共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Itsumi K. Hosono Y. Yamamoto N. Yamashita Y. 《IEEE transactions on ultrasonics, ferroelectrics, and frequency control》2009,56(4):870-874
Effects of heavy density (p = 9.2 x 103 kg/m3) Yb2O3 fine dopant (16 nm in diameter) on the acoustic properties of a high-temperature-vulcanization (HTV) silicone rubber have been investigated, to develop a new acoustic lens material with a low acoustic attenuation (alpha) for the medical array probe application. The HTV silicone rubber has advantages in that it shows a lower alpha than that of a room-temperature-vulcanization (RTV) silicone rubber and it can be mixed by applying shear stress, using roll-milling equipment. Roll-milling time dependence of the HTV silicone rubber indicates that the alpha is closely affected by the dispersion of nanopowders in the rubber matrix. The 8 vol% Yb2O3-doped HTV silicone rubber mixed for 30 min showed the lowest alpha of 0.73 dB/mmMHz with an acoustic impedance [AI = sound speed (c) times density (p)] of 1.43 times 106 kg/m2s at 37degC. Moreover, simulation results reveal that a 5 MHz linear probe using the HTV silicone rubber doped with Yb2O3 powder showed relative sensitivity around 2.6 to 3.0 dB higher than a probe using RTV silicone rubber doped with Yb2O3 powder or SiO2-doped conventional silicone rubber for the ultrasonic medical application. 相似文献
3.
交叉偶极阵列声波测井仪是目前主流的先进声波测井设备之一,但在测井过程中难免存在噪声干扰,对测井质量造成不利影响。在利用Matlab对大量实测信号进行时频分析的基础上,针对噪声的规律和特点,提出时域滤波和频域滤波相结合的方案。时域上采取限幅平均滤波法,频域上选择具有线性相位的FIR滤波器。利用Matlab滤波器设计与分析工具箱获取滤波器系数,借助DSP软件开发环境CCS,用汇编语言设计了基于DSP的井下实时FIR数字滤波器。现场测井试验表明,该滤波器对测井信号中存在的噪声具有良好的抑制作用,同时满足测井系统的实时性要求。 相似文献
4.
5.
We suggest a new method for measuring local values of the velocity and attenuation of leaky acoustic waves, which is based on wave field measurements using an immobile array of receiving ultrasonic transducers. In comparison to the methods using a single focused transducer mechanically scanned over a given region of the sample, the proposed technique is advantageous in having a higher operation speed due to the electronic switching of receiving channels in the array and in requiring no high-precision mechanical scanners. A ray model of the proposed measuring system comprising an array of ultrasonic transducers with an electronic scanning facility is described. Theoretical conclusions have been experimentally confirmed by tests on the samples with known properties. 相似文献
6.
7.
We suggest a new method for determining the longitudinal and transverse acoustic wave velocities and sample thicknesses, which
is based on the measurement and analysis of pulsed echo signals by an array of ultrasonic transducers. Analytical expressions
relating the delay of signals detected by the array and the values of parameters to be determined are obtained within the
framework of a ray model of the measuring system. Measurements on a reference sample have been performed. The values of ultrasonic
wave velocities and sample thickness obtained using the proposed technique agree with the results of measurements using independent
methods. 相似文献
8.
针对过钻具阵列声波测井对信号采集电路高精度、大动态、低噪声、低功耗、高集成度以及各通道同步性好的要求,设计一种多通道数据采集电路。该电路采用各通道独立数字化方案以保证各通道信号采集的同步性,采用低噪音仪表放大器作为前置放大器以降低系统噪声,选用18位ADC扩大数字化动态,ADC输出采用菊花链连接以减少电路连线。实测结果表明:12通道采集电路功耗为550 mW,噪声均方根值小于13μV,信号测量动态范围达93 dB,单通道采集电路面积为19 mm×70 mm。因此,设计电路既能很好满足过钻具阵列声波测井信号采集要求,也可作为其他阵列声波测井信号采集的参考方案。 相似文献
9.
10.
测量超声场声强用组合式水听器的设计方案 总被引:3,自引:2,他引:1
介绍1种可用于测量超声波声场强度的新型水听器。它是由声压型水听器与振速水听器在结构上组合为一体而构成,文中描述了这种水听器的基本结构型式,工作原理及特性。 相似文献
11.
