首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a new method for focusing and concentrating a stream of moving micron-sized aerosol particles in air. The focusing and concentrating process is carried out by the combined drag force and optical force that is generated by a double-layer co-axial nozzle and a focused doughnut-shaped hollow laser beam, respectively. This method should supply a new tool for aerosol science and related research.

Copyright © 2018 American Association for Aerosol Research  相似文献   


2.
To address the critical need for improving the chemical characterization of the organic composition of ambient particulate matter, we introduce a combined thermal desorption aerosol gas chromatograph—aerosol mass spectrometer (TAG-AMS). The TAG system provides in-situ speciation of organic chemicals in ambient aerosol particles with hourly time resolution for marker compounds indicative of sources and transformation processes. However, by itself the TAG cannot separate by particle size and it typically speciates and quantifies only a fraction of the organic aerosol (OA) mass. The AMS is a real-time, in-situ instrument that provides quantitative size distributions and mass loadings for ambient fine OA and major inorganic fractions; however, by itself the AMS has limited ability for identification of individual organic compounds due to the electron impact ionization detection scheme used without prior molecular separation.

The combined TAG-AMS system provides real-time detection by AMS followed by semicontinuous analysis of the TAG sample that was acquired during AMS operation, achieving simultaneous and complementary measurements of quantitative organic mass loading and detailed organic speciation. We have employed a high-resolution time-of-flight mass spectrometer (HR-ToF-MS) to enable elemental-level determination of OA oxidation state as measured on the AMS, and to allow improved compound identification and separation of unresolved complex mixtures (UCM) measured on the TAG. The TAG-AMS interface has been developed as an upgrade for existing AMS systems. Such measurements will improve the identification of organic constituents of ambient aerosol and contribute to the ability of atmospheric chemistry models to predict ambient aerosol composition and loadings.

Copyright 2014 American Association for Aerosol Research  相似文献   


3.
Highly sensitive detection of nanoscale aerosols, or nano-aerosols, is a difficult challenge. Here, we report a fiber optical technique that is capable of detecting trace-level nano-aerosols. Our method is based on monitoring the nano-aerosol-induced resonance shift due to the optical Whispering-Gallery-Mode (WGM) in a cylindrical optical fiber resonator. A nearly linear relationship between the WGM resonance shift and the aerosol coverage ratio of silica nanoparticles (40–50 nm dia.) on the fiber resonator was identified in the low coverage regime. Our experimental results imply sensitivity at the level of ~2 nanoparticles per μm2 deposited on the fiber resonator, which corresponds to pg-level sensitivity in the total aerosol mass within the effective detection area. The response of this fiber optical sensor is further confirmed by using silica nanoparticles deposited on the fiber surface via electrostatic self-assembly. The fiber optical technique for nanoparticle detection may ultimately lead to an instrument capable of real-time in situ aerosol detection with ultrahigh sensitivity.

Copyright © 2016 American Association for Aerosol Research  相似文献   


4.
5.
Four N-donors (PHDA, ATPH, APHO, and MTAN) containing NH2 were used to extract Hg(II), Cd(II), and Pb(II). Their extraction capacity was determined by measurement of percentage extraction.

The chelates extract these metals differently: for example, efficiency of ATPH was the highest for Hg(II) compared to PHDA, APHO, and MTAN.

The extraction efficiency was found to depend on: donor atom hardness, chelate total hardness, metal: chelate mole ratio and substituent’s electronic effects. Among all, total hardness and chelate stability are key factors and molecule of small (EHOMOELUMO) is more reactive, where extraction efficiency increases as molecular stability decreases.  相似文献   


6.
The Fifth Annual Conference on Flame Retardancy was held May 24–26, 1994, at the Ramada Plaza Hotel, Stamford, Connecticut, USA. The conference was organized by Business Communications Company, Inc., Norwalk, Connecticut (Company President, Mr. Louis Naturman; Conference Coordinator, Mrs. Sharon D. Faust). New materials (polymers, blends, composites), their applications, industry developments, and markets were considered. Specifically, the most important topics were:

