首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Matrix sublimation has demonstrated to be a powerful approach for high-resolution matrix-assisted laser desorption ionization (MALDI) imaging of lipids, providing very homogeneous solvent-free deposition. This work presents a comprehensive study aiming to evaluate current and novel matrix candidates for high spatial resolution MALDI imaging mass spectrometry of lipids from tissue section after deposition by sublimation. For this purpose, 12 matrices including 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA), 2,6-dihydroxyacetphenone (DHA), 2',4',6'-trihydroxyacetophenone (THAP), 3-hydroxypicolinic acid (3-HPA), 1,8-bis(dimethylamino)naphthalene (DMAN), 1,8,9-anthracentriol (DIT), 1,5-diaminonapthalene (DAN), p-nitroaniline (NIT), 9-aminoacridine (9-AA), and 2-mercaptobenzothiazole (MBT) were investigated for lipid detection efficiency in both positive and negative ionization modes, matrix interferences, and stability under vacuum. For the most relevant matrices, ion maps of the different lipid species were obtained from tissue sections at high spatial resolution and the detected peaks were characterized by matrix-assisted laser desorption ionization time-of-flight/time-of-flight (MALDI-TOF/TOF) mass spectrometry. First proposed for imaging mass spectrometry (IMS) after sublimation, DAN has demonstrated to be of high efficiency providing rich lipid signatures in both positive and negative polarities with high vacuum stability and sub-20 μm resolution capacity. Ion images from adult mouse brain were generated with a 10 μm scanning resolution. Furthermore, ion images from adult mouse brain and whole-body fish tissue sections were also acquired in both polarity modes from the same tissue section at 100 μm spatial resolution. Sublimation of DAN represents an interesting approach to improve information with respect to currently employed matrices providing a deeper analysis of the lipidome by IMS.  相似文献   

2.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) provides localized information about the molecular content of a tissue sample. To derive reliable conclusions from MSI data, it is necessary to implement appropriate processing steps in order to compare peak intensities across the different pixels comprising the image. Here, we review commonly used normalization methods, and propose a rational data processing strategy, for robust evaluation and modeling of MSI data. The approach includes newly developed heuristic methods for selecting biologically relevant peaks and pixels to reduce the size of a data set and remove the influence of the applied MALDI matrix. The methods are demonstrated on a MALDI MSI data set of a sagittal section of rat brain (4750 bins, m/z = 50-1000, 111 × 185 pixels) and the proposed preferred normalization method uses the median intensity of selected peaks, which were determined to be independent of the MALDI matrix. This was found to effectively compensate for a range of known limitations associated with the MALDI process and irregularities in MS image sampling routines. This new approach is relevant for processing of all MALDI MSI data sets, and thus likely to have impact in biomarker profiling, preclinical drug distribution studies, and studies addressing underlying molecular mechanisms of tissue pathology.  相似文献   

3.
Pirman DA  Yost RA 《Analytical chemistry》2011,83(22):8575-8581
Matrix-assisted laser desorption/ionization (MALDI) based mass spectrometric imaging (MSI) is increasingly being used as an analytical tool to evaluate the molecular makeup of tissue samples. From the direct analysis of a tissue section, the physical integrity of sample is preserved; thus, spatial information of a compound's distribution may be determined. One limitation of the technique, however, has been the inability to determine the absolute concentration from a tissue sample. Here we report the development of a quantitative MSI technique in which the distribution of acetyl-L-carnitine (AC) in a piglet brain sample is quantified with MALDI MSI. An isotopically labeled internal standard was applied uniformly beneath the tissue section, and wide-isolation tandem mass spectrometry was performed. Normalizing the analyte ion signal by the internal standard ion signal resulted in significant improvements in MS images, signal reproducibility, and calibration curve linearity. From the improved MS images, the concentration of AC was determined and plotted producing a concentration-scaled image of the distribution of AC in the piglet brain section.  相似文献   

