首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-speed rotational atherectomy was performed followed by adjunct directional atherectomy in 10 patients with symptomatic coronary artery disease and calcified target lesions and the results were evaluated using quantitative coronary arteriography and intravascular ultrasound. Target lesion calcium is common in obstructive coronary artery disease. High-speed rotational coronary atherectomy preferentially abrades noncompliant atherosclerotic plaque material, especially calcium, but often requires adjunct balloon angioplasty to achieve optimal lumen dimensions. Directional coronary atherectomy has limited efficacy in heavily calcified plaque; usually, it is a definitive primary procedure in large arteries with noncalcified target lesions. Neither of these devices alone is effective in treating calcified target lesions in large coronary arteries. Before intervention, after rotational and adjunct directional atherectomy, these measurements were obtained: quantitative coronary arteriographic measurements of minimal lumen diameter and percent diameter stenosis and intravascular ultrasound measurements of external elastic membrane, lumen, and plaque+media cross-sectional areas; percent cross-sectional narrowing; minimal lumen diameter; and target-lesion arc of calcium. With use of quantitative coronary arteriography, the preintervention minimal lumen diameter measured 0.7 +/- 0.4 mm, increased to 1.5 +/- 0.5 mm after rotational atherectomy (p = 0.0013) and to 2.5 +/- 0.3 mm after adjunct directional atherectomy (p < 0.001). The preintervention percent diameter stenosis measured 78 +/- 15%, decreased to 50 +/- 17% after rotational atherectomy (p = 0.0011), and to 17 +/- 11% (p < 0.001) after adjunct directional coronary atherectomy.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
OBJECTIVES: The purpose of this study was to assess the dual action of lumen enlargement and vessel wall damage following either balloon angioplasty or directional atherectomy, using intracoronary ultrasound, and angioscopy. BACKGROUND: Differences in the mechanisms of action of balloon angioplasty and directional atherectomy may have a significant bearing on the immediate outcome and the restenosis rate at 6 months. METHODS: A total of 36 patients were studied before and after either balloon angioplasty (n = 18) or directional atherectomy (n = 18). Ultrasound measurements included changes in lumen area, external elastic membrane area and plaque burden. In addition, the presence and extent of dissections were assessed to derive a damage score. Angioscopic assessment of the dilated or atherectomized stenotic lesions was translated into semi-quantitative dissection, thrombus and haemorrhage scores. RESULTS: Atherectomy patients had a larger angiographic vessel size compared with the angioplasty group (3.55 +/- 0.46 mm vs 3.00 +/- 0.64 mm, P < 0.05); however, minimal lumen diameter (1.18 +/- 0.96 mm vs 0.85 +/- 0.49 mm) and plaque burden (17.04 +/- 3.69 vs 15.23 +/- 4.92 mm2) measurements did not differ significantly. As a result of plaque reduction, atherectomy produced a larger increase in luminal area than the angioplasty group (5.80 +/- 1.78 mm2 vs 2.44 +/- 1.36 mm2, P < 0.0001). Lumen increase after angioplasty was the result of 'plaque compression' (50%) and wall stretching (50%). Additionally, in both groups there was indirect angioscopic evidence of thrombus 'microembolization' as an adjunctive mechanism of lumen enlargement. Angioscopy identified big flaps in six and small intimal flaps in 11 of the atherectomized patients as compared with five and 12 patients in the angioplasty group. Changes in thrombus score following both coronary interventions were identical (0.72 +/- 3.42 points atherectomy vs -0.38 +/- 3.27 points balloon angioplasty, ns). CONCLUSIONS: Lumen enlargement after directional atherectomy is mainly achieved by plaque removal (87%), whereas balloon dilation is the result of vessel wall stretching (50%) and plaque reduction (50%). Despite the fact that the luminal gain achieved by directional atherectomy is twice that achieved with balloon angioplasty, the extent of trauma induced by both techniques seems to be similar.  相似文献   