Introduction of new technological achievements and development in the field of flame retardancy (FR)

Review of the current state of science and technology in FR

Review of applications and markets for FR products

Presentation of recent developments in local and global standardization and in testing technology

Discussion of toxicity and environmental issues

Provision of a unique opportunity for newcomers to FR research technology and marketing to become acquainted with the FR field in all its aspects

Discussion of halogen-based and non-halogen-based flame retardant chemicals, syngergism, intumescence, FR mechanisms, modeling, flame parameters, inherently FR polymers, and polymer blends  相似文献   


7.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


8.
In this work, a mini-CAST soot generator was used to produce soot with different optical and physicochemical characteristics. Absorption Ångström exponents (AAE) expressing the absorption wavelength dependence were assessed by multiwavelength in-situ and filter-based (aethalometer) laser extinction. The two optical techniques showed good agreement. For the chosen mini-CAST operating conditions, AAEs between 1 and 3.5 were found. Soot with high mass-fractions of organic carbon (OC) and pyrolytic carbon (PC) determined with thermal optical analysis were associated with AAEs significantly higher than 1. Heating to 250 and 500°C removed the majority of polycyclic aromatic hydrocarbons. However, the thermal-optical analysis revealed that OC and PC were abundant in the soot with AAE > 2 also after heating the aerosol. Analysis of mass absorption cross section ratios for elemental carbon and OC indicated that elevated AAEs also after heating to 500°C could be related to persistent OC and PC components and/or the refractory soot. By comparing the mini-CAST soot optical properties with soot properties derived from in-situ extinction measurements in a premixed flame, mini-CAST soot with a higher AAE could be identified as less mature soot.

Copyright © 2018 The Authors  相似文献   


9.
10.
Accurate refractive index values are required to determine the effects of aerosol particles on direct radiative forcing. Theoretical retrievals using extinction data alone or extinction plus absorption data have been simulated to determine the sensitivity of each retrieval. A range of aerosol types with a range of different refractive indices were considered. The simulations showed that the extinction-only retrieval was not able to accurately or precisely retrieve refractive index values, even for purely scattering compounds, but the addition of a simulated absorption measurement greatly improved the retrieval.

Copyright 2014 American Association for Aerosol Research  相似文献   


11.
The article presents a mathematical model for calculation of nonstationary hydraulic and separation processes in a gas centrifuge (GC) cascade for separation of multicomponent isotope mixtures. The model has been applied to calculate the parameters of nonstationary processes in a GC cascade for separation of krypton, germanium and tungsten isotopes. As a result, the specifics of the excess holdup distribution along the cascade stages has been identified, and variations of the isotope concentrations in a nonstationary process have been revealed. The data obtained show that the proposed mathematical model is able to adequately describe nonstationary hydraulic processes in GC cascades for separation of multicomponent isotope mixtures.

Highlights:

Mathematical model of cascade for separation of multicomponent isotope mixture has been developed.

The model verification has been done.

The isotope transient regularities into cascade during nonstationary processes has been identified.  相似文献   


12.
The conventional blown process imparts an inherent haze to the product. The percentage of haze varies with certain process variables:

1. Surface irregularities caused by melt flow phenomena

2. Crystallization behavior

3. Melt drawing phenomena in certain types of polyethylene  相似文献   


13.
A novel high-resolution planar and portable differential mobility analyzer (DMA) has been designed and built (Nano-ID® PMC500, Naneum, Canterbury, UK). Finite element multi-physics numerical modeling was employed to optimize the geometry of the DMA and to find a regime for high resolution within the confines of a portable instrument. The numerical approach for solving the Navier–Stokes equation was verified by comparison of calculated data to experimental values. The PMC500 was calibrated and tested with different monodisperse aerosol challenges. The PMC500 portable DMA is shown to have good sizing accuracy and resolution, similar in performance to commercially available desktop instruments.

Copyright 2014 American Association for Aerosol Research  相似文献   


14.
The two corona discharge ozone swimming pool water treatment systems installed in the Peck Aquatic Center in Milwaukee, WI now have been in continuous operation since September, 1987. The two pools are part of the Karl Jewish Campus Facility of the Harold and Judy Sampson Campus of the Milwaukee Jewish Community Center.

