首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We introduce a new electrical measurement technique for aerosol detection, based on pulsed unipolar charging followed by a non-contact measurement of the rate of change of the aerosol space charge in a Faraday cage. This technique, which we call “aerosol measurement with induced currents,” has some advantages compared to the traditional method of collecting the charged particles on either an electrode or with a particle filter. We describe the method and illustrate it with a simple and miniature (shirt-pocket-sized) instrument to measure lung-deposited surface area. Aerosol measurement by induced currents can also be applied to more complex devices.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
The estimation of air velocity distributions and particle trajectories is inevitable to analyse the mechanism of classification, but the direct measurement of il is extremely difficult.

The authors, here report three dimensional air velocity distributions within the inside drum of model Sturtevant-type air classifier measured by a spherical five-holed Pitot-lube, and also two dimensional particle ejecting velocities on a model distributor determined by photography.

Using those results, the cut size calculated from particle trajectories in the classifier is compared with the experimental results and theoretical values.  相似文献   


3.
A new instrument, density monitor (DENSMO), for aerosol particle size distribution characterization and monitoring has been developed. DENSMO is operationally simple and capable of measuring the effective density as well as the aerodynamic and the mobility median diameters with a time resolution of 1 s, from unimodal particle size distributions. The characterization is performed with a zeroth order mobility analyzer in series with a low pressure impactor and a filter stage. The operation of DENSMO was investigated with sensitivity analysis and, based on the results, optimal operation parameters were determined. DENSMO was also compared, in lab test measurements, against a reference method with several particle materials with bulk densities from 0.92 to 10.5 g/cm3. The results show that the deviation from the reference method was less than 25% for suitable materials.

Copyright © 2016 American Association for Aerosol Research  相似文献   


4.
Many well-established models can be applied to calculate the filtration efficiencies. In these models the filtration velocity and challenging particle size are assumed to be known accurately. However, in realistic filtration tests, the filtration velocity has profiles dependent on the filter holder geometry and experimental conditions; the challenging particles have size distributions dependent on the instruments and operation conditions. These factors can potentially affect the measured filtration efficiency and lead to discrepancies with the models.

This study aims to develop an integrative model to predict the filtration efficiencies in realistic tests by incorporating the effects of the filtration velocity profile and challenging particle size distribution classified by a differential mobility analyzer (DMA) into the existing filtration models. Face velocity profile is modeled with fluid mechanics simulations; the initial generated particle size distribution, the particle charging status and the DMA transfer function are modeled to obtain the challenging particle size distribution. These results are then fed into the filtration models. Simulated results are compared with experimental ones to verify the model accuracy. This model can be used to reduce filtration test artifacts and to improve the experimental procedure.

The results reveal that the face velocity upstream the filter exhibits high degree of homogeneity not affecting the filtration efficiency if the filter pressure drop is not very low. The generated particle size distribution and the DMA selection size window could influence the challenging particle size distribution and therefore the measured filtration efficiency.

Copyright © 2017 American Association for Aerosol Research  相似文献   


5.
Direct ultraviolet (UV) photoionization enables electrical charging of aerosol nanoparticles without relying on the collision of particles and ions. In this work, a low-strength electric field is applied during particle photoionization to capture charge as it is photoemitted from the particles in continuous flow, yielding a novel electrical current measurement. As in conventional photocharging-based measurement devices, a distinct electrical current from the remaining photocharged particles is also measured downstream. The two distinct measured currents are proportional to the total photoelectrically active area of the particles. A three-dimensional numerical model for particle and ion (dis)charging and transport is evaluated by comparing simulations of integrated electric currents with those from charged soot particles and ions in an experimental photoionization chamber. The model and experiment show good quantitative agreement for a single empirical constant, KcI, over a range of particle sizes and concentrations providing confidence in the theoretical equations and numerical method used.

