首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Both, ozone and chlorine dioxide are highly selective oxidants. Based on reaction kinetics predictions of their reactions with micropollutants are possible. The availability of reaction-rate constants is discussed. Of further interest is the role of secondary oxidants (.OH radicals) which are produced during decomposition of ozone. Also their effects on micropollutants can be quantified when the .OH radical scavenging-efficiency of the water and the rate of ozone decomposition are calibrated.  相似文献   

2.
Five oxidants, ozone, chlorine dioxide, chlorine, permanganate, and ferrate were studied with regard to the formation of assimilable organic carbon (AOC) and oxalate in absence and presence of cyanobacteria in lake water matrices. Ozone and ferrate formed significant amounts of AOC, i.e. more than 100 μg/L AOC were formed with 4.6 mg/L ozone and ferrate in water with 3.8 mg/L dissolved organic carbon. In the same water samples chlorine dioxide, chlorine, and permanganate produced no or only limited AOC. When cyanobacterial cells (Aphanizomenon gracile) were added to the water, an AOC increase was detected with ozone, permanganate, and ferrate, probably due to cell lysis. This was confirmed by the increase of extracellular geosmin, a substance found in the selected cyanobacterial cells. AOC formation by chlorine and chlorine dioxide was not affected by the presence of the cells. The formation of oxalate upon oxidation was found to be a linear function of the oxidant consumption for all five oxidants. The following molar yields were measured in three different water matrices based on oxidant consumed: 2.4-4.4% for ozone, 1.0-2.8% for chlorine dioxide and chlorine, 1.1-1.2% for ferrate, and 11-16% for permanganate. Furthermore, oxalate was formed in similar concentrations as trihalomethanes during chlorination (yield ∼ 1% based on chlorine consumed). Oxalate formation kinetics and stoichiometry did not correspond to the AOC formation. Therefore, oxalate cannot be used as a surrogate for AOC formation during oxidative water treatment.  相似文献   

3.
Wang P  He YL  Huang CH 《Water research》2011,45(4):1838-1846
Tetracyclines (TCs) are a group of widely used antibiotics that have been frequently found in the aquatic environment. The potential reactions of TCs with common water disinfection oxidants such as chlorine dioxide (ClO2) and free available chlorine (FAC) have not been studied in depth and are the focus of this study. The oxidation kinetics of tetracycline, oxytetracycline, chlorotetracycline and iso-chlorotetracycline by ClO2 and FAC are very rapid (with large apparent second-order rate constants kapp = 2.24 × 105-1.26 × 106 M−1 s−1 with ClO2 and kapp = 1.12 × 104-1.78 × 106 M−1 s−1 with FAC at pH 7.0) and highly dependent on pH. Species-specific rate constants are obtained by kinetic modeling that incorporates pH-speciation of TCs and the oxidants (for FAC), and reveal that TCs primarily react with ClO2 and FAC by their unprotonated dimethylamino group and deprotonated phenolic-diketone group. The modest difference in reactivity among the four TCs toward the oxidants is consistent with expectation and can be explained by structural influences on the two reactive moieties. Product evaluation shows that oxidation of TCs by ClO2 leads to (hydr)oxylation and breakage of TC molecules, while oxidation of TCs by FAC leads to chlorinated and (hydr)oxylated products without any substantial ring breakage. Results of this study indicate that rapid transformation of TCs by oxidants such as ClO2 and FAC under water and wastewater treatment conditions can be expected.  相似文献   

