首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This work is to study the effect of properties of gas diffusion layer (GDL) on performance in a polymer electrolyte membrane fuel cell (PEMFC) by both numerical simulation and experiments. The 1-dimension numerical simulation using the mixture-phase model is developed to calculate polarization curve. We are able to estimate optimum GDL properties for cell performance from numerical simulation results. Various GDLs which have different properties are prepared to verify accuracy of the simulation results. The contact angle and gas permeability of GDLs are controlled by polytetrafluoroethylene (PTFE) content in micro-porous layers (MPLs). MPL slurry is prepared by homogeneous blending of carbon powder, PTFE suspension, isopropyl alcohol and glycerol. Then the slurry is coated on gas diffusion mediums (GDMs) surface with controlled thickness by blade coating method. Non-woven carbon papers which have different thicknesses of 200 μm and 380 μm are used as GDMs. The prepared GDLs are measured by surface morphology, contact angle, gas permeability and through-plane electrical resistance. Moreover, the GDLs are tested in a 25 cm2 single cell at 70 °C in humidified H2/air condition. The contact angle of GDL increases with increasing PTFE content in MPL. However, the gas permeability and through-plane electrical conductivity decrease with increasing PTFE content and thickness of GDM. These changes in properties of GDL greatly influence the cell performance. As a result, the best performance is obtained by GDL consists of 200 μm thick non-woven carbon paper as GDM and MPL contained 20 wt.% PTFE content.  相似文献   

2.
The gas diffusion layer (GDL) is composed of a substrate and a micro-porous layer (MPL), and is treated with polytetrafluoroethylene (PTFE) to promote water discharge. Additionally, the MPL mainly consists of carbon black and PTFE. In other words, the optimal design of these elements has a dominant effect on the polymer electrolyte membrane fuel cell (PEMFC) performance. For the GDL, it is crucial to prevent water flooding, and the water flux within the GDL is strongly affected by the capillary pressure gradient. In this study, the PEMFC performance was systematically investigated by varying the substrate PTFE content, MPL PTFE content, and MPL carbon loading per unit area. The effects of each experimental variable on the PEMFC performance and especially on the capillary pressure gradient were quantitatively analyzed when the GDLs were manufactured by the doctor blade manufacturing method. The experimental results indicated that as the PTFE content of the anode and cathode GDL increased, the PEMFC performance deteriorated due to the deformation of the porosity and tortuosity of the GDL. Additionally, the PEMFC performance improved as the MPL PTFE content of the cathode GDL increased at low relative humidity (RH), but the PEMFC performance tendency was reversed at high RH. Further, the MPL carbon loading of 2 mg/cm2 demonstrated the best performance, and the advantages and disadvantages of the MPL carbon loading were identified. In addition, the effects of each experimental variable on liquid water, water vapor, and gas permeability were investigated.  相似文献   

3.
The effects of the parameters of the anode gas diffusion layer (GDL), including the PTFE content in the backing layer (BL), the PTFE content in the microporous layer (MPL), and the carbon black loading on the performance of a liquid‐feed direct dimethyl ether fuel cell (DDFC), were experimentally investigated. The results indicated that increase in the PTFE content can produce more cracks across the whole surface of the MPL. These cracks were benefit to the anode two‐phase mass transport. The optimal PTFE content in anode BL and MPL was 18 and 40 wt%, respectively. The performances of the DDFCs tended to decline with the increase in the carbon black loading in the anode GDLs due to the difficult long path of mass transport. The maximum power density was obtained with 18 wt% PTFE in BL and 0 mg cm?2 carbon black loading, the optimal result, was 76.6 mW cm?2 at ambient pressure. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
This work investigates the degradation of an individual gas diffusion layer (GDL) by repeated freezing cycles. The pore size distribution, gas permeability, surface structure, and contact angle on the surface of the GDL were measured in four different types of GDL: SGL paper with a microporous layer (MPL); SGL paper with 5 wt% of polytetrafluoroethylene (PTFE) loading; Toray paper without PTFE loading; and Toray paper with 20 wt% of PTFE loading. After repeated freezing cycles, the porosity of the GDL without PTFE was reduced by 27.2% due to the volumetric expansion of the GDL. The peak of the log differential intrusion moved toward a smaller pore diameter slightly because of the repeated freezing process. The crack of the MPL increased in its width and length after repeated freezing cycles. The through-plane gas permeability of the GDL with the MPL doubled after repeated freezing cycles due to the growth of the crack in the MPL, but was very small for the GDLs with Toray paper. Besides, the GDLs with PTFE loading showed a relatively larger decrease in the contact angle on the surface than the GDL without PTFE loading due to the separation of PTFE from the carbon fiber during the repeated freezing process.  相似文献   

