1.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
In this work, we describe a novel type of bioaerosol test system based on a laminar airflow chamber that provides a homogenous aerosol of microbial cells with known concentrations and defined culturability to bioaerosol samplers positioned in the chamber. In the system, three control and monitoring points (CMPs) are implemented in which the number and culturability of microbes can be determined by combining optical particle counting with microscopic and culture-based microbiological analyses. This lineup is designed to quantify the biological sampling efficiency (BSE) of a bioaerosol sampling device. Seven bioaerosol samplers were tested with four fungal and one bacterial species and their BSEs have been determined under optimized standard operating conditions. After executing tests with the appropriate statistical power, this new laminar-flow platform demonstrated the sensitivity necessary to determine significant differences in the recovery efficiency of viable fungal spores and bacterial cells in modern samplers. Under these test conditions, the samplers showed considerable differences in BSEs for the individual fungal and bacterial species. Our data demonstrate that a large number of experimental repetitions and measurements under tightly controlled and monitored conditions are necessary to quantify the BSE of a given sampler and to compare them to each other. Employing this system improves biological evaluation of samplers because natural environments are not suitable for this task due to their high variabilities in homogeneity and distribution of cells as well as fluctuations in culturability ratios.

© 2019 American Association for Aerosol Research  相似文献   


3.
Objectives: To investigate the effect of different self-etch adhesive systems application techniques: active or passive in a single or double layer on adhesive–dentin microshear bond strength.

Methods: Occlusal surfaces of 48 extracted human molars were ground to expose flat superficial dentin surfaces. Specimens were randomly divided into two main groups according to the tested self-etch adhesive system either: One-step self-etch (AdperTM easy-one) or two-step self-etch (AdperTM SE Plus). Each adhesive system was applied on the prepared dentin surfaces followed one of these techniques: (1) Passive application of a single layer, (2) Active application of single layer, (3) Passive application of double adhesive layer (with light curing in between), and (4) Active application of double adhesive layers. Resin composite was packed inside micro-tubes fixed on the bonded dentin surfaces and light cured for 40 s. All specimens were stored in artificial saliva either for 24 h or 3 months before testing. Microshear bond strength test was employed using a universal testing machine at a crosshead speed of 0.5 mm/min.

Results: AdperTM SE Plus showed higher significant microshear bond strength in compared with AdperTM easy-one. For both adhesive systems active application showed higher significant microshear bond strength to dentin than passive application. Double application of adhesive systems showed lower microshear bond strength than single application.

Conclusion: Active application of self-etch adhesives could improve the dentin microshear bond strength. Double application with curing in between the layers did not improve the bond strength to the tested adhesive.  相似文献   


4.
Continuous ultraviolet germicidal irradiation (UVGI) has been extensively studied, but research on pulsed UVGI (PUVGI) is lacking and has primarily focused on disinfection of solid surfaces or liquids. This study addressed the gap in knowledge on the effectiveness of pulsed UVGI for disinfecting virus-laden calm air, with relevance to indoor rooms. Φ6 bacteriophage (a surrogate used to study communicable enveloped human respiratory viral pathogens such as influenza virus) was aerosolized by a Collison device into an enclosed test chamber, wherein the bioaerosol was exposed to PUVGI. The spectral content and performance of a pulsed white light lamp with a substantial UVC component were defined. Pulsed UV exposure of 10 to 30 s resulted in a two-log reduction in viable recovered virus from filter membranes and cyclone-based samplers. The small differences in Φ6 survival, after 10 to 30 s of exposure, emphasized the difficulty of complete eradication. However, exposure to 10 s of PUVGI resulted in significant reduction of virus viability. The dose–response displayed clear regimes of fast and slow exponential decay. Susceptibility factor for the fast-decay regime of aerosolized Φ6 (Z = 0.24 m2/J) was similar to those reported for influenza A virus aerosols at similar relative humidity. Our study demonstrated the potency of PUVGI against a viral bioaerosol. This has potential implications for the control of infectious bioaerosols in the healthcare setting.