4.
The energy consumptions of conventional ozonation and the AOPs O3/H2O2 and UV/H2O2 for transformation of organic micropollutants, namely atrazine (ATR), sulfamethoxazole (SMX) and N-nitrosodimethylamine (NDMA) were compared. Three lake waters and a wastewater were assessed. With p-chlorobenzoic acid (pCBA) as a hydroxyl radical (OH) probe compound, we experimentally determined the rate constants of organic matter of the selected waters for their reaction with OH (kOH,DOM), which varied from 2.0 × 104 to 3.5 × 104 L mgC−1 s−1. Based on these data we calculated OH scavenging rates of the various water matrices, which were in the range 6.1-20 × 104 s−1. The varying scavenging rates influenced the required oxidant dose for the same degree of micropollutant transformation. In ozonation, for 90% pCBA transformation in the water with the lowest scavenging rate (lake Zürich water) the required O3 dose was roughly 2.3 mg/L, and in the water with the highest scavenging rate (Dübendorf wastewater) it was 13.2 mg/L, corresponding to an energy consumption of 0.035 and 0.2 kWh/m3, respectively. The use of O3/H2O2 increased the rate of micropollutant transformation and reduced bromate formation by 70%, but the H2O2 production increased the energy requirements by 20-25%. UV/H2O2 efficiently oxidized all examined micropollutants but energy requirements were substantially higher (For 90% pCBA conversion in lake Zürich water, 0.17-0.75 kWh/m3 were required, depending on the optical path length). Energy requirements between ozonation and UV/H2O2 were similar only in the case of NDMA, a compound that reacts slowly with ozone and OH but is transformed efficiently by direct photolysis.  相似文献   

5.
6.
The kinetics of oxidation and disinfection processes during ozonation in a full-scale reactor treating secondary wastewater effluent were investigated for seven ozone doses ranging from 0.21 to 1.24 g O3 g−1 dissolved organic carbon (DOC). Substances reacting fast with ozone, such as diclofenac or carbamazepine (kP,O3 > 104 M−1 s−1), were eliminated within the gas bubble column, except for the lowest ozone dose of 0.21 g O3 g−1 DOC. For this low dose, this could be attributed to short-circuiting within the reactor. Substances with lower ozone reactivity (kP,O3 < 104 M−1 s−1) were only fully eliminated for higher ozone doses.The predictions of micropollutant oxidation based on coupling reactor hydraulics with ozone chemistry and reaction kinetics were up to a factor of 2.5 higher than full-scale measurements. Monte Carlo simulations showed that the observed differences were higher than model uncertainties. The overestimation of micropollutant oxidation was attributed to a protection of micropollutants from ozone attack by the interaction with aquatic colloids. Laboratory-scale batch experiments using wastewater from the same full-scale treatment plant could predict the oxidation of slowly-reacting micropollutants on the full-scale level within a factor of 1.5. The Rct value, the experimentally determined ratio of the concentrations of hydroxyl radicals and ozone, was identified as a major contribution to this difference.An increase in the formation of bromate, a potential human carcinogen, was observed with increasing ozone doses. The final concentration for the highest ozone dose of 1.24 g O3 g−1 DOC was 7.5 μg L−1, which is below the drinking water standard of 10 μg L−1. N-Nitrosodimethylamine (NDMA) formation of up to 15 ng L−1 was observed in the first compartment of the reactor, followed by a slight elimination during sand filtration. Assimilable organic carbon (AOC) increased up to 740 μg AOC L−1, with no clear trend when correlated to the ozone dose, and decreased by up to 50% during post-sand filtration. The disinfection capacity of the ozone reactor was assessed to be 1-4.5 log units in terms of total cell counts (TCC) and 0.5 to 2.5 log units for Escherichia coli (E. coli). Regrowth of up to 2.5 log units during sand filtration was observed for TCC while no regrowth occurred for E. coli. E. coli inactivation could not be accurately predicted by the model approach, most likely due to shielding of E. coli by flocs.  相似文献   