3.
OBJECTIVES: The purpose of this study was to compare the immediate angiographic and long-term results of debulking versus balloon angioplasty for treatment of true bifurcation lesions. BACKGROUND: Previous studies have shown true bifurcation lesions to be a high risk morphological subset for percutaneous transluminal coronary angioplasty (PTCA). Although atherectomy devices have been used to treat bifurcation lesions, no studies have compared the outcomes of these alternative treatment modalities. METHODS: Between January 1992 and May 1997, we treated 70 consecutive patients with true bifurcation lesions (defined as a greater than 50% stenosis in both the parent vessel and contiguous side branch) with conventional PTCA (n = 30) or debulking (with rotational or directional atherectomy) plus adjunctive PTCA (n = 40). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained in all patients. RESULTS: Acute procedural success was 73% in the PTCA group and 97% in the debulking group (p = 0.01). Major in-hospital complications occurred in two patients in the PTCA group and one in the debulking group. Treatment with atherectomy plus PTCA resulted in lower postprocedure residual stenoses than PTCA alone (16+/-15% vs. 33+/-17% in the parent vessel, and 6+/-15% vs. 39+/-22% in the side branch; p < 0.001 for both comparisons). At 1 year follow-up, the incidence of target vessel revascularization (TVR) was 53% in the PTCA group as compared with 28% in the debulking group (p = 0.05). Independent predictors of the need for repeat TVR were side branch diameter >2.3 mm, longer lesion lengths, and treatment with PTCA alone. CONCLUSIONS: For the treatment of true bifurcation lesions, atherectomy with adjunctive PTCA is safe, improves acute angiographic results, and decreases target vessel revascularization compared to PTCA alone. The benefits of debulking for bifurcation lesions were especially seen in lesions involving large side branches.  相似文献   

4.
The effect of domestically-manufactured excimer laser with adjunctive balloon angioplasty in achieving revascularization and reduction of residual stenosis was assessed. 20 femoral arteries with thrombosis and occlusion from 12 dogs were subject to angiography. At first excimer laser angioplasty was done followed by balloon angioplasty. The diameter and residual stenosis of revascularized vessel were measured. The result showed that 17 out of 20 vessels (85%) were revascularized. The diameter of revascularized vessel by excimer laser were 1.22 +/- 0.14 mm, while residual stenoses were 54% +/- 5%. After adjunctive balloon angioplasty the diameter and residual stenoses were 2.04 +/- 0.16 mm and 20% +/- 7% respectively (P < 0.05 and P < 0.01). Complication in form of vasoperforation occurred in 3/20 vessels (15%). It is concluded that China- manufactured excimer laser angioplasty is effective when used for revascularization. While the reduction of narrowing and residual stenoses was enhanced after adjunction of balloon angioplasty. This method can be employed in treating peripheral occlusive disease effectively and safely.  相似文献   

5.
The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in 23 lesions in 21 patients. Indications for stent implantation were acute closure in 1, threatened closure in 15, and electively in 7 lesions. In 2 cases, the lesion involved a bifurcation where a stent was implanted in both vessels. All patients received aspirin and ticlopidine. No anticoagulant therapy was given. The stenting procedure was successful in 22 of 23 lesions. No complications occurred with the exception of 1 patient with a thrombotic reocclusion within 1 hr after stent implantation and 1 patient with a temporary occlusion of a side branch. The mean minimal luminal diameter (MLD) increased from 0.74+/-0.46 mm before balloon dilatation to 1.27+/-0.62 mm before stent implantation and 2.32+/-0.57 mm after stent implantation. Percent stenosis decreased from 71+/-19% before angioplasty to 46+/-25% after angioplasty to 5+/-8% after stent implantation. MLD at the time of follow-up angiography after 4 months was 1.98+/-0.77 mm and percent stenosis was 26+/-21%. Restenosis of more than 50% occurred in 2 lesions. In these lesions, a second percutaneous transluminal coronary angioplasty was performed. Advantages of this stent are its flexibility together with an acceptable radial strength as well as enabling radiopacity without obscuring the arterial lumen. Stenting of bifurcation lesions is possible.  相似文献   

6.
In vivo endovascular ultrasonography has confirmed the extension of atheroma to angiographically normal segments. The authors set out to determine by endocoronary ultrasonography if the introduction of the atherotome changed the intimal thickness 20 mm proximal and distal to the site treated. The area circumscribed by the external elastic layer (EEL) and the surface area of the lumen was measured in 17 patients: 1) before atherectomy; 2) after atherectomy; 3) at control 6 months later. Atherectomy immediately increased the luminal area at the site dilated from 1.9 + 0.9 to 8.1 +/- 2mm (p < 0.001). At the proximal segment, the surface area of the lumen was unchanged (mean + 0.6 +/- 1.5 mm2; p = 0.13). Similarly the procedure did not change the surface circumscribed by the EEL (mean + 0.8 +/- 3.2 mm2; p = 0.32) in this zone. The same results were observed at the distal site. At 6 months, the areas under the EEL and those of the lumen were unchanged at the unoperated sites. The mean of the differences (+/- 1 SD) for the area under the EEL was respectively -0.2 +/- 1.5 mm2 proximally and +0.7 +/- 2.5 mm2 distally. The means for the luminal area were 0.2 +/- 1 mm2 proximally and -0.01 +/- 1.1 mm2; distally. At the site of atherectomy, the luminal surface increased (+2.0 +/- 2.6 mm2; p < 0.01) as did the area under the EEL (+2.0 +/- 3.5 mm2; p < 0.05). This preliminary series shows no significant progression of atherosclerosis at the sites not affected by atherectomy.  相似文献   