5.
Knowledge of the absolute permeability for the various porous layers is necessary to obtain accurate profiles for water saturation within the membrane electrode assembly (MEA) in a two-phase model of a polymer electrolyte membrane fuel cell (PEMFC). In this paper, the gas permeability of gas diffusion layers (GDLs) coated with microporous layers (MPLs) of various carbon loadings for two different carbon blacks have been experimentally measured. The permeability of the GDL was found to decrease by at least one order of magnitude after the MPL-coating. Also, the permeability of the MPLs was shown to be lower than that of the carbon substrate by 2–3 orders of magnitude. Further, it was found that the gas permeability of the MPLs changes significantly from one carbon loading to another despite the use of a single weight composition for all the MPLs coated, namely 20% PTFE and 80% carbon black. This signifies the possible inaccuracy in estimating the MPL permeability through employing the cross-section SEM images as they do not resolve the MPL penetration into the carbon substrate. Finally, the MPL sintering was found to slightly decrease the permeability of the GDL.  相似文献   

6.
A new method of preparing microporous layer (MPL) for proton exchange membrane fuel cell (PEMFC) was presented in this paper. Considering the bad dispersion of PTFE aqueous suspension in the carbon slurry based on ethanol, polyvinylpyrrolidone (PVP) aqueous solution was used to prepare carbon slurry for microporous layer. The prepared gas diffusion layers (GDLs) were characterized by scanning electron microscopy, contact angle system and pore size distribution analyzer. It was found that the GDL prepared with PVP aqueous solution had higher gas permeability, as well as more homogeneous hydrophobicity. Moreover, the prepared GDLs were used in the cathode of fuel cell and evaluated with fuel cell performance and EIS analysis, and the GDL prepared with PVP aqueous solution indicated better fuel cell performance and lower ohmic resistance and mass transfer resistance.  相似文献   

7.
The purpose of this study is to investigate the effect of ploytetrafluoroethylene (PTFE)-treatment and microporous layer (MPL)-coating on the electrical conductivity of gas diffusion layers (GDLs), as used in proton exchange membrane fuel cells (PEMFCs). The results show that, for PTFE-treated GDLs, the electrical conductivity in orthogonal in-plane directions is almost invariant with the PTFE loading. On the other hand, the in-plane conductivity of the MPL-coated GDL SGL 10BE (50% PTFE) was found to be higher than that of the counterpart SGL 10BC (25% PTFE) and this was explained by the presence of more conductive carbon particles in the MPL of SGL 10BE. Further, the conductivity of each GDL sample was measured in two perpendicular in-plane directions in order to investigate the in-plane anisotropy. The results show that the electrical conductivity of the GDL sample in one direction is different to that in the other direction by a factor of about two. The contact resistance, the main factor affecting the through-plane conductivity, of PTFE-treated GDLs shows a different trend to the corresponding in-plane conductivity, namely it increases as the PTFE loading increases. On the other hand, the contact resistance of the MPL-coated GDL SGL 10BE (50% PTFE) was found to be lower than that of the counterpart SGL 10BC (25% PTFE) and again this was explained by the presence of more conductive carbon particles in the MPL of SGL 10BE. Also, it was noted that the MPL coating appears to have a positive effect in reducing the contact resistance between the GDL and the bipolar plate. This is most likely due to the compressibility of the MPL layers that allows them to fill in the ‘gaps’ that exist in the surface of the bipolar plates and therefore establishes a good contact between the latter plates and the GDLs. Finally, good curve fitting of the contact resistance as a function of the clamping pressure has been achieved.  相似文献   