An air parametric array can generate a highly directional beam of audible sound in air,which has a wide range of applications in targeted audio delivery.Capacitive micromachined ultrasonic transducer(CMUTs)have great potential for air-coupled applications,mainly because of their low acoustic impedance.In this study,an air-coupled CMUT array is designed as an air parametric array.A hexagonal array is proposed to improve the directivity of the sound generated.A finite element model of the CMUT is established in COMSOL software to facilitate the choice of appropriate structural parameters of the CMUT cell.The CMUT array is then fabricated by a wafer bonding process with high consistency.The performances of the CMUT are tested to verify the accuracy of the finite element analysis.By optimizing the component parameters of the bias-T circuit used for driving the CMUT,DC and AC voltages can be effectively applied to the top and bottom electrodes of the CMUT to provide efficient ultrasound transmission.Finally,the prepared hexagonal array is successfully used to conduct preliminary experiments on its application as an air parametric array. 相似文献
12.
13.
14.
针对经典波束形成算法不具备实时性、占用存储空间大、计算速度慢等缺点,提出了基于卡尔曼滤波器的算法。这种算法将信号处理领域中现有的卡尔曼滤波器理论与阵列信号处理过程相结合,在频域内对声学阵列所采集到的数据进行迭代处理,不仅能够及时发现风洞测量中存在的各种问题,而且可以实时消除由测量环境所引起的各种误差。仿真结果表明,这种算法比经典波束形成算法收敛速度更快,不仅成像效果很好,而且能够对低速运动声源进行定位。此算法具备实时性,为风洞声源的实时定位提供了重要的算法选择。 相似文献
15.
Feng Gao Wei Gai Thomas Wong Chunguang Jing Wanming Liu 《Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment》2009,609(2-3):89-94
The design of an electron-beam excited device for millimeter-wave generation is presented. Referred to as a dielectric-loaded power extractor, it is based on the higher-order-mode operation of a dielectric-loaded waveguide. With a matching transition, the unit can deliver power to the output waveguide at one of two frequencies, 20.8 and 35.1 GHz, corresponding to the TM02 and TM03 modes, respectively. By properly choosing the thickness of the dielectric lining, both modes are tuned to synchronize with an ultra-relativistic electron beam traversing the unit so that the wakefield generated by the beam is excited at these modes, chosen to be at 20.8 and 35.1 GHz, respectively, both corresponding to a harmonic of the 1.3 GHz operating frequency at an accelerator facility. Power generated in the unintended TM01 mode is effectively suppressed for bunch train operation by a novel technique. The device consists of a dielectric-loaded decelerating structure and two changeable output couplers to deliver the millimeter-wave power to a standard waveguide. For a drive beam with 50 nC of charge per bunch, power levels of 90.4 and 8.68 MW are expected to be delivered by the device at 20.8 and 35.1 GHz, respectively. 相似文献
16.
Ziping Wang Ying Luo Guoqi Zhao Fuh-Gwo Yuan 《International Journal of Mechanics and Materials in Design》2017,13(1):57-69
In contrast to piezoceramics, orthotropic piezoelectric fibre composites (OPFC) which can be used as actuator/sensor elements in damage detection show clear advantages because of their high sensitivity along the fibre direction and directivity. The focusing acoustic field distribution of the OPFC phased array transducer is analyzed by the finite element method together with directivity analysis in metallic materials. The optimal array parameters such as spacing, width and number of elements are obtained by studying the total displacement changes as various parameters change at the focus point. The feasibility of an OPFC ultrasonic phased array transducer for damage detection is validated. 相似文献
17.
18.
19.
本文介绍了一种能沿任意波束指向全程动态聚焦的数字波束合成器的设计,此合成器用于相控阵B超成像系统。回声信号的延时量分解为“指向延时”和“聚焦延时”两部分,分别用产生相控发射激励的时序逻辑电路和一个“动态聚焦延时量表”实现。通过对A/D采样时钟的控制及对A/D采样时钟、地址计数时钟和存储器写时钟的时序配合,实现了同相位数据点采样及无冗余数据的缓冲存储器。所设计的数字相控波束合成器只用廉价的高速数字电路即可实现,成本极低。实验结果验证了该方案的可行性。 相似文献
20.
Aspheric optical surfaces are often tested using diffractive optics as null elements. For precise measurements, the errors caused by the diffractive optical element must be calibrated. Recently, we reported first experimental results of a three position quasi-absolute test for rotationally invariant aspherics by using combined-diffractive optical elements (combo-DOEs). Here we investigate the effects of the DOE substrate errors on the proposed calibration procedure and present a set of criteria for designing an optimized combo-DOE. It is demonstrated that this optimized design enhances the overall consistency of the procedure. Furthermore, the rotationally varying part of the surface deviations is compared with the rotationally varying deviations obtained by an N-position averaging procedure and is found to be in good agreement. 相似文献