首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
The performances of three types of heat exchangers that use the louver fin geometry: (1) parallel flow parallel fin with extruded flat tubes heat exchanger (PF2), (2) parallel flow serpentine fin with extruded flat tubes heat exchanger (PFSF) and (3) round tube wave plate fin heat exchanger (RTPF) have been experimentally studied under dry, wet and frost conditions and results are presented. The parameters quantified include air-side pressure drop, water retention on the surface of the heat exchanger, capacity and overall heat transfer coefficient for air face velocity 0.9, 2 and 3 m/s, air humidity 70% and 80% and different orientations. The performances of three types of heat exchanger are compared and the results obtained are presented. The condensate drainage behavior of the air-side surface of these three heat exchanger types was studied using both the dip testing method and wind tunnel experiment.  相似文献   

2.
空调用翅片管式换热器长期使用会受到一定程度的腐蚀,影响换热器的换热性能,导致整个空调系统的能效降低.本文介绍了翅片管式换热器3种主要的腐蚀机理:蚁巢腐蚀、点蚀和间隙腐蚀,从形貌、压降及传热特性3个方面分析了腐蚀对翅片管式换热器性能的影响,结果表明:翅片管式换热器腐蚀后,传热系数和换热量均减小,空气侧压降受影响较小,在5...  相似文献   

3.
In most domestic and commercial refrigeration systems, frost forms on the air-side surface of the air-to-refrigerant heat exchanger. Frost-tolerant designs typically employ a large fin spacing in order to delay the need for a defrost cycle. Unfortunately, this approach does not allow for a very high air-side heat transfer coefficient, and the performance of these heat exchangers is often air-side limited. Longitudinal vortex generation is a proven and effective technique for thinning the thermal boundary layer and enhancing heat transfer, but its efficacy in a frosting environment is essentially unknown. In this study, an array of delta-wing vortex generators is applied to a plain-fin-and-tube heat exchanger with a fin spacing of 8.5 mm. Heat transfer and pressure drop performance are measured to determine the effectiveness of the vortex generator under frosting conditions. For air-side Reynolds numbers between 500 and 1300, the air-side thermal resistance is reduced by 35–42% when vortex generation is used. Correspondingly, the heat transfer coefficient is observed to range from 33 to 53 W m−2 K−1 for the enhanced heat exchanger and from 18 to 26 W m−2 K−1 for the baseline heat exchanger.  相似文献   

4.
Improving the performance of the pulse tube cooler is one of the important objectives of the current studies. Besides the phase shifters and regenerators, heat exchangers also play an important role in determining the system efficiency and cooling capacity. A series of experiments on a 10 W @ 77 K class co-axial type pulse tube cooler with different cold heat exchanger geometries are presented in this paper. The cold heat exchangers are made from a copper block with radial slots, cut through using electrical discharge machining. Different slot widths varying from 0.12 mm to 0.4 mm and different slot numbers varying from around 20–60 are investigated, while the length of cold heat exchangers are kept the same. The cold heat exchanger geometry is classified into three groups, namely, constant heat transfer area, constant porosity and constant slot width. The study reveals that a large channel width of 0.4 mm (about ten times the thermal penetration depth of helium gas at 77 K, 100 Hz and 3.5 MPa) shows poor performance, the other results show complicated interaction effects between slot width and slot number. These systematic comparison experiments provide a useful reference for selecting a cold heat exchanger geometry in a practical cooler.  相似文献   

5.
An experimental study on the air-side heat transfer and pressure drop characteristics for multi-louvered fin and flat tube heat exchangers has been performed. For 45 heat exchangers with different louver angles (15–29°), fin pitches (1.0, 1.2, 1.4 mm) and flow depths (16, 20, 24 mm), a series of tests were conducted for the air-side Reynolds numbers of 100–600, at a constant tube-side water flow rate of 0.32 m3/h. The inlet temperatures of the air and water for heat exchangers were 21 and 45°C, respectively. The air-side thermal performance data were analyzed using effectiveness-NTU method for cross-flow heat exchanger with both fluid unmixed conditions. The heat transfer coefficient and pressure drop data for heat exchangers with different geometrical configurations were reported in terms of Colburn j-factor and Fanning friction factor f, as functions of Reynolds number based on louver pitch. The general correlations for j and f factors are developed and compared to other correlations. The f correlation indicates that the flow depth is one of the important parameters for the pressure drop.  相似文献   

