首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A gas-gap type thermal switch is developed to reduce the initial cool-down time of cryogen free magnets. The switch is a closed cylinder that contains several pairs of axial fins in staggered array and is filled with a gas. The switch connects the first and the second stages of a two-stage cryocooler (ON state) to take advantage of the large refrigeration capacity at the first stage. At cryogenic temperatures, however, the thermal isolation (OFF state) can be achieved without any external actuation, because the gas is frosted and the corresponding vapor pressure is significantly decreased. A detailed heat transfer analysis that takes into account the phase change, the gas convection in continuum or molecular state, and the axial conduction in the fins is presented. Based upon the analysis, a new configuration for the switch is proposed the transfers more heat during ON state and less heat during OFF state compared to the conventional structure. The two switches are fabricated and tested with a two-stage Gifford–McMahon cooler. The experiment shows that the newly developed gas-gap switch achieves a superior thermal performance.  相似文献   

2.
When a quench occurs in a superconducting magnet, excessive joule heating may damage the magnet. We have presented the quench protection system based on an active power method. Our previous quench protection tests have been carried out for small superconducting magnets whose self inductances are less than several hundred mH to verify principles of our proposed system. In this paper, we present experimental results of quench protection tests of a cryocooler cooled 6 T NbTi superconducting magnet (self inductance 15.5 H), which is a commercial size magnet made by Tamakawa Co., Ltd. We confirmed that our proposed system could inhibit the maximum temperature of the superconducting magnet (initial temperature 4.3 K) after the quench to less than about 44 K at operation magnetic field 5.5 T. Experimental results suggest that our proposed system is useful for practical used superconducting magnets.  相似文献   

3.
A two-stage pulse-tube cryocooler driven by a linear compressor was designed, manufactured and tested. The compressor is a moving-magnet type and dual-opposed-piston configuration, in which a plate spring is used. The two-stage cold head is a gas-separating thermal-link configuration. The phase shifter of each stage of the cryocooler can be double-inlet or inertance-tube type. Experiments have been carried out. The linear compressor can provide a pressure ratio of 1.3-1.5. Under the conditions of 1.2 MPa charging pressure and 32 Hz frequency, the second stage of the cryocooler reached a lowest temperature of 14.2 K, and the corresponding cooling temperature of the first stage is 93.3 K.  相似文献   

4.
E.S. Otabe  M. Kiuchi  K. Fujino  B. Ni 《低温学》2009,49(6):267-270
A practical Bi-2223 superconducting magnet, working in liquid nitrogen (L.N2), was designed and fabricated. Bi-2223 tape with a critical current of 147 A was prepared by a controlled overpressure (CT-OP) process at 77.3 K in self-field. Ten double-pancake coils were resistively connected by copper terminals. The bore diameter was 54 mm?, the magnet outer diameter was 122 mm?, the height of the magnet was 124 mm, and the weight of the magnet was about 3 kg. The maximum magnetic field at the center of the bore was 0.48 T with an operating current of 50 A. The experimental results agree well with design predictions calculated by finite element method. AC operation was also performed, and no distortion of the voltage waveform was observed. Therefore, this Bi-2223 superconducting magnet is a suitable replacement for copper magnets designed for applications in science and technology.  相似文献   

5.
Future space missions will include detectors and other components cooled to cryogenic temperatures by adiabatic demagnetization refrigerators (ADRs) coupled with mechanical cryocoolers. In such systems the ADRs require lightweight, low-current superconducting magnets. At least one of an ADR’s magnets must operate at the cryocooler’s coldest stage temperature. This temperature should be as high as possible in order to improve operating efficiency and design flexibility. We previously reported the development of a lightweight (1 kg) low-current (8 A) Nb3Sn magnet which produces a 3 T central field at 10 K. We now report our progress in developing a new 10 K magnet of similar size made with smaller diameter Nb3Sn wire which will produce a 4 T central field with approximately 5 A.  相似文献   

6.
Potential performance advantages of a solid nitrogen cooled “permanent” high-temperature superconducting (SN2/HTS) magnet system over a liquid helium cooled low-temperature superconducting (LHe/LTS) system are explored. The SN2/HTS system design includes a second solid heat capacitor that cools a radiation shield. Recooling of the heat capacitors is performed with a demountable cryocooler. The SN2/HTS system offers both enhanced stability and improved portability over a LHe/LTS system.Design codes are constructed to compare the SN2/HTS system design with a LHe/LTS design for a general permanent superconducting magnet system employing a room temperature bore. The codes predict the system volume and mass that should be expected for a given set of design requirements, i.e. field strength and bore size, and a given set of conductor properties. The results indicate that present HTS conductor critical current and index are not yet sufficient for producing SN2/HTS systems of a size that is comparable with that expected for a LHe/LTS system; however, the conductor properties of Bi2223/Ag have been consistently improving, and new HTS conductors are expected to be developed in the near future. The codes are used to determine the minimum Bi2223/Ag conductor performance required for a SN2/HTS system to be competitive with a LHe/LTS system.  相似文献   

