1.
Owing to the highly efficient two‐photon fluorescence of gold nanorods and very short fluorescence lifetime compared with the rotational correlation time, the rotation and diffusion of a single gold nanorod can be easily observed by two‐photon fluorescence correlation spectroscopy (TP‐FCS). This property, along with the previous successful use as a contrast agent in two‐photon fluorescence imaging, suggests a potential application in TP‐FCS as well. Although the FCS measurement becomes highly efficient with gold nanorods as probes, the amplitude and temporal decay of the measured correlation functions depend critically on excitation power. Here, we investigate various photophysical processes of gold nanorods to determine the cause of such a sensitive power dependency. This understanding provides a basis for choosing appropriate FCS models to recover reasonable physical parameters. Although the correlation function amplitude G(0) is 32 times lower when the excitation power increases from 20 µW to 1.12 mW, the application of a saturation‐modified FCS model yields very good fit to each data set and the fitted concentration of 0.64 nM is comparable to the 0.7 nM given by the inductively coupled plasma mass spectrometry measurement. The FCS assay appears to be an efficient method for the quantification of gold nanorods when correctly interpreted. However, even with the saturation considered in the fitting model, the fitted rotational and translational diffusion rates are getting faster as the power increases. This indicates that other effects such as photothermal effects may raise the local temperature, and thus increasing the rotational and translational diffusion rate. Microsc. Res. Tech. 76:882–889, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

2.
We have characterized a commercial confocal scanning head for the detection of single molecule fluorescence by two-photon excitation. We have verified that the distribution of the fluorescence emitted by dyes and labeled proteins on glass substrates is discrete with quanta proportional to a common reference signal. We describe and test a simple and quantitative tool to discriminate between single molecules and molecular aggregates on single snapshots based on the analysis of the intensity distribution. We have verified the square dependence of the fluorescence intensity vs. the excitation power, suggesting that no appreciable saturation and fast photo-damage of the chromophores takes place at the excitation power employed here.  相似文献   

3.
Excitation saturation can dramatically alter the effective imaging point spread function (PSF) in two-photon fluorescence microscopy. The saturation-modified PSF can have important implications for resolution in fluorescence imaging as saturation leads to both an increased fluorescence observation volume and an altered spatial profile for the PSF. We introduce here a computational approach to accurately quantify molecular excitation profiles that represent the modified imaging PSF in two-photon microscopy under the influence of excitation saturation. An analytical model that accounts for pulsed laser excitation is developed to calculate the influence of saturation at any location within the excitation laser profile. The overall saturation modified molecular excitation profiles are then evaluated numerically. Our results demonstrate that saturation can play an important role in two-photon fluorescence microscopy even with relatively modest excitation levels.  相似文献   

4.
A modified fluorescence correlation microscope (FCM) was built on a commercial confocal laser scanning microscope (CLSM) by adding two sensitive detectors to perform fluorescence correlation spectroscopy (FCS). A single pinhole for both imaging and spectroscopy and a simple slider switch between the two modes thus facilitate the accurate positioning of the FCS observation volume after the confocal image acquisition. Due to the use of a single pinhole for CLSM and FCS the identity of imaged and spectroscopically observed positions is guaranteed. The presented FCM system has the capability to position the FCS observation volume at any point within the inner 30% of the field of view without loss in performance and in the inner 60% of the field of view with changes of FCS parameters of less than 10%. A single pinhole scheme for spatial fluorescence cross correlation spectroscopy performed on the FCM system is proposed to determine microfluidic flow angles. To show the applicability and versatility of the system, we measured the translational diffusion coefficients on the upper and lower membranes of Chinese hamster ovary cells. Two-photon excitation FCS was also realized by coupling a pulsed Ti: sapphire laser into the microscope and used for flow direction characterization in microchannels.  相似文献   

5.
Chen J  Zhuo S  Luo T  Jiang X  Zhao J 《Scanning》2006,28(6):319-326
The spectral properties of one-photon, two-photon excited autofluorescence and second harmonic generation (SHG) from ex vivo human skin induced by a femtosecond (fs) laser and three visible lasers in backscattering geometry are systematically investigated. Our experimental results indicate that peak position of autofluorescence spectra from the dermis and epidermis shift toward long wavelengths, and the fluorescent intensity decreases when the excitation wavelength increases due to an effect of the excitation wavelength on autofluorescence signals. However, the intensity of the SHG signal in collagen has the maximal value of 800 nm excitation wavelength. This may be the result that the energy of the SHG signal is in resonance with an electronic absorption band. The two-photon excited autofluorescence and SHG intensity all obey a quadratical dependence on the excitation power. Compared with the two-photon excited fluorescence and SHG, the one-photon excited fluorescence in the dermis and epidermis exhibits different spectral characteristics. The investigation of the spectral characteristics of autofluorescence and SHG from ex vivo human skin can provide new insights into morphologic structures and biochemical components of tissues, which are vital for improving the application of laser-induced autofluorescence and SHG spectroscopy technique for noninvasive in vivo tissue diagnostics.  相似文献   

