首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Allergen exposure is a risk to develop an IgE-mediated sensitization. The amount of allergen inhaled per unit time should be related to the amount present in the air, i.e. airborne allergen. Thus, measuring allergen levels in the air would be more relevant than measuring allergen levels in dust. Allergens are present in the air in very minute quantities and usually become airborne after disturbance. Large variation of allergen levels have been found in dust. In this study, we measured variability of airborne cat allergen, Fel d1, in a public place using a high-volume air-sampler. We also studied the distribution and relationship between dust and airborne cat allergens in homes and schools. Air samples were collected at three different airflow rates, i.e. 55, 40, and 30 m3 of air per hour. The concentration of airborne Fel d1 in the community gymnastic hall varied from 1 to 10 pg/m3 within a period of 3 weeks, at airflow rates 55-30 m3/h. The coefficient of variation for repeated samplings was 14-43% (day-to-day variation) and 27-38% (within-day variation). As expected, higher levels of airborne cat allergens were found in homes with cats than in cat-free environments. There was a significant relationship between cat allergen levels in dust and air (r=0.7, P<0.01). Our study demonstrates that when measuring airborne cat allergen a large variation is observed within a day and between days. The large variability of measurement may be explained by the disturbance in the environments. We suggest, that when exposure assessment is made the environment in question should be analyzed, if possible in several occasions.  相似文献   

2.
The aim was to study asthma and allergy in relation to diet and the school environment. Pupils (5-14 years) in eight schools received a questionnaire, 1014 participated (68%). Settled dust was collected on ALK-filters and analyzed for allergens from cat (Fel d 1), dog (Can f 1), horse (Equ cx), house dust mites (Der p 1, Der f 1), and cockroach (Bla g 1) by ELISA. In total, 6.8% reported cat allergy, 4.8% dog allergy, 7.7% doctor's diagnosed asthma and 5.9% current asthma, and 7.8% reported wheeze. Current asthma was less common among those consuming more fresh milk (P < 0.05) and fish (P < 0.01). Poly-unsaturated fatty acids was associated with more wheeze (P < 0.05), olive oil was associated with less doctors' diagnosed asthma (P < 0.05). Totally, 74% of the classrooms had mean CO(2) <1000 ppm. The median concentration per gram dust was 860 ng/g Fel d 1, 750 ng/g Can f 1 and 954 U/g Equ cx. Horse allergen was associated with more wheeze (P < 0.05), daytime breathlessness (P < 0.05), current asthma (P < 0.05) and atopic sensitization (P < 0.05). Dog allergen was associated with wheeze (P < 0.05) and daytime breathlessness (P < 0.05). The associations between allergens and respiratory symptoms were more pronounced among those consuming margarine, not consuming butter, and with a low intake of milk. In conclusion, cat, dog and horse allergens in schools could be a risk factor for asthma and atopic sensitization, and dietary factors may interact with the allergen exposure. PRACTICAL IMPLICATIONS: Previous school studies performed by us in mid-Sweden, showed that most classrooms did not fulfill the ventilation standards. In this study, most of the classrooms fulfilled the ventilation standard, but despite that had widespread allergen contamination. Most previous studies have focused on cat allergen, but our study has shown that also dog and horse allergens can be risk factors for asthma and allergy in schools. As allergens are transported from other environments, mainly the home environment, the main prevention should be to minimize transfer of allergens. This could be achieved by reducing contacts with furry pets and horses, or using different clothes at home and at school (e.g. school uniforms). Increased cleaning in the schools may reduce allergen levels, but the efficiency of this measure must be evaluated in further intervention studies. Finally, our study supports the view that dietary habits among pupils should not be neglected and interaction between dietary factors and indoor allergen exposure needs to be further investigated.  相似文献   

