Tan Z  Long X 《Applied spectroscopy》2012,66(5):492-495
A developed spectrometer based on optical-feedback cavity ring-down spectroscopy (OF-CRDS) has been demonstrated with a distributed feedback laser diode and a V-shaped glass ceramic cavity. The laser is coupled to the V-shaped cavity, which creates an absorption path length greater than 2.8 km, and resonance between the laser frequency and the cavity modes is realized by modulating the cavity length instead of tuning the laser wavelength to obtain a higher resolution. A noise-equivalent absorption coefficient of ~2.6 × 10(-8) cm(-1)Hz(-1/2) (1σ) is determined with spectral resolution of ~0.003 cm(-1) and spectral range of 1.2 cm(-1). As an application example, the absorption spectrum measurement of water vapor in the spectral range of 6590.3~6591.5 cm(-1) is demonstrated with this spectrometer.  相似文献   

2.
We report a study on the cavity ringdown spectroscopy of acetone in both the ultraviolet (UV) and the near-infrared (NIR) spectral regions to explore the potential for development of a breath analyzer for disease diagnostics. The ringdown spectrum of acetone in the UV (282.4-285.0 nm) region is recorded and the spectrum is in good agreement with those obtained by other spectral techniques reported in the literature. The absorption cross-section of the C-H stretching overtone of acetone in the NIR (1632.7-1672.2 nm) is reported for the first time and the maximum absorption cross-section located at 1666.7 nm is 1.2 x 10(-21) cm(2). A novel, compact, atmospheric cavity with a cavity length of 10 cm has been constructed and implemented to investigate the technical feasibility of the potential instrument size, optical configuration, and detection sensitivity. The detection limit of such a mini cavity employing ringdown mirrors of reflectivity of 99.85% at 266 nm, where acetone has the strongest absorption, is approximately 1.5 ppmv based on the standard 3 criteria. No real breath gas samples are used in the present study. Discussions on the detection sensitivity and background spectral interferences for the instrument development are presented. This study demonstrates the potential of developing a portable, sensitive breath analyzer for medical applications using the cavity ringdown spectral technique.  相似文献   

3.
We present a spectrometer for sensitive absorption measurements in liquids across broad spectral bandwidths. The spectrometer combines the unique spectral properties of incoherent supercontinuum light sources with the advantages of cavity ring-down spectroscopy, which is a self-calibrating technique. A custom-built avalanche photodiode array is used for detection, permitting the simultaneous measurement of ring-down times for up to 64 different spectral components at nanosecond temporal resolution. The minimum detectable absorption coefficient was measured to be 3.2 × 10(-6) cm(-1) Hz(-1/2) at 527 nm. We show that the spectrometer is capable of recording spectral differences in trace levels of blood before and after hemolysis.  相似文献   

4.
We present initial results obtained from an optical absorption sensor for the monitoring of ambient atmospheric nitrogen dioxide concentrations (0-200 ppb). This sensor utilizes cavity attenuated phase shift spectroscopy, a technology related to cavity ringdown spectroscopy. A modulated broadband incoherent light source (a 430-nm LED) is coupled to an optically resonant cavity formed by two high-reflectivity mirrors. The presence of NO(2) in the cell causes a phase shift in the signal received by a photodetector that is proportional to the NO(2) concentration. The sensor, which employed a 0.5-m cell, was shown to have a sensitivity of 0.3 ppb in the photon (shot) noise limit. Improvements in the optical coupling of the LED to the resonant cavity would allow the sensor to reach this limit with integration times of 10 s or less (corresponding to a noise equivalent absorption coefficient of <1 x 10(-8) cm(-1) Hz(-1/2)). Over a 2-day-long period of ambient atmospheric monitoring, a comparison of the sensor with an extremely accurate and precise tunable diode laser-based absorption spectrometer showed that the CAPS-based instrument was able to reliably and quantitatively measure both large and small fluctuations in the ambient nitrogen dioxide concentration.  相似文献   

