首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 855 毫秒
1.
PurposeTo assess the tear film surface quality after orthokeratology using an automated Medmont E300 corneal topographer.MethodsChildren who wore orthokeratology lenses for more than one year were selected in this retrospective study. Tear film disruption (TFD) and central tear film disruption (cTFD) were measured with Medmont E300 corneal topographer at initial and each follow-up visit after fitting with orthokeratology lenses, providing a nominal value from 0 (perfect) to 1 (poor). Tear film surface quality before and after ortho-k treatment was compared.Results145 children using orthokeratology lenses were observed. TFD and cTFD significantly increased at 1-day follow up (TFD, t = -17.3, P < 0.001; cTFD, t = -10.4, P < 0.001). This change remained consistent through to 12-months visit (TFD, F = 51.1, P < 0.001; cTFD, F = 28.0, P < 0.001). A sub-group of n = 11 children were discontinued for 1-month before being refit with OrthoK lenses of a different design. Similarly, there was a significant increase in TFD compared to pre-orthoK scans (0.172 ± 0.161), but this returned to baseline levels after ceasing lens wear (0.084 ± 0.059). A sub-group of monocular OrthoK wearers (n = 23) found that TFD and cTFD values increased in eyes with monocular lens-wearing but remained stable in the lateral eyes.ConclusionsObjective measurements of tear-film quality are reduced in children after fitting with orthokeratology lenses, but return to baseline after 1-month of lens cessation. It is of importance to ensure tear film surface quality is continuously monitored throughout use of orthoK lenses.  相似文献   

2.
When a contact lens is in contact with the eyelid and the cornea, tear proteins start to be accumulated on the lens and may subsequently undergo conformational changes. Protein adsorption or conformational changes on the lens may lead to discomfort, red eye, or even inflammatory reactions. Although measuring the friction coefficient of contact lens has been linked to comfort degree in vivo, there is not much research about the effects of tear protein deposition on the friction coefficient of the contact lens. Therefore, we investigated the friction coefficient of three distinct materials of contact lenses in two different lysosomal concentrations. We also studied lysozyme deposition on the lens without the influence of friction. The results demonstrated that although the amount of lysozyme deposition was high on all the materials we tested, it was not corresponded to higher friction coefficient. In addition, we investigated the effect of the contact lens care solution we developed on friction coefficient and lysozyme deposition of three different materials of contact lenses. The results showed that the care solution could reduce the increased friction coefficient caused by high lysosomal concentration. Therefore, we proposed a potential mechanism of why lysosomal deposition may result in high friction coefficient for certain types of hydrogel contact lenses.  相似文献   

3.
PurposeTo evaluate the changes in ocular surface parameters during orthokeratology lens wear and determine their correlations with ocular discomfort symptoms.MethodsFifty individuals were enrolled in this prospective pilot study. Clinical evaluation of the ocular surface included the ocular surface disease index, slit-lamp examination, Keratograph 5M, optical quality analysis system, and corneal staining. After baseline examinations, clinical tests were performed at 1 day, 1 week, 1 month, 3 months, 6 months, and 12 months after orthokeratology lens wear. Correlations between ocular discomfort symptoms and signs of ocular discomfort were evaluated.ResultsOverall ocular surface disease index score and two subscale scores (ocular symptoms and vision-related function) significantly increased at the 3-month visit (P < 0.05), and decreased to levels close to baseline at the12-month visit (P > 0.05). The basic objective scatter index and the mean tear film objective scatter index increased, peaking at 3-month visit (P < 0.05) and gradually decreased thereafter. The modulation transfer function cut-off significantly decreased at the 3-month visit (P < 0.05). During the 12-month study period, the overall ocular surface disease index score and vision-related function score were significantly and positively correlated with the basic objective scatter index and mean tear film objective scatter index (P < 0.05). After 1 week of lens wear, Grade 1 corneal staining increased to 16.4 %, mostly involving the central and inferior cornea.ConclusionsOrthokeratology lens wear increased ocular discomfort symptoms and decreased the function of tear film, mainly within 3 months of lens wear. Tear-related visual function parameters were correlated with ocular discomfort. A new parameter, tear film objective scatter index, measured with the optical quality analysis system, was more sensitive in detecting the quality and stability of tear film than traditional indicators.  相似文献   