3.
BACKGROUND: Exposure to indoor allergens has already been shown to occur in many public places, including workplaces, in several countries. Aim of this study was to measure the levels of house dust mites, cat and cockroach allergens in indoor workplaces (offices and archives) in Italy and to evaluate the possible relationships between allergen levels and building characteristics, type of ventilation, indoor relative humidity and temperature. METHODS: Der f 1 and Der p 1, Fel d 1, Bla g 2 were measured by ELISA in dust samples collected from floors or upholstered seats of 160 workplaces. RESULTS: Detectable Der p 1 levels were found in 86 (54%) workplaces Der f 1 in 87 (55%), Fel d 1 in 86 (54%) and Bla g 2 in 3 (1.9%). Der p 1 allergen concentrations expressed per weight were higher than the proposed sensitization thresholds in 7 samples, Der f 1 in 5, Fel d 1 in 6 and Bla g 2 in 3. The highest allergen levels were detected in samples from upholstered seats. A significant correlation was found between Der f 1 level on floors, expressed per surface, and indoor temperature (r = 0.39; P < 0.01). CONCLUSIONS: In our study we found that upholstered seats in workplaces in Italy may constitute a significant reservoir both of house dust mites and cat allergens. Exposure to these allergens in workplaces may represent a risk factor for elicitation of symptoms and/or induction/maintenance of inflammation in allergic individuals and might also constitute a risk factor for sensitization.  相似文献   

4.
Kim JL  Elfman L  Norbäck D 《Indoor air》2007,17(2):122-129
We studied reports on respiratory symptoms, asthma and atopic sensitisation in relation to allergen contamination in Korean schools and compared with data from a previous Swedish study performed in eight primary schools. Korean pupils (n = 2365) in 12 primary schools first completed a questionnaire. Then airborne and settled dust were collected from 34 classrooms and analyzed for allergens by ELISA. In both countries, boys reported more symptoms. The prevalence of wheeze was similar, while daytime [odds ratio (OR) = 14.0, 95% confidence interval (CI) = 9.0-21.9] and nocturnal breathlessness (OR = 3.1, 95% CI = 1.5-6.4) were much higher among Korean students. In Korean schools, dog allergen (Can f 1) was the most common followed by mite allergen (Der f 1), while cat (Fel d 1), dog, and horse allergen (Equ cx) were abundant in Sweden. Moreover, CO(2) levels were high in most Korean schools (range 907-4113 ppm). There was an association between allergen levels in dust and air samples, and number of pet-keepers in the classrooms. In conclusion, allergen contamination in Korean schools may be an important public issue. PRACTICAL IMPLICATIONS: This study showed that furry pet allergen contamination was common in both Korean and Swedish schools. In addition, house dust-mite (Der f 1) allergen contamination was common in Korean schools, probably because of transport of allergen from other environments. Transfer should therefore be minimized. Korean schools had high CO(2) levels and the concept of mechanical ventilation should be introduced. Measurement of airborne allergen levels is quite new and seems to be a more convenient and correct way to monitor allergen exposure in classrooms.  相似文献   

5.
Indoor environment has been associated with allergic disease. Further, it has been observed that the prevalences of allergic sensitization are different in different social groups. We therefore investigated the association between socioeconomic status (SES) and indoor bio-contaminants. House dust samples were collected from parents' and infants' mattress from 2166 families in Munich (62.2%) and Leipzig (37.8%), Germany. Major mite allergen Der p 1 and Der f 1, cat allergen Fel d 1, and endotoxin were extracted and quantified. Parental educational level and family equivalent income were used independently as socioeconomic indicators. Indoor endotoxin, mite allergen Der p 1, and the amount of sampled dust were not associated with the social factors. Mite allergen Der f 1 was slightly associated by family SES but without a consistent pattern. In families who are not cat owners, however, a negative association between the amount of cat allergen and family SES were observed. The observed negative association between cat allergen loads and concentrations in mattress and family SES in non-cat owners' homes indicated that community is an important source of cat allergen exposure. PRACTICAL IMPLICATIONS: The study indicated that community is a major source of cat allergen exposure especially in communities of low SES.  相似文献   

