首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Diatomaceous earth is a noncrystalline form of silica; in processing, calcining leads to formation of cristobalite, a form of crystalline silica. Four hundred ninety-two currently employed diatomaceous earth workers in a large mine and processing facility had chest radiographs performed and interpreted by the International Labour Office (ILO) system. Two hundred sixty-seven subjects underwent spirometry testing. Exposure indices for total dust (largely diatomaceous earth) and cristobalite were reconstructed for each individual based upon personnel records. Analysis demonstrated the following prevalences of radiographic findings: 5% had ILO scores > or = 1/0, and 25% had scores of 0/1 or higher. Regression analyses showed that there was a relationship between both total cristobalite exposure and total dust (largely diatomaceous earth) exposure and the ILO score. Radiographic patterns are not typical of those of classic silicosis. Linear regression analyses for forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and FEV1/FVC ratio did not demonstrate a relationship between cumulative exposure and lung function. Such analyses were performed using all subjects and stratified by smoking status. There were differences in spirometric data according to radiographic ILO category, but the results were inconsistent and did not permit determining if physiologic changes are associated with radiographic change or if this is due to confounding. Overall, the study suggests that diatomaceous earth pneumoconiosis (radiographically defined) is an entity distinct from silicosis. Recent exposure levels may produce radiographic abnormalities but do not lead to demonstrable physiologic effect. The prevalence of the disorder has diminished markedly in response to modern dust control measures. Ongoing medical surveillance is recommended in workers with potential exposure to significant quantity of material.  相似文献   

2.
BACKGROUND: Historical cohort studies in England have found that impaired fetal growth and lower respiratory tract infections in early childhood are associated with lower levels of lung function in late adult life. These relations are investigated in a similar study in Scotland. METHODS: In 1985-86 a follow up study was carried out of 1070 children who had been born in St Andrew's from 1921 to 1935 and followed from birth to 14 years of age by the Mackenzie Institute for Medical Research. Recorded information included birth weight and respiratory illnesses. The lung function of 239 of these individuals was measured. RESULTS: There was no association between birth weight and lung function. Pneumonia before two years of age was associated with a difference in mean forced expiratory volume in one second (FEV1) of -0.39 litres (95% confidence interval (CI) -0.67, -0.11; p = 0.007) and in mean forced vital capacity (FVC) of -0.60 litres (95% CI -0.92, -0.28; p < 0.001), after controlling for age, sex, height, smoking, type of spirometer, and other illnesses before two years. Similar reductions were seen in men and women. Bronchitis before two years was associated with smaller deficits in FEV1 and FVC. Asthma or wheeze at two years and older and cough after five years were also associated with a reduction in FEV1. CONCLUSIONS: The relation between impaired fetal growth and lower lung function in late adult life seen in previous studies was not confirmed in this cohort. The deficits in FEV1 and FVC associated with pneumonia and bronchitis in the first two years of life are consistent with a causal relation.  相似文献   

3.
To assess whether the evolution to pneumoconiosis may be suspected in coal miners, we conducted a 4-yr longitudinal study of 80 dust-exposed miners with chest X-ray findings classified 0/1 or 1/0 according to the International Labor Organization (ILO) classification (exposed to coal mine dust, suspected of pneumoconiosis [ES group]) and two control groups having normal X-rays. The first of these latter two groups included 80 miners with similar exposure to that of the first group (exposure with normal X-rays [EN]), whereas the second group consisted of markedly less exposed miners (no exposure with normal X-rays [NN]). The protocol comprised a questionnaire on respiratory symptoms and smoking, assessment of cumulative coal-mine-dust exposure, X-rays, computed tomographic (CT) scans, and lung-function tests. The study was conducted in 1990 and 1994 by the same medical team. At the end of the follow-up, 24 members of the ES group had worsened X-ray findings, and 10 of them had X-ray findings classified as 1/1 or greater. In the EN and NN groups, six and one subjects, respectively, had worsened X-ray findings. At the first examination, subjects who developed pneumoconiosis had significantly lower values for FEV1/FVC ratio, maximum midexpiratory flow (MMEF), and maximal forced expiratory flow at 25% of vital capacity (FEF25%), and higher CT-scan micronodule scores. This latter score and FEF25% were significantly associated with the evolution to pneumoconiosis in the ES group, and scanner micronodule score and MMEF were significantly associated with this in all three groups combined. Worsening findings on X-ray and change to pneumoconiosis must be controlled in coal miners. The findings in this study offer the possibility of identifying miners who especially need follow-up and monitoring.  相似文献   

