首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper a review of solar cooling and refrigeration technologies is presented. A discussion on the main reasons why these technologies are not presently economically feasible is carried out. and two installations in Mexico are analysed.  相似文献   

2.
A solar‐assisted absorption cooling and water heating system model is adjusted and experimentally validated in this study. Conservation laws are combined with available heat and mass transfer empirical correlations to quantify the diverse types of flows that cross the system. The model is generalized by nondimensionalizing the variables, and the resulting system of ordinary differential equations is solved for dimensionless temperatures with respect to time. Next, the model is experimentally adjusted through the solution of the inverse problem of parameter estimation, through which geometric, operating parameters and physical terms are identified and adjusted (or added) according to a first set of measured temperature data. The adjusted model is then validated using a second experimental data set, and the results are presented in normalized form for design, control, and optimization of similar systems.  相似文献   

3.
Analytical and experimental studies were performed on a direct‐expansion solar‐assisted heat pump (DX‐SAHP) water heating system, in which a 2 m2 bare flat collector acts as a source as well as an evaporator for the refrigerant. A simulation model was developed to predict the long‐term thermal performance of the system approximately. The monthly averaged COP was found to vary between 4 and 6, while the collector efficiency ranged from 40 to 60%. The simulated results were used to obtain an optimum design of the system and to determinate a proper strategy for system operating control. The effect of various parameters, including solar insolation, ambient temperature, collector area, storage volume and speed of compressor, had been investigated on the thermal performance of the DX‐SAHP system, and the results had indicated that the system performance is governed strongly by the change of solar insolation, collector area and speed of compressor. The experimental results obtained under winter climate conditions were shown to agree reasonably with the computer simulation. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

4.
5.
6.
The present study deals with a small-scale solar-assisted absorption cooling system having a cooling capacity of 3.52 kW and was investigated experimentally under the climatic conditions of Taxila, Pakistan. Initially, a mathematical model was developed for LiBr/H2O vapor absorption system alongside flat-plate solar thermal collectors to achieve the required operating temperature range of 75°C. Following this, a parametric analysis of the whole system was performed, including various design and climate parameters, such as the working temperatures of the generator, evaporator, condenser, absorber, mass flow rate, and coefficient of performance (COP) of the system. An experimental setup was coupled with solar collectors and instruments to get hot water using solar energy and measurements of main parameters for real-time performance assessment. From the results obtained, it was revealed that the maximum average COP of the system achieved was 0.70, and the maximum outlet temperature from solar thermal collectors was 75°C. A sensitivity analysis was performed to validate the potential of the absorption machine in the seasonal cooling demand. An economic valuation was accomplished based on the current cost of conventional cooling systems. It was established that the solar cooling system is economical only when shared with domestic water heating.  相似文献   