7.
Baeza C  Knappe DR 《Water research》2011,45(15):4531-4543
Factors controlling photolysis and UV/H2O2 photooxidation rates of the biochemically active compounds (BACs) sulfamethoxazole, sulfamethazine, sulfadiazine, trimethoprim, bisphenol A, and diclofenac were determined. Experiments were conducted with a quasi-collimated beam apparatus equipped with low-pressure UV lamps. The effects of pH, H2O2 concentration, and background water matrix (ultrapure water, lake water, wastewater treatment plant effluent) on BAC transformation rates were evaluated. For the sulfa drugs, solution pH affected direct photolysis rates but had little effect on the hydroxyl radical oxidation rate. For sulfamethoxazole, the neutral form photolyzed more easily than the anionic form while the reverse was the case for sulfamethazine and sulfadiazine. For trimethoprim, the hydroxyl radical oxidation rate was higher for the cationic form (pH 3.6) than for the neutral form (pH 7.85). Quantum yields and second order rate constants describing the reaction between the hydroxyl radical and BACs were determined and used together with background water quality data to predict fluence-based BAC transformation rate constants (k′). For both the lake water and wastewater treatment plant effluent matrices, predicted k′ values were generally in good agreement with experimentally determined k′ values. At typical UV/H2O2 treatment conditions (fluence = 540 mJ cm−2, H2O2 dose = 6 mg L−1), BAC transformation percentages in North Carolina lake water ranged from 43% for trimethoprim to 98% for diclofenac. In wastewater treatment plant effluent, BAC transformation percentages were lower (31-97%) at the same treatment conditions because the hydroxyl radical scavenging rate was higher.  相似文献   

8.
The purpose of this project was to compare the ability of chlorine (HOCl/OCl) and monochloramine (NH2Cl) to mobilize mercury from dental amalgam. Two types of amalgam were used in this investigation: laboratory-prepared amalgam and samples obtained from dental-unit wastewater. For disinfectant exposure simulations, 0.5 g of either the laboratory-generated or clinically obtained amalgam waste was added to 250 mL amber bottles. The amalgam samples were agitated by end-over-end rotation at 30 rpm in the presence of 1 mg/L chlorine, 10 mg/L chlorine, 1 mg/L monochloramine, 10 mg/L monochloramine, or deionized water for intervals of 0 h, 2 h, 4 h, 8 h, and 24 h for the clinically obtained amalgam waste samples and 4 h and 24 h for the laboratory-prepared samples. Chlorine and monochloramine concentrations were measured with a spectrophotometer. Samples were filtered through a 0.45 µm membrane filter and analyzed for mercury with USEPA standard method 245.7. When the two sample types were combined, the mean mercury level in the 1 mg/L chlorine group was 0.020 mg/L (n = 25, SD = 0.008). The 10 mg/L chlorine group had a mean mercury concentration of 0.59 mg/L (n = 25, SD = 1.06). The 1 mg/L chloramine group had a mean mercury level of 0.023 mg/L (n = 25, SD = 0.010). The 10 mg/L chloramine group had a mean mercury level of 0.024 mg/L (n = 25, SD = 0.011). Independent samples t-tests showed that there was a significant difference between the natural log mercury measurements of 10 mg/L chlorine compared to those of 1 mg/L and 10 mg/L chloramine. Changing from chlorine to chloramine disinfection at water treatment plants would not be expected to produce substantial increases in dissolved mercury levels in dental-unit wastewater.  相似文献   

9.
Son H  Cho M  Kim J  Oh B  Chung H  Yoon J 《Water research》2005,39(4):721-727
To the best of our knowledge, this study is the first investigation to be performed into the potential benefits of mechanically mixed disinfectants in controlling bacterial inactivation. The purpose of this study was to evaluate the disinfection efficiency of mechanically mixed oxidants with identical oxidant concentrations, which were made by adding small amounts of subsidiary oxidants, namely ozone (O3), chlorine dioxide (ClO2), hydrogen peroxide (H2O2) and chlorite (ClO2(-)), to free available chlorine (Cl2), using Bacillus subtilis spores as the indicator microorganisms. The mechanically mixed oxidants containing Cl2/O3, Cl2/ClO2 and Cl2/ClO2(-) showed enhanced efficiencies (of up to 52%) in comparison with Cl2 alone, whereas no significant difference was observed between the mixed oxidant, Cl2/H2O2, and Cl2 alone. This enhanced disinfection efficiency can be explained by the synergistic effect of the mixed oxidant itself and the effect of intermediates such as ClO2(-)/ClO2, which are generated from the reaction between an excess of Cl2 and a small amount of O3/ClO2(-). Overall, this study suggests that mechanically mixed oxidants incorporating excess chlorine can constitute a new and moderately efficient method of disinfection.  相似文献   