8.
Anode water removal (AWR) is studied as a diagnostic tool to assess cathode gas diffusion layer (GDL) flooding in PEM fuel cells. This method uses a dry hydrogen stream to remove product water from the cathode, showing ideal fuel cell performance in the absence of GDL mass transfer limitations related to water. When cathode GDL flooding is limiting, the cell voltage increases as the hydrogen stoichiometry is increased. Several cathode GDLs were studied to determine the effect of microporous layer (MPL) and PTFE coating. The largest voltage gains occur with the use of cathode GDLs without an MPL since these GDLs are prone to higher liquid water saturation. Multiple GDLs are studied on the cathode side to exacerbate GDL flooding conditions to further confirm the mechanism of the AWR process. Increased temperature and lower cathode RH allow for greater overall water removal so the voltage improvement occurs faster, though this leads to quicker membrane dehydration.  相似文献   

9.
The in-plane permeability has been experimentally estimated for a number of carbon substrates and microporous layer (MPL)-coated gas diffusion layers (GDLs) as used in proton exchange membrane (PEM) fuel cells. The results show that the in-plane permeability of the tested carbon substrates decreases with increasing polytetrafluoroethylene (PTFE) loading and, in contrast, the greater is the PTFE loading in the MPL, the greater is the permeability. It has been shown that the in-plane permeability of the carbon substrates is reduced by an order of magnitude if they are coated with MPLs. Further, the permeability is different from one in-plane principal direction to another by a factor of about two. Finally, ignoring the inertial terms (for the reported flow rates) and the compressibility of the flowing air results in significant errors in the obtained values of the permeability.  相似文献   

10.
Water management in a proton exchange membrane (PEM) fuel cell is one of the critical issues for improving fuel cell performance and durability, and water transport across the gas diffusion layer plays a key role in PEM fuel cell water management. In this work, we investigated the effects of polytetrafluoroethylene (PTFE) content and the application of a micro-porous layer (MPL) in the gas diffusion layer (GDL) on the water transport rate across the GDL. The results show that both PTFE and the MPL play a similar role of restraining water transport. The effects of different carbon loadings in the MPL on water transport were also investigated. The results demonstrate that the higher the carbon loading in the MPL, the more it reduces the water transport rate. Using the given cell hardware and components, the optimized operation conditions can be obtained based on a water balance analysis.  相似文献   

11.
This research investigates the optimal polytetrafluoroethylene (PTFE) content in the cathode gas diffusion layer (GDL) by evaluating the effect of compression on the performance of a proton exchange membrane (PEM) fuel cell. A special test fixture is designed to control the compression ratio, and thus the effect of compression on cell performance can be measured in situ. GDLs with and without a microporous layer (MPL) coating are considered. Electrochemical impedance spectroscopy (EIS) is used to diagnose the variations in ohmic resistance, charge transfer resistance and mass transport resistance with compression ratio. The results show that the optimal PTFE content, at which the maximum peak power density occurs, is about 5 wt% with a compression ratio of 30% for a GDL without an MPL coating. For a GDL with an MPL coating, the optimal PTFE content in the MPL is found to be 30% at a compression ratio of 30%.  相似文献   

12.
The optimal design of the cathode gas diffusion layer (GDL) for direct methanol fuel cells (DMFCs) is not only to attain better cell performance, but also to achieve better water management for the DMFC system. In this work, the effects of both the PTFE loading in the cathode backing layer (BL) as well as in the micro-porous layer (MPL) and the carbon loading in the MPL on both water transport and cell performance were investigated experimentally. The experimental data showed that with the presence of a hydrophobic MPL in the GDL, the water-crossover flux through the membrane decreased slightly with increasing the PTFE loading in the BL. However, a higher PTFE loading in the BL not only lowered cell performance, but also resulted in an unstable discharging process. It was also found that the PTFE loading in the MPL had little effect on the water-crossover flux, but its effect on cell performance was substantial: the 40-wt% PTFE loading in the MPL was found to be the optimal value to achieve the best performance. The experimental results further showed that increasing the carbon loading in the MPL significantly lowered the water-crossover flux, but a too high carbon loading would decrease the cell performance as the result of the increased oxygen transport resistance; the 2.0-mg C cm−2 carbon loading was found to exhibit the best performance.  相似文献   