6.
The effects of fluorescence saturation on imaging in confocal microscopy have been studied. To include saturation it was necessary to deviate from the widely assumed linear relationship between the fluorescence and the illumination intensity. The lateral response for a point-like object, as well as the optical sectioning power, decreases depending on the degree of saturation. For very high illumination intensities the response for a saturated point object approached that of a conventional fluorescence microscope in which the fluorescence was not saturated. The decrease in the axial confocal response has been confirmed qualitatively by experiment.  相似文献   

7.
An innovative, portable fluorescence reader was developed for the determination of C-reactive protein based on a lateral flow immunoassay. The C-reactive protein concentration was proportional to the intensity of the test line which was calibrated relative to the control line. To quantify the fluorescence intensity of the lateral flow strip, a custom illumination module, which concentrated the excitation beam from an ultraviolet light-emitting diode, was developed for strip scanning. Accordingly, a high sensitive photodiode with a preamplifier was chosen as the detector for fluorescence. For good repeatability, the strip scanning resolution was set to 5 μm between data points by controlling a linear stage actuated by a stepper motor. Four double-logistic calibration models were compared. The sensitivity for C-reactive protein was 0.1 mg/L and the linear dynamic range extended to 400 mg/L. The optical reader provides a new and simple approach for the determination of C-reactive protein and may be modified for other similar biomarkers.  相似文献   

8.
The relationship between integrated fluorescence intensity and integrated absorbance was measured in Feulgen-stained pigeon erythrocyte nuclei hydrolysed for different periods of time and stained at different dye concentrations. In conventional as well as confocal quantitative fluorescence microscopy the relationship between the integrated fluorescence intensity and the integrated absorbance shows a maximum. This is due to inner filtering and re-absorption of the excitation light and emission light respectively. In conventional quantitative fluorescence microscopy the relationship is influenced by the numerical aperture of the objective lens. Under confocal observation, as measured with the BIO-RAD MRC-500 Confocal Imaging System, no influence of the numerical aperture of the objective lens on the relationship between the integrated fluorescence intensity and the integrated absorbance could be observed.  相似文献   

9.
Two-photon activation of photoactivatable green fluorescent protein (PA-GFP) provides a unique tool for probing cellular transport processes, because activation is strictly limited to the sub-femtoliter optical volume of the two-photon spot. We demonstrate two-photon activation of PA-GFP immobilized in a gel and freely diffusing within cells and recover a quadratic power dependence. Illumination at 820 nm allows simultaneous activation and fluorescence monitoring by two-photon excitation. Alternatively, we activate PA-GFP using two-photon excitation and monitor the fluorescence of the photoconverted product with one-photon excitation. We probe nucleocytoplasmic transport through the nuclear pore complex of COS-1 cells, by observing the time-dependent fluorescence at various locations within the cell after two-photon activation of PA-GFP in the nucleus and in the cytoplasm. Two-photon activation of a tandem construct of two PA-GFPs showed a markedly slower rate of crossing through the nuclear pore. Analysis based on a restricted diffusion model yields a nuclear pore radius of 4.5 nm, which is in good agreement with previously reported values. This application demonstrates the attractive features of two-photon photoactivation over traditional techniques, such as photobleaching, for studying transport processes in cells.  相似文献   

10.
A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.  相似文献   

11.
Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high‐quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro‐scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one‐photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two‐photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre‐optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner.  相似文献   

12.
Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z‐axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.  相似文献   

13.
It is demonstrated that fluorescence lifetimes in the nanosecond and picosecond time-scale range can be observed with the recently proposed double-pulse fluorescence lifetime imaging technique (Müller et al. , 1995, Double-pulse fluorescence lifetime imaging in confocal microscopy. J. Microsc 177, 171–179).
A laser source with an optical parametric amplifier (OPA) system is used to obtain short pulse durations needed for high time resolution, wavelength tunability for selective excitation of specific fluorophores and high pulse energies to obtain (partial) saturation of the optical transition.
It is shown that fluorescence lifetimes can be determined correctly also with nonuniform saturation conditions over the observation area.
A correction scheme for the effect on the measurements of laser power fluctuations, which are inherently present in OPA systems, is presented. Measurements on bulk solutions of Rhodamine B and Rhodamine 6G in different solvents confirm the experimental feasibility of accessing short fluorescence lifetimes with this technique.
Because signal detection does not require fast electronics, the technique can be readily used for fluorescence lifetime imaging in confocal microscopy, especially when using bilateral scanning and cooled CCD detection.  相似文献   