7.
In this paper, a novel integrated solar photovoltaic thermal absorption desalination system for freshwater and cooling production is proposed and analyzed thermodynamically. Ammonia–water pair is considered as a working fluid for the absorption system. Effect of average solar radiation for different months, time period of solar radiation availability in Abu Dhabi, salinity of seawater, and temperature of the seawater on energetic and exergetic COPs, production rate of freshwater, and overall performance of the system are investigated under different operating conditions. It is found that energetic and exergetic COPs, production rate of freshwater, energetic and exergetic utilization factors, and performance ratios vary greatly from one month to another because of the dynamic variation in solar radiation and its time of availability. The highest amount of freshwater is produced in the month of July as calculated to be 152 kg/h for a collector area of 100 m2 and solar power of 4.8 kW. The highest energetic and exergetic COPs and utilization factors are also obtained for the month of July. Moreover, the highest performance ratio is found to be 0.056 as obtained in the month of July when solar radiation intensity is highest as available for more than half of a day. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
The performance of a heat-pipe solar collector was investigated experimentally using refrigerants R11 as the working fluid. The unit is fabricated locally and its performance is evaluated under Beirut Solar conditions. The heat transfer from the heat pipes to the hot-water storage tank took place through a circular end condenser section of the heat-pipe integrated within the collector frame. Tests of single heat pipes showed that the thermal performance of the heat pipe were dependent on its tilt angle, condenser section length and configuration, and type of internal wick used. A circular condenser end of the heat-pipe performed better than a straight condenser due to increased surface area for heat transfer. The R11-charged solar collector with integrated condenser for secondary cooling of water had an efficiency in early operation hours that reached values higher than 60% for the forced circulation mode. The instantaneous system efficiencies varied from 60 to 20%, which are in the range of conventional water solar collectors. System response was fast and sensitive to the incident solar radiation. The thermosyphonic mode of the system operation generated build up of stored energy in the condenser, resulting in oscillating-type flow thus reducing system efficiency below values obtained with forced circulation. © 1998 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents seasonal‐energy storage of solar energy for the heating of buildings. We distinguish several types of seasonal storage, such as latent, sensible, and chemical storage, among which the thermochemical storage is used and analysed in this research. In the first part, a laboratory heat‐storage tank, which was made in the laboratory for heating, sanitary, and solar technology and air conditioning from the Faculty of Mechanical Engineering, University of Ljubljana, Slovenia, was presented. The experimental model was tested for charging and discharging mode. Two types of numerical models for sorption thermal‐energy storage exist, which are microscale and macroscale (integral). For microscale analysis, the analysis system (ANSYS) model can be used to simulate the behaviour in the adsorption reactor. On macroscale or integral scale, TRaNsient SYStem (TRNSYS) model was used to perform the operation of the storages on the yearly basis. In the second part the simulation of the underfloor heating system operation with a built‐in storage tank was carried out for two locations, Ljubljana and Portoro?. Furthermore, the comparison between a thermochemical and sensible‐heat storage was performed with TRNSYS and Excel software. In this comparison, the focus was on the surface parameters of the SCs and volume of the thermal‐storage tank for the coverage of the energy demand for selected building. With this analysis, we would like to show the advantage of the thermochemical storage system, to provide greater coverage of the energy demand for the operation of the building, compared with the seasonal sensible‐heat storage (SSHS). Such a heat‐storage technology could, in the future, be a key contributor to the more environmentally friendly and more sustainable way of delivering energy needs for buildings.  相似文献   

10.
The present study exemplifies the comprehensive thermal analysis to compare and contrast ammonia‐lithium nitrate (NH3‐LiNO3) and ammonia‐sodiumthiocynate (NH3‐NaSCN) absorption systems with and without incorporation of nanoparticles. A well‐mixed solution of copper oxide/water (CuO/H2O) nanofluid is considered inside a flat‐plate collector linked to an absorption chiller to produce 15‐kW refrigeration at ?5°C evaporator temperature. Enhancements in heat transfer coefficient, thermal efficiency, and useful heat gain of the collector are evaluated, and the effect of these achievements on the performance of both absorption chillers have been determined for different source temperatures. A maximum 121.7% enhancement is found in the heat transfer coefficient with the application of the nanofluid at 2% nanoparticle concentration. The maximum coefficient of performance observed for the NH3‐NaSCN chiller is 0.12% higher than that for the NH3‐LiNO3 chiller at 0°C evaporator temperature. Contradictory to this, the average system coefficient of performance of the NH3‐LiNO3 absorption system has been found 5.51% higher than that of the NH3‐NaSCN system at the same evaporator temperature. Moreover, the application of the nanofluid enhanced the performance of the NH3‐NaSCN and NH3‐LiNO3 systems by 2.70% and 1.50%, respectively, for lower generator temperature and becomes almost the same at higher temperatures, which altogether recommends the flat‐plate collector–coupled NH3‐LiNO3 absorption system be integrated with a nanofluid.  相似文献   

