首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
《Energy Conversion and Management》2005,46(15-16):2530-2552
This paper is concerned with the energy and exergy analyses of the single layer drying process of potato slices via a cyclone type dryer. Using the first law of thermodynamics, an energy analysis was performed to estimate the ratios of energy utilization. An exergy analysis was accomplished to determine the location, type and magnitude of the exergy losses during the drying process by applying the second law of thermodynamics. It was concluded that the exergy losses took place mostly in the 1st tray where the available energy was less utilized during the single layer drying process of potato slices. It is emphasized that the potato slices are sufficiently dried in the ranges between 60 and 80 °C and 20–10% relative humidity at 1 and 1.5 ms−1 of drying air velocity during 10–12 h despite the exergy losses of 0–1.796 kJ s−1.  相似文献   

2.
The process of charging of an encapsulated ice thermal energy storage device (ITES) is thermally modeled here through heat transfer and thermodynamic analyses. In heat transfer analysis, two different temperature profile cases, with negligible radial and/or stream-wise conduction are investigated for comparison, and the temperature profiles for each case are analyzed in an illustrative example. After obtaining temperature profiles through heat transfer analysis, a comprehensive thermodynamic study of the system is conducted. In this regard, energy, thermal exergy and flow exergy efficiencies, internal and external irreversibilities corresponding to flow exergy, as well as charging times are investigated. The energy efficiencies are found to be more than 99%, whereas the thermal exergy efficiencies are found to vary between 40% and 93% for viable charging times. The flow exergy efficiency varies between 48% and 88% for the flows and inlet temperatures selected. For a flow rate of 0.00164 m3/s, the maximum flow exergy efficiency occurs with an inlet temperature of 269.7 K, corresponding to an efficiency of 84.3%. For the case where the flow rate is 0.0033 m3/s, the maximum flow exergy efficiency becomes 87.9% at an inlet temperature of 270.7 K. The results confirm the fact that energy analyses, and even thermal exergy analyses, may lead to some unrealistic efficiency values. This could prove troublesome for designers wishing to optimize performance. For this reason, the flow exergy model provides the most useful information for those wishing to improve performance and reduce losses in such ITES systems.  相似文献   

3.
The energy and exergy analyses of the drying process of olive mill wastewater (OMW) using an indirect type natural convection solar dryer are presented. Olive mill wastewater gets sufficiently dried at temperatures between 34 °C and 52 °C. During the experimental process, air relative humidity did not exceed 58%, and solar radiation ranged from 227 W/m2 to 825 W/m2. Drying air mass flow was maintained within the interval 0.036–0.042 kg/s. Under these experimental conditions, 2 days were needed to reduce the moisture content to approximately one-third of the original value, in particular from 3.153 gwater/gdry matter down to 1.000 gwater/gdry matter.Using the first law of thermodynamics, energy analysis was carried out to estimate the amounts of energy gained from solar air heater and the ratio of energy utilization of the drying chamber. Also, applying the second law, exergy analysis was developed to determine the type and magnitude of exergy losses during the solar drying process. It was found that exergy losses took place mainly during the second day, when the available energy was less used. The exergy losses varied from 0 kJ/kg to 0.125 kJ/kg for the first day, and between 0 kJ/kg and 0.168 kJ/kg for the second. The exergetic efficiencies of the drying chamber decreased as inlet temperature was increased, provided that exergy losses became more significant. In particular, they ranged from 53.24% to 100% during the first day, and from 34.40% to 100% during the second.  相似文献   

4.
A thermal network model is developed to predict the performance of latent heat thermal energy storage (LHTES) systems including cascaded phase change materials (PCMs) and embedded heat pipes/thermosyphons. Because the design of LHTES systems involves a compromise between the amount of energy stored, the heat transfer rate, and the quality of the released thermal energy, an exergy analysis is also carried out to identify the preferred LHTES design. It is found that the LHTES with the lowest melting temperature PCM yields the highest exergy efficiency. However, a cascaded LHTES recovers the largest amount of exergy during a 24 h charging–discharging cycle. Quantitatively, the cascaded LHTES recovers about 10% more exergy during a 24 h charging–discharging cycle compared to the best non-cascaded LHTES considered in this work.  相似文献   