6.
管翅式换热器的翅片优化为研究热点,而对管型的研究较少.本文提出一种与圆管相同水力半径的异型管的设计方法,建立了异型管管翅式换热器空气侧换热的数值计算模型,研究了管型、迎风方向和翅片间距对异型管管翅式换热器性能的影响.结果表明:对于双排的异型管换热器,第一排管大圆迎风,第二排管小圆迎风时,空气流动最均匀,压降最低,是综合...  相似文献   

7.
The potential of winglet type vortex generator (VG) arrays for air-side heat transfer enhancement is experimentally evaluated by full-scale wind-tunnel testing of a compact plain-fin-and-tube heat exchanger. The effectiveness of a 3VG alternate-tube inline array of vortex generators is compared to a single-row vortex generator design and the baseline configuration. The winglets are placed in a common-flow-up orientation for improved tube wake management. The overall heat transfer and pressure drop performance are assessed under dry-surface conditions over a Reynolds number range based on hydraulic diameter of 220 ≤ Re ≤ 960. It is found that the air-side heat transfer coefficient increases from 16.5% to 44% for the single-row winglet arrangement with an increase in pressure drop of less than 12%. For the three-row vortex generator array, the enhancement in heat transfer coefficient increases with Reynolds number from 29.9% to 68.8% with a pressure drop penalty from 26% at Re = 960 to 87.5% at Re = 220. The results indicate that vortex generator arrays can significantly enhance the performance of fin-tube heat exchangers with flow depths and fin densities typical to those used in air-cooling and refrigeration applications.  相似文献   

8.
Chao Wang 《低温学》2008,48(3-4):154-159
This paper introduces intermediate cooling by thermally attaching heat exchangers on the second stage pulse tube and regenerator in a commercial 4 K pulse tube cryocooler. Due to the large enthalpy flow in the 2nd stage pulse tube and regenerator, both intermediate heat exchangers on the pulse tube and regenerator can provide cooling capacities in the temperature range of 5–15 K without or with minor effect on the performance of the 4 K stage. Extracting cooling capacity from the pulse tube or regenerator reduces the 1st stage cooling performance in the present study. The joint intermediate heat exchanger on the pulse tube and regenerator has demonstrated promising results for applications.  相似文献   

9.
The objective of this study is to provide experimental data that can be used in the optimal design of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch decreased from 15.0 to 7.5 mm over the Reynolds number range of 500–900 that was calculated based on the tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finned-tubes with large fin pitch. The correlation yielded good predictions of the measured data with mean deviations of 3.8 and 6.2% for the inline and staggered tube alignment, respectively.  相似文献   

10.
小管径椭圆管开缝翅片换热器的数值模拟   总被引:1,自引:0,他引:1  
对小管径椭圆管开缝翅片换热器空气侧的流动与传热特性进行数值模拟,对影响其换热性能的2个主要参数椭圆管偏心率和开缝翅片开缝错列高度分布进行优化,与传统管翅式换热器换热性能进行比较。模拟结果表明:当椭圆管两轴之比Rx:Ry=2:3(偏心率),开缝高度分布为0.8 mm,0.6 mm和0.4 mm时,换热效果最好。与传统管翅式换热器相比,小管径椭圆管开缝翅片换热器换热系数提高10%~20%,而压降几乎相等,总体换热性能提高。  相似文献   

11.
Condensation heat transfer characteristics of R134a on the integral-fin tubes are experimentally investigated. The test tubes are made of stainless steel, and the root diameter of the tubes is 13.27 mm. The height of fin is 1.19 mm, and the densities of the integral fin are 19 fpi and 26 fpi. The present tests were conducted at the saturation temperatures of 20 °C and 30 °C. The condensation heat transfer coefficients of the tubes having 19 fpi and 26 fpi at the saturation temperature of 20 °C are higher than that of the plain tube by 4.4 and 3.1 times, respectively. When the temperature difference across the condensate film is less than 0.7 °C, the enhancement of the tube of 19 fpi is much larger than that of the tube of 26 fpi. The Honda and Nozu model shows the smallest mean deviation between the estimated values and experimental results among the existing models.  相似文献   