6.
Allergy to indoor allergens can cause frequent and severe health problems in children. Because little is known about the content of allergens in the indoor environments in Norway, we wanted to assess the levels of cat, dog and mite allergens in schools and day-care centers in Oslo. Allergen levels in dust samples from 155 classrooms and 81 day-care units were measured using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Additionally, we measured the levels of endotoxin in 31 day-care units, using the limulus amebocyte lysate test. Most of the dust samples contained detectable amounts of cat and dog allergens. In mattress and floor dust (day-care centers), and curtain and floor dust (schools) the median Fel d 1 levels were 0.17, 0.002, 0.02 and 0.079 microg/m2, while the median Can f 1 levels were 1.7, 0.03, 0.1 and 0.69 microg/m2, respectively. Levels of cat and dog allergens in school floor dust were associated with the number of pupils with animals at home. In contrast, <1% of the samples had measurable levels of the mite allergen Der p 1. Moreover, the levels of endotoxin tended to be higher in dust from floors (1.4 ng/m2) compared with that from mattresses (0.9 ng/m2). PRACTICAL IMPLICATIONS: To reduce allergen exposure, allergic individuals should be placed in the classes/rooms with the fewest pet owners. Moreover, mattresses in day-care centers are major reservoirs of cat and dog allergens and should be cleaned frequently.  相似文献   

7.
Zhao ZH  Elfman L  Wang ZH  Zhang Z  Norbäck D 《Indoor air》2006,16(6):404-413
We compared the school environment, asthma and allergy in 10 schools in Taiyuan, China, with eight schools in Uppsala, Sweden. In total 2193 pupils (mean age 13 years) participated. Chinese pupils had more respiratory symptoms, particularly daytime breathlessness after exercise (29.8% vs. 7.1%; P < 0.001), while cat allergy (1.2% vs. 6.6%; P < 0.001) and dog allergy (1.3% vs. 4.0%; P < 0.01) was less common. Cumulative incidence of asthma (1.8% vs. 9.5%; P < 0.001) and doctor's diagnosed asthma (1.2% vs. 9.0%; P < 0.001) were less common in China, indicating an under-diagnosis of asthma. Chinese classrooms were colder (mean 14.7 vs. 21.4 degrees C), more humid (mean 42% vs. 31% RH) and had higher CO2-levels (mean 2211 vs. 761 ppm). Levels of cat (Fel d1), dog (Can f1) allergens were low in settled dust from China (< 200 ng/g dust), but high in airborne dust on Petri-dishes (GM 16.8 ng/m2/day for Fel d1 and 17.7 for Can f1). The Swedish settled dust contained cat, dog and horse allergens in high levels (median 1300 ng/g, 1650 ng/g, 1250 U/g dust, respectively). In conclusion, there were large differences in the school environment, and in respiratory symptom and allergy. Allergen measurements in settled dust only may largely underestimate the classroom exposure. Practical Implications There is a need to improve the school environment, both in China and Sweden. The Swedish schools contained high levels of cat, dog and horse allergens and more amounts of open shelves and textiles that can accumulate dust and allergens. The air measurements indicated that Chinese schools may contain significant amounts of cat and dog allergen, and analysis of settled dust only may not reflect the true allergen exposure. Since the Chinese schools had no mechanical ventilation, they could not fulfill the ventilation standard in winter, and hence there is a need for improving the ventilation. The great discrepancy between respiratory symptoms and reports on asthma, and the high prevalence of attacks of breathlessness without wheeze, may have implication for future questionnaire studies on asthma in China.  相似文献   

8.
Studies that estimate indoor aeroallergen exposure typically measure a pre‐selected limited range of allergens. In this study, inhalable aeroallergen particles were quantified using the halogen immunoassay (HIA) to determine the contribution of fungal and non‐fungal aeroallergens to total allergen exposure. Bioaerosols from 39 homes of fungal‐allergic subjects were sampled using inhalable fraction samplers and immunostained by HIA using resident subject's immunoglobulin E (IgE) to detect allergen‐laden particles. Fungal aerosols as well as particles carrying mite, cat, and cockroach allergens were identified and enumerated by HIA. Reservoir dust‐mite (Der p 1), cat (Fel d 1), and cockroach (Bla g 1) allergen concentrations were quantified by ELISA. Fungal particles that bound subject's IgE in the HIA were 1.7 (bedroom)‐ and 1.4 (living room)‐fold more concentrated than Der p 1, Fel d 1, and Bla g 1 allergen particles combined. Predominant fungal conidia that bound IgE were derived from common environmental genera including Cladosporium and other fungi that produce amerospores. Airborne mite, cat, and cockroach allergen particle counts were not associated with reservoir concentrations determined by ELISA. This study demonstrates that inhalable fungal aerosols are the predominant aeroallergen sources in Sydney homes and should be considered in future exposure assessments.  相似文献   