5.
Fluid mechanics and heat transfer are studied in a double-tube heat exchanger that uses the combustion gases from natural gas in a porous medium located in a cylindrical tube to warm up air that flows through a cylindrical annular space. The mathematical model is constructed based on the equations of continuity, linear momentum, energy and chemical species. Unsteady fluid mechanics and heat transfer by forced gas convection in the porous media, with combustion in the inner tube, coupled to the forced convection of air in the annular cylindrical space are predicted by use of finite volumes method. Numerical simulations are made for four values of the annular air flow Reynolds number in the range 100 ? Re ? 2000, keeping constant the excess air ψ = 4.88, the porosity ε = 0.4, and the air–fuel mixture inlet speed Uo = 0.43 m/s. The results obtained allow the characterization of the velocity and temperature distributions in the inner tube and in the annular space, and at the same time to describe the displacement of the moving combustion zone and the annular porous media heat exchanger thermal efficiency. It is concluded that the temperature increase is directly related to the outer Reynolds number.  相似文献   

6.
This study addresses the thermo-economic assessment of a mid-scale (20 MWth,wood) wood gasification, gas cleaning and energy conversion process, with particular attention given to electricity generation costs and tar control. Product distributions were estimated with a parametric stoichiometric equilibrium model calibrated using atmospheric air gasification data. A multi-objective optimisation problem was defined for a superstructure of alternative energy flow diagrams for each processing step. The trade-off between total investment costs and the exergy efficiency of electricity production was obtained, and analysed to identify operating conditions that minimise tar formation to prevent equipment fouling. The use of air, oxygen or steam fluidised bed gasifiers, closed coupled to an internal combustion engine combined cycle (ICE-CC) requiring cold gas cleaning, or gas turbine combined cycle (GT-CC) requiring hot gas cleaning have been considered. The operating conditions that maximise ICE-CC efficiency with cold gas cleaning (low pressure and high temperatures) also favour minimal tar formation. For GT-CC tar concentrations are higher, but this should not be of concern provided that hot gas cleaning can effectively prevent tar condensation. The trade-off appears to be optimal for steam gasification, with minimal specific costs of 2.1 €/We for GT-CC, and 2.7 €/We for ICE-CC. However, further calibration of the reaction model is still needed to properly assess product formation for other oxidants than air, and to properly take account of the impact of pressure on product distributions. For air gasification, the minimal specific cost of GT-CC is 2.5 €/We, and that of ICE-CC 3.1 €/We.  相似文献   

7.
In this study, the energy and exergy analysis of Al-Hussein power plant in Jordan is presented. The primary objectives of this paper are to analyze the system components separately and to identify and quantify the sites having largest energy and exergy losses. In addition, the effect of varying the reference environment state on this analysis will also be presented. The performance of the plant was estimated by a component-wise modeling and a detailed break-up of energy and exergy losses for the considered plant has been presented. Energy losses mainly occurred in the condenser where 134 MW is lost to the environment while only 13 MW was lost from the boiler system. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system (77%) followed by the turbine (13%), and then the forced draft fan condenser (9%). In addition, the calculated thermal efficiency based on the lower heating value of fuel was 26% while the exergy efficiency of the power cycle was 25%. For a moderate change in the reference environment state temperature, no drastic change was noticed in the performance of major components and the main conclusion remained the same; the boiler is the major source of irreversibilities in the power plant. Chemical reaction is the most significant source of exergy destruction in a boiler system which can be reduced by preheating the combustion air and reducing the air–fuel ratio.  相似文献   

8.
In this paper, overall thermal energy and exergy analysis has been carried out for different configurations of hybrid photovoltaic thermal (PVT) array. The hybrid PVT array (10.08 m × 2.16 m) is a series and parallel combinations of 36 numbers of PV modules. A one-dimensional transient model for hybrid PVT array has been developed using basic heat transfer equations. On the basis of this transient model, an attempt has been made to select an appropriate hybrid PVT array for different climatic conditions (Bangalore, Jodhpur, New Delhi, and Srinagar) of India. On the basis of high grade energy (i.e. overall exergy gain), case-III has been selected as the most appropriate configuration because overall exergy for case-III is 12.9% higher than case-II. The overall thermal energy and exergy gain for Bangalore is 4.54 × 104 kW h and 2.07 × 104 kW h respectively which is highest in comparison to the other cities.  相似文献   