The operation of these water treatment systems has shown that safe and high quality pool water is obtained reliably and economically. One pool (Main Pool) is of Olympic size, the other (Learner pool) is designed especially for use by children. Both pools utilize a full corona discharge ozone water treatment system. They were the first ozone systems in the U.S. to be built for public pools using the process of ozonation, flocculation, filtration, ozone removal and residual chlorination.

An extensive testing program was initiated in cooperation with the Wisconsin Department of Health. The bacteriological water quality from these swimming pools was in compliance with Wisconsin State Health Regulations and the German DIN Standard 19,643.

The first year of operation of the Peck Aquatic Center has shown that the corona discharge ozone pool water treatment process can:

1) Operate reliably in a public swimming pool environment without the need for highly or special operator qualifications.

2) Produce continuously bacteria- and virus-free pool water without the harmful and unpleasant effects of chlorine.

3) Creates a user constituency group praising and promoting the use of “minimal chlorine swimming” in the community.  相似文献   


15.
Critical heat flux (CHF) tests were performed to evaluate the effect of dissolved, nonreactive contaminants on low-pressure industrial boilers. These tests were conducted on a 2.38-inch (60.5 mm) I.D. vertical smooth bore tube with nonuniform circumferential heating at pressures between 100 and 500 psia (0.69 and 3.45 MPa). Tests were performed under two water chemistry conditions: clean (less than 1.6 ppm total dissolved solids) and contaminated (greater than 2000 ppm TDS). With all other operating parameters held constant, the following effects of contamination on the steam quality (X) at CHF were determined at the pressures indicated:

At 100 psia (0.69 MPa) Xclean < Xcont

At 300 psia (2.1 MPa) Xclean?Xcont

At 500 psia (3.5 MPa) Xclean > Xcont

The effect of contamination on CHF was found to be a function of pressure, initial contaminant concentration, and the relative steam quality at which CHF conditions occur. These results are compared to data available in the open literature where Xclean is always greater than Xcont. A method for correlating these data is also illustrated.  相似文献   


16.
Objectives: To investigate the effect of different self-etch adhesive systems application techniques: active or passive in a single or double layer on adhesive–dentin microshear bond strength.

Methods: Occlusal surfaces of 48 extracted human molars were ground to expose flat superficial dentin surfaces. Specimens were randomly divided into two main groups according to the tested self-etch adhesive system either: One-step self-etch (AdperTM easy-one) or two-step self-etch (AdperTM SE Plus). Each adhesive system was applied on the prepared dentin surfaces followed one of these techniques: (1) Passive application of a single layer, (2) Active application of single layer, (3) Passive application of double adhesive layer (with light curing in between), and (4) Active application of double adhesive layers. Resin composite was packed inside micro-tubes fixed on the bonded dentin surfaces and light cured for 40 s. All specimens were stored in artificial saliva either for 24 h or 3 months before testing. Microshear bond strength test was employed using a universal testing machine at a crosshead speed of 0.5 mm/min.

Results: AdperTM SE Plus showed higher significant microshear bond strength in compared with AdperTM easy-one. For both adhesive systems active application showed higher significant microshear bond strength to dentin than passive application. Double application of adhesive systems showed lower microshear bond strength than single application.

Conclusion: Active application of self-etch adhesives could improve the dentin microshear bond strength. Double application with curing in between the layers did not improve the bond strength to the tested adhesive.  相似文献   


17.
A butanol-type ultrafine condensation particle counter (UCPC, Model 3776, TSI, Inc., Shoreview, MN, USA), which can achieve a 50% detection efficiency diameter (d50) of 2.5 nm using a capillary-sheath structure, was modified and tested in the laboratory for airborne measurements. The aerosol flow rate through the capillary is a key factor affecting the quantification of aerosol particle number concentrations. A pressure-dependent correction factor for the aerosol flow rate was determined using a newly added mass flow meter for the sheath flow and the external calibration system. The effect of particle coincidence in the optical sensing volume was evaluated using an aerosol electrometer (AE, Model 3068B, TSI, Inc.) as a reference. An additional correction factor for the coincidence effect was derived to improve the quantification accuracy at higher concentrations. The particle detection efficiency relative to the AE was measured for mobility diameters of 3.1–50 nm and inlet absolute pressures of 101–40 kPa. The pressure dependence of the d50 value, asymptotic detection efficiency, and shape of the particle detection efficiency curve is discussed, along with simple theoretical calculations for the diffusion loss of particles and the butanol saturation ratio in the condenser.

