共查询到20条相似文献,搜索用时 515 毫秒
1.
电化学方法应用于电力设备腐蚀与防护的研究 总被引:3,自引:0,他引:3
从双水内冷发电机空芯铜导线的腐蚀行为研究,电厂凝汽器铜管耐蚀性的评定以及热力设备停用保护用十八烷基胺的成膜研究等方面介绍了电化学方法在电力设备腐蚀与 也护研究中的应用。 相似文献
2.
防止铜合金热交换器腐蚀的技术改进 总被引:1,自引:0,他引:1
本文通过硫酸亚铁防止铜或铜合金腐蚀工艺的深入研究,针对硫酸亚铁遣膜技术在应用过程中存在的问题进行了技术改进,详细阐述了利用硫酸亚铁复合新工艺对电站汽轮机凝汽器铜管进行成膜保护的成效,以及所产生的经济效益和社会效益。 相似文献
3.
通过宏观检查、化学成分分析、微观形貌观察和能谱分析等手段对某化肥厂凝汽器管束泄漏的原因进行了分析。结果表明:管束发生了垢下氯离子点蚀,并因化学清洗药品中含氟离子,经过清洗-吹扫-开车过程的两个停工期,在自然蒸发作用下氯离子和氟离子发生聚集浓缩,点蚀加剧,造成腐蚀穿孔。 相似文献
4.
5.
6.
凝汽器铜管经FeSO4处理后耐蚀性的电化学评定 总被引:5,自引:2,他引:5
用多种电化学方法对合肥发电厂经FeSO4成膜处理后凝汽器铜管的耐蚀性进行评定,测试结果表明,经FeSO4补膜11个月试样的耐蚀性优于一次性成膜试样,后者的耐蚀性又成于膜试样。交流阻抗和恒电位阶跃方法是评价凝汽器铜管FeSO4处理效果的有效方法。 相似文献
7.
8.
9.
10.
11.
本文针对某公司丁二烯装置冷凝器E-203A的严重腐蚀情况,对冷凝器清洗使用的水质进行了分析和腐蚀性评价、对冷凝器管束外垢样进行了分析并对现场循环冷却水系统的清洗预膜效果进行了监测,根据分析和监测结果,深入地分析了冷凝器E-203A的腐蚀原因. 相似文献
12.
When sea water was used as cooling water for water condenser of nuclear power plants, commercial stainless steels can not be applied because chloride concentration exceeds 20,000 ppm. There are many opinions for the materials selection of tube and tube sheets of a condenser. This work reviewed the application guide line of stainless steels for sea-water facilities and the estimation equations of lifespan were proposed from the analyses of both field data for sea water condenser and experimental results of corrosion. Empirical equations for lifespan estimation were derived from the pit initiation time and re-tubing time of stainless steel tubing in sea water condenser of nuclear power plants. The lifespan of seal-welded super austenitic stainless steel tube/tube sheet was calculated from these equations. Critical pitting temperature of seal-welded PRE 50 grade super stainless steel was evaluated as 60 °C. Using the proposed equation in engineering aspect, tube pitting corrosion time of seal-welded tube/tube sheet was calculated as 69.8 years and re-tubing time was estimated as 82.0 years. 相似文献
13.
《腐蚀工程科学与技术》2013,48(6):264-269
AbstractThis paper describes pitting corrosion that has occurred in the condenser tubes in a numbu of power stations in the Republic of South Africa. The power stations concerned are situated inland and use fresh surface water, concentrated in cooling towers, for condenser cooling. Investigations indicate that the corrosion is similar to the pitting of copper potable water tubes caused in the U.K. and elsewhere by the presence of carbon film formed on the surface during tube manufacture. Many turbine and condenser tube manufacturers, however, disagree with these findings and some of their views are given in this paper. The author is of the opinion that accelerated corrosion due to this cause is more general than most corrosion engineers believe. 相似文献
14.
15.
通过对天津石化分公司某石化厂循环水冷凝器管束腐蚀部位检查,腐蚀部位的垢样组成,循环水中微生物分析等项目测试分析,对该厂循环水冷凝器管束腐蚀穿孔原因进行了分析,并提出了有针对性的腐蚀控制建议. 相似文献
16.
分析了铜及合金在火力电厂凝汽器、发电机冷却水系统等换热设备的应用前景。指出了铜材质在凝汽器的使用中存在铜管的选材及安装不当、使用管理不到位及停运腐蚀等问题,提出了合理选材、加强水质控制和处理、做好停运保护等解决办法。对实际运行中有较好的指导作用。 相似文献
17.
白铜盘管拉伸在国内属冷凝管生产新型工艺技术,在不增加设备投资的条件下,利用原有紫铜盘管生产线,通过水封挤压、大加工率轧制、拉伸等工艺控制技术,不需要中间退火,就可实现白铜盘管的拉伸,改变了白铜冷凝管生产需要多次中间退火的传统认识,在当前铜加工材市场低迷的状况下,为扩大产品品种,形成新的经济增长点提供了新的思路。本文通过对C70600挤压、轧制、盘拉、退火工艺试验的研制、分析、讨论,介绍了白铜盘管生产的工艺特点。 相似文献
18.
仪化热电厂将循环水用作冲灰水,导致浓缩倍率只有1.6以及凝汽器铜管腐蚀结垢严重。针对此问题,提出了隔断循环水与冲灰水的直接联系,将循环水系统改为闭路循环,对凝汽器铜管进行酸洗,向循环水中添加缓蚀阻垢剂、杀菌灭藻剂和增设旁流过滤系统等办法。全部措施实施后热电厂获得了很好的经济效益。 相似文献
19.
徐州发电厂凝汽器的腐蚀与防护 总被引:3,自引:0,他引:3
凝汽器的腐蚀泄漏严重影响机组的水汽品质,威胁机组的安全经济运行,徐州发电厂通过及时检查和涡流探伤掌握铜管腐蚀情况。采用加强循环冷却水的加药管理,保持铜管清洁,管板刷漆联合阴极保护,FeSO4镀膜等防护措施,在凝汽器腐蚀治理方面取得一定的效果。 相似文献