首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到9条相似文献,搜索用时 0 毫秒
1.
综述了超临界萃取作为样品技术在痕量药检分析中的应用。研究了生物基质对有效萃取目标检测物的影响及提高萃取率的途径。并重点评述了减少类脂杂质、选择性的分离目标检测物的非在线吸附剂收集与在线吸附收集技术。从而展示了SFE作为绿色化学技术具有萃取率高、使用溶剂少,分离步骤少,环境无害等明显优于传统方法的特点。  相似文献   

2.
《分离科学与技术》2012,47(5):765-773
Membrane based non-dispersive solvent extraction (NDSX) of Nd(III) from aqueous nitric acid medium was carried out using a commercial liquid-liquid extraction system consisting of an extra-flow hollow fiber module with about 10,000 microporous hydrophobic polypropylene capillaries with an effective surface area of 1.4 m2. The NDSX operation was carried out by pumping about 1 g/L Nd(III) solutions at a fixed nitric acid concentration of 3.57 M through the tube side and organic solvent (tetra-n-octyl-3-oxapentane-diamide (TODGA) in normal paraffin hydrocarbon (NPH)) through the shell side of the hollow fiber capillaries. NDSX studies were performed under different hydrodynamic conditions and the overall mass transfer was evaluated under counter-current flow conditions. Conditions for quantitative extraction and stripping were also identified. Reproducibility of the results from multiple runs was found to be excellent after five different identical runs.  相似文献   

3.
Abstract

The extraction of Au(III) by the chloride salt of the amine Alamine 304 (R3NH+Cl?) in xylene from hydrochloric acid solutions has been investigated. The analysis of metal distribution data by numerical calculations suggested the formation of the species R3NH+AuCl4 ? in the organic phase with formation constant log K ext = 5.44. The results obtained on Au(III) distribution have been implemented in a solid‐supported liquid membrane system, where in NaSCN solutions were found to be the most effective to strip the metal from the organic solution. Influence of membrane composition, metal concentration on gold transport, and the selectivity of the system have also been studied.  相似文献   

4.
Laccases are multi-copper oxidases that catalyze the oxidation of various electron-rich substrates with concomitant reduction of molecular oxygen to water. The multi-copper oxidase/laccase CueO of Escherichia coli is responsible for the oxidation of Cu+ to the less harmful Cu2+ in the periplasm. CueO has a relatively broad substrate spectrum as laccase, and its activity is enhanced by copper excess. The aim of this study was to trigger CueO activity in vivo for the use in biocatalysis. The addition of 5 mM CuSO4 was proven effective in triggering CueO activity at need with minor toxic effects on E. coli cells. Cu-treated E. coli cells were able to convert several phenolic compounds to the corresponding dimers. Finally, the endogenous CueO activity was applied to a four-step cascade, in which coniferyl alcohol was converted to the valuable plant lignan (−)-matairesinol.  相似文献   

5.
褐藻糖胶的萃取和反萃   总被引:5,自引:1,他引:4  
研究了无机盐种类和浓度对N263萃取褐藻糖胶的影响. 结果表明,无机盐浓度是影响褐藻糖胶萃取的最主要因素, 褐藻糖胶的萃取率随盐浓度的增加而迅速降低,在无机盐存在下,增加萃取剂浓度并不能增加对褐藻糖胶的萃取. 用盐水溶液反萃不同条件下萃取的褐藻糖胶,结果表明,反萃率随盐浓度的增加而增加,在相同的氯离子浓度下,钠盐的反萃效率优于钙盐,随有机相中褐藻糖胶浓度的增加, 盐的反萃效率降低. 比较了不同溶剂作为稀释剂对用盐溶液反萃褐藻糖胶的影响,表明CCl4作为稀释剂时盐的反萃效率最低.  相似文献   

6.
Oxygen, as an external environmental factor, plays a role in the early differentiation of human stem cells, such as induced pluripotent stem cells (hiPSCs). However, the effect of oxygen concentration on the early-stage differentiation of hiPSC is not fully understood, especially in 3D aggregate cultures. In this study, we cultivated the 3D aggregation of hiPSCs on oxygen-permeable microwells under different oxygen concentrations ranging from 2.5 to 20% and found that the aggregates became larger, corresponding to the increase in oxygen level. In a low oxygen environment, the glycolytic pathway was more profound, and the differentiation markers of the three germ layers were upregulated, suggesting that the oxygen concentration can function as a regulator of differentiation during the early stage of development. In conclusion, culturing stem cells on oxygen-permeable microwells may serve as a platform to investigate the effect of oxygen concentration on diverse cell fate decisions during development.  相似文献   

