首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Five patients severely affected by haemophilia, in whom six knees showed advanced haemophilic arthropathy, have been studied. The patients presented with painful limitation of movement and increasingly frequent episodes of spontaneous bleeding in the affected knees. These all showed secondary degenerative changes and varus deformity. A Corrective osteotomy of the proximal tibia was performed under full haematological cover without complications. Follow-up ranged from 6 to 36 months, with a mean of 18 months. At follow-up all patients were free of pain and had retained their range of movement. In the three patients with a longer follow-up there was radiological improvement. The most significant feature was that there was almost complete cessation of bleeding episodes into the knee in all patients and no progression of the arthropathy. The cost benefit implications of this corrective procedure are discussed.  相似文献   

2.
Knee range of motion was determined in 60 patients to assess the effect of weight bearing on maximal knee flexion. Three patient subgroups were investigated: patients with normal knees, patients implanted with posterior cruciate-retaining (PCR) total knee arthroplasty (TKA), and patients implanted with posterior cruciate-substituting (PS) TKA. Maximal knee flexion was determined using videofluoroscopy both in a passive, non-weight-bearing mode and during active weight bearing. Flexion was diminished with weight bearing in all three subgroups (P < .045). Patients with normal knees exhibited significantly greater knee flexion than either TKA subgroup when measured either with or without weight bearing (P < .001). Knee flexion of both TKA subgroups was similar when measured passively without weight bearing. Patients with PS TKA demonstrated greater flexion than patients with PCR TKA when measured in weight bearing (P < .025), despite having less range of motion and lower clinical performance ratings preoperatively. Measurement of knee range of motion in a weight-bearing fashion may be a superior method of assessment of functional capabilities.  相似文献   

3.
The purpose of this study was to analyze our results of surgical treatment of arthrogryposis of the elbow and to compare our tendon transfer results using range of motion (ROM) criteria versus functional use criteria. Eighteen tendon transfers for elbow flexion in 14 children with arthrogryposis with an average follow-up period of 4 years (range, 1-14 years) and 6 elbow capsulotomies with triceps lengthening in 6 children with arthrogryposis with an average follow-up period of 5 years (range, 2-9 years) were evaluated. Each child was assessed by a questionnaire regarding functional use of the upper extremity, physical examination of ROM and strength, and a videotaped activities of daily living evaluation. Tendon transfer results were classified and compared using 2 methods of evaluation: postoperative strength and ROM and effective functional use of the tendon transfer to perform activities of daily living. The 6 elbow capsulotomies improved from an average preoperative arc of 17 degrees of motion (average extension, -2 degrees; average flexion, 19 degrees) to an average final follow-up arc of 67 degrees (average extension, -25 degrees; average flexion, 92 degrees). The 18 tendon transfers evaluated by strength and ROM criteria showed 9 triceps to biceps transfers in 9 arms (7 good, 1 fair, and 1 poor), 5 pectoralis to biceps transfers in 4 arms (1 good, 3 fair, and 1 poor), and 4 latissimus dorsi to biceps transfers in 3 arms (2 good and 2 fair). Evaluation by functional use criteria gave the same result in 13 transfers and downgraded the result in 5; the downgraded results were due to resultant flexion contracture or limited functional use because the transfer was in the nondominant arm. Based on this review, optimal surgical candidates for tendon transfer are children older than 4 years, who have full passive ROM of the elbow in the dominant arm, and at least grade 4 strength of the muscle to be transferred.  相似文献   

4.
Thirty-eight elbows (thirty-seven patients) with an extrinsic contracture were treated operatively with a limited lateral approach to the anterior and posterior aspects of the capsule. Because the procedure elevates muscles from the anterior and posterior aspects of the lateral supracondylar osseous ridge, we called it the column procedure. The mean preoperative arc of flexion was 49 degrees (from 52 to 101 degrees). At a mean of forty-three months (range, twenty-four to seventy-four months) postoperatively, the mean arc of flexion was 94 degrees (from 27 to 121 degrees). The mean total gain in the arc of flexion-extension was 45 degrees; thirty-four elbows (89 percent) had an improved range of motion at the latest follow-up examination. Overall, thirty-one elbows (82 percent) had a satisfactory result. Greater improvement was obtained in elbows that had had severe stiffness (a total arc of 31 to 60 degrees) or very severe stiffness (a total arc of 30 degrees or less) or that had had a combined flexion and extension contracture. A complication occurred in four elbows (11 percent). A hematoma developed in two elbows and impaired the final outcome in one of them. Two elbows had transient ulnar paresthesia, which resolved spontaneously. The arc of flexion obtained at the time of the operation was lost in ten elbows (26 percent) after an initial period of improvement; at the latest follow-up evaluation, four of these elbows had a mean decrease in the arc of flexion of 24 degrees compared with preoperatively. The column procedure is associated with a low rate of complications and is safe and effective for the treatment of a limitation in flexion or extension resulting from an extrinsic contracture of the elbow.  相似文献   

