共查询到10条相似文献,搜索用时 93 毫秒
1.
单开关Buck-Flyback功率因数校正变换器 总被引:1,自引:0,他引:1
针对传统Buck功率因数校正(power factor correction,PFC)变换器输入电流谐波分量高的问题,提出一种单开关Buck-Flyback PFC变换器。它由Buck PFC变换器与Flyback PFC变换器的输入和输出分别并联并合并主开关管而构成。当输入电压低于输出电压时,变换器工作于Flyback模式,消除了传统Buck PFC变换器的输入电流死区,进而降低了输入电流谐波。分析工作在断续模式的单开关Buck-Flyback PFC变换器的输入电流特性,理论分析表明,该变换器可在全电压输入范围内获得高功率因数与低总谐波失真率,满足IEC 61000-3-2 C类法规对输入电流各次谐波的要求。最后,通过一台96 W实验样机验证理论分析的正确性。 相似文献
2.
In this study, a voltage superposition concept is used without phase adjustment of the input current command and without enlarging the turn-on period of the switch in the vicinity of the zero input voltage, but only with a few components added to the PFC converter, so as to improve the zero-crossing distortion of the input current, thereby further reducing the total harmonic distortion. Eventually, the mathematical deductions and experimental results are provided to verify the effectiveness of the proposed circuit. 相似文献
3.
双电压合成矩阵变换器换流策略的改进 总被引:1,自引:0,他引:1
换流问题是矩阵变换器工业应用的主要障碍之一.基于双电压合成策略,分析了传统的四步换流策略由于换流时刻存在延迟,降低了换流可靠性,并且会导致输入和输出波形发生畸变.根据四步换流策略的原理,将四步换流缩短为两步换流,大大减少了换流时间.利用Matlab/Simulink软件建立了相应的仿真模型,并利用dSPACE硬件实时仿真平台进行了实验.仿真和实验结果表明,两步换流策略提高了换流可靠性,改善了输入输出波形质量,其输出电流THD值(总谐波畸变率)由4.68%降为2.67%. 相似文献
4.
分析了功率因数校正(power factor correction,PFC)变换器输入电流过零畸变产生的原因,指出电网频率、电感电流滞后角及电感大小都将对输入电流过零畸变产生影响,并通过仿真验证了分析结果。将交错技术可以在等效减小电感量的同时减小电感电流纹波这一特性应用于Boost PFC电路,提出一种利用交错并联技术解决单相PFC变换器输入电流过零畸变的方法。通过仿真验证了该方法的有效性。 相似文献
5.
在分析单相统一电能质量控制器(unified power quality conditioner,UPQC)瞬时功率平衡关系的基础上,提出一种基于自适应滤波电流检测的UPQC双电流源协调控制策略。鉴于电流检测精度对双电流源控制策略补偿性能的影响,在保留变步长自适应算法快速性的前提下,提出一种提高电流检测精度的定频率滤波器改进算法。针对双电流源UPQC的控制器设计,采用比例控制和重复控制构成复合控制实现了串、并联有源电力滤波器的电流跟踪控制;从UPQC整体出发建立直流电压闭环控制的小信号模型,为直流电压环的控制器参数设计提供理论指导。研究结果表明,基于该控制策略和控制器设计方案的UPQC系统实现了较好的负载电压和电网电流补偿效果。 相似文献
6.
Mathematical modelling for power DC/DC converters is a historical problem accompanying DC/DC conversion technology since 1940‘s. The traditional mathematical modelling is not available for complex structure converters since the differential equation order increases very high. We have to search other way to establish mathematical modelling for power DC/DC converters. We have theoretically defined a new concept - Energy Factor (EF) in this paper and researched the relations between EF and the mathematical modelling for power DC/DC converters. EF is a new concept in power DC/DC conversion technology, which thoroughly differs from the traditional concepts such as power factor (PF), power transfer efficiency (η), total harmonic distortion (THD) and ripple factor (RF). EF and the subsequential EFV (and EFVD ) can illustrate the system stability, reference response and interference recovery. This investigation is very helpful for system design and DC/DC converters characteristics foreseeing. Two DC/DC converters: Buck converter and Super-Lift Luo-Converter.as the samples are analysed in this paper to demonstrate the applications of EF, EFV (and EFVD ), PE,SE, VE (and VED ), time constant τ and damping time constant τd. 相似文献
7.
基于FBD法的基波正负序电流实时检测方法 总被引:1,自引:0,他引:1
为了快速、有效地检测电气化铁道供电系统中的基波正、负序电流和高次谐波电流,文中提出了一种基于FBD(Fryze-Buchholz-Dpenbrock)法的电流实时检测方法。利用锁相环跟踪三相不对称或畸变电压的某一相,获取其频率和相位信息,以此构造基波正序参考电压和基波负序参考电压;利用构造的正、负序参考电压和检测出的三相电流求得对应的正、负序等效电导;对电导进行低通滤波器滤波,获取其正、负序直流分量;将电导的正、负序直流分量乘以相应的正、负序参考电压,即可获得基波正、负序电流;从总电流中减去基波正、负序电流即得到谐波电流。由于该方法只需要检测系统三相电压中一相的基波频率和相位,因此可应用于系统电压不对称或畸变的情况。该方法无需Park变换和dq变换,计算量较小。仿真结果证实了该方法的正确性和有效性。 相似文献
8.
能量因数及功率直流变换器建模 总被引:1,自引:0,他引:1
直流变换器的数学模型是自20世纪40年代以来伴随直流变换科技发展的历史性问题.传统数学模型成功描述了基础变换器,但无效于高阶复杂结构变换器.研究新方法对直流变换器建模势在必行. 相似文献