7.
Background. Today there are many devices that can be used to study blood clotting disorders by identifying abnormalities in blood platelets. The Total Thrombus Formation Analysis System is an automated microchip flow chamber system that is used for the quantitative analysis of clot formation under blood flow conditions. For several years, researchers have been using a tool to analyse various clinical situations of patients to identify the properties and biochemical processes occurring within platelets and their microenvironment. Methods. An investigation of recent published literature was conducted based on PRISMA. This review includes 52 science papers directly related to the use of the Total Clot Formation Analysis System in relation to bleeding, surgery, platelet function assessment, anticoagulation monitoring, von Willebrand factor and others. Conclusion. Most available studies indicate that The Total Thrombus Formation Analysis System may be useful in diagnostic issues, with devices used to monitor therapy or as a significant tool for predicting bleeding events. However, T-TAS not that has the potential for diagnostic indications, but allows the direct observation of the flow and the interactions between blood cells, including the intensity and dynamics of clot formation. The device is expected to be of significant value for basic research to observe the interactions and changes within platelets and their microenvironment.  相似文献   

8.
In the present work, a new and simple Schiff base‐assisted extraction strategy for Ni and Zn from an edible oil matrix with subsequent determination using a flame atomic absorption spectrometer was suggested. According to the green approach, laborious sample‐pretreatment procedures were eliminated via complexation of the analytes with N,N′‐bis(4‐methoxysalycylidene)‐2‐hydroxy‐1,3‐propanediamine (4MSHP) and transferred from the oil phase to the aqueous phase. The complexation properties of 4MSHP, Ni, and Zn were investigated using UV–vis spectrophotometry. The experimental conditions that affect the extraction efficiency were optimized using central composite design. The optimum conditions for the extraction of Ni and Zn were as follows: a volume to oil mass ratio of 0.83 to 1.31 mL g?1 of 4MSHP solution; 62.3‐ and 50.6‐min, stirring time; 27.3 and 31.1 °C, temperature, respectively. The detection limits (3sbm?1) were 0.41 μg g?1 for Ni and 0.16 μg g?1 for Zn. Validation of the suggested work was performed by the analysis of organometallic standard‐doped n‐hexane solutions as certified reference materials under the optimum experimental conditions. The recovery percentages were warranted the accuracy and found as 98.2 ± 1.8% for Ni and 99.8 ± 1.2% for Zn. In addition, relative SD values were below 5% for both the analytes. The Student's t‐test showed that there was no significant difference between the found and doped amount of analytes at 95% confidence level. The features such as the detection technique, cheapness, eco‐friendly solvent usage, and practicality were better compared to the literature.  相似文献   

9.
Steroid analysis in clinical laboratories is dominated by immunoassays (IAs) that have a high sample turnover but are inherently limited in trueness, precision, and sensitivity. Liquid chromatography coupled to mass spectrometry (LC-MS/MS) has proved to be a far more capable tool, delivering better sensitivity, specificity, and the possibility of parallel analysis of multiple steroids and metabolites, providing the endocrinologist with more reliable and comprehensive diagnostic information. An LC-MS/MS assay with gradient elution over less than eight minutes and a one-step sample preparation combining protein precipitation with phospholipid removal of off-line solid-phase extraction was developed and validated. It allowed the quantification of 11-deoxycorticosterone (11-DOC), 11-deoxycortisol (11-DF), 17-OH-progesterone (17P), 21-deoxycortisol (21-DF), androstenedione (ANDRO), aldosterone (ALDO), corticosterone (CC), cortisol (CL), cortisone (CN), dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), dihydrotestosterone (DHT), estradiol (E2), progesterone (PROG), and testosterone (TES) in human serum. Interday imprecision was generally better than 15%, trueness was proven by recovery experiments with ISO 17034-certified reference materials, proficiency testing (UK NEQAS), and measuring serum reference standards. In-house comparison against IVD-CE-certified immunoassays (IA) for 17P, ANDRO, CL, DHEAS, E2, PROG, and TES was conducted by assessing leftover routine patient samples and purpose-built patient serum pools. None of the compared routine IAs were meeting the standards of the LC-MS/MS. Insufficient overall comparability was found for ANDRO and 17P (mean bias > +65%). Accuracy limitations at lower concentrations were present in IAs for PROG, E2, and TES.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号