal tensile steel reinforcement ratio on the efficacy of the strengthening techniques were analyzed. Amongst the CFRP strengthening techniques, the NSM with laminates at 45° was the most effective, not only in terms of increasing beam shear resistance but also in assuring larger deformation capacity at beam failure. The NSM was also faster and easier to apply than the EBR technique. The performance of the ACI and fib analytical formulations for the EBR shear strengthening was appraised. In general, the contribution of the CFRP systems predicted by the analytical formulations was slightly larger than the values registered experimentally. Performance of the formulation by Nanni et al. for NSM strengthening technique was also appraised. Using bond stress and CFRP effective strain values obtained in pullout bending tests with NSM CFRP laminate system, the formulation by Nanni et al. predicted a contribution of this CFRP system for the beam shear resistance of 72% the experimentally recorded values.  相似文献   

19.
通过10片普通钢筋混凝土(RC)梁及4片部分预应力混凝土(PPC)梁采用CFRP板抗剪加固的试验研究和非线性有限元分析,研究不同损伤程度、剪跨比、配箍率及预应力水平等因素对CFRP板加固RC&PPC梁抗剪性能的影响。结果表明:采用CFRP板对RC&PPC梁进行抗剪加固能够有效抑制斜裂缝的开展,提高加固梁斜截面抗剪承载能力,并改善梁的延性;RC梁损伤后加固,随着配箍率的增大以及剪跨比的减小,将提高加固RC梁的斜向开裂荷载、箍筋屈服荷载以及抗剪极限承载能力;随着预应力水平的提高,PPC加固梁的极限承载力增大,CFRP板抗剪加固效果比较显著;非线性有限元模型能够预测CFRP加固RC/PPC梁的抗剪性能,有限元计算结果与试验结果吻合良好;在进行CFRP板抗剪加固设计时,应对CFRP板的强度进行有效折减。  相似文献   

20.
This paper reports on an experimental investigation carried out to investigate the coupling of shear–flexural strengthening of RC beams. The presence of shear straps to enhance shear strength has the dual benefit of delaying debonding of CFRP sheets used for flexural strengthening. Six RC beams were tested; having various combinations of CFRP sheets and straps in addition to an unstrengthened beam as control test. The instrumentations used in these tests cover the strain measurements in different CFRP layers and located along the span, in addition to the slip occurring between the concrete and the CFRP sheets. Test results and observations showed that a significant improvement in the beam strength is gained due to the coupling of CFRP straps and sheets. Further, a more ductile behaviour is obtained as the debonding failure is prevented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号