9.
Exposure to allergens from house dust-mites (Der p 1) and domestic cats (Fel d 1) is associated with symptom severity in atopic subjects with asthma and rhinitis. Assessment of allergen exposure in the domestic environment is normally determined by measurement from a single floor site. We determined the variability of these allergens and protein throughout the whole living room floor area. Dust samples were collected from 1 m2 areas from 16 carpeted living room floors in Wellington, New Zealand, and analyzed for concentrations of Der p 1 and Fel d 1. Mean coefficients of variation for Der p 1 and Fel d 1 were 53.1% (range: 28.5-136.8) and 65.6% (range: 28.5-131), respectively. This study has demonstrated a large variation of house dust-mite and cat allergens within living room floors and thus a single sampling site may not be representative for assessment of an individual's exposure risk. House dust-mite and cat allergen levels from the center of the room, in front of a couch or chair, or from a corner of the room are similar to mean levels from the whole room, these sites may thus be representative of the whole living room floor in large-scale epidemiological studies.  相似文献   

10.
Exposure to allergens from house dust-mites (Der p 1) and domestic cats (Fel d 1) is associated with symptom severity in atopic subjects with asthma and rhinitis. Assessment of allergen exposure in the domestic environment is normally determined by measurement from a single floor site. We determined the variability of these allergens and protein throughout the whole living room floor area. Dust samples were collected from 1 m2 areas from 16 carpeted living room floors in Wellington, New Zealand, and analyzed for concentrations of Der p 1 and Fel d 1. Mean coefficients of variation for Der p 1 and Fel d 1 were 53.1% (range: 28.5-136.8) and 65.6% (range: 28.5-131.0), respectively. This study has demonstrated a large variation of house dust-mite and cat allergens within living room floors and thus assessment of a single sampling site may not be representative of an individual's exposure risk. House dust-mite and cat allergen levels from the center of the room, in front of a couch or chair, or from a corner of the room are similar to mean levels from the whole room. These sites may thus be representative of the whole living room floor in large-scale epidemiological studies.  相似文献   

11.
Smedje G  Norbäck D 《Indoor air》2001,11(2):127-133
In order to study the influence of furnishings and cleaning on the indoor air quality at school, 181 randomly chosen classrooms were investigated. The amounts of open shelves, textiles and other fittings were noted, data were gathered on cleaning routines, and a number of pollutants were measured in the classrooms. In classrooms with more fabrics there was more settled dust and the concentration of formaldehyde was higher. Classrooms with more open shelves had more formaldehyde, and more pet allergens in settled dust, and classrooms with a white board, instead of a chalk board, were less dusty. Classrooms mainly cleaned through wet mopping had more airborne viable bacteria but less settled dust than classrooms mainly cleaned by dry methods. In rooms where the desks and curtains were more often cleaned, the concentrations of cat and dog allergen in settled dust were lower. It is concluded that furnishings and textiles in the classroom act as significant reservoirs of irritants and allergens and have an impact on the indoor air quality at school.  相似文献   