7.
Patients with recurrent angina after coronary artery bypass graft surgery pose a problem. Stent implantation has been advocated in an effort to avoid repeat operation and to address the limitations of balloon angioplasty. Aim of the present study was to determine the in-hospital and long-term results of stent deployment in focal, de novo lesions of vein grafts. Thirty-five focal, de novo lesions of vein grafts in 31 patients were treated with stent deployment. Twenty-four patients (77%) had three vessels, 6 (20%) two vessels and 1 (3%) single vessel disease. Saphenous vein grafts aged 9.7 +/- 4.2 years (range 1-19 years). Twenty-two lesions (63%) were located within the body of the saphenous graft, 8 (23%) at the graft/coronary artery anastomosis and 5 (14%) at the aorta/graft anastomosis. The indications for stent deployment included: suboptimal result from balloon angioplasty (defined as > or = 50% post-angioplasty residual stenosis) in 29/35 lesions (83%); post-angioplasty coronary dissection with threatening occlusion in 4/35 (11%); abrupt closure in 2/35 (6%). Patients were screened for death, myocardial infarction, bypass surgery and repeat angioplasty during in-hospital stay and after a follow-up of 12 +/- 8 months. Even-free survival curve was constructed by the Kaplan-Meier method. Stent deployment was successful in all patients. One stent was deployed in 24/35 lesions (69%), half Palmaz-Schatz stent in 6/35 (17%) and 2 or more stents in 5/35 (14%). The balloon/vessel ratio resulted of 1.0 +/- 0.1 Minimal lumen diameter increased from 0.8 +/- 0.4 to 3.8 +/- 0.6 mm, with a mean gain of 1.8 +/- 0.6 mm (range 1.8-4.0 mm). During the in-hospital period 1 patient (3.2%) died and 1 (3.2%) had a non Q wave myocardial infarction. Therefore, the clinical success rate, was 94%. During the follow-up period, 2 patients died (6.9%), 2 (6.9%) developed a non Q wave myocardial infarction, 1 (3.4%) underwent bypass surgery and 3 (10.3%) underwent repeat angioplasty. The estimated 2-year event-free survival rate (free from myocardial infarction, repeat surgery and repeat angioplasty) was 62%. In conclusion, Palmaz-Schatz stent deployment in focal, de novo vein grafts presents a high rate of procedural success, a low rate of acute complications and good long-term results.  相似文献   

8.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

9.
OBJECTIVES: We assessed the safety and efficacy of stent placement in patients with poorly controlled hypertension and renal artery stenoses, which are difficult to treat with balloon angioplasty alone. BACKGROUND: Preliminary experience with stent placement suggests improved results over balloon angioplasty alone in patients with atherosclerotic renal artery stenosis. METHODS: Balloon-expandable stents were placed in 100 consecutive patients (133 renal arteries) with hypertension and renal artery stenosis. Sixty-seven of the patients had unilateral renal artery stenosis treated and 33 had bilateral renal artery stenoses treated with stents placed in both renal arteries. RESULTS: Angiographic success, as determined by quantitative angiography, was obtained in 132 (99%) of 133 lesions. Early clinical success was achieved in 76% of the patients. Six months after stent placement, the systolic blood pressure was reduced from 173 +/- 25 to 147 +/- 23 mm Hg (p < 0.001); the diastolic pressure from 88 +/- 17 to 76 +/- 12 mm Hg (p < 0.001); and the mean number of antihypertensive medications per patient from 2.6 +/- 1 to 2.0 +/- 0.9 (p < 0.001). Angiographic follow-up at a mean of 8.7 +/- 5.0 months in 67 patients revealed restenosis (>50% diameter narrowing) in 15 (19%) of 80 stented vessels. CONCLUSIONS: Renal artery stenting is an effective treatment for renovascular hypertension, with a low angiographic restenosis rate. Stent placement appears to be a very attractive therapy in patients with lesions difficult to treat with balloon angioplasty such as renal aorto-ostial lesions and restenotic lesions, as well as after a suboptimal balloon angioplasty result.  相似文献   