11.
Solar‐driven polygeneration systems are promising technologies for covering many energy demands with a renewable and sustainable way. The objective of the present work is the investigation of a trigeneration system, which is driven by solar‐dish collectors. The examined trigeneration system includes an organic Rankine cycle (ORC), which operates with toluene, and an absorption heat pump, which operates with LiBr/H2O. The absorption heat pump is fed with heat by the condenser of the ORC, which operates at medium temperature levels (120°C to 150°C). The absorption heat pump produces both useful heat at 55°C and cooling at 12°C. The ORC produces electricity, and it is fed by the solar dishes. The examined ORC is a regenerative cycle with superheating. The total analysis is performed with a developed model in Engineering Equation Solver (EES). The system is investigated parametrically for different ORC heat‐rejection temperatures, different superheating levels in the turbine inlet, and various solar‐beam irradiation levels. Furthermore, the system is investigated on a yearly basis for the climate conditions of Athens (Greece) and for Belgrade (Serbia). It is found that the yearly system energy and exergy efficiencies are 108.39% and 20.92%, respectively, for Athens, while 111.38% and 21.50%, respectively, for Belgrade. The values over 100% for the energy efficiency are explained by the existence of a heat pump in the examined configuration. For both locations, the payback period is found close to 10 years and the internal rate of return close to 10%. The final results indicate that the examined configuration is a highly efficient and viable system, which operates only with a renewable energy source.  相似文献   

12.
This paper is motivated by the crisis of freshwater in remote areas around the world and responds to the growing need for sustainable food production in arid lands. It focuses on utilizing solar energy to yield freshwater from the sea or brackish water with less environmental impacts, for greenhouses, which can produce sustainable food all over the year. The integration of various solar‐driven desalinations such as solar still, humidification‐dehumidification, reverse osmosis, electrodialysis, and multieffect and multistage flash with greenhouses are evaluated, for better sustainability towards greenization. The paper first discusses the specifications of solar‐driven desalinations and compares their advantages and limitations. Then, different types of greenhouses are introduced, and their total water requirement is discussed based on their locations, crop type, greenhouse technology, irrigation type, and environmental conditions, as well as their cooling and heating strategies. Later, the existing integration of solar‐driven desalinations with greenhouses are reviewed, and their advantages and limitations are deliberated. Finally, the paper discusses the criteria to be considered when selecting solar‐driven desalinations for greenhouses and presents a detailed comparison between the water production rate and cost as well as the energy consumption of these systems. In the end, the most appropriate combinations of solar‐driven desalinations with greenhouses are recommended based on their water requirement and production cost.  相似文献   

13.
The thermal performance of two different schemes of solar‐assisted heat‐pump systems has been theoretically studied. In first scheme, the evaporator of the heat pump is taken directly as the solar collecting plate and always maintained at the ambient temperature. As there is no heat loss from the collecting plate, the thermal efficiency of the collector is high and equals the solar absorptivity of the collecting plate. As suggested, the heat‐pump evaporator of the second scheme is placed in a novel fresh water solar pond/tank with high efficiency. Since the evaporator operates at a relatively high temperature, the COP of the heat pump can be increased. The calculated results show that the COP of a solar‐assisted heat pump using the second scheme is considerably higher than that of the first scheme. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

14.
A mathematical model has been used to predict the operating parameters of a desiccant wheel for performance analysis of the desiccant wheel. The model considered both gas and solid side resistance. The model shows a good agreement with experimental data. An experimental setup was fabricated using an evacuated tube solar air collector with a desiccant wheel. The hot air needed for regeneration is produced by the evacuated tube solar air collector, which has a collector surface area of 4.44 m2 . The regeneration can be started from 40 °C. The temperature of outlet air obtained is in the range of 40–65 °C in this evacuated tube solar air collector. The experimental setup was installed at NIT Kurukshetra, India, 29° 58′ (latitude) North and 76° 53′ (longitude) East. Numerical results showed that both the moisture removal and the temperature increment of the process air increases with an increasing regeneration air temperature, regeneration air inlet velocity, and process inlet moisture. But both the moisture removal and the temperature increment of the processed air decreases by increasing the process air inlet velocity and regeneration air moisture at the inlet. © 2012 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library (wileyonlinelibrary.com/journal/htj). DOI 10.1002/htj.21031  相似文献   

