首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
We are developing an experiment to measure the correlations a, A, and B, and the Fierz interference term b in neutron decay, with a precision of approximately 10−4. The experiment uses an electromagnetic spectrometer in combination with two large-area segmented silicon detectors to detect the proton and electron from the decay in coincidence, with 4π acceptance for both particles. For the neutron-polarization-dependent observables A and B, precision neutron polarimetry is achieved through the combination of a pulsed neutron beam, under construction at the SNS, and a polarized 3He neutron polarizer. Measuring a and A in the same apparatus provides a redundant determination of λ = gA/gV. Uncertainty in λ dominates the uncertainty of CKM unitarity tests.  相似文献   

2.
We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a 3He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible.  相似文献   

3.
We are going to use a polarized cold neutron beam and an axial magnetic field in the shape of a bottle formed by a superconducting magnetic system. Such a configuration of magnetic fields allows us to extract the decay electrons inside a well-defined solid angle with high accuracy. An electrostatic cylinder with a potential of 25 kV defines the detected region of neutron decays. The protons, which come from this region will be accelerated and registered by a proton detector. The use of coincidences between electron and proton signals will allow us to considerably suppress the background. The final accuracy of the A-asymmetry will be determined by the uncertainty of the neutron beam polarization measurement which is at the level of (1–2) × 10−3, as shown in previous studies.  相似文献   

4.
The abBA collaboration proposes to conduct a comprehensive program of precise measurements of neutron β-decay coefficients a (the correlation between the neutrino momentum and the decay electron momentum), b (the electron energy spectral distortion term), A (the correlation between the neutron spin and the decay electron momentum), and B (the correlation between the neutron spin and the decay neutrino momentum) at a cold neutron beam facility. We have used a GEANT4-based code to simulate the propagation of decay electrons and protons in the electromagnetic spectrometer and study the energy and timing response of a pair of Silicon detectors. We used these results to examine systematic effects and find the uncertainties with which the physics parameters a, b, A, and B can be extracted from an over-determined experimental data set.  相似文献   

5.
An experiment aiming at the simultaneous determination of both transversal polarization components of electrons emitted in the decay of free neutrons begins data taking using the polarized cold neutron beam (FUNSPIN) from the Swiss Neutron Spallation Source (SINQ) at the Paul-Scherrer Institute, Villigen. A non-zero value of R due to the e polarization component, which is perpendicular to the plane spanned by the spin of the decaying neutron and the electron momentum, would signal a violation of time reversal symmetry and thus physics beyond the Standard Model. Present status of the project and the results from analysis of the first data sample will be discussed.  相似文献   

6.
A new type of per-fluorinated polymer, “Low Temperature Fomblin,” has been tested as a wall coating in an ultracold neutron (UCN) storage experiment using a gravitational storage system. The data show a UCN reflection loss coefficient η as low as ≈ 5 × 10−6 in the temperature range 105 K to 150 K. We plan to use this oil in a new type of neutron lifetime measurement, where a bellows system (“accordion”) enables to vary the trap size in a wide range while the total surface area and distribution of surface area over height remain constant. These unique characteristics, in combination with application of the scaling technique developed by W. Mampe et al. in 1989, ensure exact linearity for the extrapolation from inverse storage lifetimes to the inverse neutron lifetime. Linearity holds for any energy dependence of loss coefficient µ(E). Using the UCN source at the Institut Laue Langevin we expect to achieve a lifetime precision below ±1 s.  相似文献   

7.
The neutron coherent scattering length bc has been determined interferometrically to an uncertainty of about 5 × 10−5 by measuring the nondispersive phase. We propose improving the uncertainty to about 10−6 by optimizing various parameters of the interferometric experiment. Any uncertainty in the bc determination arising from possible variations in the constitution of the ambient air can be eliminated by performing the experiment in vacuum. When such uncertainty is attained, it becomes necessary to account for the neutron beam refraction at the sample-ambient interfaces, to infer the correct bc from the observed phase. The formula for the phase used hitherto is approximate and would significantly overestimate bc. The refractive index for neutrons can thus be determined to a phenomenal uncertainty of about 10−12.  相似文献   

8.
We measured the neutron decay lifetime by counting in-beam neutron decay recoil protons trapped in a quasi-Penning trap. The absolute neutron beam fluence was measured by capture in a thin 6LiF foil detector with known efficiency. The combination of these measurements gives the neutron lifetime: τn = (886.8 ± 1.2 ± 3.2) s, where the first (second) uncertainty is statistical (systematic) in nature. This is the most precise neutron lifetime determination to date using an in-beam method.  相似文献   

