首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Journal of power sources》2006,160(1):474-484
This paper presents a techno-economic analysis of fuel-cell-based auxiliary power units (APUs), with emphasis on applications in the trucking industry and the military. The APU system is intended to reduce the need for discretionary idling of diesel engines or gas turbines. The analysis considers the options for on-board fuel processing of diesel and compares the two leading fuel cell contenders for automotive APU applications: proton exchange membrane fuel cell and solid oxide fuel cell. As options for on-board diesel reforming, partial oxidation and auto-thermal reforming are considered. Finally, using estimated and projected efficiency data, fuel consumption patterns, capital investment, and operating costs of fuel-cell APUs, an economic evaluation of diesel-based APUs is presented, with emphasis on break-even periods as a function of fuel cost, investment cost, idling time, and idling efficiency. The analysis shows that within the range of parameters studied, there are many conditions where deployment of an SOFC-based APU is economically viable. Our analysis indicates that at an APU system cost of $ 100 kW−1, the economic break-even period is within 1 year for almost the entire range of conditions. At $ 500 kW−1 investment cost, a 2-year break-even period is possible except for the lowest end of the fuel consumption range considered. However, if the APU investment cost is $ 3000 kW−1, break-even would only be possible at the highest fuel consumption scenarios. For Abram tanks, even at typical land delivered fuel costs, a 2-year break-even period is possible for APU investment costs as high as $ 1100 kW−1.  相似文献   

2.
This paper presents an assessment of the productive efficiency of an advanced biodiesel plant in Japan using Data Envelopment Analysis (DEA). The empirical analysis uses monthly input data (waste cooking oil, methanol, potassium hydroxide, power consumption, and the truck diesel fuel used for the procurement of waste cooking oil) and output data (biodiesel) of a biodiesel fuel plant for August 2008–July 2010. The results of this study show that the production activity with the lowest cost on the biodiesel production possibility frontier occurred in March 2010 (production activity used 1.41 kL of waste cooking oil, 0.18 kL of MeOH, 16.33 kg of KOH, and 5.45 kW h of power), and the unit production cost in that month was 18,517 yen/kL. Comparing this efficient production cost to the mean unit production cost on the production possibility frontier at 19,712 yen/kL, revealed that the cost of producing 1 kL of biodiesel could be reduced by as much as 1195 yen. We also find that the efficiency improvement will contribute to decreasing the cost ratio (cost per sale) of the biodiesel production by approximately 1% during the study period (24 months) between August 2008 and July 2010.  相似文献   

3.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

4.
A detailed analysis of the heating and cooling performance of environmental heat sources and sinks is presented for 12 low-energy buildings in Germany. In particular, the analysis focuses on the given temperature levels and the efficiency performance of the environmental heat sources and sinks in summer and winter. The investigated buildings employ environmental heat sources and sinks – such as the ground, groundwater, rainwater and the ambient air – in combination with thermo-active building systems (TABS). These concepts are promising approaches for slashing the primary energy use of buildings without violating occupant thermal comfort. A limited primary energy use of about 100 kW hprim/(mnet2 a) as a target for the complete building service technology (HVAC and lighting) was postulated for all buildings presented. With respect to this premise, comprehensive long-term monitoring in fine time-resolution occurred over a period from two to five years. An accompanying commissioning of the building performance took place. Measurements include water supply and return temperatures of the environmental heat sources/sinks, the generated heating and cooling energy, efficiencies of the system, and local climatic site conditions. The comparative evaluation of the systems in all buildings identifies weak points and success factors of the plant. Besides, it characterizes the single component and points out further potential for optimization measures. The annual efficiency performance of the geothermal heat sources and sinks results in a seasonal performance factor of 8–10 kW htherm/kW hend, where the end energy use is electricity. The ground, groundwater, rainwater and even the ambient air constitute efficient heat sources/sinks. Energy is needed only for distributing the heat and cold and not for its generation. The choice of suitable plant components, the accurate design of the hydraulic system and the correct dimension of the environmental heat source/sink play a central role in achieving higher efficiencies.  相似文献   