5.
OBJECTIVE: To review the results of surgical management of heterotopic ossification about the elbow in burned patients. DESIGN: Retrospective analysis with long-term patient follow-up. MATERIALS AND METHODS: Eleven patients with 16 elbows requiring surgery were admitted between January 1, 1982 and December 31, 1993. A posterior approach to the elbow with release of the encased ulnar nerve +/- anterior transposition and transolecranon osteotomy to access extensive bone formation in the olecranon fossa was employed. Eight patients (11 elbows) were available for long-term follow-up conducted at mean 50 +/- 13 months after surgery. Long-term follow-up consisted of measurement of range of elbow motion, as well as clinical assessment of ulnar nerve function. MAIN RESULTS: For the 11 elbows examined postoperatively, the mean range of motion preoperatively in flexion-extension was 11 degrees +/- 5 degrees compared to 89 degrees +/- 12 degrees postoperatively (p < 0.001). Three patients with poor long-term results had ankylosis of the joint preoperatively. Of four patients with ulnar nerve paresis preoperatively, none had ulnar nerve dysfunction at follow-up. Of 16 elbows operated on, four (25%) had postoperative complications. Two suffered soft-tissue breakdown with hardware exposure requiring abdominal flap closure, one early failure of olecranon fixation, and one late infected hardware. CONCLUSIONS: Surgery for both limited range of motion as well as ulnar nerve compression is effective in cases of heterotopic ossification about the elbows of burned patients. Early operative intervention is indicated in progressive disease, particularly ulnar nerve palsy, if soft-tissue quality is adequate. Complications with 25% of elbows suggest that use of olecranon osteotomy for joint access may warrant review.  相似文献   

6.
Maitland's slump test is a widely used neural tissue tension test. During slump testing, terminal knee extension is assessed for signs of restricted range of motion (ROM), which may indicate impaired neural tissue mobility. A number of refinements that modify hip and ankle position has been added to the basic slump test procedure, but no research to date has measured the effects of ankle and hip position on knee extension ROM during testing. The purpose of this study was to examine the effect of neural tension-producing movements of the cervical spine and lower extremity on knee extension ROM during the slump test. Thirty-four males with no significant history of low back pain were tested in the slump position with the cervical spine flexed and extended in each of three lower extremity test positions: neutral hip rotation with the ankle in a position of subject comfort (neutral), neutral hip rotation with ankle dorsiflexion (ankle dorsiflexion), and medial hip rotation with ankle dorsiflexion. Results showed significant decreases in active knee extension ROM (F1,198 = 29.53, p < 0.0001) in the cervical flexion compared with the cervical extension conditions. Subjects also exhibited significant decreases in active knee extension ROM (F2,198 = 56.76, p < 0.0001) as they were progressed from neutral to the ankle dorsiflexion to the medial hip rotation with ankle dorsiflexion positions of the lower extremity. The results of our study indicate that limitations in terminal knee extension ROM may be considered a normal response to the inclusion of cervical flexion, ankle dorsiflexion, or medial hip rotation in the slump test in young, healthy, adult males. In addition, the presence of a cumulative effect on knee extension ROM with the simultaneous application of these motions is noted. These findings may assist clinicians when assessing knee extension ROM during slump testing.  相似文献   

7.
Ten patients (14 knees) with severe knee flexion contractures were treated by gradual mechanical distraction using either the Ilizarov or Orthofix external fixator. Range of motion improved from an average flexion contracture of 60 degrees before surgery to 16 degrees at the follow-up evaluation. Range of motion results were graded good or excellent in five knees, fair in two knees, and poor in three knees. Average total arc of motion remained essentially unchanged when comparing the preoperative (59 degrees) with the follow-up results (63 degrees). However, the functional position of this arc improved significantly. Problems encountered included a "rebound" phenomena after frame removal, with loss of the temporarily increased total arc of motion. The role of hamstring tenotomy and radical posterior knee release remains unclear.  相似文献   

