Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model. The model was validated using a wide range of operating data from an existing chiller with specific settings of outdoor temperature and condensing pressure in controlling the condensing temperature. The validated model was developed specifically to ascertain the maximum coefficient of performance of chiller (COP) together with the strategy for optimizing the condensing temperature under various operating conditions. It is found that the highest COP occurs at a part load ratio (PLR) of 0.71–0.84, depending on the outdoor temperature and the control of condensing temperature, rather than at full load. Yet the chillers operating at such part load conditions will cause extra energy used for the early staging of chilled water pumps. To minimize the overall chiller plant energy consumption, it is still preferable to implement chiller sequencing based on the full load condition than on the aforementioned PLRs. The results of this paper present criteria for implementing low-energy strategies for operating air-cooled chillers satisfying a given building cooling load profile. 相似文献
2.
3.
针对相关文献关于常规冷水机组、高温冷水机组在高出水温度工况下的能效特性评价及对比研究方面的认识误区进行了分析.建议采用热力完善度来比较以上两种机组在同一出水温度工况下的能效特性,认为相关文献所研发的高温离心冷水机组能效特性并不优于现有的常规离心冷水机组. 相似文献
4.
5.
Air-cooled chillers are widely used to provide cooling energy for air-conditioned buildings at the expense of considerable electricity. The (Air-Conditioning & Refrigeration Institute) ARI standard 550/590 sets out a rating condition to specify the coefficient of performance (COP) of the chillers under part-load conditions. This condition was found to be insufficient to deal with diverse operating conditions under the multiple chiller arrangement. This paper proposes an alternative approach to specifying more precisely the chiller COP under part-load conditions. It is desirable to establish a set of part-load performance curves showing how the chiller COP varies with the condensing temperature at various combinations of chiller loads and outdoor temperatures. The results of this paper will give engineers and researchers a better idea about how to specify the upper limit of condensing temperature for more energy efficient chillers and how chiller COP curves help compare air-cooled chillers for buildings in any climate zone and to estimate the annual electricity consumption of chillers satisfying any given building cooling load profile. 相似文献
6.
Air-cooled chillers are commonly used to provide cooling energy for air-conditioned buildings at the expense of considerable electricity. This paper examines the life cycle electricity cost of these chillers with the improved condenser features of condensing temperature control (CTC), evaporative pre-coolers (EC) and variable speed condenser fans (VSF). A validated model for an air-cooled screw chiller was used to ascertain how the individual and mixed features influence the annual electricity consumption of chillers in various operating conditions. It is estimated that the life cycle electricity cost savings range from HK$ 2,099,742 with EC to HK$ 6,399,564 with all the three features, with regard to a chiller plant serving an office building for 15 yr. The life cycle analysis reported here provides important insights into how to reap the benefits of energy efficient technologies for air-cooled chillers. 相似文献
7.
《Building and Environment》2005,40(1):143-151
This paper presents the operating efficiency of air-cooled chillers in three existing hotels and investigates the extent to which the annual electricity consumption can decrease by improving their efficiency. Chillers in these hotels tend to be improperly staged, causing their seasonal efficiency to rise by 0.05–0.12 kW/kW from a full load efficiency of 0.32 kW/kW. When chiller sequencing is restored, their seasonal efficiency could be enhanced to 0.34 kW/kW, which corresponds to an 8.8–22.7% drop in their annual electricity consumption. It is possible to further decrease the annual electricity consumption by 27.0–38.6% when the chillers operate under floating condensing temperature control instead of head pressure control. The implications of improved chiller efficiency for reducing the electricity demand of hotels are discussed. 相似文献
8.
9.
10.
11.
12.
Shading is a technique used to reduce the cooling demand in buildings and save energy. This paper investigates the possibility of reducing the electrical demand and saving energy by shading the condensers of air-conditioning (A/C) equipment. A limiting analysis compares the performance of several A/C systems with ideal shade to those with ideal solar heat gain. The comparison is based on a theoretical model and data from equipment catalogs. The results show that the theoretical increase in the coefficient of performance (COP) due to shading is within 2.5%. Furthermore, this small improvement in ideal efficiency decreases at higher ambient temperatures, when enhancements to efficiency are more needed. A sensitivity analysis shows that the small COP enhancement is not significantly affected by assumed variables. The actual efficiency improvement due to shading is not expected to exceed 1%, and the daily energy savings will be lower. The findings indicate that condenser shading alone, without evapo-transpiration, is not an effective measure to improve efficiency or save energy. 相似文献
13.
14.
15.
16.
风冷热泵机组环境温度使用范围及除霜技术 总被引:6,自引:2,他引:6
本文讨论了风冷热泵机组在规定环境温度下以及更低环境温度条件下制热能力的相对变化和膨胀阀的对应变化,提出在低温环境下风冷热泵机组系统设计方案,并结合际详细介绍了风冷热泵机组除霜技术与经验数据。 相似文献
17.
18.
《Energy and Buildings》2005,37(7):739-746
This paper investigates how energy signatures can be used as an alternative to an energy use intensity (describing the annual electricity consumption of chillers in kWh per unit floor area of a building in m2) to assess the energy performance of chillers with various design options and operating strategies. An energy signature is a best-fit straight line relating chiller power to a climatic index when chillers operate for a building cooling load profile. Sixteen combinations of four design options and four operating strategies for chillers serving a hypothetical hotel are studied by simulation. For each combination, an energy signature for the chillers is determined. The slope and intercept of the energy signature can be used to accurately predict the annual electricity consumption of the chillers and to evaluate the extent to which this consumption can drop when chiller efficiency is improved. It is desirable to develop reference energy signatures in relation to different characteristics of building cooling load as a yardstick for the minimum requirement of chiller performance. With this yardstick, the effectiveness of energy efficient measures in the operation of chillers could be identified. 相似文献
19.
As thermal insulation improves so ventilation losses assume crucial importance for energy economy. In temperate climates this factor is closely related to moisture and temperatures in the home. Since ventilation control is never easy, moisture generation can be controlled by heat pumps, which are already used for this purpose in Italy, Japan and the USA. But their potential could be greatly increased if they incorporate counterflow air/air heat exchangers, as described here. 相似文献