15.
16.
K. Gommed  G. Grossman   《Solar Energy》2007,81(1):131-138
Growing demand for air conditioning in recent years has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the environmentally-friendly techniques which may help alleviate the problem. A promising solar cooling method is through the use of a liquid desiccant system, where humidity is absorbed directly from the process air by direct contact with the desiccant. The desiccant is then regenerated, again in direct contact with an external air stream, by solar heat at relatively low temperatures. The liquid desiccant system has many potential advantages over other solar air conditioning systems and can provide a promising alternative to absorption or to solid desiccant systems.Earlier work by the authors included theoretical simulations and preliminary experiments on the key components of the liquid desiccant system. The objective of the present study has been to construct a prototype system based on the knowledge gained, to monitor its performance, identify problems and carry out preliminary design optimization. A 16 kWt system was installed at the Energy Engineering Center at the Technion, in the Mediterranean city of Haifa. The system comprises a dehumidifier and a regenerator with their associated components operating together to dehumidify the fresh (ambient) air supply to a group of offices on the top floor of the building. LiCl-water is employed as the working fluid. The system is coupled to a solar collector field and employs two methods of storage – hot water and desiccant solution in the regenerated state. The performance of the system was monitored for five summer months under varying operating conditions. The paper describes the operation of the experimental system and presents the measured data and the calculated performance parameters.  相似文献   

17.
18.
In a trigeneration plant, the thermal energy recovered from the prime mover is exploited to produce a cooling effect. Although this possibility allows the working hours of the plant to be extended over the heating period, providing summer air conditioning through thermally activated technologies, it is rather difficult to find in the literature experimental data on trigeneration plants operation, and the availability of performance characteristics at off‐design conditions is anyway limited. The paper has the aim of showing the experimental data of a real trigeneration system installed at the Politecnico di Torino (Turin, Italy), composed of a natural gas 100 kWel microturbine coupled to a liquid desiccant system. The data are presented for both cogeneration and trigeneration configurations, and for full and partial load operations. An energetic and economic performance assessment at rated power operation is presented, and compared with the partial load operation strategy. The primary energy savings are calculated through a widely accepted methodology, proposed by the European Union, and through another methodology, reported in literature, which seems to the Authors more suitable to describe the energetic performances of trigeneration plants. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
In this research, the development of a bioethanol reforming system for fuel cells (FBSR: fuel cell with bioethanol steam reforming) using sunlight as a heat source was investigated. The system was investigated using the experimental result of catalyst performance, and numerical analysis. If ethanol purity is high, the production method of the bioethanol used for the proposal system will not be limited. The overall efficiency of the production of electricity and heat power of this system was determined by examining its thermal output characteristic. The FBSR was introduced into standard individual houses in Sapporo, Japan, for analysis. The amount of hydrogen production, the production‐of‐electricity characteristic, and the thermal output characteristic were examined using meteorological data on representative days in March and August. Compared with the representative day in March (28.0 MJ day−1), the solar radiation of the representative day in August (37.0 MJ day−1) is large. However, the amount of solar radiation fluctuation of the representative day in August in this analysis is large compared with the representative day in March. It depends for the overall efficiency of the system on the amount of solar radiation fluctuation rather than the amount of solar radiation. As a result, the overall efficiency of the system, defined as the rate of power and heat output compared with the amount of solar heat collected, was calculated to be 47.4 and 41.9% on the representative days in March and August, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Over the last years, the thermal comfort level during the summer period has been significantly increased due to the use of conventional cooling and air-conditioning systems, leading to higher electricity consumption. Solar cooling systems may provide the solution and become the leading technology in the future. The aim of this paper is to present a small-scale solar thermal system for cooling an office building in Athens, Greece. The study documents the system design, the monitoring procedure and equipment, and presents the experimental results from the first complete summer period. The daily electrical coefficient of performance (COP) of the absorption chiller of 48.6 and the electrical COP of the solar system 10.9 indicate the potential of solar cooling in small-scale systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号