4.
Nayak R  Liu J  Sen AK  Knapp DR 《Analytical chemistry》2008,80(22):8840-8844
A gold coated nanoporous alumina surface was used for dual ionization mode mass spectrometric analysis using desorption electrospray ionization (DESI) and laser desorption ionization (LDI). DESI and LDI mass spectrometry (MS) from the nanoporous alumina surface were compared with conventional electrospray ionization (ESI) mass spectrometry and matrix assisted laser desorption ionization (MALDI) for analysis of tryptic digests of proteins. Combined use of DESI and LDI offer greater peptide coverage than either method alone and comparable peptide coverage as with dual MALDI and ESI. This dual ionization technique using a common platform with same sample spot demonstrates a potential time and cost-effective tool for improved shotgun proteomic analysis.  相似文献   

5.
We have achieved enhanced lipid imaging to a ~10 μm spatial resolution using negative ion mode matrix assisted laser desorption ionization (MALDI) imaging mass spectrometry, sublimation of 2,5-dihydroxybenzoic acid as the MALDI matrix, and a sample preparation protocol that uses aqueous washes. We report on the effect of treating tissue sections by washing with volatile buffers at different pHs prior to negative ion mode lipid imaging. The results show that washing with ammonium formate, pH 6.4, or ammonium acetate, pH 6.7, significantly increases signal intensity and number of analytes recorded from adult mouse brain tissue sections. Major lipid species measured were glycerophosphoinositols, glycerophosphates, glycerolphosphoglycerols, glycerophosphoethanolamines, glycerophospho-serines, sulfatides, and gangliosides. Ion images from adult mouse brain sections that compare washed and unwashed sections are presented and show up to 5-fold increases in ion intensity for washed tissue. The sample preparation protocol has been found to be applicable across numerous organ types and significantly expands the number of lipid species detectable by imaging mass spectrometry at high spatial resolution.  相似文献   

6.
The use of an intermediate-pressure matrix-assisted laser desorption/ionization (IP-MALDI) source working at 0.17 Torr on a linear ion trap (LIT) was investigated for the analysis of tissue specimens, in particular, spinal cord sections. MALDI, with 2,5-dihydroxybenzoic acid (DHB) as the matrix, was employed for the detection of phospholipids. The matrix was applied to the tissue using electrospray to avoid analyte migration. The results indicate that analyzing tissue specimens at nontraditional MALDI vacuum pressures is possible. Coupling MALDI to an LIT permits the use of MSn, which is critical for the ability to identify compounds desorbed directly from tissue specimens. Using MSn, ions detected from m/z 600-1000 were characterized as phosphatidlycholines, PC. Specifically, using tandem MS, PC ions could be classified as either [M + H]+ or [M + Na]+ because the fragmentation patterns of protonated and sodiated phosphatidlycholines follow different pathways.  相似文献   

7.
MALDI (matrix-assisted laser desorption/ionization) imaging mass spectrometry (IMS) is a new technology that generates molecular profiles and two-dimensional ion density maps of peptide and protein signals directly from the surface of thin tissue sections. This allows specific information to be obtained on the relative abundance and spatial distribution of proteins. One important aspect of this is the opportunity to correlate these specific ion images with histological features observed by optical microscopy. To facilitate this, we have developed protocols that allow MALDI mass spectrometry imaging and optical microscopy to be performed on the same section. Key components of these protocols involve the use of conductive glass slides as sample support for the tissue sections and MS-friendly tissue staining protocols. We show the effectiveness of these with protein standards and with several types of tissue sections. Although stain-specific intensity variations occur, the overall protein pattern and spectrum quality remain consistent between stained and control tissue samples. Furthermore, imaging mass spectrometry experiments performed on stained sections showed good image quality with minimal delocalization of proteins resulting from the staining protocols.  相似文献   