© 2017 American Association for Aerosol Research  相似文献   


5.
6.
To assess indoor bioaerosols, a virtual impactor having 1 µm cutoff diameter was designed, fabricated, and evaluated with computational fluid dynamics simulation and also with laboratory test using polystyrene latex particles. Two other cutoff diameters of 635 nm and 1.5 µm were obtained by changing the inlet flow rate and the ratio of minor channel-to-inlet flow rates. In field test, the virtual impactor was operated with varying cutoff diameter and field-emission scanning electron microscope (FE-SEM) analysis was performed for each cutoff diameter to observe morphologies of indoor aerosol particles sampled at the major and minor outlet channels. Particles were sampled at both outlet channels using the SKC Button Aerosol sampler and subsequently cultured. By colony counting, it was found that 56% of cultured fungal particles and 63% of cultured bacterial particles had aerodynamic sizes smaller than 1 µm. MALDI-TOF analysis and visual inspection of culture samples were used to identify indoor bacterial and fungal species, respectively. Nearly same species of bacteria and fungi were detected both in the major and minor flow channels.

© 2017 American Association for Aerosol Research  相似文献   


7.
A 405 nm diode laser-based on-line bioaerosol detector, BioScout, was tested and compared with the Ultraviolet Aerodynamic Particle Sizer (UVAPS). Both instruments are based on laser-induced fluorescence of particles. Only a fraction of microbial particles produce enough fluorescence light to be detected by the instruments. This fluorescent particle fraction (FPF) is aerosol and instrument specific. The FPF values for common bacterial and fungal spores and biochemical particles were experimentally determined for both instruments. The BioScout exhibited higher FPF values for all the test aerosols except coenzyme NADH. The difference was higher for smaller particles. The FPF values of fungal spores and bacteria varied between 0.34 to 0.77 and 0.13 to 0.54 for the BioScout and the UVAPS, respectively. The results indicate that the 405 nm diode laser is a useful excitation source for fluorescence-based real-time detection of microbial aerosols. The FPF results of this study can be utilized to estimate the actual concentrations of bacterial and fungal spores in fluorescence-based ambient measurements.

Copyright 2014 American Association for Aerosol Research  相似文献   


8.
Vancomycin-sensitive and vancomycin-resistant Enterococcus (VSE and VRE) species have become a significant health problem. CHROMagar medium, which permits direct, color-based identification of target pathogens, could potentially be used to rapidly monitor airborne VSE and VRE. In this study, the efficiency of CHROMagar VRE medium without vancomycin supplementation (CVSE) for collecting airborne vancomycin-sensitive Enterococcus faecalis was evaluated in a chamber study. Subsequently, the performance of bioaerosol samplers combined with CVSE and CHROMagar VRE (CVRE) was evaluated in a hospital environment, a wastewater treatment plant, and a pig-rearing facility. Our results demonstrated that an Andersen impactor was much more effective than a Nuclepore filter for collecting airborne E. faecalis at relative humidity levels of 30% and 55%. In addition, approximately 10% of the isolated environmental Enterococcus strains were vancomycin-resistant. The average sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the colony identification were 58.5%, 81.3%, 5.5%, and 99.1%, respectively, for CVSE and 100%, 88.3%, 8.4%, and 100%, respectively, for CVRE. These findings indicate that the use of CHROMagar might provide a rapid method for detecting airborne VSE or VRE, shortening the detection time to 24–48 h. However, any mauve-colored colonies recovered on CVSE or CVRE by air sampling should be subjected to further identification tests.

Copyright 2014 American Association for Aerosol Research  相似文献   


9.
In bioaerosol monitoring applications, technologies allowing rapid and precise detection of airborne pathogens are highly demanded. One of such technologies, based on the immunoreaction-operating principle in nearly real-time mode without any specific labeling, is known as surface plasmon resonance (SPR). In previous studies, we have shown applicability of the SPR technology for rapid and selective detection of viral and bacterial aerosols where successful combination of the SPR machine with our earlier produced personal bioaerosol sampler opened new prospects in development of portable bioaerosol monitors. The current study is a logical continuation of our previous research dedicated to the technology development for rapid bioaerosol detection. Here, we focus on one of the main factors possibly influencing the SPR-based bioaerosol monitoring; the SPR performance on target bioaerosol detection was evaluated at conditions of substantial air contamination with different nontargeted microorganisms, commonly presented in the air. Besides, different compositions of sampling liquids were tested in regards to the SPR results interference. Our findings clearly verified high specificity of the technology even in cases of highly contaminated air environments with aerosols of biological and mineral origins. It was found that both nontargeted bioaerosols and nanosized aerosols of mineral background do not have significant influence on the specific SPR detection of targeted bioaerosols.