4.
Previous studies have suggested that excessive losses of FVC and FEV1 were occurring in Vermont granite workers despite the fact that mean quartz levels existing in the industry were below the current OSHA standard of 100 micrograms/m3. We reexamined these losses in granite workers over an 8-year period, testing the workforce biennially from 1979 to 1987. All workers, including stone shed, quarry, and office, were offered forced spirometry using a 10-L water-sealed spirometer (Collins). In the peak year of participation (1983), 887 workers out of a total of approximately 1,400 were tested. Estimates of longitudinal loss were based on 711 workers who participated in at least three of the surveys. The mean age of this group was 42.9 years, and the mean years employed was 19.3 years; 21.4 percent were non-smokers (NS), 34.2 percent were ex-smokers (ES), and 44.4 percent were current smokers (CS). Average annual losses of FVC were 0.018 (SD = 0.056) L (CS, 0.025 L; NS, 0.006 L: and ES, 0.016 L). Average annual losses of FEV1 were 0.030 (SD = 0.041) L (CS, 0.038 L; NS, 0.020 L; and ES, 0.027 L). Analysis of covariance indicated that losses were related to the initial values for FVC or FEV1, height, age, and smoking status. After adjusting for these variables, the losses of both FVC and FEV1 were not correlated with years employed in the granite industry. No significant differences existed in the loss of FVC or FEV1 in categories of workers exposed to different levels of granite dust, eg, office, quarry, and stone shed workers. The annual losses of pulmonary function were significantly smaller than those estimated previously, which were 0.070 to .080 L in FVC, and 0.050-0.070 L in FEV1. We conclude that dust levels in the Vermont granite industry, which have been in conformance with OSHA permissible exposure limits, do not accelerate pulmonary function loss.  相似文献   

5.
We investigated the relationship between the pulmonary test variable measurements and self-reported asthma and wheezing from a cross-sectional study conducted in Saskatchewan. Based on the responses to the questionnaire, the subjects were classified into asthmatic, wheezing, and asymptomatic groups. For both male and female subjects the mean values of forced expiratory volume in 1 s (FEV1), forced expiratory flow during the middle half of the forced vital capacity (FEF25-75), and FEV1/FVC ratio were lowest in asthmatics, followed by wheezing and asymptomatic groups, respectively. This trend was also observed in forced vital capacity (FVC) for men but not for women. After adjusting for current smoking status, the trend in the means across the three groups was statistically significant in men for FEV1 (p = 0.03), FEF25-75 (p = 0.002), and FEV1/FVC ratio (p = 0.002) and in women for FEF25-75 (p < 0.001) and FEV1/FVC ratio (p < 0.001). The differences in the adjusted means of FVC, FEV1, FEF25-75, and FEV1/FVC ratio between asymptomatic subjects and the other two groups were significant in both male and female subjects. Significant differences were also observed between asthmatics and wheezing groups in the adjusted means of FEF25-75 and FEV1/FVC ratio in male and female subjects. We conclude that the self-report of asthma has a high level of validity against the criterion of concurrently measured pulmonary test variables.  相似文献   