12.
Wickens K  Lane J  Siebers R  Ingham T  Crane J 《Indoor air》2004,14(3):217-222
Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment and the vacuum hose (the reference method) and (2) the ALK device. Duplicate dust samples were collected for 2 min from 2 m(2) of 37 living room floors and from each longitudinal half of 37 mattresses. Measurement of Der p 1 and Fel d 1 were by double monoclonal antibody enzyme-linked immunosorbent assay (ELISA) and endotoxin by a Limulus Amobocyte Lysate assay. Geometric mean ratios (95% confidence intervals) were calculated to show the differences between sampling devices for each measurement. Compared with the ALK device, the reference method collected significantly more dust from floors (sevenfold) and mattresses (threefold) and more total Der p 1, Fel d 1, and endotoxin in both sites. Floor, but not mattress, Der p 1 concentrations were also significantly higher (threefold) using our reference method. We recommend that, in order to minimize sampling device bias, allergen and endotoxin are expressed as a concentration, and that the bed is considered the major source of allergen exposure. Practical Implications Dust sampling equipment can influence the dust yield. In order to have confidence in comparisons of allergen and endotoxin reservoir levels between centers, standardization in the use of sampling equipment is important.  相似文献   

13.
This study examined: (i) biocontaminant levels in flooded homes of New Orleans two years after the flooding; (ii) seasonal changes in biocontaminant levels, and (iii) correlations between biocontaminant levels obtained by different environmental monitoring methods. Endotoxin, (1 → 3)-β-d-glucan, fungal spores, and dust mite allergens were measured in 35 homes during summer and winter. A combination of dust sampling, aerosolization-based microbial source assessment, and long-term inhalable bioaerosol sampling aided in understanding exposure matrices. On average, endotoxin found in the aerosolized fraction accounted for < 2% of that measured in the floor dust, suggesting that vacuuming could overestimate inhalation exposures. In contrast, the (1 → 3)-β-d-glucan levels in the floor dust and aerosolized fractions were mostly comparable, and 25% of the homes showed aerosolizable levels even higher than the dust-borne levels. The seasonal patterns for endotoxin in dust and the aerosolizable fraction were different from those found for (1 → 3)-β-d-glucan, reflecting the temperature and humidity effects on bacterial and fungal contamination. While the concentration of airborne endotoxin followed the same seasonal trend as endotoxin aerosolized from surfaces, no significant seasonal difference was identified for the concentrations of airborne (1 → 3)-β-d-glucan and fungal spores. This was attributed to the difference in the particle size; smaller endotoxin-containing particles can remain airborne for longer time than larger fungal spores or (1 → 3)-β-d-glucan-containing particles. It is also possible that fungal aerosolization in home environments did not reach its full potential. Detectable dust mite allergens were found only in dust samples, and more commonly in occupied homes. Levels of endotoxin, (1 → 3)-β-d-glucan, and fungi in air had decreased during the two-year period following the flooding as compared to immediate measurements; however, the dust-borne endotoxin and (1 → 3)-β-d-glucan levels remained elevated. No conclusive correlations were found between the three environmental monitoring methods. The findings support the use of multiple methods when assessing exposure to microbial contaminants.  相似文献   

14.
Mite allergens are involved in airway sensitization and allergic diseases. We evaluated the exposure to house dust-mite (Der p 1 and Der f 1) and pet (Fel d 1 and Can f 1) allergens in hotels in Uberlandia, Midwestern Brazil. A total of 140 dust samples were collected from bedding (n = 98) and carpet (n = 42) of bedrooms in 20 hotels enrolled for this study. Geometric mean (GM) levels of Der f 1 (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) were significantly higher than Der p 1 (0.15 microg/g of dust; 95% CI: 0.13-0.18 microg/g) in bedding dust samples (P < 0.001), regardless of the hotel classes. Der f 1 levels were significantly higher in bedding (11.30 microg/g of dust; 95% CI: 8.34-15.30 microg/g) than carpet (6.32 microg/g of dust; 95% CI: 4.31-9.26 microg/g) dust samples (P < 0.05). High levels of Der f 1 (>10 microg/g of dust) were found in 58%, 76%, and 69% of dust samples from Simple, Economical, and Tourist/Superior hotels, respectively, while GM levels of Fel d 1 (0.11 microg/g of dust; 95% CI: 0.09-0.14 microg/g) and Can f 1 (0.30 microg/g of dust; 95% CI: 0.20-0.44 microg/g) were relatively low. These results indicate that Der f 1 is the predominant allergen in hotels in Uberlandia, especially in bedding dust samples, regardless of the hotel classes and could represent an important risk factor for exacerbation of allergic symptoms in previously mite-sensitized guests. PRACTICAL IMPLICATIONS: Mites and pets are important sources of indoor allergens. Most people spend the greatest part of their time indoors. Hotels can constitute an important allergen reservoir of the indoor environment and could represent an important risk for exacerbation of allergic symptoms in previously sensitized guests. Thus, hotels should also be included for planning indoor allergen avoidance as part of a global management strategy, especially in patients with respiratory allergy.  相似文献   