13.
In this study, Nafion ionomer, as a kind of hyperdispersant, was added to polytetrafluoroethylene (PTFE) water dispersion system to suppress the size of PTFE particles in the ink of microporous layer (MPL). The agglomeration behavior of PTFE in ethanol and MPL were investigated by laser diffraction, dynamic light scattering (DLS) and metallurgical microscopes. The electronic resistance, pore size distribution, gas permeability and surface hydrophobic/hydrophilic properties were also characterized for prepared gas diffusion layers (GDLs). It was shown that PTFE water dispersion system suffered flocculating when dispersed in ethanol and this agglomeration behavior was reduced by employing Nafion ionomer. With the increase in the Nafion ionomer adopted in the MPL, not only the decreased hydrophobic property was shown in the MPL, but the decreased PTFE particle size was also achieved, which results in improved crosslink of carbon and pores themselves as well as the volume loss of pores in micron scale. The increased gas permeability and electronic conductivity of the GDL made the one employing the PTFE dispersion system with 1% Nafion content own its advantages as the cathode diffusion layer for a direct methanol fuel cell (DMFC) under near-ambient conditions.  相似文献   

14.
Polymer electrolyte-based unitized reversible fuel cells (URFCs) combine the functionality of a fuel cell and an electrolyzer in a single device. In a URFC, titanium (Ti)-felt is used as a gas diffusion layer (GDL) of the oxygen electrode, whereas typical carbon paper is used as a GDL of the hydrogen electrode. Different samples of Ti-felt with different structural properties (porosity and fiber diameter) and PTFE content were prepared for use as GDLs of the oxygen electrode, and the relation between the properties of the GDL and the fuel cell performance was examined for both fuel cell and electrolysis operation modes. Experimental results showed that the cell with a Ti-felt GDL of 80 μm fiber diameter had the highest round-trip efficiency due to excellent fuel cell operation under relatively high-humidity conditions despite degradation in performance in the electrolysis mode.  相似文献   

15.
The primary removal of product water in proton exchange membrane (PEM) fuel cells is through the cathode gas diffusion layer (GDL) which necessitates the understanding of vapor and liquid transport of water through porous media. In this investigation, the effect of microporous layer (MPL) coatings, GDL thickness, and polytetrafluorethylene (PTFE) loading on the effective water vapor diffusion coefficient is studied. MRC Grafil, SGL Sigracet, and Toray TGP-H GDL samples are tested experimentally with and without MPL coatings and varying PTFE loadings. A dynamic diffusion test cell is developed to produce a water vapor concentration gradient across the GDL and induce diffusion mass transfer. Tests are conducted at ambient temperature and flow rates of 500, 625, and 750 sccm. MPL coatings and increasing levels of PTFE content introduce significant resistance to diffusion while thickness has negligible effects.  相似文献   

16.
Carbon fiber cloth based on PAN (polyacrylonitrile) material was woven and fabricated into the gas diffusion layer (GDL) for PEMFC applications. This paper describes the newly developed carbon cloth as GDL and proves its feasibility for PEMFC. Such carbon cloth based GDLs have performance equal to that of conventional carbon papers verified using the standard test instrument. The mechanical tests show that as a supporting base, carbon cloth is more practical than carbon paper because of its superior compressibility, elasticity, and flexibility performance, making it more appropriate for ongoing manufacturing and assembly processes. Furthermore, even though carbon paper is structurally flatter and smoother than carbon cloth, the discharge curves of both substrates coated with a MPL (micro-porous layer) showed similar current density (around 750 mA/cm2) at 0.6 V. This indicates that the developed carbon cloth with MPL has achieved the required performance and provides an alternative selection from carbon paper as GDL.  相似文献   