5.
A narrow-linewidth pulsed alexandrite laser has been greatly modified for improved spectral stability in an aircraft environment, and its operation has been evaluated in the laboratory for making water-vapor differential absorption lidar measurements. An alignment technique is described to achieve the optimum free spectral range ratio for the two étalons inserted in the alexandrite laser cavity, and the sensitivity of this ratio is analyzed. This technique drastically decreases the occurrence of mode hopping, which is commonly observed in a tunable, two-intracavity-étalon laser system. High spectral purity (> 99.85%) at 730 nm is demonstrated by the use of a water-vapor absorption line as a notch filter. The effective cross sections of 760-nm oxygen and 730-nm water-vapor absorption lines are measured at different pressures by usingthis laser, which has a finite linewidth of 0.02 cm(-1) (FWHM). It is found that for water-vapor absorption linewidths greater than 0.04 cm(-1) (HWHM), or for altitudes below 10 km, the laser line can be considered monochromatic because the measured effective absorption cross section is within 1% of the calculated monochromatic cross section. An analysis of the environmental sensitivity of the two intracavity étalons is presented, and a closed-loop computer control for active stabilization of the two intracavity étalons in the alexandrite laser is described. Using a water-vapor absorption line as a wavelength reference, we measure a long-term frequency drift (≈ 1.5 h) of less than 0.7 pm in the laboratory.  相似文献   

6.
To our knowledge we present the first experiments with a fully reflective external-cavity quantum-cascade laser system at mid-infrared wavelengths for use as a local oscillator in a heterodyne receiver. The performance of the presented setup was investigated using absorption spectroscopy as well as heterodyne techniques. Tunability over approximately 30 cm(-1) at 1130 cm(-1) was demonstrated using a grating spectrometer. A continuous tuning range of 0.28 cm(-1) was verified by observing the spectra of an internally coupled confocal Fabry-Pérot interferometer and the absorption lines of gas phase SO(2). In a second step the output from the system was used as a local oscillator signal for a heterodyne setup. We show that spectral stability and side mode suppression are excellent and that a compact external-cavity quantum-cascade laser system is well suited to be used as a local oscillator in infrared heterodyne spectrometers.  相似文献   

7.
Paul JB  Lapson L  Anderson JG 《Applied optics》2001,40(27):4904-4910
A simple and easy to use method that allows high-finesse optical cavities to be used as absorption cells for spectroscopic purposes is presented. This method introduces a single-mode continuous-wave laser into the cavity by use of an off-axis cavity alignment geometry to eliminate systematically the resonances commonly associated with optical cavities, while preserving the absorption signal amplifying properties of such cavities. This considerably reduces the complexity of the apparatus compared with other high-resolution cavity-based absorption methods. Application of this technique in conjunction with either cavity ringdown spectroscopy or integrated cavity output spectroscopy produced absorption sensitivities of 1.5 x 10(-9) cm(-1) Hz(-1/2) and 1.8 x 10(-10) cm(-1) Hz(-1/2), respectively.  相似文献   

8.
We describe the performance of a high-sensitivity wavelength modulated cavity enhanced infrared tunable diode laser absorption spectrometer for the detection of water vapor in the 1.37 mum region. The spectrometer can measure a fractional absorption of approximately 10(-5) for an absorption path length of a few kilometers. The instrument's sensitivity is more than sufficient to detect water isotopomers (H(2)(16)O, H(2)(18)O, HDO) at Martian atmospheric concentrations. The instrument is amenable to miniaturization, so a future compact, multiple-species version of the spectrometer will be highly suitable for in situ planetary exploration.  相似文献   

9.
Transmission spectroscopy over large spectral ranges (>100?cm(-1)) generally requires a reference measurement to be taken separately from the sample scan. The ratio of the two measurements (i.e., the transmittance) is therefore susceptible to baseline changes that occur between the recording of the two spectra. The origins of relatively strong baseline changes (?1%) of a difference-frequency-generation-based laser spectrometer (tuning range 2900-3144?cm(-1), 150?μW average power) were investigated and a method for minimizing them by improving reproducibility and reducing measurement time is presented. The new method was tested for a gas mixture and the sensitivity for broad absorption features was determined as 5×10(-3) minimum measurable absorbance for a total scan duration of 70?min.  相似文献   