6.
We studied 233 male workers employed in two brick-manufacturing plants and 149 matched control workers. The mean age of the brick workers was 35 years, with a mean duration of employment in this industry of 16 years. The prevalence of chronic respiratory symptoms as well as acute symptoms during the work shift were recorded. Lung function was measured on Monday during the work shift by recording maximum expiratory flow-volume (MEFV) curves, from which the forced vital capacity (FVC), the one-second forced expiratory volume (FEV1) and flow rates at 50% and the last 75% of the FVC (FEF50, FEF75) were measured. The results of periodic chest roentgenograms were reviewed. There was a significantly higher prevalence of chronic cough (31.8%), chronic phlegm (26.2%), and chest tightness (24.0%) in exposed workers, compared with control workers (20.1%; 18.1%; 0%) (P < 0.05). This increased symptom frequency was also documented among nonsmokers studied by age and by length of employment, suggesting a work-related effect. Among work shift-related symptoms, high prevalences were noted for upper respiratory tract symptoms (e.g., dry throat, eye irritation, throat irritation). The measured FVC and FEV1 were significantly lower than predicted for brick workers and suggested a restrictive pattern. The mean FVC (as a percent of predicted) was 78.1% and FEV1 was 88.1%. The FEF50 and FEF25 were not significantly decreased. A multiple regression analysis with age, exposure, and smoking as predictors and lung function parameters as response variables showed a significant effect between exposure and FVC. Significant chest roentgenographic abnormalities were not documented. These findings of a restrictive lung function pattern in brick workers with normal chest roentgenograms may suggest early interstitial disease. Additionally, a bronchitic component, as suggested by the respiratory symptoms, may also be present.  相似文献   

7.
We examined the effects from subjects, technicians and spirometers on within-session variability in successful recordings of forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in 4989 asymptomatic never-smoking men. All eligible men aged 30-46 years living in western Norway (n = 45,380) were invited to a cross-sectional community survey. Information on respiratory symptoms, smoking habits and occupational exposures was obtained from a self-administered questionnaire. Three successful FEV1 and FVC recordings were obtained in 26,368 attendants using three dry-wedge bellow spirometers operated by 10 different technicians. Within-subject standard deviation (SD) from three recordings of FEV1 and FVC was on average 102 and 106 ml, respectively, and increased with height (14 and 17 ml, respectively, per 10 cm) and body mass index (BMI) (11 and 14 ml, respectively, per 5 kg m-2). Between-subject SD of the mean of three FEV1 and FVC recordings was 591 and 754 ml, respectively, and increased in groups of increasing height (43 and 40 ml, respectively, per 10 cm). Small, but significant, differences were observed between technicians in within-subject SD and in levels of FEV1 and FVC. Homogeneity of between-subject variability, necessary for linear regression analysis, was obtained using FEV1 and FVC divided by height squared. In conclusion, within-subject variability in three successful spirometric recordings was small, but dependent on height and BMI of the subjects as well as technician performance. The observed heterogeneity in between-subject variation in FEV1 and FVC levels disappeared when each variable was divided by height squared. Novel multiple linear regression equations for FEV1/height2 and FVC/height2 were developed to be used in evaluating the effects from occupational airborne exposures in Nordic men aged 30-46 years.  相似文献   

8.
Objective: To examine the cross-sectional association between hostility and pulmonary function (PF) and its consistency across race/ethnicity-gender groups. Design: Data were from the Coronary Artery Risk Development in (Young) Adults (CARDIA) cohort study (N = 4,629). Participants were recruited from 4 metropolitan areas in the United States, ages 18-30 years at baseline in 1985-1986, approximately balanced across race/ethnicity (Black, White) and gender. Main Outcome Measures: Main outcome measures were percent predicted values for forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC). Results: In full-sample multiple linear regression analyses, each 1 standard deviation (SD) increase in hostility was associated with a 0.66% decrease in FEV? (p = .0002) and a 0.60% decrease in FVC (p = .0006). This inverse association of hostility with PF remained after controlling for age, height, current socioeconomic status (SES), participant smoking status, and asthma and is more consistent than that of smoking and PF. In stratified analyses, each 1 SD increase in hostility predicted statistically significant reductions in PF for Black women, White women, and Black men. For White men, hostility showed no statistically significant relation with PF, although the pattern relating hostility to PF was similar to the pattern in the other three groups. Further, both of the post hoc three-way interaction terms for hostility, race/ethnicity, and gender predicting FEV? and FVC were nonsignificant. Conclusion: PF was inversely associated with hostility across race/ethnicity and gender, independent of age, height, current SES, smoking, and asthma. On the basis of these cross-sectional findings, the authors hypothesize that higher hostility will predict a more rapid decline in PF. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