7.
35 K双级斯特林制冷机性能实验   总被引:1,自引:1,他引:1  
介绍了一台双级斯特林制冷机性能及运行参数对制冷机性能的影响。实验结果表明,在充气压力1MPa,运行频率40Hz,位移相位角65°的条件下,压缩机输入功率56W时,可获得0.85W@35K的制冷量。通过实验发现:同样功耗下,随着位移相位角减小,二级制冷温度下降,一级温度制冷温度上升。这表明,位移相位角对双级间的冷量分配有影响,可以通过相位控制对一、二级之间的冷量分配进行调整。  相似文献   

8.
Chao Wang 《低温学》2008,48(3-4):154-159
This paper introduces intermediate cooling by thermally attaching heat exchangers on the second stage pulse tube and regenerator in a commercial 4 K pulse tube cryocooler. Due to the large enthalpy flow in the 2nd stage pulse tube and regenerator, both intermediate heat exchangers on the pulse tube and regenerator can provide cooling capacities in the temperature range of 5–15 K without or with minor effect on the performance of the 4 K stage. Extracting cooling capacity from the pulse tube or regenerator reduces the 1st stage cooling performance in the present study. The joint intermediate heat exchanger on the pulse tube and regenerator has demonstrated promising results for applications.  相似文献   

9.
A Stirling-type in-line pulse tube cryocooler (PTC) has been designed, built and tested at Shanghai Institute of Technical Physics (SITP), Chinese Academy of Sciences. This PTC prototype can obtain a low-noise cooling capacity of more than 10 W at around 90 K cold head temperature and is used for cooling a space-borne infrared photo detector. In order to achieve a highly efficient PTC, a simplified numerical simulation model has been established for design and optimization. The simulation results of the regenerator, pulse tube and inertance tube are analyzed in detail. Besides, some key parameters of the PTC are listed in the paper. The PTC’s performances are tested at different operating frequencies from 42 Hz to 55 Hz and its reject temperature dependence is observed in the range of 290 K to 320 K. Furthermore, the map of the PTC’s performance characteristics is presented.  相似文献   

10.
11.
The Vuilleumier (VM) refrigerator, known as heat driven refrigerator, is one kind of closed-cycle Stirling type regenerative refrigerator. The VM refrigerator with power being supplied by liquid nitrogen was proposed by Hogen and developed by Zhou, which shows great potential for development below 10 K. This paper describes the experimental development of a VM cryocooler operating below 8 K, which was achieved by using liquid nitrogen as a heat sink of middle cavity. The regenerator was optimized by using a part of metallic magnetic regenerator material Er3Ni to replace the lead sphere and a no-load temperature of 7.8 K was obtained. Then all the lead spheres were replaced by Er0.6Pr0.4 material and a no-load temperature of 7.35 K was obtained, which is the lowest temperature for this kind of refrigerator reported so far. The cooling power at 10 K is about 500 mW with a pressure ratio near 1.6 and a charge pressure of 1.8 MPa. Especially, the magnetic material Er0.6Pr0.4 was found to be a potential substitution for the conventional lead.  相似文献   

12.
A Stirling pulse tube cryocooler (SPTC) operating at the liquid-helium temperatures represents an excellent prospect for satisfying the requirements of space applications because of its compactness, high efficiency and reliability. However, the working mechanism of a 4 K SPTC is more complicated than that of the Gifford McMahon (GM) PTC that operates at the relatively low frequency of 1–2 Hz, and has not yet been well understood. In this study, the primary operating parameters, including frequency, charge pressure, input power and precooling temperature, are systematically investigated in a home-developed separate three-stage SPTC. The investigation demonstrates that the frequency and precooling temperature are closely coupled via phase shift. In order to improve the cooling capacity it is important to lower the frequency and the precooling temperature simultaneously. In contrast to the behavior predicted by previous studies, the pressure dependence of the gas properties results in an optimized pressure that decreases significantly as the temperature is lowered. The third stage reaches a lowest temperature of 4.97 K at 29.9 Hz and 0.91 MPa. A cooling power of 25 mW is measured at 6.0 K. The precooling temperature is 23.7 K and the input power is 100 W.  相似文献   

13.
A single-stage high frequency multi-bypass coaxial pulse tube cryocooler (PTC) has been developed for physical experiments. The performance characteristics are presented. At present, the cooler has reached the lowest temperature of 18.6 K with an electric input power of 268 W, which is the reported lowest temperature for single-stage high frequency PTC. The cooler typically provides 0.2 W at 20.6 K and 0.5 W at 24.1 K with the input power of 260 W at 300 K ambient temperature. The cooperation phase adjustment method of multi-bypass and double-inlet shows its advantages in experiments, they might be the best way to get temperature below 20 K for single-stage high frequency PTC. The temperature stability of the developed PTC is also observed.  相似文献   