4.
PurposeThe aim of the current study is to assess, using new technologies, the interaction of four monthly silicone hydrogel contact lenses on the ocular surface and the comfort over 15 days of use.MethodsProspective cross-over, randomized and double-masked study including four materials (lotrafilcon-B, samfilcon-A , comfilcon-A and filcom-V3). Clinical examination was performed in the following order: tear meniscus height, first break-up of the tear film, the average time of all tear film breakup incidents, bulbar redness, limbal redness (Keratograph 5M ,Oculus, Germany); central corneal thickness (Pentacam, Oculus, Germany), thermography values (FLIR A325; FLIR Systems Inc., USA), and slit-lamp evaluations, including ocular surface staining. Finally, subjective comfort was obtained from Contact Lens Dry Eye Questionnaire-8.ResultsThe impact of contact lens wear on the ocular surface didn’t show statistically significant changes over time except for corneal and conjunctival staining grades on day 15 compared to day 1 for the comfilcon A group (P = .003 and P = .01, respectively). Contact lens stability and impact on the ocular surface during contact lens wear didn’t show statistically significant changes over time except in the case of the comfilcon A material with respect to the irritation item (P = .01).ConclusionsThese results suggest that the impact of monthly silicone hydrogel contact lens materials on the ocular surface after and during contact lens wear, contact lens stability over time, and subjective comfort did not reveal any significant changes over 15 days of use for any of the materials.  相似文献   

5.
Proteins are a key component in body fluids and adhere to most biomaterials within seconds of their exposure. The tear film consists of more than 400 different proteins, ranging in size from 10 to 2360 kDa, with a net charge of pH 1-11. Protein deposition rates on poly-2-hydroxyethyl methacrylate (pHEMA) and silicone hydrogel soft contact lenses have been determined using a number of ex vivo and in vitro experiments. Ionic, high water pHEMA-based lenses attract the highest amount of tear film protein (1300 μg/lens), due to an electrostatic attraction between the material and positively charged lysozyme. All other types of pHEMA-based lenses deposit typically less than 100 μg/lens. Silicone hydrogel lenses attract less protein than pHEMA-based materials, with <10 μg/lens for non-ionic and up to 34 μg/lens for ionic materials. Despite the low protein rates on silicone hydrogel lenses, the percentage of denatured protein is typically higher than that seen on pHEMA-based lenses. Newer approaches incorporating phosphorylcholine, polyethers or hyaluronic acid into potential contact lens materials result in reduced protein deposition rates compared to current lens materials.  相似文献   

6.
The purpose of this study was to determine the effect of contact lens wear on the tear film and ocular surface of people tolerant or intolerant to contact lens wear. Twenty subjects participated; 11 tolerants and nine intolerants. Their baseline tear film (no lens wear) was analysed with a range of clinical measurements and protein analyses (lactoferrin, sIgA and lysozyme). The tests were then repeated at the end of 6h of contact lens wear during the day and while lenses were worn. Both tolerants and intolerants showed statistically significant increases in bulbar and overall conjunctival redness after 6h of lens wear. For tolerants only, there was a statistically significant increase in the tear film meniscus area (0.08 mm(2) +/- 0.04 compared to 0.14 mm(2) +/- 0.06 (p = 0.023)) and a statistically significant decrease in the non-invasive tear film break-up time (NI-TBUT; 21.3 s +/- 5.7 compared to 3.7 s +/- 4.3 (p = 0.003)) after 6h of lens wear. There were no changes in other tear film or ocular surface parameters. The protein concentration and lipid layer appearance did not change during lens wear for either population. Prior to lens wear, tolerant subjects had a statistically longer NI-TBUT, higher phenol red thread test and higher tear flow rate. After 6h of lens wear and while wearing lenses, all but NI-TBUT remained statistically different. Lens wear affected only a small number of clinical variables and 6h wear did not effect the concentration of those proteins measured in tears in this study.  相似文献   