8.
Accurate assessment of elbow function is important to determine the total ability of the arm. The purpose of this study was to clarify the relationship between isometric muscle strength of the elbows of patients with rheumatoid arthritis (RA) and Larsen's X-ray evaluation. Fifty-six elbows of 45 RA patients aged 47 to 77 years (mean age, 63 years) were tested. Muscle strength was measured with an isometric torque-cell dynamometer. Test-retest reliability of the dynamometer was proven by measuring 12 elbows of 6 healthy young men. In RA patients, elbow flexion and extension strength decreased in proportion to increases in the severity of Larsen's grades from Grade 1 to 4. However, Grade 5 elbows had greater muscle strength than those in Grade 4. Forearm pronation and supination strength also decreased in proportion to increases in the severity of Larsen's grades from Grade 1 to 5. This quantitative study made it clear that the muscle strength of RA patients' elbows almost completely correlates to X-ray finding according to the grade of Larsen's evaluation based on X-rays. With regard to muscle strength of postoperative elbows, both flexion strength and supination strength after total elbow replacement (TER) were about two times greater than before TER, and after synovectomy it was as great as those in non-operative RA patients of Grade 2.  相似文献   

9.
OBJECTIVES: To review long-term prophylactic factor treatment in young patients with severe haemophilia A and B, focusing on the orthopaedic and radiological outcome. DESIGN: We received 34 patients with severe haemophilia A (n = 29) and B (n = 5), aged 7-22 years. Age at start of treatment was 1-4.5 years. Dosages of factor concentrate (F VIII and F IX, respectively) were 25-40 IU/kg body weight, three times a week for haemophilia A and twice a week for haemophilia B. The patients had been checked annually over a 5-year period (1990-95). Orthopaedic and radiological joint scores were evaluated according to recommendations by the World Federation of Haemophilia. SETTING: All results were obtained at the Department for Coagulation Disorders, University of Lund, Malm? University Hospital, Malm?, Sweden. RESULTS: Orthopaedic and radiological joint scores were found to have remained unchanged during follow-up in almost all patients and to be still zero (i.e. no unaffected joints) in 79% (n = 27) of the patients. CONCLUSION: There is a growing international consensus haemophilic arthropathy can be prevented by administering early high-dose prophylaxis. The results of the present investigation strongly support this opinion.  相似文献   

10.
OBJECTIVE: To determine the effects of continuous passive motion (CPM) and immobilization on synovitis and cartilage degradation in an experimental model of chronic inflammatory, antigen-induced arthritis. METHODS: After bilateral arthritis induction of knee joints in 22 NZW rabbits, one knee was immobilized with a flexion splint while the opposite knee received CPM. RESULTS: After 2 weeks (n = 10), the CPM treated knees had significantly greater joint swelling, synovial effusion, and histologic synovitis scores compared to its opposite immobilized knees. However, the total cartilage degradation score showed no statistically significant difference between the two treatments. When the treatments were discontinued after 2 weeks and animals were allowed intermittent active motion of both knees in cages for 4 weeks (n = 12), no statistically significant difference in joint swelling, synovial effusion, and histologic synovitis score was observed between the 2 treatments. The articular cartilage degradation, however, was significantly greater in the immobilized knees compared to its opposite CPM treated knees. Five of 12 immobilized knees had articular surface erosion compared to none in the CPM treated knees. Loss of cellularity was also significantly greater in the immobilized knees. CONCLUSION: Although CPM produced greater synovitis at 2 weeks, articular cartilage was better preserved in the knees treated with CPM than immobilization at 6 weeks.  相似文献   

11.
The functional performance of the knee joints of 29 normal volunteers, 65 patients with degenerative joint disease and 30 patients with rheumatoid arthritis was studied according to clinical (historical, physical and roentgenographic) and biomechanical gait parameters. Temporal and distance gait factors (velocity, cadence and stride length) were significantly reduced in patients with diseased knees. Sagittal plane knee motion was markedly reduced, as was stance phase flexion, indicating poor tolerance of loading the flexed knee in the patient groups. There was no correlation between passive motion of the diseased knee and the amount of motion used during gait. Patients with rheumatoid arthritis generally showed more compromise of knee joint function than did patients with degenerative joint disease. Statistically, significant correlations between various clinical and biomechanical gait parameters suggest that the techniques used are an objective measurement of knee joint function and may be employed as a means of evaluating various treatment modalities for the diseased knee.  相似文献   