Copyright © 2018 American Association for Aerosol Research  相似文献   


6.
The effective density and size-resolved volatility of particles emitted from a Rolls-Royce Gnome helicopter turboshaft engine are measured at two engine speed settings (13,000 and 22,000 RPM). The effective density of denuded and undenuded particles was measured. The denuded effective densities are similar to the effective densities of particles from a gas turbine with a double annular combustor as well as a wide variety of internal combustion engines. The denuded effective density measurements were also used to estimate the size and number of primary particles in the soot aggregates. The primary particle size estimates show that the primary particle size was smaller at lower engine speed (in agreement with transmission electron microscopy analysis). As a demonstration, the size-resolved volatility of particles emitted from the engine is measured with a system consisting of a differential mobility analyzer, centrifugal particle mass analyzer, condensation particle counter, and catalytic stripper. This system determines the number distributions of particles that contain or do not contain non-volatile material, and the mass distributions of non-volatile material, volatile material condensed onto the surface of non-volatile particles, and volatile material forming independent particles (e.g., nucleated volatile material). It was found that the particulate at 13,000 RPM contained a measurable fraction of purely volatile material with diameters below ~25 nm and had a higher mass fraction of volatile material condensed on the surface of the soot (6%–12%) compared to the 22,000 RPM condition (1%–5%). This study demonstrates the potential to quantify the distribution of volatile particulate matter and gives additional information to characterize sampling effects with regulatory measurement procedures.

Copyright © 2017 American Association for Aerosol Research  相似文献   


7.
Accurate measurement of particle size distribution using electrical-mobility techniques requires knowledge of the charging state of the sampled particles. A consistent particle charge distribution is possible with bipolar diffusion chargers operated under steady-state condition. Theoretical steady-state charge distributions for bipolar charging are well established but recent studies have shown that the performance of particle chargers is a strong function of particle size, particle concentration, ion source, and charger operating conditions. Most of these studies have focused on particles smaller than 100 nm and the applicability of these results for particles larger than 100 nm must be investigated. In this study, experimentally obtained singly-charged and doubly-charged fractions are compared against theoretical predictions for particles in the size range of 100 to 900 nm. The experimental results show that the commercial soft X-ray charger performs as theoretically-predicted over the range of conditions studied while the performance of other commonly used radioactive chargers (85Kr and 210Po) are dependent on source strengths, flowrates, particle charge polarities, and particle sizes. From measurements of particle residence times and ion concentrations in different test bipolar chargers, prior observations of flowrate-dependent charging fractions can be explained. Additionally, the results from this study are used to determine an acceptable time period for usage of the commercial TSI 3077A 85Kr chargers for steady-state charging as a function of flowrate.

Copyright © 2018 American Association for Aerosol Research  相似文献   


8.
In this article, a proof of concept of a new measurement instrument, differential diffusion analyzer (DDA), is established. The DDA enables the measurement of the size distribution of sub-10 nm aerosol particles, and it can also be used as a size classifier to separate a certain particle size from a size distribution for subsequent analysis. The developed technique is based on the diffusion separation of different size particles. Thus, the main advantage of the DDA compared to other methods is that particle charging is not required. Simulated and experimentally measured transmission efficiencies show that the diffusion-based differential size classification is a feasible concept, and moreover, shows that particle size is inversely proportional to the square root of the total flow rate.

Copyright © 2017 American Association for Aerosol Research  相似文献   


9.
Bipolar diffusion charging is used routinely in aerosol electrical mobility size distribution measurements. In this study, aerosol charge fractions produced by six bipolar chargers (neutralizers) were measured using a tandem differential mobility analyzer system. Factors that were studied include the type of ion source (210Po, 85Kr, 241Am, and soft X-ray), source activity, charger design, and aerosol flowrate. It was found that all six types of neutralizers achieve stationary state charge distributions when the source activity is sufficiently high. For 210Po neutralizers with an initial radioactivity of 18.5 MBq (0.5 mCi), stationary state charge distributions are achieved when the source is less than 3.25 years old (residual activity no less than 0.0527 MBq). Stationary state was achieved for 85Kr neutralizers having residual radioactivity greater than 70 MBq. Source activities of 241Am and soft X-ray neutralizers are discussed. Aerosol charge fractions for six neutralizers remain reasonably invariant over a wide range of flowrates. The positive charge fractions achieved by the soft X-ray neutralizer are higher than those by the other five neutralizers using radioactive sources while negative charge fractions for all neutralizers studied are all in a similar range. This study also raises questions about bipolar charging fractions used for data inversion in some scanning mobility particle spectrometer (SMPS) systems, and underscores the need to better understand bipolar charging to achieve more accurate measurements of particle size distributions.

Copyright 2014 American Association for Aerosol Research  相似文献   


10.
The Pegasor PPS-M sensor is an electrical aerosol sensor based on diffusion charging and current measurement without particle collection. In this study, the role and effect of each component in the instrument is discussed shortly and the results from a thorough calibration measurements are presented. A comprehensive response model for the operation of the PPS-M sensor was developed based on the calibration results and computational fluid dynamics (CFD) modeling results. The obtained response model, covering the effects of the particle charger, the mobility analyzer, and both diffusion and inertial losses, was tested in the laboratory measurements with polydisperse test aerosols, where a good correlation between the model and the measured results was found.