7.
PurposeThe main goal was to study the biochemical composition of the tear film in two different times of the day.MethodsTear samples were collected from 10 individuals, non contact lenses wearers, from the university population without pathologies. To assess daily variations in the tear film, samples were collected twice in the day, one early in the morning and another in the evening using capillary tubes. Tear protein profile was analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), tumor necrosis factor α (TNF-α) and immunoglobulin A (IgA) were quantified by Enzyme-Linked ImmunoSorbent Assay (ELISA). Tear film stability was obtained through measurements of Non-Invasive Break Up Time and tear surface tension was measured by obtaining the Langmuir isotherms.ResultsThe stability of the tear film was higher in the morning than in the afternoon; corresponding to a higher value of surface tension in the afternoon. Protein electrophoresis tear profile is variable during the day as IgA concentration decreased from morning to afternoon (p < 0.05). TNF-α concentration also decreased, but there were not significant statistical differences (p = 0.089).ConclusionWe concluded that there are daily variations in the composition and properties of the tear film, indicating that changes occur without being caused by contact lenses wear or by the presence of ocular and systemic pathologies. Presence of TNF-α is not a direct indication of inflammatory pathology, since this cytokine was identified in relatively high amounts in subjects without inflammatory pathology.  相似文献   

8.

Purpose

The aim of this work was to investigate the locus and extent of vitronectin (Vn) deposition on ex vivo contact lenses and to determine the influence of wear modality together with surface and bulk characteristics of the lens material.

Methods

The quantity and location of Vn deposition on the surfaces of contact lens materials was investigated using a novel on-lens cell attachment assay technique.

Results

Vn mapping showed that deposition resulted from lens-corneal interaction rather than solely from the tear film. Higher cell counts on the posterior surface of the lenses were determined in comparison to the anterior surface. Overall gross Vn deposition was greater for high water content-low modulus materials (117 ± 4 average cell count per field) than low water content-high modulus materials (88 ± 6 average cell count per field).

Conclusions

The role of Vn in plasmin regulation and upregulation is widely recognised. The findings in this paper suggest that the locus of Vn on the contact lens surface, which is affected by material properties such as modulus, is potentially an important factor in the generation of plasmin in the posterior tear film. Consequently, the potential for materials to affect Vn deposition will influence lens-induced inflammatory processes.  相似文献   

9.
10.
ObjectivesTo assess the effects of different condition-induced changes on current and novel ocular surface metrics.MethodsEighty-four healthy volunteers (22.4 ± 2.6 years) participated in this study. The ocular surface and tear film response to (1) computer use, (2) contact lens insertion and (3) tear film instillation during computer use with contact lenses were assessed. Current metrics included the ocular surface disease (OSDI) questionnaire, 5-item dry eye questionnaire (DEQ-5), bulbar redness, tear meniscus height (TMH) and non-invasive keratograph break-up time (NIKBUT). Novel metrics included the lipid layer thickness obtained from the intensity of the reflected Placido disk and the speed of tear film particles post-blink.ResultsHigher dry eye symptoms, TMH and bulbar redness, and lower values in metrics related to the intensity of the Placido disk pattern and to particle speed were found after the computer reading task (p < 0.036). When a contact lens was fitted, lower TMH, NIKBUT and particle speed metrics were obtained (p < 0.044). Mixed ANOVA revealed that artificial tears significantly ameliorated the effect of computer reading on OSDI, DEQ-5, NIKBUT, metrics related to the intensity of the Placido disk pattern and metrics related to particle speed (p < 0.033).ConclusionsComputer use and contact lens wear worsened dry eye signs and symptoms, but artificial tears ameliorated this effect. Newly developed methods can serve as a tool to detect changes in the tear film triggered by different ocular surface-disturbing conditions.  相似文献   

11.
PurposeTo evaluate post-lens tear dynamics at two different time points during scleral lens wear in two cohorts with 10 neophytes each.MethodsAll subjects wore bilaterally scleral lenses for 5 h on 3 separate visits. Post-lens tear exchange was measured using Out-in method, which required 5 μL of 2% FITC-Dextran instilled on the bulbar conjunctiva during lens wear. Time taken to observe the first sign of fluorescence in post-lens tear reservoir was recorded with a stopwatch. Out-in measurements were collected at 5-hour post-lens insertion in Group 1 and compared with those obtained at 20 min of lens wear in Group 2. Tear dynamics under the lens was observed in Group 2 with fluorogram using a modified slit-lamp technique (Tan et al., 2018) to monitor post-lens fluorescence intensity and with high-resolution spectral domain optical coherence tomography (ENVISU 2300; Bioptigen Inc.) to measure post-lens tear thickness (PoLTT) over 5 h of lens wear.Results60% of subjects in Group 1 achieved Out-in times less than 5 min at 5-hour post-lens insertion, compared with 67% of subjects at 20-min lens wear (Tan et al., 2018). Using qualitative analysis on 60 series of data in Group 2 to compare the changes in fluorescence intensity and PoLTT with respect to lens-wearing time, 27% was due to lens settling, 13% was due to tear exchange and mixing while 60% indicated tear dynamics under scleral lenses was due to a combination of tear exchange, mixing, and lens settling.ConclusionTear flow into tear reservoir under a scleral lens on subjects with healthy cornea occurred at 20 min and 5 h after lens insertion. After 5 h of lens wear, roughly one third of the subjects had no tear flow into post-lens reservoir, as the observed decline in post-lens tear fluorescence was predominately due to lens settling.  相似文献   

12.