12.
An experimental study for air-side thermal-hydraulic performance of brazed aluminum heat exchangers under dehumidifying conditions has been performed. For 30 samples of louvered fin heat exchangers with different geometrical parameters, the heat transfer and pressure drop characteristics for wet surface were evaluated. The test was conducted for air-side Reynolds number in the range of 80–300 and tube-side water flow rate of 320 kg/h. The dry- and wet-bulb temperatures of the inlet air for heat exchangers were 27 and 19 °C, respectively and the inlet water temperature was 6 °C. The air-side thermal performance data for cooling and dehumidifying conditions were analyzed using effectiveness-NTU method for cross-flow heat exchanger with both fluids unmixed. The test results are reported, compared with those for the dry surface heat exchangers, in terms of sensible j factor and friction factor f, as functions of Reynolds number based on louver pitch. The correlations for j and f factors are developed within rms errors of ±16.9 and ±13.6%, respectively.  相似文献   

13.
Slush fluids such as slush hydrogen and slush nitrogen are characterized by superior properties as functional thermal fluids due to their density and heat of fusion. In addition to allowing efficient hydrogen transport and storage, slush hydrogen can serve as a refrigerant for high-temperature superconducting (HTS) equipment using MgB2, with the potential for synergistic effects. In this study, pressure drop reduction and heat transfer deterioration experiments were performed on slush nitrogen flowing in a horizontal triangular pipe with sides of 20 mm under the conditions of three different cross-sectional orientations. Experimental conditions consisted of flow velocity (0.3–4.2 m/s), solid fraction (0–25 wt.%), and heat flux (0, 10, and 20 kW/m2). Pressure drop reduction became apparent at flow velocities exceeding about 1.3–1.8 m/s, representing a maximum amount of reduction of 16–19% in comparison with liquid nitrogen, regardless of heating. Heat transfer deterioration was seen at flow velocities of over 1.2–1.8 m/s, for a maximum amount of deterioration of 13–16%. The authors of the current study compared the results for pressure drop reduction and heat transfer deterioration in triangular pipe with those obtained previously for circular and square pipes, clarifying differences in flow and heat transfer properties. Also, a correlation equation was obtained between the slush Reynolds number and the pipe friction factor, which is important in the estimation of pressure drop in unheated triangular pipe. Furthermore, a second correlation equation was derived between the modified slush Reynolds number and the pipe friction factor, enabling the integrated prediction of pressure drop in both unheated triangular and circular pipes.  相似文献   

14.
This paper presents the air-side pressure drop and overall heat transfer coefficient characteristics for serpentine-louvered-fin, microchannel heat exchanger in periodic frosting. It focuses on quantification of the effects of louver angle on heat transfer and pressure drop and on defrost and refrost times. Nine heat exchangers differing in louver angle and fin pitch (i.e. louver angle 15° to 39° and fin pitch 12 to 18 fpi) are studied. The face velocity was 3.5 m s−1 and inlet air relative humidity of 70% and 80%.The major finding of this paper is seen in the proof that it is necessary to perform experiments in several consecutive cycles to be able to understand the situation in operation of the heat exchangers and that geometry that is the best in first frosting test does not stay the best in real operation where multiple consecutive frosting occurs.  相似文献   

15.
This study examined the two-phase flow boiling pressure drop and heat transfer for propane, as a long term alternative refrigerant, in horizontal minichannels. The pressure drop and local heat transfer coefficients were obtained for heat fluxes ranging from 5–20 kW m?2, mass fluxes ranging from 50–400 kg m?2 s?1, saturation temperatures of 10, 5 and 0 °C, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 1.5 mm and 3.0 mm, and lengths of 1000 mm and 2000 mm, respectively. The present study showed the effect of mass flux, heat flux, inner tube diameter and saturation temperature on pressure drop and heat transfer coefficient. The experimental results were compared against several existing pressure drop and heat transfer coefficient prediction methods. Because the study on evaporation with propane in minichannels was limited, new correlations of pressure drop and boiling heat transfer coefficient were developed in this present study.  相似文献   