8.
Mass spectrometric imaging (MSI) has emerged as a powerful technique to obtain spatial arrangement of individual molecular ions in animal tissues. Ambient desorption electrospray ionization (DESI) technique is uniquely suited for such imaging experiments, as it can be performed on animal tissues in their native environment without prior treatments. Although MSI has become a rapid growing technique for localization of proteins, lipids, drugs, and endogenous compounds in different tissues, quantification of imaged targets has not been explored extensively. Here we present a novel MSI approach for localization and quantification of drugs in animal thin tissue sections. DESI-MSI using an Orbitrap mass analyzer in full scan mode was performed on 6 μm coronal brain sections from rats that were administered 2.5 mg/kg clozapine. Clozapine was localized and quantified in individual brain sections 45 min postdose. External calibration curves were prepared by micropipetting standards with internal standard (IS) on top of the tissues, and average response factors were calculated for the scans in which both clozapine and IS were detected. All response factors were normalized to area units. Quantifications from DESI-MSI revealed 0.2-1.2 ng of clozapine in individual brain sections, results that were further confirmed by extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis.  相似文献   

9.
An infrared laser was used to ablate material from tissue sections under ambient conditions for direct collection on a matrix assisted laser desorption ionization (MALDI) target. A 10 μm thick tissue sample was placed on a microscope slide and was mounted tissue-side down between 70 and 450 μm from a second microscope slide. The two slides were mounted on a translation stage, and the tissue was scanned in two dimensions under a focused mid-infrared (IR) laser beam to transfer material to the target slide via ablation. After the material was transferred to the target slide, it was analyzed using MALDI imaging using a tandem time-of-flight mass spectrometer. Images were obtained from peptide standards for initial optimization of the system and from mouse brain tissue sections using deposition either onto a matrix precoated target or with matrix addition after sample transfer and compared with those from standard MALDI mass spectrometry imaging. The spatial resolution of the transferred material is approximately 400 μm. Laser ablation sample transfer provides several new capabilities not possible with conventional MALDI imaging including (1) ambient sampling for MALDI imaging, (2) area to spot concentration of ablated material, (3) collection of material for multiple imaging analyses, and (4) direct collection onto nanostructure assisted laser desorption ionization (NALDI) targets without blotting or ultrathin sections.  相似文献   

10.
Intense intact molecular ion signals have been obtained from phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, and phosphatidyiinositol using matrix-enhanced secondary ion mass spectrometry (ME-SIMS). It was found that the high-mass (m/z >500) regions of the ME-SIMS spectra closely resembled those obtained using matrix-assisted laser desorption/ionization (MALDI). Using high spatial resolution SIMS, a detailed investigation of dried-droplet samples was performed. Based on the detected Na+ and 2,5-DHB matrix signal intensities, different crystal types were distinguished, in addition to different sizes of crystals. Spatially mapping the pseudomolecular and fragment ions of the phospholipids revealed that the nature of the pseudomolecular ions formed, as well as the ratio of intact molecular to fragment ion, was dependent on the type and surface composition of the crystal. The observed chemical bias effects due to crystal heterogeneity and the resulting variation in desorption/ionization efficiency will complicate the interpretation of data obtained from matrix-assisted mass spectrometric (imaging) techniques and is an important factor in the "hot spot" phenomenon frequently encountered in MALDI experiments. In this respect, imaging SIMS was found to be a versatile tool to investigate the effects of the local physicochemical conditions on the detected molecular species.  相似文献   

11.
A novel matrix application protocol for direct tissue mass spectrometry is presented. Matrix-assisted laser desorption/ionization is a popular ionization procedure for direct tissue analysis and imaging mass spectrometry. Usually, matrixes are applied by dispensing droplets through either pipettes or automated dispensing machines, or by airbrushing. These techniques are very simple, but it was difficult to obtain uniform matrix crystals on the tissue surface, and nonuniform crystals degrade the spectrum qualities. Here we report a new matrix application protocol, which is a combination of spraying and dispensing droplets, and we have succeeded in overcoming these problems in conventional matrix applications on tissue surfaces. We call our new technique the "spray-droplet method". In this technique, tiny matrix crystals formed by spraying act as seeds for crystal growth. Our technique leads to matrix spots that are filled homogeneously with minute crystals. Such matrix crystals dramatically improve peak intensity and signal-to-noise ratio. In an example on a rat brain section, the number of detectable peaks was increased and signal intensity of m/z 5440 in our method was approximately 30.6 times higher than that in conventional methods. We used this spray-droplet method with a chemical ink-jet technology for matrix deposition to succeed in MALDI imaging of signals, which were undetectable from the conventional matrix applications.  相似文献   