Purpose

To determine and compare the levels of surface versus bulk active lysozyme deposited on several commercially available hydrogel contact lens materials.

Methods

Hydrogel contact lens materials [polymacon, omafilcon A, nelfilcon A, nesofilcon A, ocufilcon and etafilcon A with polyvinylpyrrolidone (PVP)] were incubated in an artificial tear solution for 16?h. Total activity was determined using a standard turbidity assay. The surface activity of the deposited lysozyme was determined using a modified turbidity assay. The amount of active lysozyme present within the bulk of the lens material was calculated by determining the difference between the total and surface active lysozyme.

Results

The etafilcon A materials showed the highest amount of total lysozyme activity (519?±?8?μg/lens, average of Moist and Define), followed by the ocufilcon material (200?±?5?μg/lens) and these two were significantly different from each other (p?<?0.05). The amount of surface active lysozyme on etafilcon and ocufilcon lens materials was significantly higher than that found on all other lenses (p?<?0.05). There was no active lysozyme quantified in the bulk of the nelfilcon material, as all of the active lysozyme was found on the surface (1.7?±?0.3?μg/lens). In contrast, no active lysozyme was quantified on the surface of polymacon, with all of the active lysozyme found in the bulk of the lens material (0.6?±?0.6?μg/lens).

Conclusions

The surface and bulk activity of lysozyme deposited on contact lenses is material dependent. Lysozyme deposited on ionic, high water content lens materials such as etafilcon A show significantly higher surface and bulk activity than many other hydrogel lens materials.  相似文献   

13.
PurposeUsing atomic force microscopy (AFM) to investigate anterior surface topography (AST) in worn and unworn, plasma surface-treated (PST) and untreated (UT) gas permeable (GP) lenses, and influence of surface topography on in vivo comfort.MethodsGP lens AST evaluated with AFM in tapping mode, using an uncoated, 40 nm symmetric tip (sampling frequency: 300 kHz), at five randomised locations, over a 100μm2 area, to produce mean average roughness (Ra) and root mean square (RMS) values for each sample. Four unworn lenses (two PST, two UT) were examined (Quasar/Boston EO material). Twenty worn lenses (ten PST, ten UT) of same design and material as unworn lenses collected after 3 months lens wear. General wearing comfort reported by visual analogue scale (VAS) at 3 months visit. For sample preparation, two worn UT GP lenses were divided into four segments; each segment underwent a different lens rinse and drying method.ResultsUnworn: UT lenses had significantly higher mean RMS and Ra values compared to PST (Mann-Whitney, p < 0.05). Worn: UT Median RMS values were significantly higher than PST (Mann-Whitney, p < 0.05). Comfort: no correlation found between general comfort and RMS or Ra scores. Sample preparation: Method 4 (purified, distilled water rinse/nitrogen gas dry) produced optimum median RMS and Ra values.ConclusionsUnworn PST GP lenses had lower Ra and RMS values compared with unworn UT GP lenses. After 3 months wear, PST lenses had smoother surface topographies than UT lenses. No relationship was found between surface topography and lens wear comfort. Sample preparation protocol directly impacts AFM results.  相似文献   