9.
Currently, the beta-neutrino asymmetry has the largest uncertainty (4 %) of the neutron decay angular correlations. Without requiring polarimetry this decay parameter can be used to measure λ (ga/gv), test Cabibbo-Kobayashi-Maskawa (CKM) unitarity limit scalar and tensor currents, and search for Charged Vector Current (CVC) violation. We propose to measure the beta-neutrino asymmetry coeffcient, a, using time-of-flight for the recoil protons. We hope to achieve a systematic uncertainty of σa / a ≈ 1.0 %. After tests at Indiana University’s Low Energy Neutron Source (LENS), the apparatus will be moved to the National Institute of Standards and Technology (NIST) where the measurement can achieve a statistical uncertainty of 1 % to 2 % in about 200 beam days.  相似文献   

10.
We present a conceptual design for an experiment to measure the neutron lifetime (~886 s) with an accuracy of 10−4. The lifetime will be measured by observing the decay rate of a sample of ultracold neutrons (UCN) confined in vacuum in a magnetic trap. The UCN collaboration at Los Alamos National Laboratory has developed a prototype UCN source that is expected to produce a bottled UCN density of more than 100/cm3 [1]. The availability of such an intense source makes it possible to approach the measurement of the neutron lifetime in a new way. We argue below that it is possible to measure the neutron lifetime to 10−4 in a vacuum magnetic trap. The measurement involves no new technology beyond the expected UCN density. If even higher densities are available, the experiment can be made better and/or less expensive. We present the design and methodology for the measurement. The slow loss of neutrons that have stable orbits, but are not energetically trapped would produce a systematic uncertainty in the measurement. We discuss a new approach, chaotic cleaning, to the elimination of quasi-neutrons from the trap by breaking the rotational symmetry of the quadrupole trap. The neutron orbits take on a chaotic character and mode mixing causes the neutrons on the quasi-bound orbits to leave the trap.  相似文献   

11.
By means of neutron interferometry the s-wave neutron scattering length of the 3He nucleus was re-measured at the Institut Laue-Langevin (ILL). Using a skew symmetrical perfect crystal Si-interferometer and a linear twin chamber cell, false phase shifts due to sample misalignment were reduced to a negligible level. Simulation calculations suggest an asymmetrically alternating measuring sequence in order to compensate for systematic errors caused by thermal phase drifts. There is evidence in the experiment’s data that this procedure is indeed effective. The neutron refractive index in terms of Sears’ exact expression for the scattering amplitude has been analyzed in order to evaluate the measured phase shifts. The result of our measurement, b′c = (6.000 ± 0.009) fm, shows a deviation towards a greater value compared to the presently accepted value of b′c = (5.74 ± 0.07) fm, confirming the observation of the partner experiment at NIST. On the other hand, the results of both precision measurements at NIST and ILL exhibit a serious 12σ (12 standard uncertainties) deviation, the reason for which is not clear yet.  相似文献   

12.
We present a new value for the neutron lifetime of 878.5 ± 0.7stat. ± 0.3syst. This result differs from the world average value by 6.5 standard deviations and by 5.6 standard deviations from the previous most precise result. However, this new value for the neutron lifetime together with a β-asymmetry in neutron decay, A0, of −0.1189(7) is in a good agreement with the Standard Model.  相似文献   

13.
Polarized 3He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of 3He spin filters for slow neutron physics. Besides the essential goal of maximizing the 3He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize 3He, but will focus on SE. We will discuss the recent demonstration of 75 % 3He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping.  相似文献   

14.
We are developing a high-efficiency neutron detector with 1 cm position resolution and coarse energy resolution for use at high-flux neutron source facilities currently proposed or under construction. The detector concept integrates a segmented 3He ionization chamber with the position sensitive, charged particle collection methods of a MicroMegas detector. Neutron absorption on the helium produces protons and tritons that ionize the fill gas. The charge is amplified in the field region around a wire mesh and subsequently detected in current mode by wire strips mounted on a substrate. One module consisting of a high-voltage plate, a field-shaping high-voltage plate, a grid and wire strips defines a detection region. For 100 % efficiency, detector modules are consecutively placed along the beam axis. Analysis over several regions with alternating wire strip orientation provides a two-dimensional beam profile. By using 3He, a 1/v absorption gas, each axial region captures neutrons of a different energy range, providing an energy-sensitive detection scheme especially useful at continuous beam sources.  相似文献   