Copyright 2014 American Association for Aerosol Research  相似文献   


10.
Several low-volume inlets (flow rates ≤ 16.7 liters per minute (Lpm)) are commercially available as components of low-cost, portable ambient particulate matter samplers. Because the inlets themselves do not contain internal fractionators, they are often assumed to representatively sample “total” mass concentrations from the ambient air, independent of aerodynamic particle size and wind speed. To date, none of these so-called “TSP” inlets have been rigorously tested under controlled conditions. To determine their actual size-selective performance under conditions of expected use, wind tunnel tests of six commonly used omnidirectional, low-volume inlets were conducted using solid, polydisperse aerosols at wind speeds of 2, 8, and 24 km/h. With the exception of axially-oriented, isokinetic sharp-edge nozzles operating at 5 and 10 Lpm, all low-volume inlets showed some degree of nonideal sampling performance as a function of aerodynamic particle size and wind speed. Depending upon wind speed and assumed ambient particle size distribution, total mass concentration measurements were estimated to be negatively biased by as much as 66%. As expected from particle inertial considerations, inlet efficiency tended to degrade with increasing wind speed and particle size, although some exceptions were noted. The implications of each inlet's non-ideal behavior are discussed with regards to expected total mass concentration measurement during ambient sampling and the ability to obtain representative sampling for size ranges of interest, such as PM2.5 and PM10. Overall test results will aid in low-volume inlet selection and with proper interpretation of results obtained with their ambient field use.

Copyright © 2018 American Association for Aerosol Research  相似文献   


11.
The CIP 10-M personal sampler measures worker exposure to airborne particles by collecting particles in a rotating metal cup containing a few milliliters of a collection fluid. This device is mainly used to sample microorganisms or microbial components to measure bioaerosol concentrations in various occupational environments. Aqueous liquids are generally used, but their rapid evaporation limits the duration of sampling; alternative collection fluids could alleviate this problem. Indeed, the particle-collection efficiency of the rotating cup has not been extensively studied, and the only data available relate to a discontinued model. This study aimed to measure the collection efficiency of the current rotating cup model containing an aqueous (water) or viscous (ViaTrap mineral oil) collection fluid. The kinetics of evaporation confirmed that ViaTrap does not evaporate, making 8-h sampling campaigns in constant volumes feasible. Particles with a wide range of aerodynamic diameters (between around 0.1 and 10 µm) were produced using various test rigs and mono- or polydisperse test aerosols. Both new and older cup models performed similarly, with a collection efficiency of >80% for larger particles (aerodynamic diameters >2.8 µm), progressively decreasing to around 50% for aerodynamic diameters of 2.1 µm; with aerodynamic diameters of <1 µm, the collection efficiency was generally <10%. In physical terms, collection efficiency was unaffected by the type (aqueous or viscous) or volume (between 0 and 3 mL) of collection fluid used. Bias maps indicated that the inhalable fraction may be underestimated in occupational settings, particularly with aerosols mainly composed of particles with aerodynamic diameters of less than around 3 µm.