9.
During 1990 all present and retired china clay workers in the United Kingdom were invited to take part in a chest health survey. A total of 4401 china clay workers participated representing over 70% of current employees and 17% of pensioners. The survey consisted of a chest x ray film, lung function measurements, and a questionnaire on respiratory symptoms and smoking habits. The chest x ray films were read by three readers to the International Labour Office (ILO) 1980 classification. Full details of occupational history for each participant were available and for each employee an estimate of total exposure to china clay dust was derived from representative dust concentrations for each location and job. These were based on measured dust concentrations after 1978 and on estimates before 1978. Analyses of the data were carried out to investigate the relations between exposure, x ray film category, lung function, and respiratory symptoms. The percentage of people with small opacities greater than major x ray film category 1 was 0.8% (lower than in previous studies). Dust concentrations have been reduced in recent years, averaging 1.7 mg m-3 for dryers in 1990 compared with 3.5 mg m-3 in 1978. The lower effect of exposure after 1971, compared with earlier exposure, was confirmed by the analyses. After 1971 the milling of dried china clay (Atritor mills) was found to be the occupation with the highest effect on x ray film category. The relation between total exposure to china clay dust and x ray film category is such that a typical non-smoker worker employed in the most dusty of current occupations may expect to reach the lower limit of category 1 after about 42 years continuous employment in that job at current exposures. Both forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were found (as in other studies) to decline with age, more rapidly for smokers than non-smokers at the rates for FVC of 0.035 l/y and 0.033 l/y, whereas for FEV1 the rates are 0.039 l/y for smokers and 0.034 l/y for non-smokers. Changes in x ray film category are also related to lung function , a change of one major category being equivalent to about six years of aging in its effect on FEV1.  相似文献   

10.
Human immunodeficiency virus (HIV) infection has been associated with a wide spectrum of pulmonary disease. We report three HIV-seropositive patients with rapidly worsening airway obstruction associated with bronchiectasis. All subjects (age range 33-39 yrs) were cigarette smokers. Two had previously used intravenous drugs. The CD4 lymphocyte count ranged 40-250 cells x mm(-3). All individuals had complained of increasing dyspnoea for 3-6 months. Within 1 yr, they all developed severe airway obstruction with a decrease in both forced expiratory volume in one second (FEV1) and ratio of FEV1 to forced vital capacity (FEV1/FVC) to less than 60% of predicted value, and a decrease in mean forced expiratory flow at 25-75% of the forced vital capacity (FEF25-75) to less than 35% of predicted value. Computed tomography of the chest disclosed bilateral dilated and thickened bronchi. No classical causes of genetic or acquired bronchiectasis were identified in our patients. Recurrent bacterial bronchitis occurred in the follow-up period of the three patients. In conclusion, unusually rapid airway obstruction associated with bronchiectasis should be added to the wide spectrum of respiratory complications of human immunodeficiency virus infection.  相似文献   

11.
An industry-wide pulmonary morbidity study was undertaken to evaluate the respiratory health of employees manufacturing refractory ceramic fibers at five US sites between 1987 and 1989. Refractory ceramic fibers are man-made vitreous fibers used for high temperature insulation. Of the 753 eligible current employees, 742 provided occupational histories and also completed the American Thoracic Society respiratory symptom questionnaire; 736 also performed pulmonary function tests. Exposure to refractory ceramic fibers was characterized by classifying workers as production or nonproduction employees and calculating the duration of time spent in production employment. The risk of working in the production of refractory ceramic fibers and having one or more respiratory symptoms was estimated by adjusted odds ratios and found to be 2.9 (95 percent confidence interval 1.4-6.2) for men and 2.4 (95 percent confidence interval 1.1-5.3) for women. The effect of exposure to refractory ceramic fibers on forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), the ratio of the two (FEV1/FVC), and forced expiratory flow (liters/second) between 25 percent and 75 percent of the FVC curve (FEF(25-75)) was evaluated by multiple regression analysis using transformed values adjusted for height, by dividing by the square of each individual's height. For men, there was a significant decline in FVC for current and past smokers of 165.4 ml (p < 0.01) and 155.5 ml (p = 0.04), respectively, per 10 years of work in the production of refractory ceramic fibers. For FEV1, the decline was significant (p < 0.01) only for current smokers at 134.9 ml. For women, the decline was greater and significant for FVC among nonsmokers, who showed a decrease of 350.3 ml (p = 0.05) per 10 years of employment in the production of refractory ceramic fibers. These findings indicate that there may be important sex differences in response to occupational and/or environmental exposure.  相似文献   