10.
Arterial bypass grafting for occlusive disease is still considered the gold standard in the treatment of arterial occlusive disease. However, less invasive methods are available for select patients. Percutaneous balloon angioplasty has been shown to be effective in focal iliac artery stenosis, with patency rates of 50% to 90% at 5 years. Patency rates for femoropopliteal lesions are generally less than 50% at 2 years. Complications seen with balloon angioplasty often can be treated with arterial stents. Stents can be categorized into balloon-expandable, which provide a rigid scaffold to support the artery, self-expanding, which exert radial force to resist external compression, and thermal expanding stents, which allow for the use of a smaller introducer sheath. Another treatment option is atherectomy, in which the offending lesion is removed instead of fracturing and dilating the lumen. Although overall initial results of atherectomy have not been favorable, short lesions with eccentric atheroma or intimal hyperplasia, such as those seen in dialysis access fistulas or vein graft stenoses, may respond well.  相似文献   

11.
One hundred twenty-three patients treated with high-speed rotational atherectomy (HSRA) were restudied 6.9 +/- 1.2 months later. At the follow-up, the number of focal concentric lesions increased from 32.2 percent to 63.0 percent, p<0.01, with decrease of type C lesions from 54.8 percent to 30.8 percent, p<0.05. Comparison of the degree of the net gain (NG) showed more severe baseline lesions in the high-gain group (NG >20 percent) compared with the moderate-gain group (20 percent > NG > 0 percent) and to the loss group (minimal luminal diameter [MLD] 0.8 +/- 0.4 mm vs 1.0 +/ 0.4 mm, p<0.05; and 1.2 +/- 0.5 mm; p<0.01, respectively). Highest initial gain (36.5 percent +/- 26.2 percent vs 24.5 percent +/- 18.1 percent; p<0.015; and 19.0 percent +/- 23.2 percent; p<0.001) as well as lowest late loss (1.8 percent +/- 21.7 percent vs 14.0 percent +/-18.4 percent; p<0.01 and 28.1 percent +/- 25.0 percent; p<0.01) were found in the high NG group. A higher interaction between burr and atheroma resulted in the lowest restenosis rate of 6 percent.  相似文献   

12.
We evaluated acute and long-term clinical and angiographic results of elective Palmaz-Schatz coronary stent implantation for left anterior descending coronary artery (LAD) ostial stenosis in 23 consecutive patients. Eight patients had stable angina, 14 had unstable angina, and 1 had recent myocardial infarction. Sixteen patients had single-vessel, 5 had double-vessel, and 2 had triple-vessel disease. Clinical success without major complications (death, acute myocardial infarction, emergency coronary artery bypass grafting) was obtained in all cases and technical success in 20 cases (86.9%). After stenting, minimal lumen diameter increased from 1.05 +/- 0.45 mm to 2.89 +/- 0.52 mm (p < 0.001), and percent diameter stenosis decreased from 65.49% +/- 13.36% to 2.94% +/- 19.93% (p < 0.001). One case of subacute thrombosis and no major bleeding occurred. Twenty patients were followed-up for 6 months, during which no acute cardiac event (death, acute myocardial infarction) was observed. Eighteen patients were eligible for follow-up coronary angiography; restenosis (> or = 50% diameter stenosis) was observed in 4 (22.2%). Minimal lumen diameter was 1.77 +/- 0.55 mm, percent diameter stenosis was 39.66% +/- 17.62%, late loss was 1.01 +/- 0.69 mm, net gain was 0.79 +/- 0.55 mm, and loss index (late loss/acute gain) was 0.53 +/- 0.37. This study suggests that elective Palmaz-Schatz stent implantation may be a safe and successful treatment of LAD ostial lesions and provides a large increase in lumen diameter.  相似文献   