16.
单一金属高螺纹翅片管换热器的探索与实践   总被引:1,自引:0,他引:1  
通过对管壳式换热器几种常见翅片管的结构特点、换热性能和制造经济性进行分析比较和研究,研制出传热效率更高、结构更紧凑、制造成本更低廉的新型换热元件——单一金属轧制的高螺纹翅片管;提出了传热学意义上最佳翅片截面轮廓线的通用解析式。通过生产实践与不断改进,形成了一组高螺纹翅片管系列产品,并成功地应用于为透平压缩机配套的大中型管壳式换热器。  相似文献   

17.
In this paper, a validated numerical model for frost growth on heat exchange fins is modified to simulate a fan-supplied finned heat exchanger under refrigeration frosting conditions. It is found that frost growth on refrigeration heat exchangers causes a dramatic drop in the fin heat rate, airflow rate, and fin efficiency while the pressure drop increases. A sensitivity study shows the effects of changing several design parameters including the type of fan.  相似文献   

18.
采用CFD数值模拟的方法,对整体翅片式微通道换热器空气侧的流动与传热特性进行研究,用场协同的原理分析翅片参数(长度、高度、间距)对换热器性能的影响,并与传统微通道换热器空气侧性能进行对比。结果表明:在考查的翅片尺寸范围内,随着翅片长度的缩短、高度的增加、间距的减小,温度场和速度场的协同性随之改善,有利于换热效果的提高;与传统的微通道换热器相比,整体翅片式微通道换热器空气侧换热性能变差,但是阻力大大降低,总体性能有所改善。  相似文献   

19.
三排变片距翅片盘管换热器结霜特性实验研究   总被引:1,自引:0,他引:1       下载免费PDF全文
为改善空气源热泵室外翅片盘管换热器在低环境温度下沿空气流动方向结霜不均匀、首排结霜量较大进而导致热泵除霜间隔较短、制热能力下降等问题,对不同翅片片距组合的变片距翅片盘管换热器在低环温工况下运行及结霜的情况进行实验研究。结果表明:变片距翅片盘管换热器在低环温条件下可有效延长迎风面管排发生结霜堵塞的时间、对于结霜生长速度和结霜质量也有抑制作用。变片距翅片盘管换热器在结霜中后期阶段换热功率更高,在合理的翅片间距组合下,变片距翅片盘管换热器可以在不损失过多换热功率的情况下延长换热器迎风面管排结霜堵塞的时间,如样品4的平均换热功率比样品1低6.02%,而除霜间隔延长了37 min。  相似文献   

20.
Erosion in the tube entrance region of a typical air-cooled heat exchanger is numerically predicted. The erosion rates are obtained for different flow rates and particle sizes assuming low particle concentration. The erosion prediction is based on using a mathematical model for simulating the fluid velocity field and another model for simulating the motion of solid particles. The fluid velocity model is based on the solution of the time-averaged governing equations of 3-D turbulent flow while the particle-tracking model is based on the solution of the governing equation of each particle motion taking into consideration the viscous and gravity forces as well as the effect of particle rebound behavior. The computational model was validated against available experimental data and the comparison resulted in a good agreement. The investigation covered particle sizes from 10 to 350 μm and inlet flow velocities from 0.18 to 4.5 m/s. The results show that the location and number of eroded tubes depend mainly on the particle size and flow velocity at the header inlet. The total rate of erosion was found to increase exponentially with flow velocity. At high flow velocities, the maximum total erosion rate results from large particles and the effect is reversed at low velocities. Similarly, the tube penetration rate was found to increase with the increase of flow velocity for all particle sizes. At the typical velocity of 1.1 m/s, the minimum tube lifetime was caused by the 350 μm particles and the maximum was caused by the 200 μm particles. Based on the obtained results, it is well established that erosion cannot be totally avoided so long as solid particles are present in the fluid. However, the threshold velocity below which erosion is negligible can be accurately defined if an acceptable lifetime (or penetration rate) is defined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号