12.
The association between exposure to dust and pulmonary function was studied by longitudinal and cross sectional analyses in a group of United States underground coal miners beginning work in or after 1970. Quantitative estimates of exposure to respirable coal mine dust were derived from air samples taken periodically over the entire study period. The cohort included 977 miners examined both in round 2 (R2) (1972-5) and round 4 (R4) (1985-8) of the National Study of Coal Workers' Pneumoconiosis. Multiple linear regression models were developed for both cross sectional (pulmonary function at R2 and R4) and longitudinal (change in pulmonary function between R2 and R4) analyses with exposure partitioned into pre-R2 and post-R2 periods and controlled for covariates including smoking history. The results indicate a rapid initial (at R2) loss of FVC and FEV1 in association with cumulative exposure of the order of 30 ml per mg/m3-years. Between R2 and R4 (about 13 years) no additional loss of function related to dust exposure was detected although the percentage of predicted FVC and FEV1 did decline over the period. After some 15 years since first exposure (at R4), a statistically significant association of cumulative exposure with FEV1 of about -5.9 ml per mg/m3-years was found. These results indicate a significant non-linear effect of exposure to dust on pulmonary function at dust concentrations present after regulations took effect. The initial responses in both the FVC and FEV1 are consistent with inflammation of the small airways in response to exposure to dust.  相似文献   

13.
To establish the spirometric values for normal, healthy Chinese women in Taiwan, the spirometry of 506 life-long non-smoking, healthy Chinese women was examined, including 140 subjects over the age of 60 years. Significant correlations among age, height and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC%, peak expiratory flow (PEF), Vmax75, Vmax50, Vmax25 were found. However, there were no significant correlations between age and FEV1/FVC%, nor age and Vmax25 in the elderly group. FEV1 (FEV1*) and FVC (FVC*) were standardized to the overall mean height for elderly women using Cole's formula. The decline in FEV1* and FVC* with age were observed. The predicted value for the average 70-year-old woman with a height of 1.5 m derived from the present study is compared with those from other surveys of the elderly. The values from the present study are somewhat higher than the values from the Hong Kong study. The authors believe the fact that all of the present subjects were life-long non-smokers might explain the differences.  相似文献   

14.
Sensitivity of forced expiratory flow between 25% and 75% of the vital capacity (FEF25-75) in detecting airway obstruction was investigated in 14 children with mild-moderate asthma, allergic to house dust mites, while at high altitude (1756 m). Forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), FEF25-75, and peak expiratory flow (PEF) were measured every 2 weeks for 12 weeks (total, 84 measurements). The presence or absence of wheezing at the chest auscultation was ascertained before each test. During the study period, a significant improvement of both mean (SD) FEF25-75 [61 (12)% vs. 68 (11)% of the predicted value, p = 0.005] and PEF [95 (16)% vs. 103 (13)%, p = 0.002] was observed. FEV1 changed only marginally [82 (7)% vs. 86 (6)%, p = 0.05]. Wheezing was present on 12/84 occasions. Wheezing was associated with abnormal FEF25-75 values on most occasions but not with abnormal FEV1 or PEF. FEF25-75 was decreased on 51% of days in which wheezing was absent. FEV1 and PEF were, respectively, normal in 69% (p < 0.0001) and 92% (p < 0.0001) of measurements in which FEF25-75 was abnormal. These results suggest that FEF25-75 may be considered a good indicator of airflow obstruction and a sensitive marker of respiratory improvement in asthmatic children during reduced antigen exposure.  相似文献   