5.
《Biomass & bioenergy》2007,31(4):177-185
Three different scenarios of switchgrass (Panicum virgatum L.) cultivation (high, mild and low) in two different environmental conditions (North and South Italy) were economically analysed by the computerized model BEE. The dataset was mostly generated from an 8.6 ha field of switchgrass planted in 2002 at the University of Bologna (North Italy). Annual equivalent costs (AEC) and break-even yield (BEY, i.e. the dry matter yield at which cost equals selling price) of each scenario were calculated to assess the feasibility of each scenario. AEC ranged from €511 to €1.257 ha−1 being always higher in northern than southern regions. As expected, BEY varied to an extent depending on input levels. BEY was clearly higher under intensive cropping systems (HS) compared to mild-(MS) and low-input (LS) scenarios. However, even for MS or LS, BEY generally exceeded the harvested yield. Therefore, we can conclude that, at the market price of €55 Mg−1 (dry basis), switchgrass can be hardly grown both in North and South Italy. However, the biomass market price appeared surprisingly underestimated if compared to the unit energy price of crude oil, therefore a desirable increase of biomass price could be expected in the next few years. Sensitivity analysis showed that biomass price strongly affects BEY, and this was especially found in HS. Furthermore, the differences in BEY between LS and HS clearly decreased with increasing market prices. Therefore, HS could be better indicated than LS at high market prices. Switchgrass was found to be more profitable than some conventional crops to an extent depending on the yield higher than BEY (Yi). At the current biomass price, Yi was from less than 1 Mg ha−1 (maize and alfalfa) to more than 4 Mg ha−1 (sugarbeet).  相似文献   

6.
《Journal of power sources》2006,159(2):1194-1204
The main objective of this study is to develop the synthesis and optimization of reactor-separation network (RSN) models that can be simultaneously solved within Non-Linear Programming (NLP) for a PEM fuel cell system. The objective function for optimization was defined to minimize the overall cost and CO production. Five alternatives were synthesized to determine the best flow chart for the system based on cost and the output concentration of carbon monoxide. A Polymer Electrolyte Membrane Fuel Cell (PEMFC) system was taken as the case study. The results indicated that the optimum specific cost of a PEMFC stack was found to be in the region of US$ 500–700 kW−1, while the specific manufacturing cost and the specific investment cost were calculated at the range of US$ 1000–1500 and 2500–3000 kW−1, respectively. Furthermore, the infrastructure investment cost was determined to be in the range of US$ 10–30 billion with the specific cost for one unit in the range of US$ 2000–4000 kW−1. The results obtained are comparable with other studies.  相似文献   

7.
The present cost of fuel cells estimated at about $200 kW−1 is a major barrier for commercialization and use in automotive applications. In the United States the target costs for fuel cell systems for the year 2004 as formulated by PNGV are $50 kW−1. Lomax et al. have estimated the costs of polymer electrolyte membrane (PEM) fuel cells to be as low as $20 kW−1. These estimates are based on careful consideration of high volume manufacturing processes. Recently, Arthur D. Little (ADL) has estimated the cost of a fuel cell system for transportation at $294 kW−1. This estimate considers a fuel processor and directly related balance of plant components. The difference of the cost estimates results from the vastly different design assumptions. Both of these estimates are based on considering a single high volume of production, 500,000 fuel cells per year. This work builds on these earlier estimates by employing the methods of technical cost modeling and thereby including explicit consideration of design specifications, exogenous factor cost and processing and operational details. The bipolar plate is analyzed as a case study. The sensitivity of the costs to uncertainty in process conditions are explored following the ADL design. It is shown that the PNGV targets can only be achieved with design changes that reduce the quantity of material used. This might necessitate a reduction in efficiency from the assumed 80 mpg.  相似文献   