17.
The passive operation of a direct methanol fuel cell with neat methanol requires the water that is produced at the cathode to diffuse through the membrane to the anode to compensate the methanol oxidation reaction (MOR). Hence, the anode performance of this type of fuel cell can be limited by the water transport rate from the cathode to the anode. In this work we theoretically show that the water transport from the cathode to the anode depends primarily on the design of the cathode gas diffusion layer (GDL). We investigate experimentally the effects of the design parameters of the cathode GDL, including the PTFE (polytetrafluoroethylene) content in the backing layer (BL), and the carbon loading and the PTFE content in the microporous layer (MPL) on the water transport and the performance of the passive DMFC with the help of a reference electrode. The results indicate that on one hand, these parameters can be adjusted to decrease the water concentration loss of the anode performance, but on the other hand, they can also cause an increase in the oxygen concentration loss of the cathode performance. Hence, an optimal balance in minimizing the both concentration losses is the key to maximize the cell performance.  相似文献   

18.
The effects of the design parameters of the anode diffusion layer (DL), including the PTFE loading in the backing layer (BL), and the carbon and PTFE loading in the microporous layer (MPL), on water transport through the membrane and the performance of a liquid-feed direct methanol fuel cell (DMFC) are experimentally investigated. The results indicate that increasing the PTFE loading in the BL and introducing a MPL could decrease water crossover through the membrane without sacrificing cell performance when the feed methanol concentration is increased. It is also found that changing the PTFE loading in the MPL has little effect on water crossover, whereas increasing the carbon loading in the MPL could noticeably decrease the water-crossover flux. Nevertheless, the ability of the MPL to reduce water crossover is limited by the presence of a number of mud cracks. To reduce further the water-crossover flux, a crack-free MPL made of multi-walled carbon nanotubes (MWCNTs) and PTFE is proposed. Tests indicate that the DMFC with the nanotube MPL results in a much lower water-crossover flux than a conventional carbon-powder MPL. More importantly, the use of the nanotube MPL allows the DMFC to be operated with a higher methanol concentration, and thereby increases the fuel cell system energy density.  相似文献   

19.
The clamping pressure of polymer electrolyte membrane fuel cells for vehicle applications should be typically high enough to minimize contact resistance. However, an excessive compression pressure may cause a durability problem. In this study, the effects of gas diffusion layer (GDL) structure on the open circuit voltage (OCV) and hydrogen crossover have been closely examined. Results show that the performances of fuel cells with GDL-1 (a carbon fiber felt substrate with MPL having rough surface) and GDL-3 (a carbon fiber paper substrate with MPL having smooth surface) are higher than that with GDL-2 (a carbon fiber felt substrate with MPL having smooth surface) under low clamping torque conditions, whereas when clamping torque is high, the GDL-1 sample shows the largest decrease in cell performance. Hydrogen crossover for all GDL samples increases with the increase of clamping torque, especially the degree of increase of GDL-1 is much greater than that of the other two GDL samples. The OCV reduction of GDL-1 is much greater than that of GDL-2 and GDL-3. It is concluded that the GDL-3 is better than the other two GDLs in terms of fuel cell durability, because the GDL-3 shows the minimum OCV reduction.  相似文献   

20.
Past studies have shown that both the substrate and microporous layer of the gas diffusion layer (GDL) significantly affect water balance and performance of a proton exchange membrane (PEM) fuel cell. However, little effort has been made to investigate the importance of GDL properties on the durability of PEM fuel cells. In this study, the in situ degradation behaviour of a commercial GDL carbon fiber paper with MPL was investigated under a combination of elevated temperature and elevated flow rate conditions. To avoid the possible impact of the catalyst layer during degradation test, different barriers without catalyst were utilized individually to isolate the anode and cathode GDLs. Three different barriers were evaluated on their ability to isolate GDL degradation and their similarity to a fuel cell environment, and finally a novel Nafion/MPL/polyimide barrier was chosen. Characterization of the degraded GDL samples was conducted through the use of various diagnostic methods, including through-plane electrical resistivity measurements, mercury porosimetry, relative humidity sensitivity, and single-cell performance curves. Noticeable decreases in electrical resistivity and the hydrophobic properties were detected for the degraded GDL samples. The experimental results suggested that material loss plays an important role in GDL degradation mechanisms, while excessive mechanical stress prior to degradation weakens the GDL structure and changes its physical property, which consequently accelerates the material loss of the GDL during aging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号