15.
Considering that high school students spend a large proportion of their waking hours in the school environment, this could be an important location for exposure to indoor allergens. We have investigated the levels of mouse and cockroach allergens in the settled dust and air from 11 schools in a major northeastern US city. Settled dust samples were vacuumed from 87 classrooms, three times throughout the school year. Two separate air samples (flow = 2.5 lpm) were collected by 53 students over a 5-day period from both their school and their home. Mouse allergen (MUP) in the dust varied greatly between schools with geometric means ranging from 0.21 to 133 microg/g. Mouse allergen was detectable in 81% of the samples collected. Cockroach allergen (Bla g 2) ranged from below limit of detection (<0.003 microg/g) to 1.1 microg/g. Cockroach allergen was detected (>0.003 microg/g) in 71% of the dust samples. Bla g 2 was detected in 22% of airborne samples from the schools. By comparison, mouse allergen was only detected in 5%. These results indicate that the school may be an important location for exposure to allergens from mice and cockroaches and is an indoor environment that should be considered in an overall allergen intervention strategy. PRACTICAL IMPLICATIONS: To date, cockroach and mouse allergen intervention strategies have been mainly focused on the home environment. Considering that children spend a significant amount of time in schools, some studies have assessed cockroach allergen levels in schools. This study provides a clearer picture of the distribution and variability of not only cockroach allergen, but also mouse allergen in the school environment. In addition, this study describes limitations of personal air sampling in a student population. Our results suggest that although cockroach and mouse allergens are commonly recovered in classroom dust samples of inner city schools, cockroach allergens are recovered in the personal air samples with a greater frequency relative to mouse allergens.  相似文献   

16.
There is evidence that sick building syndrome (SBS) is caused, in part, by indoor surface pollution (ISP): contaminants such as dust, fibres and micro-organisms, deposited on or in surfaces in buildings. A study is described which clarifies the relative importance of a number of possible causes of SBS in a single building. The building, which had a high initial prevalence of SBS symptoms, was used in a doubleblind controlled intervention study with weekly symptom questionnaires. The four interventions were: ventilation system cleaning, air filtration, hot-water extraction cleaning of chairs and carpets, plus high grade filter vacuuming and dusting, and dust mite treatment (application of liquid nitrogen). Only the last two interventions brought about a reduction in symptoms. It is concluded that cleaning which effectively reduces ISP can reduce SBS symptoms. This may be related to the presence of dust mites in furnishings. Improved cleaning may entail better cleaning specifications and/or consideration of requirements for cleaning when selecting and positioning office furniture. If ISP and the temporary local pollution levels created by it are a problem, then monitoring of ambient conditions (by instruments or by human assessors) will not adequately represent the conditions to which occupants are exposed  相似文献   

17.
Moisture and mold problems in buildings contaminate also the furniture and other movable property. If cleaning of the contaminated furniture is neglected, it may continue to cause problems to the occupants even after the moisture-damage repairs. The aim of this study was to determine the effectiveness of high-efficiency ozone treatment in cleaning of the furniture from moisture-damaged buildings. In addition, the effectiveness of two cleaning methods was compared. Samples were vacuumed from the padded areas before and after the treatment. The microbial flora and concentrations in the dust sample were determined by quantitative cultivation and QPCR-methods. The immunotoxic potential of the dust samples was analyzed by measuring effects on cell viability and production of inflammatory mediators in vitro. Concentrations of viable microbes decreased significantly in most of the samples after cleaning. Cleaning with combined steam wash and ozonisation was more effective method than ozonising alone, but the difference was not statistically significant. Detection of fungal species with PCR showed a slight but nonsignificant decrease in concentrations after the cleaning. The immunotoxic potential of the collected dust decreased significantly in most of the samples. However, in a small subgroup of samples, increased concentrations of microbes and immunotoxicological activity were detected. This study shows that a transportable cleaning unit with high-efficiency ozonising is in most cases effective in decreasing the concentrations of viable microbes and immunotoxicological activity of the furniture dust. However, the method does not destroy or remove all fungal material present in the dust, as detected with QPCR analysis, and in some cases the cleaning procedure may increase the microbial concentrations and immunotoxicity of the dust.  相似文献   