8.
The advent of large samples of smart metering data allows policymakers to design Feed-in Tariffs which are more targeted and efficient. This paper presents a methodology which uses these data to design FITs for domestic scale grid-connected PV systems in Ireland. A sample of 2551 household electricity demand data collected at 1/2-hourly intervals, electricity output from a 2.82 kWp PV system over the same time interval as well as PV system costs and electricity tariffs were used to determine the required FIT to make it worthwhile for the households to invest in the PV system. The methodology shows that it is possible to design single, multiple and continuous FITs. Continuous FITs are the most efficient and result in no overcompensation to the housholder while single and multiple FITs are less efficient since they result in different levels of overcompensation. In the PV case study considered, it was shown that the use of three FITs (0.3170, 0.3315 and 0.3475 €/kW h) resulted in a 59.6% reduction in overcompensation compared to a single FIT of 0.3475 €/kW h; assuming immediate and complete uptake of the technology, this would result in NPV savings of over €597 m to the Irish government over a 25 year lifetime.  相似文献   

9.
Rustu Eke  Ali Senturk 《Solar Energy》2012,86(9):2665-2672
In the present study, performance results of two double axis sun tracking photovoltaic (PV) systems are analyzed after one year of operation. Two identical 7.9 kWp PV systems with the same modules and inverters were installed at Mugla University campus in October 2009. Measured data of the PV systems are compared with the simulated data. The performance measurements of the PV systems were carried out first when the PV systems were in a fixed position and then the PV systems were controlled while tracking the sun in two axis (on azimuth and solar altitude angles) and the necessary measurements were performed. Annual PV electricity yield is calculated as 11.53 MW h with 1459 kW h/kWp energy rating for 28 fixed tilt angle for each system. It is calculated that 30.79% more PV electricity is obtained in the double axis sun-tracking system when compared to the latitude tilt fixed system. The annual PV electricity fed to grid is 15.07 MW h with 1908 kW h/kWp for the double axis sun-tracking PV system between April-2010 and March-2011. The difference between the simulated and measured energy values are less than 5%. The results also allow the comparison of different solutions and the calculation of the electricity output.  相似文献   

10.
E.M. Nfah  J.M. Ngundam 《Solar Energy》2012,86(10):2935-2949
Photovoltaic hybrid systems (PVHS) with 2 days of energy autonomy are shown to be optimal options for the supply of the daily energy demands of 33 base transceiver stations of MTN Cameroon. PVHS were computed for all sites using the technical data for a 150 Wp mono-crystalline module, the site specific hourly load data, the average monthly solar radiation and temperature. Hourly solar radiation data for all sites were downloaded using the solar resource module of HOMER and geographical coordinates of the selected sites. The 3-hourly temperature data available on a website maintained NASA was used to generate average monthly hourly temperatures needed in the calculation of the output of solar modules. The energy costs and breakeven grid distances for possible power options were computed using the Net Present Value Technique and financial data for selected power system components. The results with a PV module cost of 7.5 €/Wp, a remote diesel price of 1.12 €/l, a general inflation rate of 5% and a fuel escalation of 10% showed that the annual operational times of the diesel generator were in the range 3–356 h/year with renewable energy fractions in the range 0.89–1.00. However, only 22 PVHS had two parallel battery strings as stipulated in the request for proposal launched by MTN Cameroon in 2008. The PV array sizes evaluated for the 22 PVHS were found to be the range 2.4–10.8 kWp corresponding to daily energy demands in the range 7.31–31.79 kW h/d. The energy costs and breakeven grid distances determined were in the ranges 0.81–1.32 €/kW h and 10.75–32.00 km respectively.  相似文献   

11.
《Applied Thermal Engineering》2007,27(2-3):576-585
A household size trigeneration based on a small-scale diesel engine generator set is designed and realized in laboratory. Experimental tests are carried out to evaluate the performance and emissions of the original single generation (diesel engine generator); and the performances of the whole trigeneration including the diesel generator within the trigeneration system, the heat exchangers which are used to recover heat from engine exhaust, the absorption refrigerator which is driven by the exhaust heat; and the emissions from the whole trigeneration.Comparisons of the test results of two generations are also performed. The test results show that the total thermal efficiency of trigeneration reaches to 67.3% at the engine full load, comparing to that of the original single generation 22.1% only. Within the range of engine loads tested, the total thermal efficiencies of trigeneration are from 205% to 438% higher than that of the thermal efficiency of single generation.The CO2 emission per unit (kW h) of useful energy output from trigeneration is 0.401 kg CO2/kW h at the engine full load, compared to that of 1.22 kg CO2/kW h from single generation at the same engine load. Within the range of engine loads tested, the reductions of CO2 emission per unit (kW h) of trigeneration output are from 67.2% to 81.4% compared to those of single generation.The experimental results show that the idea of realizing a household size trigeneration is feasible; the design and the set-up of the trigeneration is successful. The experimental results show that the innovative small-scale trigeneration is able to generate electricity, produce heat and drive a refrigeration system, simultaneously from a single fuel (diesel) input.  相似文献   