10.
Fiber-loop cavity ring-down spectroscopy (CRDS) is a highly sensitive spectroscopic absorption technique which has shown considerable promise for the analysis of small-volume liquid samples. We have developed a new light coupling method for fiber-loop CRDS, which overcomes two disadvantages of the technique: low efficiency light coupling into the cavity and high loss per pass. The coupler is based on a 45° reflective notch polished between 10 and 30 μm into the core of a large-core-diameter (365 μm) optical fiber, and allows for nearly 100% light coupling into the cavity, with a low loss per pass (<4%). The coupler has the additional advantage that the input and output light is spatially separated on opposite sides of the fiber. The detection sensitivity of a fiber-loop CRD spectrometer employing the new coupling method is established from ring-down measurements on aqueous rhodamine 6G (Rh6G) at 532 nm. The results are compared with data obtained using the same light source and detector, but a conventional bend-coupled small-core-diameter (50 μm) optical fiber loop. With our new coupler, a detection limit of 0.11 cm(-1) is found, which corresponds to detection of 0.93 μM Rh6G in a volume of only 19 nL. This is an improvement of over an order of magnitude on our bend-coupled small-core optical fiber results, in which a detection limit of 5.3 cm(-1) was found, corresponding to a detection of 43 μM Rh6G in a volume of 20 pL.  相似文献   

11.
von Lerber T  Sigrist MW 《Applied optics》2002,41(18):3567-3575
A novel measurement principle for fiber-optic sensing is presented. Use of a cavity-ring-down scheme enables measurements of minute optical losses in high-finesse fiber-optic cavities. The loss may be induced by evanescent-field absorption, fiber bending, fiber degradation, Bragg gratings, or any other effect that might change the fiber transmission or cavity reflector properties. The principle is proved to be rather insensitive to ambient perturbations such as temperature changes. A high-sensitivity measurement of loss due to bending is presented as a proof-of-principle. With a cavity finesse of 627 a sensitivity for induced loss of 108 ppm (4.68 x 10(-4) dB) is achieved. Preliminary measurements of evanescent-field absorption are also discussed.  相似文献   

12.
Rao GN  Karpf A 《Applied optics》2011,50(13):1915-1924
We report on the development of a new sensor for NO? with ultrahigh sensitivity of detection. This has been accomplished by combining off-axis integrated cavity output spectroscopy (OA-ICOS) (which can provide large path lengths of the order of several kilometers in a small volume cell) with multiple-line integrated absorption spectroscopy (MLIAS) (where we integrate the absorption spectra over a large number of rotational-vibrational transitions of the molecular species to further improve the sensitivity). Employing an external cavity quantum cascade laser operating in the 1601-1670 cm?1 range and a high-finesse optical cavity, the absorption spectra of NO? over 100 transitions in the R band have been recorded. From the observed linear relationship between the integrated absorption versus concentration of NO? and the standard deviation of the integrated absorption signal, we report an effective sensitivity of detection of approximately 28 ppt (parts in 1012) for NO? To the best of our knowledge, this is among the most sensitive levels of detection of NO? to date.  相似文献   

13.
Atmospheric nitrate radicals (NO3) are detected using off-axis cavity ringdown spectroscopy (CRDS) for the first time to our knowledge with a room-temperature continuous-wave (cw) diode laser operating near 662 nm. A prototype instrument was constructed that achieved a 1sigma absorption sensitivity of 5 x 10(-10) cm(-1) Hz(-1/2), corresponding to a 1.4 part per trillion by volume 2sigma detection limit in 4.6 s at 80 degrees C. This sensitivity is a significant improvement over a recent implementation of off-axis cavity-enhanced absorption spectroscopy and comparable to that of the most advanced cw CRDS and pulsed CRDS applications for atmospheric detection of NO3. A comparison of measurements of ambient air in Fairbanks, Alaska, recorded with the off-axis CRDS instrument and a previously characterized conventional cw CRDS instrument showed good agreement (R2 = 0.97).  相似文献   

14.
An integrated fiber-optic sensor is described that uses incoherent broadband cavity enhanced absorption spectroscopy for sensitive detection of aqueous samples in nanoliter volumes. Absorption was measured in a 100 μm gap between the ends of two short segments of multimode graded-index fiber that were integrated into a capillary using a precision machined V-grooved fixture that allowed for passive fiber alignment. The other ends of the fibers were coated with dielectric mirrors to form a 9.5 cm optical resonator. Light from a fiber-coupled superluminescent diode was directly coupled into one end of the cavity, and transmission was measured using a fiber-coupled silicon photodiode. Dilute aqueous solutions of near infrared dye were used to determine the minimum detectable absorption change of 2.4×10(-4) under experimental conditions in which pressure fluctuations limited performance. We also determined that the absolute minimum detectable absorption change would be 1.6×10(-5) for conditions of constant pressure in which absorption measurement is limited by electronic and optical noise. Tolerance requirements for alignment are also presented.  相似文献   