15.
OBJECTIVES: To examine the effect of chronic exposure to welding fumes on pulmonary function by a direct estimate of fumes accumulated in the lungs. METHODS: The strength of the residual magnetic field of externally magnetised lungs (LMF) was used as an estimate of fumes accumulated in the lungs. The results of forced spirometry manoeuvres obtained in 143 of 153 male welders in the original sample were cross sectionally evaluated according to LMF. Seven conventional forced spirogram indices and two time domain spirogram indices were used as pulmonary function indices, and height squared proportional correction was performed when necessary. RESULTS: The distribution of LMF values was considerably skewed towards positive. There was a weak but significant positive relation between age and log transformed LMF. Obstructive pulmonary function indices correlated well with LMF. After adjustment for age and smoking, however, a significant association with LMF was only found with percentage rate of forced expiratory volume in one second (FEV1%) divided by forced vital capacity (FVC) and mu, and average component of assumed time constant distribution of lung peripheral units. Neither FVC nor vital capacity (VC), as indices of restrictive disorders, showed a significant association with LMF. Based on the results of multiple regression analyses, a 0.6% decrease in FEV1% and 0.039 unit increase in mu were expected for each doubling of LMF. CONCLUSION: Obstructive changes in pulmonary function were found to be related to level of cumulative exposure to welding fume in male Japanese arc welders after controlling for age and smoking, assuming that LMF adequately reflects accumulation of welding fumes in the lungs.  相似文献   

16.
In order to determine both clinical and spirometric changes due to high environmental concentrations of wheat dust at a wheat processing plant mill, 48 exposed men and 48 age and antroprometrically-matched, non-exposed apparently healthy men were studied. In both groups a medical and occupational history were taken, and spirometric measurements were carried out, that included Forced Vital Capacity (FVC), Forced Expiratory Volume at the first second (FEV1), Peak Flow Rate (PFR), Forced Percentual Expiratory Volume (FEV%), Forced Percentual Vital Capacity (FVC%), Forced Expiratory Flow at 25% (FEV25%), at 50% (FEV50%) and at 75% (FEV75%) of their Forced Vital Capacity, which were analyzed through Corzo's predictive equations and the lung deterioration's criteria by USA's Thoracic Association. The environmental wheat dust was determined by gravimetry and its concentration was higher than the legally admitted (3/5, 60%). There was a decrease in the PFR, FEV%, FEV25% and FEV75%. (p < 0.05). In addition, 4 restrictive and 1 obstructive syndrome were detected in the exposed workers and none in the control group. The spirometric values diminished in a positive correlation with the time of exposure and smoking habits. There was no correlation between the clinical findings and the dust concentration but it did exist with the spirometric values. It is concluded that in this plant, the wheat dust exposed workers have a diminished spirometric values.  相似文献   

17.
The relative contributions of genetic and environmental components in the variability of lung function measurements were studied in 54 twin pairs. Thirty pairs of monozygote (MZ) twins and 24 pairs of dizygotic (DZ) twins were examined. All measurements were made with 9-litre closed-circuit-type expirographs using standard spirometric techniques, except for peak expiratory flow rate (PFER) which was recorded with a Wright peak flow meter. Within-pair variances for inspiratory capacity (IC), vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced mid-expiratory flow (FEV25-75%), forced end-expiratory flow (FEF75-85%), maximum expiratory flow (FEF200-1200ml), forced maximum voluntary ventilation MVVF) and PEFR were significantly smaller (p < 0.01) in MZ twins than in DZ twins. Tidal volume (VT), inspiratory reserve volume (IRV), expiratory reserve volume (ERV), forced expiratory volume in 1 second as a percentage of forced vital capacity (FEV1%), and forced expiratory time (FET) were not significantly different. Within-pair correlations were all higher in MZ than DZ twins. All measurements except for VT and PEFR showed high levels of heritability (23-99%). All measurements were positively and significantly correlated with physical characteristics such as weight, standing height, surface area, arm-span, chest circumference and age, except FEV1% and FET. Residual values adjusted for physical characteristics showed similar results to unadjusted values in most cases. These data indicate that major lung function measurements are possibly influenced more by genetic than environmental factors. Genetically influenced measurements show higher levels of heritability estimates and suggest that genetic determination of lung function is possibly independent of the influence of physical characteristics.  相似文献   