15.
The NPDGamma γ-ray detector has been built to measure, with high accuracy, the size of the small parity-violating asymmetry in the angular distribution of gamma rays from the capture of polarized cold neutrons by protons. The high cold neutron flux at the Los Alamos Neutron Scattering Center (LANSCE) spallation neutron source and control of systematic errors require the use of current mode detection with vacuum photodiodes and low-noise solid-state preamplifiers. We show that the detector array operates at counting statistics and that the asymmetries due to B4C and 27Al are zero to with- in 2 × 10−6 and 7 × 10−7, respectively. Boron and aluminum are used throughout the experiment. The results presented here are preliminary.  相似文献   

16.
Two infrared absorption bands of CH2D2 have been analyzed in the semirigid rotor approximation. These are the A-type band at 2671.67 cm−1 and the C-type band at 4425.61 cm−1. The A-type band has previously been assigned as v3+v9, and the C-type band is tentatively assigned as v3+v6 The upper state of the A-type band is perturbed presumably by the close lying level 2v5. This interaction has not been investigated. The following values were found for the rotational constants of the ground vibrational state: A0=4.303 cm−1, B0= 3.504 cm−1, C0= 3.049 cm−1.  相似文献   

17.
We report progress on an experiment to measure the neutron lifetime using magnetically trapped neutrons. Neutrons are loaded into a 1.1 T deep superconducting Ioffe-type trap by scattering 0.89 nm neutrons in isotopically pure superfluid 4He. Neutron decays are detected in real time using the scintillation light produced in the helium by the beta-decay electrons. The measured trap lifetime at a helium temperature of 300 mK and with no ameliorative magnetic ramping is substantially shorter than the free neutron lifetime. This is attributed to the presence of neutrons with energies higher than the magnetic potential of the trap. Magnetic field ramping is implemented to eliminate these neutrons, resulting in an 83363+74s trap lifetime, consistent with the currently accepted value of the free neutron lifetime.  相似文献   

18.
First, the nucleosynthesis in the universe was reviewed. In particular, the neutron capture nucleosyntheses in the Big-Bang and the s- and r-processes were reviewed in detail. It was pointed out that keV-neutron capture cross sections were important for the study on the neutron capture nucleosynthesis. Second, our measurement of keV-neutron capture cross sections was explained briefly, and the results on 7Li, 12C, and 16O were shown and compared with previous experimental values and the predicted values from the 1/v law and the thermal neutron capture cross sections. The results at 30 keV on 12C and 16O were much larger than the 1/v predictions, while the result at 30 keV on 7Li was in good agreement with the 1/v prediction. The large values for 12C and 16O were ascribed to the non-resonant p-wave neutron capture from the analysis of observed capture γ-ray spectra and the neutron energy dependence of derived partial capture cross sections. As for 7Li, the good agreement was ascribed to the peculiarity of bound states of its residual nucleus, which strongly suppresses the non-resonant p-wave neutron capture. Finally, it was shown that the non-resonant p-wave neutron capture is predominant in the neutron capture nucleosynthesis of light nuclei in the universe.  相似文献   

19.
The coefficient a0 has been derived from a measurement of the integral spectrum of recoil protons stored in a quasi-Penning trap with inhomogeneous magnetic field and adiabatic focusing onto an electro-static mirror of potential variable in 10 V steps between 0 V and 850 V. Correction for incomplete transfer of energy from transverse to longitudinal degrees of freedom, and the violation of the adiabatic conditions on reflection at the mirror, is carried out by alternately measuring the spectrum at trapping times of 1 ms and 2 ms. The results a0 = −0.1054 ± 0.0055 and |λ | = 1.271 ± 0.018 are comparable in precision with existing measurements of a0.  相似文献   

20.
The Peking University Neutron Imaging Facility (PKUNIFTY) is a Radio Frequency Quadruple (RFQ) accelerator based system. The fast neutrons are produced by 2 MeV deuterons bombarding beryllium target. The moderator, reflector, shielding and collimator have been optimized with Monte-Carlo simulation to improve the neutron beam quality. The neutrons are thermalized in water cylinder of Φ26×26 cm2 with a polyethylene disk in front of Be target. The size of deuteron beam spot is optimized considering both the thermal neutron distribution and the demand of target cooling. The shielding is a combination of 8 cm thick lead and 42 cm thick boron doped polyethylene. The thermal neutrons are extracted through a rectangular inner collimator and a divergent outer collimator. The thermal neutron beam axis is perpendicular to the D+ beam line in order to reduce the fast neutron and the γ ray components in the imaging beam. When the neutron yield is 3×1012 n/s and the L/D is 50, the thermal neutron flux is 5×105 n/cm2/s at the imaging plane, the Cd ratio is 1.63 and the n/γ ratio is 1.6×1010 n/cm2/Sv.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号