14.
We have studied the wavelength dependence of the two‐photon excitation efficiency for a number of common UV excitable fluorescent dyes; the nuclear stains DAPI, Hoechst and SYTOX Green, chitin‐ and cellulose‐staining dye Calcofluor White and Alexa Fluor 350, in the visible and near‐infrared wavelength range (540–800 nm). For several of the dyes, we observe a substantial increase in the fluorescence emission intensity for shorter excitation wavelengths than the 680 nm which is the shortest wavelength usually available for two‐photon microscopy. We also find that although the rate of photo‐bleaching increases at shorter wavelengths, it is still possible to acquire many images with higher fluorescence intensity. This is particularly useful for applications where the aim is to image the structure, rather than monitoring changes in emission intensity over extended periods of time. We measure the excitation spectrum when the dyes are used to stain biological specimens to get a more accurate representation of the spectrum of the dye in a cell environment as compared to solution‐based measurements.  相似文献   

15.
Multidimensional time-correlated single photon counting (TCSPC) is based on the excitation of the sample by a high-repetition rate laser and the detection of single photons of the fluorescence signal in several detection channels. Each photon is characterized by its arrival time in the laser period, its detection channel number, and several additional variables such as the coordinates of an image area, or the time from the start of the experiment. Combined with a confocal or two-photon laser scanning microscope and a pulsed laser, multidimensional TCSPC makes a fluorescence lifetime technique with multiwavelength capability, near-ideal counting efficiency, and the capability to resolve multiexponential decay functions. We show that the same technique and the same hardware can be used for precision fluorescence decay analysis and fluorescence correlation spectroscopy (FCS) in selected spots of a sample.  相似文献   

16.
A method is presented for the standardization of images acquired with fluorescence microscopy, based on the knowledge of spatial distributions proportional to the microscope's absolute excitation intensity and fluorescence detection efficiency distributions over the image field. These distributions are determined using a thin fluorescent test layer, employed under practically mono-exponential photobleaching conditions. It is demonstrated that these distributions can be used for (i) the quantitative evaluation of differences between both the excitation intensity and the fluorescence detection efficiency of different fluorescence microscopes and (ii) the standardization of images acquired with different microscopes, permitting the deduction of quantitative relationships between images obtained under different imaging conditions.  相似文献   

17.
Total internal reflection fluorescence microscopy has become a powerful tool to study the dynamics of sub-cellular structures and single molecules near substrate surfaces. However, the penetration depth of the evanescent field, that is, the distance at which the excitation intensity has exponentially decayed to 1/e, is often left undetermined. This presents a limit on the spatial information about the imaged structures. Here, we present a novel method to quantitatively characterize the illumination in total internal reflection fluorescence microscopy using tilted, fluorescently labelled, microtubules. We find that the evanescent field is well described by a single exponential function, with a penetration depth close to theoretically predicted values. The use of in vitro reconstituted microtubules as nanoscale probes results in a minimal perturbation of the evanescent field; excitation light scattering is eliminated and the refractive index of the sample environment is unchanged. The presented method has the potential to provide a generic tool for in situ calibration of the evanescent field.  相似文献   

18.
The exciplex fluorescence technique with the TMPD (tetamethyl-p-phenylene-diamine) / naphthalene dopant system was applied in a combustion-type constant-volume spray chamber. A detailed set of calibration experiments has been performed in order to quantify the TMPD fluorescence signal. It has been demonstrated that the TMPD fluorescence intensity was directly proportional to concentration, was independent of the chamber pressure, and was not sensitive to quenching by either water vapor or carbon dioxide. Using a dual heated-jet experiment, the temperature dependence of TMPD fluorescence up to 1000 K was measured. The temperature field in the spray images was determined using a simple mixing model, and an iterative solution method was used to determine the concentration and temperature field including the additional effects of the laser sheet extinction. The integrated fuel vapor concentration compared favorably with the measured amount of injected fuel when all of the liquid fuel had evaporated.  相似文献   

19.
Three-dimensional (3-D) imaging of fluorescence resonance energy transfer (FRET) in human cells under two-photon excitation was demonstrated in this study. A sample was prepared by expressing a donor and an acceptor in living cells and using an antibody to secure the proximity of contact between the donor and the acceptor. The quenching of fluorescence emission of a donor in the double-labelled cells indicates the presence of FRET that occurred in these living cells. Because of the quadratic relation of the excitation power, 3-D localisation of FRET becomes possible.  相似文献   

20.
A calibration process for planar laser induced fluorescence (PLIF) is presented and employed to investigate the mixing field of a co-flowing jet in a water channel flow. The calibration technique uses individual calibration curves for each pixel in the image array that correct for the non-uniformities of the laser sheet, optics and digital sensor and account for parameters that affect fluorescence efficiency of the dye. A unique commercial optic is introduced into the optical train to generate a thin laser sheet with an approximately uniform laser intensity distribution. The performance of the calibration procedure is investigated by analysis of the calibration data and through the investigation of a co-flowing jet. The results compare well with the results documented in the literature for this flow field. The work shows that the simple approach designed specifically for application in large-scale facilities is suitable for calibration of PLIF style techniques.  相似文献   