15.
We demonstrate a simple periodically locked cw cavity ringdown spectroscopy technique that enables a very large number of ringdown events to be rapidly acquired. An external cavity diode laser is locked to a high-finesse cavity, and as many as 16,000 ringdown events per second are obtained by periodically switching off the light entering the high-finesse cavity. Following each ringdown event, the light to the cavity is switched back on and cavity lock is rapidly reacquired. Limited only by our relatively modest digitization rate, we obtained a minimum detectable absorption loss of 4.7 x 10(-9) cm(-1), but we show that faster digitization could provide a sensitivity of 5.9 x 10(-10) cm(-1) Hz(-1/2).  相似文献   

16.
Cheng J  Lin H  Hu S  He S  Zhu Q  Kachanov A 《Applied optics》2000,39(13):2221-2229
High-quality broadband infrared high-resolution spectra were obtained by use of the intracavity laser absorption spectroscopy technique with a Ti:sapphire laser in combination with a continuous-scan Fourier-transform (FT) interferometer. With electronic filtering used to smooth out the fluctuations of the laser power, the absorption of atmospheric water vapor in the range of 12,450-12,700 cm(-1) was recorded at a resolution of 0.05 cm(-1). A signal-to-noise ratio of greater than 300 was observed in this spectrum, corresponding to a minimum detectable absorption of approximately 2 x 10(-9) cm(-1). Comparison with previous measurements by use of a conventional FT technique shows that this method gives absorption spectra with highly accurate line positions along with reasonable line intensities. Investigation of the evolution of intracavity laser absorption spectra with the generation time is also shown to be possible with a continuous-scan FT spectrometer by use of the interleave rapid-scan method.  相似文献   

17.
Manne J  Lim A  Jäger W  Tulip J 《Applied optics》2010,49(28):5302-5308
A pulsed, distributed feedback (DFB) quantum cascade (QC) laser centered at 970 cm(-1) was used in combination with an off-axis cavity enhanced absorption (CEA) spectroscopic technique for the detection of ammonia and ethylene. Here, the laser is coupled into a high-finesse cavity with an optical path length of ~76 m. The cavity is installed into a 53 cm long sample cell with a volume of 0.12 L. The laser is excited with short current pulses (5-10 ns), and the pulse amplitude is modulated with an external current ramp, resulting in a ~0.3 cm(-1) frequency scan. A demodulation approach followed by numerical filtering was utilized to improve the signal-to-noise ratio. We demonstrated detection limits of ~15 ppb and ~20 ppb for ammonia and ethylene, respectively, with less than 5 s averaging time.  相似文献   

18.
Marcus GA  Schwettman HA 《Applied optics》2002,41(24):5167-5171
To demonstrate the potential of the cavity ringdown technique in mid-infrared spectroscopy of thin film samples, we measured absorption losses in a C60 film on a BaF2 substrate using a tunable optical parametric amplifier source. With a Brewster angle sample geometry, we achieved a fractional loss sensitivity as small as 1.3 x 10(-7) with 1.5 cm(-1) resolution, an improvement in sensitivity of 2 orders of magnitude compared to standard Fourier transform infrared methods. At an absorption sensitivity of 5 x 10(-7), spectra of several C60 overtone lines were recorded.  相似文献   

19.
Keith DW  Dykema JA  Hu H  Lapson L  Anderson JG 《Applied optics》2001,40(30):5463-5473
The interferometer for emission and solar absorption (INTESA) is an infrared spectrometer designed to study radiative transfer in the troposphere and lower stratosphere from a NASA ER-2 aircraft. The Fourier-transform spectrometer (FTS) operates from 0.7 to 50 mum with a resolution of 0.7 cm(-1). The FTS observes atmospheric thermal emission from multiple angles above and below the aircraft. A heliostat permits measurement of solar absorption spectra. INTESA's calibration system includes three blackbodies to permit in-flight assessment of radiometric error. Results suggest that the in-flight radiometric accuracy is ~0.5 K in the mid-infrared.  相似文献   

20.
Fung KH  Lin HB 《Applied optics》1986,25(5):749-752
A novel laser intracavity photothermal detector is described. In this scheme, sample absorption of the pump laser power takes place within the cavity of a probe He-Ne laser causing modulation in the gain and in turn the output power. Comparison of this intracavity detector with two other photothermal techniques, namely, phase fluctuation optical heterodyne spectroscopy and thermal beam deflection, is made in terms of practicality and sensitivity. For in situ measurements, sensitivity of 0.5 x 10(-7) cm(-1) for a probe length of 3 cm has been achieved.  相似文献   