18.
The United States Public Health Service examined 1,438 surface coal miners to determine the prevalence of coal worker's pneumoconiosis (CWP), chronic bronchitis, and ventilatory impairment among them. Four percent (fifty-nine individuals) showed some roentgenographic evidence of pneumoconiosis, but only seven miners had films interpreted as CWP of category 2 or greater (according to the UICC/Cincinnati classification system). Moreover, most of the affected miners had worked in underground coal mines for prolonged periods. Significant decrements in pulmonary function to increasing exposure to surface mine dust were demonstrated only in the forced vital capacity of smokers. Increased prevalence of chronic bronchitis with increasing exposure was found in all smoking categories. However, significant airway obstruction was an uncommon finding (6.6%) in nonsmoking miners. Employment in surface mining was not likely to cause either the development of CWP or clinically significant respiratory impairment.  相似文献   

19.
Analysis of airflow in the terminal portion of the maximal expiratory flow volume curve has been suggested as a useful test for the early diagnosis of chronic airways obstruction. Whether such an analysis can identify early disease, and whether any subsequent action can prevent the progress of chronic airways obstruction, is unknown and will require prospective studies. As a precursor of such a study we have tried to establish the intrasubject variability of those tests of forced expiration which may be used for screening. We therefore measured expiratory flow volume curves of five healthy males and five healthy females aged 20-30 years as this is an age-group in which early detection of airways obstruction may be of value. Flow volume curves were obtained on the same day of the week for six weeks, and on three separate days during this period we carried out three flow volume curves every hour from 9 am to 6 pm. The data were subjected to analysis of variance to determine the variability of each measurement. Data were collected from forced expired volume in one second (FEV1) forced vital capacity (FVC), maximum expiratory flow rates at 50% and 75% of expired vital capacity, and forced expiratory time (FET). The results showed no consistent pattern of diurnal variation over the working day. The variation in any subject for FEV1 and FVC over the study period was considerably less than variations detected in the maximal expiratory flow rates at 50% and 75% of the expired vital capacity and FET. Our results suggest that the intrasubject variation found in flow rates of the terminal portion of the maximal expiratory flow volume curve and forced expiratory time may limit the usefulness of these tests in detecting early airways obstruction. FEV1 and FVC are more reproducible tests and are therefore particularly suited for cross-sectional screening. The more sensitive maximal expiratory flow volume curve may, however, be more useful for long-term studies in individuals when the onset of disease is sought, or for short-term challenge studies requiring the most sensitive index of change in airway characteristics.  相似文献   

20.
We conducted a longitudinal study to determine the annual rate decline in pulmonary function measurements in male swine confinement workers. For comparison, a grain farming group and a nonfarming rural-dwelling control group were also chosen for the longitudinal study. Two hundred seventeen swine confinement workers, 218 grain farmers, and 179 nonfarming control subjects had valid pulmonary function measurements at the baseline observation conducted in 1990 to 1991 and at the second observation conducted in 1994 to 1995. The swine confinement workers were younger (mean age=38.3+/-11.7 [SD] years) than the nonfarming control subjects (42.6+/-10.4 years) and the grain farmers (44.5+/-11.9 years). When stratified by age, nonfarming control subjects had the lowest mean annual rate decline in FEV1 and FVC in all age categories. The swine confinement workers had the largest annual rate decline in FEV1 and FVC, and this was most obvious in the middle age categories. After controlling for age, height, smoking, and baseline pulmonary function, swine confinement workers had excess annual decline of 26.1 mL in FEV1 (p=0.0005), 33.5 mL in FVC (p=0.0002), and 42.0 mL/s in forced expiratory flow between 25% and 75% of FVC (FEF[25-75%]) (p=0.02) over nonfarming control subjects. Grain farmers had excess annual decline of 16.4 mL in FEV1 (p=0.03), 26.7 mL in FVC (p=0.002), and 11.2 mL/s in FEF(25-75%) (p=0.38) over control subjects. These findings suggest that workers engaged in the swine industry and grain farmers appear prone to accelerated yearly losses in lung function and may therefore be at risk for the future development of chronic airflow limitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号