9.
This paper presents a novel polygeneration system that integrates the acetylene process and the use of fuel cells. The system produces acetylene and power by a process of the partial oxidation/combustion (POC) of natural gas process, a water–gas shift reactor, a fuel cell and a waste heat boiler auxiliary system to recover the exhaust heat and gas from the fuel cell. Based on 584.3 kg/h of natural gas feedstock, a POC reactor temperature of 1773 K, an absorber pressure of 1.013 MPa and a degasser pressure of 0.103 MPa, the simulation results show that the new system achieved acetylene production of 1.9 MW, net electricity production of 1.7 MW, power generation efficiency of 26.8% and exergy efficiency of 43.4%, which was 20.2% higher than the traditional acetylene production process. The new system's exergy analysis and the flow rate of the products were investigated, and the results revealed that the energy conversion and systematic integration mechanism demonstrated the improvement of natural gas energy conversion efficiency.  相似文献   

10.
In this study energy, exergy and exergoeconomic analysis of the Afyon geothermal district heating system (AGDHS) in Afyon, Turkey is performed through thermodynamic performances and thermo-economic assessments. In the analysis, actual system data are used to assess the district heating system performance, energy and exergy efficiencies, exergy losses and loss cost rates. Energy and exergy losses throughout the AGDHS are quantified and illustrated in the flow diagram. The energy and exergy efficiencies of the overall system are found to be 37.59% and 47.54%, respectively. The largest exergy loss occurs in the heat exchangers with 14.59% and then in the reinjection wells with 14.09%. Besides, thermo-economic evaluations of the AGDHS are given in table. Energy and exergy loss rates for the AGDHS are estimated to be 5.36 kW/$ and 0.2  kW/$, respectively.  相似文献   

11.
《Energy Conversion and Management》2005,46(11-12):1692-1702
Performance of an actual Diesel engine power plant with a rated output of 120 MW is analyzed based on the first and second laws of thermodynamics. The plant consists of seven identical Diesel engines and various subsystems including turbochargers, fuel heating units and heat exchangers performing various useful tasks. The engine runs on heavy fuel oil, and the pollutant emissions from the engine are greatly reduced by effective treatment systems. The characteristics and performance parameters of the internal combustion engines of the plant are evaluated. The mass, energy and exergy balances are verified for each flow stream in the power plant. The work and heat interactions, the exergy losses and the efficiencies of various components based on both energy and exergy concepts are evaluated. The thermal and the exergy efficiencies of the plant are determined to be 47% and 44%, respectively. The engine irreversibilities are due mostly to the irreversible combustion process and account for 32% of the total exergy input and 57% of the total irreversibilities in the plant. Most of the remaining irreversibilities in the plant occur in the desulphurization, intercooler, compressor and lubrication oil cooler units. The results should provide a realistic and meaningful ground for the performance evaluation of Diesel engine power units, and it may be used in the design and analysis of such systems.  相似文献   

12.
In this paper, a study is carried out to evaluate the annual thermal and exergy performance of a photovoltaic/thermal (PV/T) and earth air heat exchanger (EAHE) system, integrated with a greenhouse, located at IIT Delhi, India, for different climatic conditions of Srinagar, Mumbai, Jodhpur, New Delhi and Bangalore. A comparison is made of various energy metrics, such as energy payback time (EPBT), electricity production factor (EPF) and life cycle conversion efficiency (LCCE) of the system by considering four weather conditions (a–d type) for five climatic zones. The embodied energy and annual energy outputs have been used for evaluation of the energy metrics. The annual overall thermal energy, annual electrical energy savings and annual exergy was found to be best for the climatic condition of Jodhpur at 29,156.8 kWh, 1185 kWh and 1366.4 kWh, respectively when compared with other weather stations covered in the study, due to higher solar intensity I and sunshine hours, and is lowest for Srinagar station. The results also showed that energy payback time for Jodhpur station is lowest at 16.7 years and highest for Srinagar station at 21.6 years. Electricity production factor (EPF) is highest for Jodhpur, i.e. 2.04 and Life cycle conversion efficiency (LCCE) is highest for Srinagar station. It is also observed that LCCE increases with increase in life cycle.  相似文献   