12.
The study was conducted to determine the consequences of a carbon tax, equal to an estimated social cost of carbon of $37.2/Mg, on household electricity cost, and to determine if a carbon tax would be sufficient to incentivize households to install either a grid-tied solar or wind system. U.S. Department of Energy hourly residential profiles for five locations, 20 years of hourly weather data, prevailing electricity pricing rate schedules, and purchase prices and solar panel and wind turbine power output response functions, were used to address the objectives. Two commercially available household solar panels (4 kW, 12 kW), two wind turbines (6 kW, 12 kW), and two price rate structures (traditional meter, smart meter) were considered. Averaged across the five households, the carbon tax is expected to reduce annual consumption by 4.4% (552 kWh/year) for traditional meter households and by 4.9% (611 kWh/year) for households charged smart meter rates. The carbon tax increases electricity cost by 19% ($202/year). For a household cost of $202/year the carbon tax is expected to reduce social costs by $11. Annual carbon tax collections of $234/household are expected. Adding the carbon tax was found to be insufficient to incentivize households to install either a solar panel or wind turbine system. Installation of a 4 kW solar system would increase the annual cost by $1546 (247%) and decrease CO2 emissions by 38% (2526 kg) valued at $94/household. The consequence of a carbon tax would depend largely on how the proceeds of the tax are used.  相似文献   

13.
The advantage of PV–thermal hybrid systems is their high total efficiency. By using concentrating hybrid systems, the cost per energy produced is reduced due to simultaneous heat and electricity production and a reduced PV cell area. In this article, the optical efficiency of a water-cooled PV–thermal hybrid system with low concentrating aluminium compound parabolic concentrators is discussed. The system was built in 1999 in Älvkarleby, Sweden (60.5° N, 17.4° E) with a geometric concentration ratio of C=4 and 0.5 kWp electric power. The yearly output is 250 kWh of electricity per square metre solar cell area and 800 kWh of heat at low temperatures per square metre solar cell area. By using numerical data from optical measurements of the components (glazing, reflectors, and PV cells) the optical efficiency, ηopt, of the PV–CPC system has been determined to be 0.71, which is in agreement with the optical efficiency as determined from thermal and electrical measurements. Calculations show that optimised antireflection-treated glazing and reflectors could further increase the electric power yield.  相似文献   

14.
《Biomass & bioenergy》2006,30(1):28-37
A partial equilibrium model with a break-even price approach was used to create supply curves for the energy crop reed canary grass (Phalaris arundinacea L.) (RCG) in Västerbotten County in northern Sweden. The impact of the European Union's (EU) Common Agricultural Policy (CAP) on the supply curves was studied by comparison of three different scenarios. Supply curves were created including agricultural subsidies under the current subsidy scheme, the Commission's proposal for a new subsidy scheme for implementation in 2004, and without subsidies. The geographical distribution of the potential supply was determined by the use of GIS tools. Under the current subsidy scheme, the lowest RCG farmgate fuel price would be 56 SEK MWh−1. A RCG production equalling 360 GWh could be available at that fuel price level. Under the proposed subsidy scheme of 2004, a farmgate fuel price of 99 SEK MWh−1 is required for RCG production amounting to 910 GWh. In the scenario where no subsidies are disbursed, the lowest break-even price would be 115 SEK MWh−1. In all scenarios, a biofuel feedstock production from RCG equivalent to 1.3 TWh could be available at a farmgate fuel price of 116 SEK MWh−1. The RCG supply would be concentrated in the coastal area of the county, which has the most developed infrastructure and the highest population density, thus providing a nearby market for the fuel.  相似文献   

15.
Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 €/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 €/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 €/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation.  相似文献   