Copyright © 2016 American Association for Aerosol Research  相似文献   


12.
A fine particulate matter (PM2.5) monitoring network of filter-based federal reference methods and federal equivalent methods (FRM/FEMs) is used to assess local ambient air quality by comparison to National Ambient Air Quality Standards (NAAQS) at about 750 sites across the continental United States. Currently, FRM samplers utilize polytetrafluoroethylene (PTFE) filters to gravimetrically determine PM2.5 mass concentrations. At most of these sites, sample composition is unavailable. In this study, we present the proof-of-principle estimation of the carbonaceous fraction of fine aerosols on FRM filters using a nondestructive Fourier transform infrared (FT-IR) method. Previously, a quantitative FT-IR method accurately determined thermal/optical reflectance equivalent organic and elemental carbon (a.k.a., FT-IR organic carbon [OC] and elemental carbon [EC]) on filters collected from the chemical speciation network (CSN). Given the similar configuration of FRM and CSN aerosol samplers, OC and EC were directly determined on FRM filters on a mass-per-filter-area basis using CSN calibrations developed from nine sites during 2013 that have collocated CSN and FRM samplers. FRM OC and EC predictions were found to be comparable to those of the CSN on most figures of merit (e.g., R2) when the type of PTFE filter used for aerosol collection was the same in both networks. Although prediction accuracy remained unaffected, FT-IR OC and EC determined on filters produced by a different manufacturer show marginally increased prediction errors suggesting that PTFE filter type influences extending CSN calibrations to FRM samples. Overall, these findings suggest that quantifying FT-IR OC and EC on FRM samples appears feasible.

© 2018 American Association for Aerosol Research  相似文献   


13.
Surgical face masks are commonly used by the general public in indoor environments. However, masks could be contaminated, resulting in secondary microbial infections when they act as touchable fomites. Therefore, we evaluated the ability and durability of a covalently bound antimicrobial surfactant coated onto mask surfaces before use to reduce the bacterial burden upon exposure to aerosols. With regard to bacteria that settled onto the mask surface, this antimicrobial product provided >99.3% efficiency for all three tested bacterial species. In addition, the antimicrobial ability of the coated mask maintained efficacy at least one week after coating. For bioaerosols that came into contact with the mask (103 CFU/m3), the antimicrobial agent reduced the average colony rates by 91.8%, but the rates decreased with increased bioaerosol concentrations. Moreover, regardless of whether the coated mask was processed with the bioaerosol penetration test or the National Institute for Occupational Safety and Health-certified sodium chloride aerosol test, the filtration performance of the surgical mask was not significantly altered. These results demonstrate that this antimicrobial product has a durable inhibitory activity for the reduction of bacterial burdens on masks.

Copyright © 2016 American Association for Aerosol Research  相似文献   


14.
Detection and quantification of dilute viral aerosols, as encountered outside animal housing facilities, requires methods that are able to detect small numbers of viruses in large volumes of air. This study compared the performance of two size-differentiating cascade impactors; an Andersen 8-stage (ACI; 28.3 L/min) and a high volume Tisch (TCI; 1,133 L/min) to assess sampling efficiency for detecting porcine reproductive and respiratory syndrome virus (PRRSV) and influenza A virus (IAV). Samples of particles sorted by aerodynamic diameter were analyzed by quantitative polymerase chain reaction (qPCR) and collection efficiency was assessed by particle size. Collection media (minimum essential medium [MEM] and beef extract [BE]), elution technique (active versus passive), and sampling times (10, 20, and 30 min) were variables assessed for the TCI sampler. Extraction efficiency was 35% higher with BE as compared to that of MEM (p = 0.0007); active extraction technique was 19% more efficient than the passive technique (p = 0.03); time of sampling did not significantly affect the amount of virus recovered. The ACI sampler was more efficient in detecting both viruses from small and medium sized airborne particles (≤3 μm) as compared to the TCI sampler (p < 0.001). The latter sampler, however, was more efficient at IAV detection from large airborne particles (>3 μm) (p = 0.0025) indicating the potential of this sampler in detecting the presence of small amounts of viruses in aerosols under field conditions.