13.
In this paper, an exergoeconomic analysis has been carried out and on the basis of this analysis it has been concluded that in terms of energy saving the glazed hybrid photovoltaic thermal (PVT) module air collector offers a greater potential compared to PV module. The experimental validation for glazed hybrid PVT module air collector has also been performed and it has been observed that there is a good agreement between the theoretical and experimental values with correlation coefficient in range of 0.96–0.99 and root mean square percentage deviation in range of 2.38–7.46. The experiments have been carried out on clear days during the month July 2010 to June 2011. For the validation of theoretical results with experimental results, a typical day of winter month (December 08, 2010) and summer month (April 11, 2011) has been considered. An experimental uncertainty for December and April month is 11.6% and 2.1% respectively. The annual overall thermal energy and exergy gain are 1252.0 kWh and 289.5 kW h respectively. The annual net electrical energy savings by glazed hybrid PVT module air collector is 234.7 kW h.  相似文献   

14.
Hot tips are used either for characterizing nanostructures by using scanning thermal microscopes or for local heating to assist data writing. The tip-sample thermal interaction involves conduction at solid–solid contact as well as conduction through the ambient gas and through the water meniscus. We analyze those three heat transfer modes with experimental data and modeling. We conclude that the three modes contribute in a similar manner to the thermal contact conductance but they have distinct contact radii ranging from 30 nm to 1 μm. We also show that any scanning thermal microscope has a 1–3 μm resolution when used in ambient air.  相似文献   

15.
《Biomass & bioenergy》2006,30(1):58-65
The combination of energy production from biomass with phytoremediation opens perspectives for bringing land with moderate metal contamination into safe and beneficial use. Small scale fixed bed downdraft gasifier installations (150 kWe–1 MWe) can be employed for on-site conversion of biomass to electricity and heat. To assess the fate of heavy metals, batch gasification operations were run in a small scale fixed bed downdraft gasifier (100 kW thermal power). The gasification of 1 kg of wood resulted in the production of 40 g of ashes, 1.2 kWh of electricity and 9 MJ of heat. Per kg dry mass of willow wood, 31 g bottom ashes, 7 g cyclone ashes, 2 g filter ashes, and 18 g DM of gasifier bed ashes were produced. Cd, Zn and Pb were enriched by a factor 7–100 in the fly ashes compared to the bottom ashes. Low mass recoveries (30–40%) were found for Cd, Cr, Ni and Pb. This was mainly attributed to measurement uncertainties. 60% and more of recovered Cd, Pb and Zn were present in the finer filter and cyclone ashes, while Cr, Cu and Ni were mainly found in the bottom ashes and to a lesser extent the bed ashes. The scrubber placed after the hot cyclone has an essential role in intercepting the more volatile heavy metals before combustion of the gas. The bottom ashes constituted the largest fraction and ideally should be recycled if limits for metal contents are met. Only Cd and Zn exceeded Flemish threshold values for use of this fraction as a fertilizer, albeit by a small margin. This leaves perspectives for future research to optimise process parameters towards the production of bottom ashes that can be recycled.  相似文献   

16.
《Exergy》2002,2(2):113-118
In this study, an exergoeconomic analysis of condenser type parallel flow heat exchangers is presented. Exergy losses of the heat exchanger and investment and operation expenses related to this are determined with functions of steam mass flow rate and water exit temperature at constant values of thermal power of the heat exchanger at 75240 W, cold water mass flow rate and temperature. The inlet temperature of water is 18 °C and exit temperatures of water are varied from 25 °C to 36 °C. The values of temperature and pressure of saturated steam in the condenser are given to be Tcon=47 ° C and Pcon=10.53 kPa. Constant environment conditions are assumed. Annual operation hour and unit price of electrical energy are taken into account for determination of the annual operation expenses. Investment expenses are obtained according to the variation of heat capacity rate and logarithmic mean temperature difference and also heat exchanger dimension determined for each situation. The present analysis is hoped to be useful in determining the effective parameters for the most appropriate exergy losses together with operating conditions and in finding the optimum working points for the condenser type heat exchangers.  相似文献   