18.
Abstract Insufficient cleaning may be a cause of the Sick Building Syndrome. Various improvements in cleaning methods have been tested in order to clarify whether they reduced the concentration of airborne dust, and the concentration of dust on surfaces, or whether the concentration of different microbiological components in the dust was reduced. The interventions were performed in an administration building, a school and a kindergarten. Dust measurements were performed on one day every week for a period of 28 weeks, using different interventions. The airborne dust concentration was measured by sampling on filters during the day. The concentration of surface dust was measured by the BM-Dustdetector foil sampling method. Dust samples were collected from the floors, after which analyses for different microbiological components were performed. Sampling from surfaces and the floor were performed prior to cleaning in order to ascertain the levels to which the room occupants had been exposed. One of the findings was a reduction in the dust concentration on the so-called easily accessible surfaces. Correlations between surface dust and airborne dust were also found. Furthermore, correlations between the measurements and other factors, such as activity during the day, and the climate, were obtained. Important findings of the study were the observations made on the relations between cleaning and dust in the indoor environment and the measuring methods applied.  相似文献   

19.
Distribution variations of multi allergens at asthmatic children's homes   总被引:1,自引:0,他引:1  
Increasing asthma prevalence is evident in many countries and childhood asthma has also become one of the most common chronic diseases in children. Exposure to indoor allergens has been be attributed to a significant increase in asthma occurrence. Meanwhile, allergen distribution varies widely among different countries. This brief investigation reports the distribution of common indoor allergens, such as mite (Dermatophagoides pteronyssinus, Der p 1 and Der p 2), cat (Felis domesticus, Fel d 1), and German cockroach allergens (Blattella germanica, Bla g 1) at different sites of asthmatic children in Taiwan. Approximately 40 asthmatic children's homes participated in this study and the cohort was followed prospectively for approximately 6 months, starting in December until the following May. Dust samples were collected from each child's mattress, and bedroom and living room floors. All samples were analyzed with monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA). Statistical difference of Der p 1 concen trations is observed among those on the mattress, bedroom and living room floor, except for in May. Seasonal variation in Der p 1 levels on the mattress and bedroom floor is also significant (P < 0.025 and 0.001, respectively). Distributional variation seems to be significant for most allergens among sites within homes in most seasons. Therefore, if only one sample is to be taken, the month of May would be a more ideal choice of study period, and detailed sampling across sites appears to be necessary should the true environmental exposure of allergens be desired.  相似文献   

20.
The in vitro potency of house dust to induce cytokine response in A549 lung epithelial cells was studied. Dusts collected from carpet, bed, shelf and floor of a villa and an apartment by vacuuming were found to trigger the production of interleukin-8 (IL-8) and interleukin-6 (IL-6) in a dose-dependent manner, and the interleukin production was several-fold higher than of swine dust (used as a positive control). The IL-8 and IL-6 production of pure Escherichia coli lipopolysaccharide was significantly lower than of the dusts and a peptidoglycan-polysaccharide complex did not show any stimulatory effect at all. The lipopolysaccharide and peptidoglycan contents of the samples were determined by gas chromatography-tandem mass spectrometry analysis of, respectively, 3-hydroxy fatty acids and muramic acid; in addition, ergosterol was monitored for fungal biomass. The inflammatory properties of house dust upon inhalation may be reflected in its high potency to induce cytokine response in lung epithelial cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号