© 2017 American Association for Aerosol Research  相似文献   


15.
Detection of bioaerosols is important in fields ranging from environmental health monitoring to biosurveillance, and current detector weaknesses have motivated the development of new technologies. In this work, a detector was built, which applies the principles of droplet microfluidics to bioaerosol detection. Droplet microfluidics is a subfield of microfluidics based on the creation of monodisperse microdroplets with compartmentalized reagents and supports enhanced assays and fluidic manipulations. The bioaerosol detector operates by aerodynamically focusing aerosols directly into these droplets to harness the benefits of the microreactor environment. A breadboard detector system, which consisted of an aerodynamic focusing lens, aerosol-focusing capillary, microfluidic droplet chip, and optical microscope, was constructed. Computational fluid dynamic simulations and Lagrangian particle tracking modeling were conducted to identify the optimal conditions for focusing. Preliminary experiments, where aerosols were deposited onto a solid substrate, demonstrated sub 200-µm spot diameters for aerodynamic diameters of 2–5 µm. Test aerosols were then generated, and collected into the microfluidic liquid interface on the chip as verified by microscopy. Recovery efficiency of the aerosols was dependent on aerosol size and ranged from about 27% to nearly 100%. Finally, to prove bioaerosol collection and detection, a droplet propidium iodide (PI) assay was performed: the system distinguished between E. coli and non-biological aerosols within 20 s. Overall, this work established the technique of direct collection of bioaerosols into a convenient droplet microfluidic platform for detection.

Copyright © 2017 The Johns Hopkins University Applied Physics Laboratory  相似文献   


16.
Purpose: To investigate the effects of phosphoric acid esters (PAEs)-containing primers on the micro-tensile bond strengths (MTBS) of etched enamel, the micro-morphologies of the resin–enamel interfaces, and the enamel surfaces.

Materials and Methods: Thirty-three bovine incisors were used in this study. After the labial enamel surfaces were highly polished, they were etched, water sprayed, and air-dried. Afterward, the enamel surfaces were treated with or without (control) one of three PAEs-containing primers (40%MDP, Ivoclar Vivadent; Resulcin AquaPrime A + B, DMG; Xeno V, Dentsply), water sprayed, and air-dried. Subsequently, an adhesive Heliobond (Ivoclar Vivadent) was applied and resin composite (Core Build-up, Bisco) was placed incrementally. They were prepared into multiple beams of about 1 × 1 × 8 mm for MTBS tests. The enamel surfaces and resin–enamel interfaces were analyzed by SEM and TEM. The data were analyzed by two-way ANOVA and LSD test.

Results: Using PAEs-containing primers could increase the enamel MTBS (p < 0.05). The primer MDP produced higher MTBS than the primer Resulcin AquaPrime A + B and Xeno V. The SEM findings revealed the primed enamel surfaces were covered with a thin or glue-like layer of monomer-calcium salts of PAEs and the residual enamel crystallites, and various micro-porosities were detected within the hybrid layers. The TEM findings revealed the hydroxyapatite crystallites were tightly covered by the adhesive, the adhesive mixed with resin composite, or sparse irregular enamel crystallites.

Conclusion: The application of PAEs-containing primers on the etched enamel substrate could significantly increase the immediate enamel bond strengths. However, this effect was dependent on the individual PAEs-containing primer used.  相似文献   


17.
Objective: This study aimed to evaluate the degree of conversion (DC) of two different resin cements polymerized under the monolithic zirconia specimens in different thicknesses and colors.

Material and methods: Partially stabilized monolithic zirconia blocks (inCoris TZI) were cut into three different thicknesses (0.5, 1.0, and 2.0 mm) and the specimens were divided into four color groups (A1, A2, A3, and A4). The light transmittance of each specimen was measured. Panavia F 2.0 or Variolink N resin cement was applied into teflon mold and irradiated using the light emitting diode curing unit for 20 s under monolithic zirconia specimen (n = 10). The resin cement specimens were stored at room temperature under dry conditions. The DC of each specimen was measured by Fourier transform infrared-attenuated total reflection (FT-IR/ATR) spectroscopy after the 1st and 10th day. Data were analyzed with two-way analysis of variance (ANOVA), two-way repeated measures ANOVA, three-way repeated measures ANOVA, and the Tukey least significant difference (LSD) tests (α = 0.05).

Results: The light-cure resin cement groups showed higher DC than the dual-cure resin cement groups (p < 0.05). The DC of both resin cements reduced with an increase in the thickness and darkening of the color of monolithic zirconia specimens. There was a statistically meaningful increase in the 10th-day values for dual-cure resin cement (p < 0.05), whereas there were no significant differences between the 1st- and 10th-day values for light-cure resin cement (p > 0.05).