17.
Numerical simulations of three configurations of a modified Trombe-Michel Wall (TMW) are carried out and the numerical results are employed to carry on the energy and exergy analyses. The three configurations of the modified Trombe-Michel Wall (TMW) investigated are with sharp edges, with rounded edges and with the guided flow. For each configuration and glaze spacing, spanning from 0.1 m up to 0.5 m, the velocity and the mean air temperature in the channel, the heat flux, the exergy gain and the conductive heat transfer through the massive wall are evaluated numerically. The comparison among the three configurations shows that the guided flow presents the highest energy and exergy efficiency.  相似文献   

18.
Concentrating solar thermal systems offer a promising method for large scale solar energy collection. Although concentrating collectors are generally thought of as large-scale stand-alone systems, there is a huge opportunity to use novel concentrating solar thermal systems for rooftop applications such as domestic hot water, industrial process heat and solar air conditioning for commercial, industrial and institutional buildings. This paper describes the thermal performance of a new low-cost solar thermal micro-concentrating collector (MCT), which uses linear Fresnel reflectors, and is designed to operate at temperatures up to 220 °C. The modules of this collector system are approximately 3 m long by 1 m wide and 0.3 m high. The objective of the study is to optimise the design to maximise the overall thermal efficiency. The absorber is contained in a sealed enclosure to minimise convective losses. The main heat losses are due to natural convection inside the enclosure and radiation heat transfer from the absorber tube. In this paper we present the results of a computational and experimental investigation of radiation and convection heat transfer in order to understand the heat loss mechanisms. A computational model for the prototype collector has been developed using ANSYS–CFX, a commercial computational fluid dynamics software package. The numerical results are compared to experimental measurements of the heat loss from the absorber, and flow visualisation within the cavity. This paper also presents new correlations for the Nusselt number as a function of Rayleigh number.  相似文献   

19.
Solar thermal collectors have significant importance due to its wide use in solar thermal technology. Augmentation of heat transfer is a key challenge for solar thermal technology. A quarter circular solar thermal collectors is investigated throughout the paper introducing carbon nanotube (CNT)–water nanofluid in the cavity. Tilt angle of this type of collector plays a vital role and heat transfer can be maximized for a particular tilt angle and solid volume fraction of the nanofluid. Galerkin weighted residual of FEM has been applied for the numerical solution of the problem. Grid independency test and code validation have been assessed for the accuracy of numerical solution. In this paper a wide range of solid volume fraction (δ = 0 to δ = 0.12) and tilt angle (ϕ = 0 to ϕ = 60°) has been investigated for Rayleigh number (Ra = 105–108) with varying dimensionless times. It has been found that both solid volume fraction and tilt angle play vital roles for the augmentation of heat transfer and a good heat transfer characteristic can be obtained by compromising between these two parameters. The results are shown using streamline, isotherm contour and related graph and chart.  相似文献   

20.
In this research, poplar and pine timbers have been dried from the moisture contents of 1.28 kg water/kg dry matter and 0.60 kg water/kg dry matter to 0.15 kg water/kg dry matter in heat pump dryer functioning on the basis of 24 h operation. The change in weight in all of the timbers was followed in the drying chamber and drying stopped when the desired weight was achieved. At 40 °C dry bulb temperature, 0.8 m/s air velocity, and initial moisture content of the poplar timbers 1.28 kg water/kg dry matter, the moisture content was reduced to 0.15 kg water/kg dry matter moisture content in 70 h, and the moisture content of the pine timbers which was 0.60 kg water/kg dry matter was reduced to the same amount in 50 h. All data collected while drying were saved on computer and analysed afterwards. For this system, energy analysis was made to determine the energy utilization. Exergy analysis was accomplished to determine of exergy losses during the drying process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号