14.
Background/PurposeAlthough scleral contact lenses are prescribed with increasing frequency, little is known about their long-term effects on ocular physiology. The main goal of this paper is to predict values of oxygen transmissibility of scleral lens systems by applying the concept of resistors in series to parameters characteristic of current scleral lenses. A second aim is to find the maximal lens and post-lens tear layer thickness combinations above which hypoxia-induced corneal swelling would be found.MethodsTheoretical calculations were used to predict the oxygen transmissibility of scleral lens systems, considering several material permeabilities (Dks 100–170), varying lens thicknesses (250–500 μm), the known tear permeability (Dk of 80) and expected post-lens tear layer thicknesses (100–400 μm). The Holden–Mertz Dk/t criteria of 24 Fatt units for the central cornea and the Harvitt–Bonanno criteria of 35 Fatt units for the limbal area were used as reference points.ResultsOur calculations of oxygen transmissibility, with varying tear layer and lens thicknesses, ranged from 10 to 36.7 at the scleral lens centers and from 17.4 to 62.6 at the peripheries. Our calculations of maximum central lens thicknesses show a practical range of 250–495 μm, in conjunction with a post-lens tear layer thickness of 100–250 μm.ConclusionOur computations show that most modern scleral lenses, with recommended fitting techniques, should lead to some level of hypoxia-induced corneal swelling. Recommendations are made to minimize hypoxia-induced corneal swelling: highest Dk available (>150) lens with a maximal central thickness of 250 μm and fitted with a clearance that does not exceed 200 μm.  相似文献   

15.
SignificanceThis study set out to illustrate the trajectories of myopia control in time sequence and explore orthokeratology compliance for parents with myopic children in the first fitting within one year. Profiling these results is crucial to improving myopia control and orthokeratology care.PurposeTo obtain a better understanding of myopia control and orthokeratology care that could promote compliance with orthokeratology (ortho-K) lenses for parents with myopic children.MethodsWe conducted semi-structured qualitative interviews and pre-interview questionnaire surveys of the parent who is mainly responsible for complying to ortho-K lens care for their myopic children aged 7–12 years, including 16 mothers and 4 fathers. A framework analytical approach that involved gaining familiarity with the data to identify a thematic framework was used for data analysis. It was written in line with the COREQ (Consolidated Criteria for Reporting Qualitative Research) checklist.ResultsFive themes and twelve subthemes depicted the parents’ trajectory during myopia diagnosis, treatment, and compliance with ortho- K for their children in the first fitting within one year. Myopia control and the convenience of outdoor activities were important reasons for parents to actively ask for ortho-K lenses for their children. Parents have non-compliance behaviors after the children wore the lenses for three months, including not scheduling follow-up visits, simplifying cleaning procedures, not replacing accessories. The degree of parents’ non-compliance differed based on the uncomfortable feelings of their child’s eyes. In general, clear, unaided vision (visual acuity > 0.9) during the day was an indicator of ortho-K’s effectiveness, according to parents.ConclusionsAlthough parents play a passive role when a child is diagnosed with myopia, they take on a proactive role when deciding on ortho-K treatment. Myopia treatment for children is a long-term process. Understanding the course of treatment and non-compliance helps eye care professionals provide parents with the necessary assistance and resources, and enables myopia treatment to yield maximum effects.  相似文献   

16.
PurposeTo report on a second-generation prototype contact lens (modified lens) with enhanced optics to correct coma aberration and compare its performance with that of the prototype contact lens (conventional lens) used to optimise correction of coma aberration in keratoconus (KC).MethodsBoth lenses were designed as a set of standardised soft contact lenses (SCLs) with asymmetric powers along the posterior surface. The modified lens differs from the conventional lens in that the optical zone is decentred superiorly by 0.7 mm. The on-eye performance was compared between the SCLs and no-lens wearing in terms of manifest refraction, corrected distance visual acuity (CDVA), ocular aberrations, subjective quality of vision, and on-eye lens position relative to the pupil.ResultsThirty-four KC eyes were included. SCLs significantly decreased coma aberration compared to no-lens wear (none, 0.68 ± 0.27 μm; conventional lens, 0.37 ± 0.28 μm; modified lens, 0.19 ± 0.15 μm; P < 0.001), with the reduction in coma aberration being significantly greater with the modified lens than with the conventional lens (P = 0.018). No significant difference in manifest refraction or CDVA was found among the three conditions. Quality of vision was significantly better with the modified lens than with no SCL wear (P < 0.05) but no differences were found between the SCLs. The on-eye optical center position relative to the pupil was closer to the pupil centre using the modified lens than the conventional lens (P < 0.001).ConclusionOptimisation of the location of the optical zone in a standardised asymmetric SCL improves correction of coma aberrations and on-eye optical centration.  相似文献   

17.

Purpose

To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye.

Methods

High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear.

Results

The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality.