Conclusion: The use of light-cure resin cement can be suggested for the luting of monolithic zirconia restorations.  相似文献   


18.
Introduction: The aim of this study was to evaluate the residual monomer release from orthodontic adhesives cured with light-emitting diode (LED) and halogen light sources.

Methods: Seven hundred and twenty stainless steel brackets were divided into 3 groups according to the adhesive system used (Transbond XT light-cure adhesive [TXT], Transbond LR capsule [LR], and Light Bond light-cure adhesive paste [LB]), and each group was divided into 2 subgroups according to light-curing procedure (LED or halogen). Brackets were bonded with adhesives onto tooth buccal surfaces and polymerized. Each specimen contained 24 brackets that simulated the oral environment (n = 5). The specimens were immersed in a 75% ethanol/water solution at 37 °C for 10 min, 1 h, 1 d, 7 d, 14 d, and 30 d, respectively. Eluted monomers (Bis-GMA, UDMA, and TEGDMA) were detected using HPLC.

Results: There was residual monomer release at all time periods, and the highest amount of release was observed cumulatively on the 30th day. The cumulative Bis-GMA released from adhesives was not different (p > 0.05). The cumulative TEGDMA released from adhesives was statistically different (p < 0.05). There was no statistical difference between QTH and LED light-curing units for each adhesive (p > 0.05).

Conclusions: The release of residual monomers stays at a high level for a long time after polymerization. The total leaching of residual monomers from the Light Bond light-cure sealant resin plus Light Bond light-cure adhesive paste was higher than that of other materials for both curing units. Different curing units (LED or QTH) did not affect the monomer release from the orthodontic adhesives.  相似文献   


19.
Objectives: The aim of this in vitro study was to evaluate the effect of different desensitizers’ application on the microleakage of previously restored Class V composite resin restorations.

Materials and methods: Class V cavities were prepared on the buccal surfaces of 40 extracted human third molars. Forty box-shaped cavities were divided into four groups, based on the desensitizers used (n = 10). All teeth were restored with the same bonding agent and composite material. No desensitizer was applied in the control group. In the experimental groups, BisBlock, Gluma and Universal bonding agents were the desensitizers. The desensitizers were applied after completion of composite restorations according to manufacturers’ instructions. All specimens were then thermocycled at 5–55 °C, with a 10-s dwell time for 500 cycles. The samples were then immersed in 0.5% methylene blue dye for 24 h, sectioned into two equal halves, evaluated for microleakage using a stereomicroscope at 30× magnification and scored on a scale of 0–3. The data were analysed using the Kruskal–Wallis test at the significance level p < 0.05.

Results: There were no significant differences in microleakage after desensitizer application (p > 0.05). However, based on the obtained numerical values in our study, while the BisBlock and bonding groups showed lower microleakage at the occlusal margin, BisBlock, Gluma and bonding group showed lower microleakage at the gingival margin compared to the control group.

Conclusions: The application of desensitizers as a post-treatment option could be considered an advisable procedure to minimize microleakage.  相似文献   


20.
An anisokinetic shrouded nozzle system was designed for sampling particles at a constant low flow rate from a ventilation duct to an aerodynamic particle sizer (APS). Shrouded anisokinetic nozzles are a means for sampling from a moving airstream with higher particle transmission than with unshrouded isokinetic nozzles. This shrouded nozzle sampling system was evaluated in an experimental ventilation duct system. Aspiration and transport efficiency measurements were made for five particle sizes in the range 1–13 μm at each of three duct air speeds in the range 2.2–8.8 m/s. Under these conditions, the shrouded nozzle system showed improved performance compared to buttonhook isokinetic nozzles, especially for larger particles and higher air speeds. Measured transmission efficiencies through the shrouded nozzle sampling system were generally higher and more reliably predictable than those through buttonhook isokinetic nozzles. Model predictions of transport and aspiration efficiencies of the shrouded nozzle system showed good agreement with measurements over the entire range of experimental conditions. The shrouded nozzle sampling system could be used to measure concentrations in ventilation ducts with an APS for particles in the diameter range 1–13 μm.

Copyright 2014 American Association for Aerosol Research  相似文献   