12.
Desorption electrospray ionization (DESI) mass spectrometry (MS) is used in an imaging mode to interrogate the lipid profiles of 15 μm thin tissue cross sections of injured rat spinal cord and normal healthy tissue. Increased relative intensities of fatty acids, diacylglycerols, and lysolipids (between +120% and +240%) as well as a small decrease in intensities of lipids (-30%) were visualized in the lesion epicenter and adjacent areas after spinal cord injury. This indicates the hydrolysis of lipids during the demyelination process due to activation of phospholipase A(2) enzyme. In addition, signals corresponding to oxidative degradation products, such as prostaglandin and hydroxyeicosatetraenoic acid, exhibited increased signal intensity by a factor of 2 in the negative ion mode in lesions relative to the normal healthy tissue. Analysis of malondialdehyde, a product of lipid peroxidation and marker of oxidative stress, was accomplished in the ambient environment using reactive DESI mass spectrometry imaging. This was achieved by electrospraying reagent solution containing dinitrophenylhydrazine as high-velocity charged droplets onto the tissue section. The hydrazine reacts selectively and rapidly with the carbonyl groups of malondialdehyde, and signal intensity of twice the intensity was detected in the lesions compared to healthy spinal cord. With a small amount of tissue sample, DESI-MS imaging provides information on the composition and distribution of specific compounds (limited by the occurrence of isomeric lipids with very similar fragmentation patterns) in lesions after spinal cord injury in comparison with normal healthy tissue allowing identification of the extent of the lesion and its repair.  相似文献   

13.
We have employed matrix deposition by sublimation for protein image analysis on tissue sections using a hydration/recrystallization process that produces high-quality MALDI mass spectra and high-spatial-resolution ion images. We systematically investigated different washing protocols, the effect of tissue section thickness, the amount of sublimated matrix per unit area, and different recrystallization conditions. The results show that an organic solvent rinse followed by ethanol/water rinses substantially increased sensitivity for the detection of proteins. Both the thickness of the tissue section and the amount of sinapinic acid sublimated per unit area have optimal ranges for maximal protein signal intensity. Ion images of mouse and rat brain sections at 50, 20, and 10 μm spatial resolution are presented and are correlated with hematoxylin and eosin (H&E)-stained optical images. For targeted analysis, histology-directed imaging can be performed using this protocol where MS analysis and H&E staining are performed on the same section.  相似文献   

14.
A multiple ionization mass spectrometry strategy is presented based on the analysis of human serum extracts. Chromatographic separation was interfaced inline with the atmospheric pressure ionization techniques electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) in both positive (+) and negative (-) ionization modes. Furthermore, surface-based matrix-assisted laser desorption/ionization (MALDI) and desorption ionization on silicon (DIOS) mass spectrometry were also integrated with the separation through fraction collection and offline mass spectrometry. Processing of raw data using the XCMS software resulted in time-aligned ion features, which are defined as a unique m/z at a unique retention time. The ion feature lists obtained through LC-MS with ESI and APCI interfaces in both +/- ionization modes were compared, and unique ion tables were generated. Nonredundant, unique ion features, were defined as mass numbers for which no mass numbers corresponding to [M + H](+), [M - H](-), or [M + Na](+) were observed in the other ionization methods at the same retention time. Analysis of the extracted serum using ESI for both (+) and (-) ions resulted in >90% additional unique ions being detected in the (-) ESI mode. Complementing the ESI analysis with APCI resulted in an additional approximately 20% increase in unique ions. Finally, ESI/APCI ionization was combined with fraction collection and offline-MALDI and DIOS mass spectrometry. The parts of the total ion current chromatograms in the LC-MS acquired data corresponding to collected fractions were summed, and m/z lists were compiled and compared to the m/z lists obtained from the DIOS/MALDI spectra. It was observed that, for each fraction, DIOS accounted for approximately 50% of the unique ions detected. These results suggest that true global metabolomics will require multiple ionization technologies to address the inherent metabolite diversity and therefore the complexity in and of metabolomics studies.  相似文献   