© 2017 American Association for Aerosol Science  相似文献   


18.
This work presents the development and characterization of a thermodenuder for the study and interpretation of aerosol volatility. Thermodenuder measurements are further combined with a continuous-flow streamwise thermal gradient CCN counter to obtain the corresponding aerosol hygroscopicity. The thermodenuder response function is characterized with monodisperse aerosol of variable volatility and hygroscopicity. The measurements are then interpreted with a comprehensive instrument model embedded within an optimization framework to retrieve aerosol properties with constrained uncertainty. Special attention is given to the interpretation of the size distribution of the thermodenuded aerosol, deconvoluting the effects of impurities and multiple charging, and to simplifications on the treatment of thermodenuder geometry, temperature, the cooling section, and the effects of curvature and accommodation coefficient on inferred particle volatility. Retrieved vapor pressures are consistent with published literature and shown to be most sensitive to uncertainty in the accommodation coefficient.

Copyright 2014 American Association for Aerosol Research  相似文献   


19.
Many well-established models can be applied to calculate the filtration efficiencies. In these models the filtration velocity and challenging particle size are assumed to be known accurately. However, in realistic filtration tests, the filtration velocity has profiles dependent on the filter holder geometry and experimental conditions; the challenging particles have size distributions dependent on the instruments and operation conditions. These factors can potentially affect the measured filtration efficiency and lead to discrepancies with the models.

This study aims to develop an integrative model to predict the filtration efficiencies in realistic tests by incorporating the effects of the filtration velocity profile and challenging particle size distribution classified by a differential mobility analyzer (DMA) into the existing filtration models. Face velocity profile is modeled with fluid mechanics simulations; the initial generated particle size distribution, the particle charging status and the DMA transfer function are modeled to obtain the challenging particle size distribution. These results are then fed into the filtration models. Simulated results are compared with experimental ones to verify the model accuracy. This model can be used to reduce filtration test artifacts and to improve the experimental procedure.

The results reveal that the face velocity upstream the filter exhibits high degree of homogeneity not affecting the filtration efficiency if the filter pressure drop is not very low. The generated particle size distribution and the DMA selection size window could influence the challenging particle size distribution and therefore the measured filtration efficiency.

Copyright © 2017 American Association for Aerosol Research  相似文献   


20.
Aerosols are important atmospheric constituents as they impact the Earth's energy balance and climate. An analysis of the impact of aerosols depends on the detailed knowledge of aerosol optical properties. However, there is a lack of refractive index data for atmospherically relevant organic compounds in the infrared (IR) region which complicates the quantitative estimation of the aerosol influence on the radiative balance. In this study, we investigate the optical properties of atmospherically relevant carboxylic acids and HUmic-LIke Substances (HULIS) proxies. Aerosol size distributions are measured simultaneously with Fourier transform infrared (FTIR) extinction spectra to calculate the complex refractive index. Scanning electron microscopy (SEM) images are also collected to investigate particle shape. Analysis of SEM images shows evidence for agglomeration in some cases. The experimentally measured IR resonances do not appear to be highly sensitive to agglomeration effects. However, there is an increase in the scattering efficiency at shorter wavelengths as the result of larger overall particle size of the agglomerates. Refractive indices are retrieved from the IR extinction spectra of organic acids and HULIS proxies. Mie simulation results confirm the quality of the retrieved optical constants. Interestingly, the optical constants determined for the acids are in agreement with the published data for fire smoke plumes.

Copyright 2014 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号