10.
Inactivation of environmental mycobacteria by free chlorine and UV   总被引:1,自引:0,他引:1  
The resistance of environmental mycobacteria (EM) against chlorine and ultraviolet (UV) was evaluated for determination of the Ct value and UV dose to inactivate EM. Chlorine disinfection experiments were done on Mycobacterium fortuitum in oxidant demand-free buffered water at the worst condition (pH 8.5, 4 °C) and normal condition (pH 7.0, 20 °C). The Ct value for 3 log inactivation of M. fortuitum was 600 times greater than that of Escherichia coli. UV experiments were performed for various species of Mycobacterium avium, M. fortuitum, Mycobacterium intracellulare, and Mycobacterium lentiflavum. A UV collimated beam device was used for irradiation of four species suspended in phosphate buffered saline with doses of 5, 10, 20, 50, and 100 mJ/cm2. UV sensitivity of mycobacteria was species-specific. More than 3 log of M. avium, M. intracellulare, and M. lentiflavum could be inactivated at 20 mJ/cm2, whereas M. fortuitum was so resistant that 3 log inactivation required a dose of more than 50 mJ/cm2. Mycobacteria were found 2-10 times more resistant to UV than E. coli for 3 log inactivation. There was no significant difference in the inactivation of mycobacteria with either low-pressure or medium-pressure UV irradiation.  相似文献   

11.
Wang X  Hu X  Wang H  Hu C 《Water research》2012,46(4):1225-1232
The effectiveness of UV and chlorination, used individually and sequentially, was investigated in killing pathogenic microorganisms and inhibiting the formation of disinfection by-products in two different municipal wastewaters for the source water of reclaimed water, which were from a microfilter (W1) and membrane bioreactor (W2) respectively. Heterotrophic plate count (HPC), total bacteria count (TBC), and total coliform (TC) were selected to evaluate the efficiency of different disinfection processes. UV inactivation of the three bacteria followed first-order kinetics in W1 wastewater, but in W2 wastewater, the UV dose-response curve trailed beyond approximately 10 mJ/cm2 UV. The higher number of particles in the W2 might have protected the bacteria against UV damage, as UV light alone was not effective in killing HPC in W2 wastewater with higher turbidity. However, chlorine was more effective in W2 than in W1 for the three bacteria inactivation owing to the greater formation of inorganic and organic chloramines in W1 wastewater. Complete inactivation of HPC in W1 wastewater required a chlorine dose higher than 5.5 mg/L, whereas 4.5 mg/L chlorine gave the equivalent result in W2 wastewater. In contrast, sequential UV and chlorine treatment produced a synergistic effect in both wastewater systems and was the most effective option for complete removal of all three bacteria. UV disinfection lowered the required chlorine dose in W1, but not in W2, because of the higher chlorine consumption in W2 wastewater. However, UV irradiation decreased total trihalomethane formation during chlorination in both wastewaters.  相似文献   

12.
Yang B  Ying GG  Zhao JL  Liu S  Zhou LJ  Chen F 《Water research》2012,46(7):2194-2204
We investigated the removal efficiencies of 68 selected endocrine disrupting chemicals (EDCs) and pharmaceuticals and personal care products (PPCPs) spiked in a wastewater matrix by ferrate (Fe(VI)) and further evaluated the degradation of these micropollutants present in secondary effluents of two wastewater treatment plants (WWTPs) by applying Fe(VI) treatment technology. Fe(VI)treatment resulted in selective oxidation of electron-rich organic moieties of these target compounds, such as phenol, olefin, amine and aniline moieties. But Fe(VI) failed to react with triclocarban, 3 androgens, 7 acidic pharmaceuticals, 2 neutral pharmaceuticals and erythromycin-H2O.Thirty-one target EDCs and PPCPs were detected in the effluents of the two WWTPs with concentrations ranging from 0.2 ± 0.1 ng L−1 to 1156 ± 182 ng L−1.Fe(VI) treatment resulted in further elimination of the detected EDCs and PPCPs during Fe(VI) treatment of the secondary wastewater effluents. The results from this study clearly demonstrated the effectiveness of Fe(VI) treatment as a tertiary treatment technology for a broad spectrum of micropollutants in wastewater.  相似文献   