14.
High cooling capacity Stirling cryocooler generally has hundreds to thousands watts of cooling power at liquid nitrogen temperature. It is promising in boil-off gas (BOG) recondensation and high temperature superconducting (HTS) applications. A high cooling capacity Stirling cryocooler driven by a crank-rod mechanism was developed and studied systematically. The pressure and frequency characteristics of the cryocooler, the heat rejection from the ambient heat exchanger, and the cooling performance are studied under different charging pressure. Energy conversion and distribution in the cryocooler are analyzed theoretically. With an electric input power of 10.9 kW and a rotating speed of 1450 r/min of the motor, a cooling power of 700 W at 77 K and a relative Carnot efficiency of 18.2% of the cryocooler have been achieved in the present study, and the corresponding pressure ratio in the compression space reaches 2.46.  相似文献   

15.
This paper describes helium liquefaction using a commercial cryocooler with 1.5 W cooling power at 4.2 K (Sumitomo model RDK415D with compressor CSW-71D, consuming 6.5 kW electrical power), equipped with heat exchangers for precooling the incoming gas. No additional cooling power of cryoliquids or additional Joule-Thomson stages were utilized. Measurements of the pressure dependence of the liquefaction rate were performed. A maximum value of 83.9 g/h was obtained for 2.25 bar stabilized input pressure. Including the time needed to cool the liquefied helium to 4.2 K at 1 bar after filling the bottle connected to the cold head, and correcting for heat screen influences, this results in a net liquefaction rate of 67.7 g/h. Maintaining a pressure close to 1 bar above the bath during liquefaction, a rate of 55.7 g/h was obtained. The simple design enables many applications of the apparatus.  相似文献   

16.
He-3 is generally recognized for its ability to provide more excellent thermophysical performance than He-4, especially in the 4 K temperature range. However, this was not always the case in our preliminary experiments on a three-stage Stirling-type pulse tube cryocooler (SPTC). Our ongoing studies, as reported in this paper, demonstrate that the different working fluids also affect the performance through their phase shifting capability. This feature has been passed over in large part by researchers considering refrigerant substitution. Unlike previous theoretical analyses that focus primarily on regenerator losses, this report investigates the effects of the working fluid on the phase angle at the cold end in order to quantitatively reveal the relationship between the lowest attainable temperature and the cooling capacity. The analysis agrees well with our experimental results on a three-stage SPTC. While running with the operating parameters optimized for He-3, the lowest temperature of the SPTC decreased from 5.4 K down to 4.03 K. This is the lowest refrigeration temperature ever achieved with a three-stage SPTC.  相似文献   

17.
斯特林型两级脉管制冷机的研制   总被引:2,自引:2,他引:0  
介绍了斯特林型两级脉管制冷机的研发过程,设计并制造了1台采用对置的动磁式直线压缩机驱动的两级脉管制冷机.对制冷机系统进行了初步的试运行,试验表明直线压缩机可以正常工作,在充气压力1.6MPa、工作频率30Hz、输入电功率220W时,产生1.3左右的压比,由该压机驱动的二级脉管制冷机,第一级和第二级分别获得124K和45K的低温.  相似文献   

18.
L.W. Yang  G. Thummes 《低温学》2005,45(2):155-159
High frequency (30-50 Hz) multi-stage pulse tube coolers that are capable of reaching temperatures close to 20 K or even lower are a subject of recent research and development activities. This paper reports on the design and test of a two-stage pulse tube cooler which is driven by a linear compressor with nominal input power of 200 W at an operating frequency of 30-45 Hz. A parallel configuration of the two pulse tubes is used with the warm ends of the pulse tubes located at ambient temperature. For both stages, the regenerator matrix consists of a stack of stainless steel screen. At an operating frequency of 35 Hz and with the first stage at 73 K a lowest stationary temperature of 19.6 K has been achieved at the second stage. The effects of input power, frequency, average pressure, and cold head orientation on the cooling performance are also reported. An even lower no-load temperature can be expected from the use of lead or other regenerator materials of high heat capacity in the second stage.  相似文献   

19.
We present a two-stage pulse tube cryocooler working at 300 Hz driven by a thermoacoustic engine. Compared to the previous experimental results, the combined inertance tube with different diameters that is used in the second stage is found to play the key role in phase shifting and to lead to superior cooling. Two different wall thickness tubes are tested in the experiments. After the optimization, the second-stage cold end achieves a no-load temperature of 57.9 K with an average pressure of 3.8 MPa, and a cooling capacity of 0.5 W at 81.88 K.  相似文献   

20.
Chao Wang 《低温学》2005,45(12):719-724
This paper introduces helium recondensing in a 4000 l dewar using a 4 K pulse tube cryocooler at Amundsen-Scott research station at the South Pole. The helium dewar has a normal boil-off rate of 14 l/day. Two features of cooling the dewar neck by helium vapor and precooling helium gas to be liquefied ensured high efficiency of the pulse tube recondenser in this application. The liquefier/recondenser has being successfully operating in the dewar at South Pole station since February 2005. It not only maintains zero boil-off of the dewar, but also liquefies helium gas supplied from outside of the dewar with a rate around 2.7 l/day.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号