Copyright 2014 American Association for Aerosol Research  相似文献   


11.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


12.
Accurate refractive index values are required to determine the effects of aerosol particles on direct radiative forcing. Theoretical retrievals using extinction data alone or extinction plus absorption data have been simulated to determine the sensitivity of each retrieval. A range of aerosol types with a range of different refractive indices were considered. The simulations showed that the extinction-only retrieval was not able to accurately or precisely retrieve refractive index values, even for purely scattering compounds, but the addition of a simulated absorption measurement greatly improved the retrieval.

Copyright 2014 American Association for Aerosol Research  相似文献   


13.
To address the critical need for improving the chemical characterization of the organic composition of ambient particulate matter, we introduce a combined thermal desorption aerosol gas chromatograph—aerosol mass spectrometer (TAG-AMS). The TAG system provides in-situ speciation of organic chemicals in ambient aerosol particles with hourly time resolution for marker compounds indicative of sources and transformation processes. However, by itself the TAG cannot separate by particle size and it typically speciates and quantifies only a fraction of the organic aerosol (OA) mass. The AMS is a real-time, in-situ instrument that provides quantitative size distributions and mass loadings for ambient fine OA and major inorganic fractions; however, by itself the AMS has limited ability for identification of individual organic compounds due to the electron impact ionization detection scheme used without prior molecular separation.

The combined TAG-AMS system provides real-time detection by AMS followed by semicontinuous analysis of the TAG sample that was acquired during AMS operation, achieving simultaneous and complementary measurements of quantitative organic mass loading and detailed organic speciation. We have employed a high-resolution time-of-flight mass spectrometer (HR-ToF-MS) to enable elemental-level determination of OA oxidation state as measured on the AMS, and to allow improved compound identification and separation of unresolved complex mixtures (UCM) measured on the TAG. The TAG-AMS interface has been developed as an upgrade for existing AMS systems. Such measurements will improve the identification of organic constituents of ambient aerosol and contribute to the ability of atmospheric chemistry models to predict ambient aerosol composition and loadings.

Copyright 2014 American Association for Aerosol Research  相似文献   


14.
This article presents a verification and validation study of the stochastic particle-resolved aerosol model PartMC. Model verification was performed against self-preserving analytical solutions, while for validation three experiments were performed where the size distribution evolution of coagulating ammonium sulfate particles was measured in a cylindrical stainless steel chamber. To compare with the chamber measurements, PartMC was extended to include the representation of fractal particle structure and wall loss. This introduced five unknown parameters to the governing equation, which were determined by a combination of scanning electron microscopy (SEM) analysis and an objective optimization procedure. Excellent agreement between modeled and measured size distributions was achieved using the same set of parameters for all three experiments. Assuming spherical particles led to model results that were inconsistent with the measurements. The best agreement between model and measurement was obtained for the fractal dimension of 2.3, indicating that the non-spherical structure of the particle agglomerates in the chamber needed to be taken into account.

© 2017 American Association for Aerosol Research  相似文献   


15.
The charging behavior of metal nanoparticles bouncing from conductive surfaces was investigated in a single-stage-low-pressure-impactor. Ag and Pt particles of a fixed particle size between 20 nm and 100 nm were impacted on targets of bulk Au and Pt, respectively, and the resulting contact charge was measured as a function of impact velocity. The influence of target hardness was revealed by the comparison to measurements with soft nanostructured layers obtained by direct current sputtering of Au and Pt on mica discs. From the dataset, regions of elastic, elastoplastic, and fully plastic particle deformation were identified, and the size-dependent effective yield stress for the respective particle materials was calculated. The influence of electron back-tunneling in the separation phase of the collision on the effective contact charge is discussed.