13.
C Liu  V Nanaboina  GV Korshin  W Jiang 《Water research》2012,46(16):5235-5246
This study addressed the formation and properties of degradation products of ciprofloxacin, norfloxacin and lomefloxacin formed during ozonation of secondary wastewater effluent containing these fluoroquinolone antibiotics. The generation of the degradation products was interpreted in the context of transformations of effluent organic matter (EfOM) tracked via absorbance measurements. The structures of 20 degradation products were elucidated for ciprofloxacin and norfloxacin, respectively. 27 degradation products were identified for lomefloxacin. The prevalent oxidation pathways were suggested based on the structures of the identified products formed in the absence and presence of the hydroxyl radical scavenger t-butanol. These pathways were largely similar for all studied fluoroquinolones and involved attacks on the piperazine ring and the quinolone structure. The quinolone ring remained intact in the presence of t-butanol thus indicating that this functional group could only be oxidized by OH radicals while the piperazine ring was readily oxidized by molecular ozone. The cleavage of the quinolone moiety that resulted in several identified degradation products occurred via the attack by hydroxyl radicals on the carbon-carbon double bond adjacent to the carboxylic acid group. Lomefloxacin had more diverse oxidation products due to the presence of a methyl group on its piperazinyl ring. The concentrations of the identified degradation products behaved non-monotonically as a function of ozone dose or treatment time, yet exhibited interpretable correlations versus changes of EfOM absorbance. Examination of these correlations allowed developing a novel approach for elucidating the transformations of fluoroquinolone antibiotics during ozonation.  相似文献   

14.
Amino acids and peptides may form potentially harmful disinfection byproducts during the conventional treatment of water and wastewater. Removal of these parent compounds by the use of the environmental-friendly oxidant, ferrate(VI) (FeVIO42−, Fe(VI)) was assessed by studying the kinetics of the oxidation of glycine (NH3+CH2COOH, Gly) and glycylglycine (NH3+CH2CONHCH2COOH, Gly-Gly) as a function of pH (4.0-12.4) at 25 °C. This study with Gly-Gly represents an initial investigation of oxidation of peptides by Fe(VI). Generally, the second-order rate constant (k) increased with decreased pH in the basic pH region, but this trend was reversed in the acidic pH range. Consideration of the reactivity of three oxidants (H2FeO4, HFeO4, and FeO42−) with three species of Gly and Gly-Gly (positive, neutral, and negative) reasonably explained the pH dependence of the rates. At pH 9.0, the molar consumption of Fe(VI) was nearly equal to that of Gly. The reaction of Fe(VI) with Gly at molar ratios of 1.0 and 2.0 ([Fe(VI)]:[Gly]) produced ammonia, carbon dioxide, and acetate. A reaction scheme is proposed which explains the formation of these products. The values of k for oxidation of iminodiacetate and nitriloacetate at pH 7.0 were also determined in order to compare oxidation of amines by Fe(VI). The calculated half-lives at neutral pH for the oxidation of primary and secondary amines were in seconds while decomposition of tertiary amines would occur in minutes. Overall, the reactivity of Fe(VI) with Gly and Gly-Gly indicates the significant potential of Fe(VI) to remove amine- and peptide-containing pollutants in water and wastewater.  相似文献   