12.
Elbow joint disorders were studied in relation to vibration exposure and age in 74 male stone quarry workers who operated mainly chipping hammers and sometimes rock drills. They were examined for range of active motion in elbow extension and flexion, and by means of radiographs of the elbow joint. Effects of age and vibratory tool operation on the elbow joint were statistically estimated using multiple regression analysis. In the analysis of all subjects, including those aged over 60 years, age was significantly related to the range of motion in extension and to radiographic changes in both elbows, and the duration of vibratory tool operation was associated with the range of right elbow flexion. Among subjects under the age of 60 years, duration of vibratory tool operation showed a significant dose-effect relationship to the range of flexion and radiographic changes in the right elbow, but there was no significant relationship with age. The present results suggest that the operation of chipping hammers and rock drills contributes to elbow joint disorders or osteoarthrosis, even when the effect of age is taken into account. Besides vibration exposure, it may be necessary to consider various loads on the elbow joint such as firmly grasping and pressing the tool against stones with the arm bent at about 90 degrees, and carrying stones.  相似文献   

13.
We report the case of a severe haemophilia A patient with an anti-factor VIII antibody who presented with a thigh haematoma and 1 year later with an elbow haemarthrosis infected by Salmonella enteritidis. These two infections were treated by antibiotics. The probable origin of these infections seems to be an anal fistula. The occurrence of a septic arthritis due to Salmonella is rare, and to our knowledge has never been reported in HIV-negative haemophilic patients. The differential diagnosis of haemarthrosis and septic arthritis in a haemophilic patient is also discussed.  相似文献   

14.
Between January 1980 and January 1994, 31 knees required distal realignment of the extensor mechanism to treat lateral patellar subluxation that could not be corrected with lateral patellar release and vastus medialis advancement during total knee arthroplasty. Fifteen had a preoperative valgus angle of more than 12 degrees, and 16 were undergoing revision total knee arthroplasty. Ten knees had a modified Roux-Goldthwait procedure, 18 had medial tibial tubercle transfer, and three had medial transfer of the medial 1/2 of the patellar tendon. The length of followup ranged from 2 to 16 years. No late patellar subluxations or dislocations have occurred in any of these cases. Three cases of medial tibial tubercle transfer had hematomas develop, with two requiring surgical evacuation; one of these developed a late infection. No fractures or displacements of the tubercle fragment have occurred. No significant patellar complications have occurred in those patients who underwent the modified Roux-Goldthwait procedure or the medial transfer of the medial 1/2 of the patellar tendon. One year after surgery, the mean knee flexion was 113 degrees, four knees had a flexion contracture of 5 degrees, and none had a quadriceps lag.  相似文献   

15.
This is a retrospective study of 10 patients with combined cruciate ligament and posterolateral instability who underwent surgical reconstruction between 1991 and 1994. All knees had at least 20 degrees increased external rotation at 30 degrees of knee flexion and from 1+ to 3+ varus instability. Five knees with posterior cruciate ligament ruptures had at least a 2+ Lachman test result. (One knee had both anterior and posterior cruciate ligament injuries). In all cases the lateral collateral ligament was reconstructed with a bone-patellar tendon-bone allograft secured with interference screws. Fixation tunnels were placed in the fibular head and at the isometric point on the femur. The cruciate ligaments were reconstructed with autograft or allograft material. The average follow-up was 28 months. Excessive external rotation at 30 degrees of flexion was corrected in all but one knee. Six patients had no varus laxity, and four patients had 1+ varus laxity at 30 degrees of flexion. The posterior drawer test result decreased, on average, to 1+, and the Lachman test result decreased to between 0 and 1+. The average Tegner score was 4.6, with five patients returning to their preinjury level of activity and four returning to one level lower. These results indicate that this is a promising new procedure for patients with instability resulting from lateral ligament injuries of the knee.  相似文献   

16.
We conducted a prospective study of 94 consecutive patients who received a patellar tendon autograft for anterior cruciate ligament rupture. Eighty-seven patients (93%) returned for followup a mean of 28 months postoperatively; 57 had chronic and 30 had acute or subacute ruptures. There were no significant differences between the subgroups for age, sex, articular cartilage lesions, or months of followup. Forty-six meniscal tears were repaired; 27 of these extended into the central avascular region. Rehabilitation emphasized immediate knee motion, but strenuous activity was delayed for at least 4 months. Only one patient had a knee motion complication, and stability (<3 mm, KT-2000 arthrometer, 134 N) was restored in 85% of knees with chronic ruptures and 92% of knees with acute ruptures. Earlier reconstruction should be considered in active persons as symptoms and limitations continued postoperatively in knees with chronic ruptures, leading to overall less satisfactory results. In patient rating of the overall knee condition, 69% of knees with chronic ruptures and 100% of knees with acute ruptures scored in the normal or very good range. Repair of meniscal tears that extend into the central avascular region should be considered, as 24 of the 27 (89%) menisci repaired showed clinical evidence of healing and did not require reoperation.  相似文献   