15.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) combines information-rich chemical detection with spatial localization of analytes. For a given instrumental platform and analyte class, the data acquired can represent a compromise between analyte extraction and spatial information. Here, we introduce an improvement to the spatial resolution achievable with MALDI MSI conducted with standard mass spectrometric systems that also reduces analyte migration during matrix application. Tissue is placed directly on a stretchable membrane that, when stretched, fragments the tissue into micrometer-sized pieces. Scanning electron microscopy analysis shows that this process produces fairly homogeneous distributions of small tissue fragments separated and surrounded by areas of hydrophobic membrane surface. MALDI matrix is then applied by either a robotic microspotter or an artist's airbrush. Rat spinal cord samples imaged with an instrumental resolution of 50-250 μm demonstrate lipid distributions with a 5-fold high spatial resolution (a 25-fold increase in pixel density) after stretching compared to tissues that were not stretched.  相似文献   

16.
Imaging mass spectrometry (IMS) that utilizes matrix-assisted laser desorption/ionization (MALDI) technology can provide a molecular ex vivo view of resected organs or whole-body sections from an animal, making possible the label-free tracking of both endogenous and exogenous compounds with spatial resolution and molecular specificity. Drug distribution and, for the first time, individual metabolite distributions within whole-body tissue sections can be detected simultaneously at various time points following drug administration. IMS analysis of tissues from 8 mg/kg olanzapine dosed rats revealed temporal distribution of the drug and metabolites that correlate to previous quantitative whole-body autoradiography studies. Whole-body MALDI IMS is further extended to detecting proteins from organs present in a whole-body sagittal tissue section. This technology will significantly help advance the analysis of novel therapeutics and may provide deeper insight into therapeutic and toxicological processes, revealing at the molecular level the cause of efficacy or side effects often associated with drug administration.  相似文献   

17.
Cha S  Yeung ES 《Analytical chemistry》2007,79(6):2373-2385
Graphite-assisted laser desorption/ionization (GALDI) mass spectrometry (MS) was investigated for analysis of cerebrosides in a complex total brain lipid extract. Conventional MALDI MS and GALDI MS were compared regarding lipid analysis by using high-vacuum (HV, <10-6 Torr) LDI time-of-flight mass spectrometry and intermediate-pressure (IP, 0.17 Torr) linear ion trap mass spectrometry. Cerebrosides were not detected or detected with low sensitivity in MALDI MS because of other dominant phospholipids. By using GALDI, cerebrosides were detected as intense mass peaks without prior separation from other lipid species while mass peaks corresponding to phosphatidylcholines (PCs) were weak. The signal increase for cerebrosides and the signal decrease for PCs in GALDI MS were more significant in HV than in IP. MSn experiments of precursor ions corresponding to cerebrosides and PCs in brain lipid extract were performed to identify the detected species and distinguish isobaric ions. Twenty-two cerebroside species were detected by GALDI whereas eight cerebroside species were detected by MALDI. Sulfatides in brain lipid extract were also easily detected by GALDI MS in the negative ion mode. By forming a colloidal graphite thin film on rat brain tissue, direct lipid profiling by imaging mass spectrometry (IMS) was performed. Chemically selective images for cerebrosides and sulfatides were successfully obtained. Imaging tandem mass spectrometry (IMS/MS) was performed to generate images of specific product ions from isobaric species.  相似文献   