Copyright 2014 American Association for Aerosol Research  相似文献   


16.
The inference of particle size distributions from differential mobility analyzer (DMA) data requires knowledge of the charge distribution on the particles being measured. The charge distribution produced by a bipolar aerosol charger depends on the properties of the ions produced in the charger, and on the kinetics of charge transfer from molecular ions or ion clusters to the particles. A single parameterization of a theoretically predicted charge distribution is employed in most DMA analyses regardless of the atmospheric conditions being probed. Deviations of the actual charge distribution from that assumed in the data analysis will bias the estimated particle size distribution. We examine these potential biases by modeling measurements and data inversion using charge distributions calculated for a range of atmospheric conditions. Moreover, simulations were performed using the ion-to-particle flux coefficients predicted for a range of properties of both the particles and ions. To probe the biases over the full range of particle sizes, the measurements were simulated through an atmospheric new particle formation event. The differences between the actual charge distribution and that according to the commonly used parametrization resulted in biases as large as a factor of 5 for nucleation-mode particles, and up to 80% for larger particles. Incorrect estimates of the relative permittivity of the particles or not accounting for the temperature and pressure effects for measurements at 10 km altitude produced biases in excess of 50%; three-fold biases result from erroneous estimates of the ion mobility distribution. We further report on the effects of the relative permittivity of the ions, the relative concentrations of negative and positive ions, and truncation of the number of charge states considered in the inversion.

Copyright © 2017 American Association for Aerosol Research  相似文献   


17.
An in vitro study was conducted in the Alberta idealized child mouth-throat, which mimics average deposition in a set of nine 6–14-year-old subjects, to examine the enhancement of deposition of monodisperse uniformly charged particles as a result of induced electrostatic forces. A purpose-based atomizer was designed and built for generating monodisperse, uniformly charged particles. The atomizer generates droplets by jet break up under the action of capillary waves and charges them via electrostatic induction. The experiments cover different particle aerodynamic diameters (d a = 3.6, 4.4, and 5.9 μm), at two flow rates (Q = 10 and 20 L/min), over a wide range of elementary charges per particle (0–10,000 e). The results show substantial increases in particle deposition in the present idealized pediatric mouth throat compared to neutral aerosols. Two empirical equations, as a function of Reynolds number, Stokes number, and induced charge number are introduced for the prediction of mouth-throat deposition in children, based on two different characteristic diameters of the airway.

Copyright 2014 American Association for Aerosol Research  相似文献   


18.
It is currently admitted that for each filtration process using pleated filters, at least three steps can be distinguished: depth and surface filtration, which are common to flat filters, and surface reduction. This step is caused by inefficient filling of the pleat due to the filter geometry. For combustion aerosol, it has been proved that this third step strongly depends on the filtration velocity resulting in an increase of the resistance when air flow decreases. This observation leads one to think that Brownian diffusion, higher for low velocities, could influence the clogging dynamic of a pleated filter.

In this article, a protocol derived from the dust cake preparation method published by Schmidt is developed. The aim of this study is to measure the aerosol penetration inside a filter media as well as in a pleat using a scanning electronic microscope and energy dispersive X-ray spectroscopy elementary detection. This method has also been extended to the study of pleated filters to measure the particle distribution inside the pleat. Filters were loaded with nanoparticles in order to evaluate the specificity of the diffusional regime on the clogging of pleated HEPA filters. For pleated filters, two filtration velocities were investigated: 2.5 and 0.2 cm/s.

Copyright 2014 American Association for Aerosol Research  相似文献   


19.
A novel instrument has been developed for generating highly monodisperse aerosol particles with a geometrical standard deviation of 1.05 or less. This aerosol generator applies a periodic mechanical excitation to a micro-liquid jet obtained by aerodynamic flow-focusing. The jet diameter and its fastest growth wavelength have been optimized as a function of the flow-focusing pressure drop and the liquid flow rate. The monodisperse aerosol generated by this instrument is also charge neutralized with bipolar ions produced by a non-radioactive, corona discharge device. Monodisperse droplet generation in the 15- to 72-μm diameter range from a single 100-micron nozzle has been demonstrated. Both liquid and solid monodisperse particles can be generated from 0.7- to 15-μm diameter by varying solution concentration, liquid flow rate, and excitation frequency. The calculated monodisperse particle diameter agrees well with independent measurements. The operation of this new monodisperse aerosol generator is stable and reliable without nozzle clogging, typical of other aerosol generators at the lower end of the operating particle size ranges.

Copyright © 2016 American Association for Aerosol Research  相似文献   


20.
We describe a new method for focusing and concentrating a stream of moving micron-sized aerosol particles in air. The focusing and concentrating process is carried out by the combined drag force and optical force that is generated by a double-layer co-axial nozzle and a focused doughnut-shaped hollow laser beam, respectively. This method should supply a new tool for aerosol science and related research.

Copyright © 2018 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号