Conclusion

High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort.  相似文献   

18.
PurposeLipid deposition on contact lenses (CL) has traditionally been believed to reduce comfort during CL wear. The purpose of this study was to quantify lipid deposition on CL in a group of symptomatic and asymptomatic adapted CL wearers.MethodsThis was a single-masked, randomized clinical trial. Only confirmed symptomatic (comfortable lens wear time (CWT) < 8 h and a noticeable reduction in comfort over the course of the day) and asymptomatic (CWT > 10 h and minimal reduction in comfort over the course of the day) participants were recruited to participate in the study. Participants wore senofilcon A lenses in combination with a polyquaternium-based care solution (OPTI-FREE Replenish). Worn CL samples were collected on Day 14. Deposited lipid amounts from the lenses (including cholesteryl ester, cholesterol and triolein) were quantified using a liquid chromatography-mass spectrometry technique.ResultsLipid deposition was significantly higher in CL extracts of asymptomatic wearers compared to the symptomatic wearers for all lipid types quantified, including cholesteryl ester (2.1 ± 0.6 vs 1.6 ± 0.5 log μg/lens), cholesterol (1.5 ± 0.3 vs 1.1 ± 0.3 log μg/lens) and triolein (0.3 ± 0.2 vs 0.1 ± 0.1 log μg/lens) (all p < 0.002). The amount of cholesteryl ester deposited was greatest (p = 0.0001), followed by cholesterol, then triolein, for both the asymptomatic and symptomatic groups (both p = 0.0001).ConclusionThis study demonstrated that the asymptomatic group deposited a significantly greater amount of lipid on their CL. Although lipid levels measured are considered low to trigger any observable clinical deposition, they may influence other clinical outcomes, particularly comfort.  相似文献   

19.
PurposeTo evaluate the clinical effect of orthokeratology in controlling myopia and treating anisometropia among children with myopic anisometropia.MethodsA total of 108 myopic anisometropic children aged 8–16 years old who wore orthokeratology lenses in both eyes were enrolled in this study and followed up for over 1 year. The more severely myopic eye of each patient was assigned to the more myopic group (108 eyes), with a mean spherical equivalent refraction of −4.25 (−5.00, −3.38) D; the opposite eye of each patient was assigned to the less myopic group (108 eyes), with a refraction of −2.75 (−3.63, −1.88) D. This study observed and analyzed changes in ocular parameters after orthokeratology (Wilcoxon signed-rank test).ResultsIn children who wore orthokeratology lenses for approximately 1 year, the level of anisometropia significantly dropped from 1.38 (1.13, 1.75) D to 1.25 (1.13, 1.75) D (P = .005). The difference between the axial lengths of the two eyes significantly dropped from 0.54 (0.37, 0.74) mm to 0.46 (0.28, 0.67) mm (P< .0001).ConclusionsOrthokeratology seemed to be more effective at delaying the progression of myopia in the more myopic eyes than in the less myopic eyes of myopic anisometropic children. Orthokeratology lenses are suitable for anisometropic children, although the effectiveness of orthokeratology against anisometropia requires additional follow-up time for further observation and study.  相似文献   

20.
PurposeTo document contact lens prescribing trends in the United Kingdom over the past quarter of a century.MethodsAn annual survey of contact lens prescribing was conducted each year from 1996 to 2020, inclusive, by asking a random selection of optometrists and contact lens opticians to provide information relating to 10 consecutive contact lens fits between January and March.ResultsOver the 25 year survey period, 2,671 practitioners returned survey forms, reporting a total of 25,575 contact lens fits. The mean (± standard deviation) age of lens wearers was 35 ± 15 years, of which 64 % were female. Over the survey period, rigid lens new fits decreased from 22 % to 2%. The prescribing of silicone hydrogel lenses has increased steadily since their introduction towards the end of the 1990s, and now represent 80 % of soft lens fits. Soft toric lens prescribing has gradually increased to 47 % – a value at which astigmatism ≥ 0.75DC is theoretically corrected in all contact lens wearers. Daily disposable prescribing increased steadily over the survey period and now represents 63 % of lenses prescribed. Extended wear fits remain at very low levels, except for some prescribing for overnight orthokeratology. Multi-purpose lens care solutions are ubiquitous; peroxide and other systems are now seldom prescribed. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full time basis, whereas daily disposable soft lenses are mainly worn part time.ConclusionsThis report documents the evolution of contact lens fitting in the United Kingdom over the past 25 years. The most likely lens fit is a spherical design silicone hydrogel daily disposable contact lens prescribed for a 35 year old female and worn on a part-time basis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号