17.
A review of pre- and postoperative prone knee flexion (PKF) data after isolated hamstring tenotomy for 52 patients with cerebral palsy (CP) at an average follow-up of 3 years 4 months showed the frequency of diminished knee flexion to be 71%. Twenty-three percent of the knees actually had improved flexion, whereas 6% were unchanged. On the average, patients' flexion decreased 14.4 degrees from a preoperative PKF of 131.5 degrees to 117.1 degrees postoperatively (p < 0.0001). Only 11.5% of patients had PKF < 90 degrees at most recent follow-up, however; only 1.9% had PKF < 60 degrees. Thirteen percent of ambulators eventually required a rectus femoris transfer to correct "stiff-legged gait."  相似文献   

18.
Polycentric total knee arthroplasty provided significant relief of pain in 86 per cent of 500 knees. The independence and activity levels of the patients increased dramatically. The frequency of major complications as reflected by reoperation was 10 per cent in this series. There was a 2.8 per cent deep infection rate. One-third of the infected knees were salvaged and two-thirds required arthrodesis. Loosening of a component was noted in 2.4 per cent. After operation the average range of motion was from 6 to 101 degrees of flexion, for a range of 95 degrees; this was a 5-degree increase over average preoperative motion. Ninety-six per cent of the patients expressed satisfaction with the surgical result.  相似文献   

19.
The results of nineteen semiconstrained modified Coonrad-Morrey total elbow arthroplasties performed in nineteen patients to treat instability were evaluated at an average of seventy-two months (range, twenty-five to 128 months) postoperatively. Preoperatively, all patients had either a flail elbow or gross instability of the elbow that prevented useful function of the extremity. The instability of sixteen elbows was the result of a traumatic injury or of the treatment of such an injury. The most recent result was satisfactory for sixteen elbows and unsatisfactory for three. The average overall Mayo elbow performance score increased from 44 points preoperatively to 86 points postoperatively. At the most recent follow-up examination, no elbow was unstable. The average arc of flexion was from 25 degrees (range, 0 to 60 degrees) to 128 degrees (range, 30 to 142 degrees), which represented a 58-degree increase from the preoperative average arc. Sixteen patients had little or no pain after the arthroplasty. There were four complications in four patients. Three complications (loosening of the humeral component in one patient and a fracture of the ulnar component in two) occurred postoperatively; all three were treated with a revision procedure. The other complication (a fracture of the olecranon) occurred intraoperatively and was treated with tension-band fixation; the most recent outcome was not affected. Radiographically, one patient had complete (type-V) radiolucency about the humeral component. None of the nine patients for whom true anteroposterior radiographs were available had evidence of wear of the bushings. The bone graft behind the anterior flange of the humeral prosthesis was mature in fourteen elbows, incomplete in two, and resorbed in two. One patient was excluded from this analysis because radiographs were not available. Instability of the elbow resulting in the inability to use the extremity is a challenging clinical situation. However, in patients who are more than sixty years old and in selected patients who are less than sixty years old but who have extensive loss of bone as a result of severe injury, have had multiple operations, or have rheumatoid arthritis, total elbow arthroplasty with a linked, semiconstrained prosthesis reestablishes a mobile, stable joint without premature loosening or failure of the components. In our experience, the use of customized implants, maintenance of the muscular attachments to the epicondyles, and reconstruction of the epicondyles to the implant were unnecessary.  相似文献   

20.
OBJECTIVE: To describe a new method for measuring lateral neck flexion range of motion (ROM), document the reliability of the method and present estimates of normal. SUBJECTS: One hundred thirty-five subjects ranging in age from 14-95 yr. Two physical therapists with 13 and 2 yr of experience, respectively, served as testers. INTERVENTION: Measurement of active lateral neck flexion ROM using a universal goniometer modified by the placement of a portion of a small paper clip through the axis. The goniometer arms were aligned with the subject's nose, and the free-swinging paper clip (pendulum) was used as a marker. The more experienced therapist measured lateral flexion of 100 subjects to establish intratester reliability and estimates of normal. Both therapists measured 35 subjects to determine intertester reliability. MAIN OUTCOME MEASURE: Degrees of lateral neck flexion. RESULTS: Intraclass correlation coefficients for intratester reliability exceeded 0.90. Coefficients for intertester reliability were 0.86 and 0.65. ROM decreased with increasing age. CONCLUSION: The modified goniometer is inexpensive, easy to use and can yield high intratester reliability and satisfactory intertester reliability. The estimates of normal provide preliminary values with which a patient's lateral neck flexion ROM can be compared.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号