13.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

14.
OBJECTIVES: This study was designed to examine whether oversized implantation of the new, less shortening Wallstent provides a more favorable long-term clinical and angiographic outcome in chronic total occlusions than does conventional coronary balloon angioplasty. BACKGROUND: Restenosis and reocclusion remain major limitations of balloon angioplasty for chronic total occlusions. Enforced mechanical remodeling by implantation of the oversized Wallstent may prevent elastic recoil and improve accommodation of intimal hyperplasia. METHODS: Lumen dimension was measured by a computer-based quantitative coronary angiography system (CAAS II). These measurements (before and after intervention and at 6-month follow-up) were compared between the groups with Wallstent implantation (20 lesions, 20 patients) and conventional balloon angioplasty (266 lesions, 249 patients) for treatment of chronic total occlusion. Acute gain (minimal lumen diameter after intervention minus that before intervention), late loss (minimal lumen diameter after intervention minus that at follow-up) and net gain (acute gain minus late loss) were examined. RESULTS: Wallstent deployment was successful in all patients. High pressure intra-Wallstent balloon inflation (mean +/- SD 14 +/- 3 atm) was performed in all lesions. Although vessel size did not differ between the Wallstent and balloon angioplasty groups, acute gain was significantly greater in the Wallstent group (2.96 +/- 0.55 vs. 1.61 +/- 0.34 mm, p < 0.0001). Although late loss was also significantly larger in the Wallstent group (0.81 +/- 0.95 vs. 0.43 +/- 0.68 mm, p < 0.05), net gain was still significantly greater in this group (2.27 +/- 1.00 vs. 1.18 +/- 0.69 mm, p < 0.0001). Angiographic restenosis (> or = 50% diameter stenosis) occurred at 6 months in 29% of lesions in the Wallstent group and in 45% of those in the balloon angioplasty group (p = 0.5150). CONCLUSIONS: Implantation of the oversized Wallstent, with full coverage of the lesion length, ensures resetting of the vessel size to its original caliber before disease and allows greater accommodation of intimal hyperplasia and chronic vessel recoil. Wallstent implantation provides a more favorable short- and long-term clinical and angiographic outcome than does conventional balloon angioplasty for chronic total occlusions.  相似文献   

15.
BACKGROUND: Restenosis remains the major limitation of coronary angioplasty. Coronary stents have reduced the incidence of restenosis in selected patients with relatively large vessels. No strategies to date have demonstrated a beneficial effect in vessels < 3.0 mm in diameter. We have shown in the MultiVitamins and Probucol (MVP) Trial that probucol, a potent antioxidant, reduces restenosis after balloon angioplasty. The purpose of this study was to determine whether the benefit of probucol therapy is maintained in the subgroup of patients with smaller coronary vessels. METHODS AND RESULTS: We studied a subgroup of 189 patients included in the MVP trial who underwent successful balloon angioplasty of at least one coronary segment with a reference diameter < 3.0 mm. One month before angioplasty, patients were randomly assigned to one of four treatments: placebo, probucol (500 mg), multivitamins (beta-carotene 30000 IU, vitamin C 500 mg, and vitamin E 700 IU), or probucol plus multivitamins twice daily. The treatment was maintained until follow-up angiography was performed at 6 months. The mean reference diameter of this study population was 2.49+/-0.34 mm. Lumen loss was 0.12+/-0.34 mm for probucol, 0.25+/-0.43 mm for the combined treatment, 0.35+/-0.56 mm for vitamins, and 0.38+/-0.51 mm for placebo (P=.005 for probucol). Restenosis rates per segment were 20.0% for probucol, 28.6% for the combined treatment, 45.1% for vitamins, and 37.3% for placebo (P=.006 for probucol). CONCLUSIONS: Probucol reduces lumen loss and restenosis rate after balloon angioplasty in small coronary arteries.  相似文献   