15.
A newly isolated enteric virus has recently been found to be associated with large outbreaks of waterborne gastroenteritis. Most commonly referred to as the Norwalk agent, this virus appears to be morphologically and biophysically similar to the parvoviruses. In this study the parvovirus H-1, a putative human virus containing single-stranded DNA, was used as a model virus for chlorine inactivation experiments. The objective of this research was to investigate the kinetics of inactivation of this virus by low levels of free chlorine (0.05–0.20 mgl−1) at pH 7 and at 5, 10, 20 and 30°C.Inactivation occurred in the usual dose-response relationship, that is, increasing the chlorine dose caused an increase in the rate of inactivation. The energy required for the inactivation reaction using 0.05 mgl−1 free chlorine from 5 to 30°C was graphically determined to be 2.4 kcal mol−1. The change in entropy was calculated to be -52.34 entropy units. For disinfection purposes, the time required for 99% inactivation of H-1 parvovirus at pH 7.20°C and a chlorine dose of 0.2 mgl−1 free chlorine was 3.2 min. The parvovirus H-1 appeared to be less resistant to free chlorine than poliovirus type 1 (LSc).  相似文献   

16.
Jin J  El-Din MG  Bolton JR 《Water research》2011,45(4):1890-1896
Several organic compounds were used as radical scavengers/reagents to investigate the possibility of the UV/chlorine process being used as an advanced oxidation process (AOP) in the treatment of drinking water and wastewater. The UV/H2O2 process was selected as a reference, so that the results from the UV/chlorine process could be compared with those of the UV/H2O2 process. Methanol was added to active chlorine solutions at both pH 5 and 10 and into hydrogen peroxide samples. The photodegradation quantum yields and the OH radical production yield factors, which are significant in evaluating AOPs, were calculated for both the UV/chlorine and the UV/H2O2 processes. The yield factor for the UV/chlorine process at pH 5 was 0.46 ± 0.09, which is much lower than that of the UV/H2O2 process, which reached 0.85 ± 0.04. In addition to methanol, para-chlorobenzoic acid (pCBA) and cyclohexanoic acid (CHA) were added to active chlorine solutions and to H2O2 solutions, to evaluate the efficiencies of oxidizing these organic compounds. The specific first-order reaction rate constants for the oxidation of pCBA and CHA, using the UV/chlorine process, were lower than those found using the UV/H2O2 process.  相似文献   

17.
Lee CO  Howe KJ  Thomson BM 《Water research》2012,46(4):1005-1014
This pilot-scale research project investigated and compared the removal of pharmaceuticals and personal care products (PPCPs) and other micropollutants from treated wastewater by ozone/biofiltration and reverse osmosis (RO). The reduction in UV254 absorbance as a function of ozone dose correlated well with the reduction in nonbiodegradable dissolved organic carbon and simultaneous production of biodegradable dissolved organic carbon (BDOC). BDOC analyses demonstrated that ozone does not mineralize organics in treated wastewater and that biofiltration can remove the organic oxidation products of ozonation. Biofiltration is recommended for treatment of ozone contactor effluent to minimize the presence of unknown micropollutant oxidation products in the treated water. Ozone/biofiltration and RO were compared on the basis of micropollutant removal efficiency, energy consumption, and waste production. Ozone doses of 4-8 mg/L were nearly as effective as RO for removing micropollutants. When wider environmental impacts such as energy consumption, water recovery, and waste production are considered, ozone/biofiltration may be a more desirable process than RO for removing PPCPs and other trace organics from treated wastewater.  相似文献   