18.
This work reports on a new and extremely simple approach for determination of a double bond position by a laser desorption ionization mass spectrometry. It is solely based on the catalytic properties of nanostructured surfaces used in nanoassisted laser desorption ionization experiments. These surfaces can induce oxidation of analytes, which results in a mass shift that can be detected by mass spectrometry. If a site of unsaturation is oxidized and cleaved, the m/z difference is diagnostic of the position of a double bond. By demonstrating that the oxidation depends on the analyte surface dwell time, it was proven that it is caused by the surface activity and not by the laser desorption ionization process itself. Control matrix-assisted laser desorption/ionization (MALDI) experiment showed only a limited partial oxidation and no time dependency of the process. The ability to determine a position of a double bond was demonstrated on polyunsaturated phospholipids and cyclosporine A. In some other cases, however, the unexpected oxidation could cause confusion, as demonstrated for a glycosphingolipid from a porcine brain extract.  相似文献   

19.
Discussed here is an analytical method for profiling lipids and phospholipids directly from mammalian tissues excised from Mus musculus (house mouse). Biochemical analysis was accomplished through the use of matrix-assisted laser desorption/ionization (MALDI) Fourier transform mass spectrometry, where whole tissue sections of mouse brain, heart, and liver were investigated. Lipid and phospholipid ions create complex MALDI mass spectra containing multiple ions with different m/z values corresponding to the same fundamental chemical species. When a computational sorting approach is used to group these ions, the standard deviation for observed relative chemical abundance can be reduced to 6.02%. Relative standard deviations of 10% are commonly accepted for standard chromatographic phospholipid analyses. Average mass measurement accuracy for 232 spectra representing three tissue types from 12 specimens was calculated to be 0.0053 Da. Further it is observed, that the data and the analysis between all the animals have near-identical phospholipid contents in their brain, heart, and liver tissues, respectively. In addition to the need to accurately measure relative abundances of phospholipid species, it is essential to have adequate mass resolution for complete and accurate overall analysis. It is reasonable to make mass composition assignments with spectral resolving power greater than 8000. However, results from the present study reveal 14 instances (C12 carbon isotope) of multiple m/z ions having the same nominal value that require greater resolution in order that overlap will not occur. Spectra measured here have an average resolving power of 12 000. It is established that high mass resolution and mass accuracy coupled with MALDI ionization provide for rapid and accurate phospholipid analysis of mammalian tissue sections.  相似文献   

20.
The distributions of positron emission tomography (PET) ligands in rat brain tissue sections were analyzed by matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI). The detection of the PET ligands was possible following the use of a solvent-free dry MALDI matrix application method employing finely ground dry α-cyano-4-hydroxycinnamic acid (CHCA). The D2 dopamine receptor antagonist 3,5-dichloro-N-{[(2S)-1-ethylpyrrolidin-2-yl]methyl}-2-hydroxy-6-methoxybenzamide (raclopride) and the D1 dopamine receptor antagonist 7-chloro-3-methyl-1-phenyl-1,2,4,5-tetrahydro-3-benzazepin-8-ol (SCH 23390) were both detected at decreasing abundance at increasing period postdosing. Confirmation of the compound identifications and distributions was achieved by a combination of mass-to-charge ratio accurate mass, isotope distribution, and MS/MS fragmentation imaging directly from tissue sections (performed using MALDI TOF/TOF, MALDI q-TOF, and 12T MALDI-FT-ICR mass spectrometers). Quantitative data was obtained by comparing signal abundances from tissues to those obtained from quantitation control spots of the target compound applied to adjacent vehicle control tissue sections (analyzed during the same experiment). Following a single intravenous dose of raclopride (7.5 mg/kg), an average tissue concentration of approximately 60 nM was detected compared to 15 nM when the drug was dosed at 2 mg/kg, indicating a linear response between dose and detected abundance. SCH 23390 was established to have an average tissue concentration of approximately 15 μM following a single intravenous dose at 5 mg/kg. Both target compounds were also detected in kidney tissue sections when employing the same MSI methodology. This study illustrates that a MSI may well be readily applied to PET ligand research development when using a solvent-free dry matrix coating.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号