16.
BACKGROUND AND OBJECTIVE: The solid-state, mid-infrared holmium:YAG laser (2.1 microm wavelength) is a relatively new percutaneous device that has recently been evaluated in a multicenter study. Because of its unique wavelength and photoacoustic effects on atherosclerotic plaques, this laser may be useful in treatment of symptomatic patients with coronary artery disease. This study sought to evaluate the safety and efficacy of mid-infrared laser angioplasty in the treatment of coronary artery lesions. PATIENTS AND METHODS: Laser angioplasty was performed on 2,038 atherosclerotic lesions in 1,862 consecutive patients with a mean age of 61 +/- 11 years. Clinical indications included unstable angina (69%), stable angina (20%), acute infarction (6%), and positive exercise test (5%). Complex lesion morphology included eccentricity (62%), thrombus (30%), total occlusion (27%), long lesions (14%), and saphenous vein grafts (11%). RESULTS: This laser catheter alone successfully reduced stenosis (>20%) in 87% of lesions. With adjunct balloon angioplasty, 93% procedural success was achieved. The presence of thrombus within the target lesion was a predictor of procedural success (OR = 2.0 [95% confidence interval 2.0, 4.0], P = .04). Bifurcation lesions (OR = 0.5 [95% confidence interval 0.2, 1.0], P = .05) and severe tortuosity of the treated vessel (OR = 0.4 [95% confidence interval 0.2, 0.9], P = .02) were identified as significant predictors of decreased laser success. Calcium within the lesion was associated with reduced procedural success (OR = 0.57 [95% confidence interval 0.34, 0.97], P = .03), and calcified lesions required significantly more energy pulses than noncalcified lesions (119 +/- 91 pulses vs. 101 +/- 86 pulses, respectively, P = .0002). Complications included in-hospital bypass surgery 2.5%, Q-wave myocardial infarction 1.2%, and death 0.8%. Perforation occurred in 2.2% of patients; major dissection in 5.8% of patients, and spasm in 12% of patients. No predictor of major complications was identified. Six-month angiographic restenosis was documented in 54% of patients, and clinical restenosis occurred in 34% of patients. CONCLUSION: Mid-infrared laser has a safety profile similar to that of other debulking devices. This laser may be useful in select patients presenting with acute ischemic syndromes associated with intracoronary thrombus; however, like other coronary lasers, it is limited by the need for adjunctive balloon angioplasty and/or stenting to achieve adequate final luminal diameter. No beneficial effects on reducing 6-month restenosis rates were observed.  相似文献   

17.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

18.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

19.
Registries of excimer laser coronary angioplasty have reported good results in the treatment of complex coronary artery disease, including total or subtotal coronary occlusions. One hundred three patients (103 lesions) with a functional or total coronary occlusion were included in a randomized trial (Amsterdam-Rotterdam [AMRO] trial, total of 308 patients), 49 patients were allocated to laser angioplasty and 54 patients to balloon angioplasty. The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomized segment during a 6-month follow-up period. The primary angiographic end point was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by an automated contour-detection algorithm. Laser angioplasty was followed by balloon angioplasty in all procedures. The angiographic success rate was 65% in patients treated with excimer laser-assisted balloon angioplasty compared with 61% in patients treated with balloon angioplasty alone. No deaths occurred. There were no significant differences between the laser angioplasty group and the balloon angioplasty group in the incidence of myocardial infarctions (1 patient vs 3, respectively, p = 0.36), coronary bypass surgery (4 patients vs 2, respectively, p = 0.34), repeat angioplasty (10 patients vs 8, respectively, p = 0.46) or primary clinical end point (15 patients vs 12, respectively, p = 0.34). The net gain in minimal lumen diameter and restenosis rate (>50% diameter stenosis at follow-up) were 0.81 +/- 0.74 mm and 66.7%, respectively, in patients treated with laser angioplasty compared with 1.04 +/- 0.68 mm and 48.5%, respectively, in patients treated with balloon angioplasty (p = 0.59 and p = 0.15, respectively). Excimer laser-assisted balloon angioplasty demonstrated no benefit over balloon angioplasty with respect to initial and long-term clinical and angiographic outcome in the treatment of patients with functional or total coronary occlusions of >10 mm in length.  相似文献   

20.
Intravascular ultrasound (IVUS) imaging was used to measure internal luminal area immediately after percutaneous transluminal coronary angioplasty (PTCA) in 83 patients (59 males, 24 females, mean age 63 +/- 12 years) with angina pectoris to determine the need for additional intervention. The effectiveness of these interventions to prevent restenosis was also studied. Thirty-five patients (42%) with insufficient dilatation revealed an internal luminal area less than 5 mm2 or luminal stenosis greater than 60% as evaluated by IVUS imaging following the procedure. The luminal area increased from 4.5 +/- 1.1 to 7.9 +/- 2.8 mm2 and the percentage luminal stenosis improved from 66 +/- 9% to 54 +/- 9% in patients who underwent further dilatation with a larger size balloon, longer dilatation time, directional coronary atherectomy, or stenting. The insufficient dilatation group exhibited hard plaque and calcification more frequently than in the other group (48 patients, 58%) in whom sufficient dilatation of the target lesion was achieved. The incidence of restenosis in the sufficient dilatation group was 25%, compared to 33% of the patients receiving additional treatment after IVUS imaging and 42% in the 192 patients who underwent PTCA without IVUS imaging. IVUS imaging is a useful method for evaluation of complex luminal morphology to decrease the incidence of restenosis and for determination of the end point and the extent of dilatation required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号