16.
The work presented in this article aims to investigate a PV/T hybrid solar window on a system level. A PV/T hybrid is an absorber on which solar cells have been laminated. The solar window is a PV/T hybrid collector with tiltable insulated reflectors integrated into a window. It simultaneously replaces thermal collectors, PV-modules and sunshade. The building integration lowers the total price of the construction since the collector utilizes the frame and the glazing in the window. When it is placed in the window a complex interaction takes place. On the positive side is the reduction of the thermal losses due to the insulated reflectors. On the negative side is the blocking of solar radiation that would otherwise heat the building passively. This limits the performance of the solar window since a photon can only be used once. To investigate the sum of such complex interaction a system analysis has to be performed. In this paper results are presented from such a system analysis showing both benefits and problems with the product. The building system with individual solar energy components, i.e. solar collector and PV modules, of the same size as the solar window, uses 1100 kW h less auxiliary energy than the system with a solar window. However, the solar window system uses 600 kW h less auxiliary energy than a system with no solar collector.  相似文献   

17.
This paper presents the pico-hydro development status in Lao PDR and introduces the Pump as Turbine (PAT) concept as an alternative for isolated communities (40–500 people). The intention is to provide a long-term reproducible system for communities where pico-hydro propeller turbines are insufficient and proper turbines are expensive. This approach presents a high quality and cost-effective solution for rural electrification which can be installed, commissioned, and maintained by local staff and villagers. Furthermore, a 2 kWel PAT-scheme is proposed for a community in the Xiagnabouli province and considers power generation alternatives, sizing, asynchronous motor simulation, civil works, cost estimation, and social aspects.  相似文献   

18.
We applied conditional demand analysis (CDA) to estimate the average annual energy use of various electrical and natural gas appliances, and derived energy reductions associated with certain appliance upgrades and behaviours. The raw data came from 9773 Canadian households, and comprised annual electricity and natural gas use, and responses to >600 questions on dwelling and occupant characteristics, appliances, heating and cooling equipment, and associated behaviours. Replacing an old (>10 years) refrigerator with a new one was estimated to save 100 kW h/year; replacing an incandescent lamp with a CFL/LED lamp was estimated to save 20 kW h/year; and upgrading an old central heating system with a new one was estimated to save 2000 kW h/year. This latter effect was similar to that of reducing the number of walls exposed to the outside. Reducing the winter thermostat setpoint during occupied, waking hours was estimated to lower annual energy use by 200 kW h/°C-reduction, and lowering the thermostat setting overnight in winter relative to the setting during waking hours (night-time setback) was estimated to have a similar effect. This information may be used by policy-makers to optimize incentive programs, information campaigns, or other energy use change instruments.  相似文献   

19.
《Journal of power sources》2001,96(1):233-235
The use of metal based bipolar plates in polymer electrolyte membrane (PEM) fuel cells, with an active coating on titanium to reduce voltage losses due to the formation of passive layers has been demonstrated. Lifetime data in excess of 8000 h has been achieved and power densities in excess of 1.8 kW dm−3 and 1 kW kg−1 are predicted.  相似文献   

20.
This paper presents experimentally determined heat transfer coefficients for condensation from a superheated vapor of CO2 and R410A. The superheated vapor was flowed through a smooth horizontal tube with 6.1 mm ID under almost uniform temperature cooling at reduced pressures from 0.55 to 0.95, heat fluxes from 3 to 20 kW m?2, and superheats from 0 to 40 K. When the tube wall temperature reaches the saturation point, the measured results show that the heat transfer coefficient gradually starts deviating from the values predicted by a correlation valid for single-phase gas cooling. This point identifies the start of condensation from the superheated vapor. The condensation starts earlier at higher heat fluxes because the tube wall temperature reaches the saturation point earlier. The heat transfer coefficient reaches a value predicted by correlations for condensation at a thermodynamic vapor quality of 1. The measured heat transfer coefficient of CO2 is roughly 20–70% higher than that of R410A at the same reduced pressures. This is mainly because the larger latent heat and liquid thermal conductivity of CO2, compared to that of R410A, increase the heat transfer coefficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号