18.
C.H. Rav-Acha  R. Blits 《Water research》1985,19(10):1273-1281
The removal of PAH from surface water by disinfectants like chlorine or chlorine dioxide is important where contamination by these compounds is concerned and no other water treatment processes are available. Our particular interest in these reactions arise from the fact that PAH can be used as an excellent model for the investigation of the different mechanisms by which the two oxidants react with aquatic organics. The vast differences between the rates of Cl2 and ClO2 reactions with various PAH, as well as the physical and chemical factors influencing those reactions indicate that chlorine reacts with PAH by several possible mechanisms, e.g. addition, substitution and oxidation. Chlorine dioxide on the other hand reacts mainly as a pure oxidant and a one-electron acceptor. As a consequence, chlorine dioxide reacts much more specifically with those PAH that undergo facile oxidation. Therefore, some PAH that react quite easily with Cl2, do not react at all with ClO2, while other PAH react with ClO2 much more rapidly than with Cl2. The widespread and highly carcinogenic benzo(a)pyrene and benzo(a)anthracene for example react with ClO2 much faster than with Cl2.  相似文献   

19.
The contribution of volatilization, sorption and transformation to the removal of 16 Pharmaceutical and Personal Care Products (PPCPs) in two lab-scale conventional activated sludge reactors, working under nitrifying (aerobic) and denitrifying (anoxic) conditions for more than 1.5 years, have been assessed. Pseudo-first order biological degradation rate constants (kbiol) were calculated for the selected compounds in both reactors. Faster degradation kinetics were measured in the nitrifying reactor compared to the denitrifying system for the majority of PPCPs. Compounds could be classified according to their kbiol into very highly (kbiol > 5 L gSS−1 d−1), highly (1 < kbiol < 5 L gSS−1 d−1), moderately (0.5 < kbiol < 1 L gSS−1 d−1) and hardly (kbiol < 0.5 L gSS−1 d−1) biodegradable.Results indicated that fluoxetine (FLX), natural estrogens (E1 + E2) and musk fragrances (HHCB, AHTN and ADBI) were transformed to a large extent under aerobic (>75%) and anoxic (>65%) conditions, whereas naproxen (NPX), ethinylestradiol (EE2), roxithromycin (ROX) and erythromycin (ERY) were only significantly transformed in the aerobic reactor (>80%). The anti-depressant citalopram (CTL) was moderately biotransformed under both, aerobic and anoxic conditions (>60% and >40%, respectively). Some compounds, as carbamazepine (CBZ), diazepam (DZP), sulfamethoxazole (SMX) and trimethoprim (TMP), manifested high resistance to biological transformation.Solids Retention Time (SRTaerobic >50 d and <50 d; SRTanoxic >20 d and <20 d) had a slightly positive effect on the removal of FLX, NPX, CTL, EE2 and natural estrogens (increase in removal efficiencies <10%). Removal of diclofenac (DCF) in the aerobic reactor was positively affected by the development of nitrifying biomass and increased from 0% up to 74%. Similarly, efficient anoxic transformation of ibuprofen (75%) was observed after an adaptation period of 340 d. Temperature (16-26 °C) only had a slight effect on the removal of CTL which increased in 4%.  相似文献   

20.
OS Keen  NG Love  KG Linden 《Water research》2012,46(16):5224-5234
Most conventional biological treatment wastewater treatment plants (WWTPs) contain nitrate in the effluent. Nitrate undergoes photolysis when irradiated with ultraviolet (UV) light in the 200-240 and 300-325 nm wavelength range. In the process of nitrate photolysis, nitrite and hydroxyl radicals are produced. Medium pressure mercury lamps emitting a polychromatic UV spectrum including irradiation below 240 nm are becoming more common for wastewater disinfection. Therefore, nitrified effluent irradiated with polychromatic UV could effectively become a de facto advanced oxidation (hydroxyl radical) treatment process. UV-based advanced oxidation processes commonly rely on addition of hydrogen peroxide in the presence of UV irradiation for production of hydroxyl radicals. This study compares the steady-state concentration of hydroxyl radicals produced by nitrate contained in a conventional WWTP effluent to that produced by typical concentrations of hydrogen peroxide used for advanced oxidation treatment of water. The quantum yield of hydroxyl radical production from nitrate by all pathways was calculated to be 0.24 ± 0.03, and the quantum yield of hydroxyl radicals from nitrite was calculated to be 0.65 ± 0.06. A model was developed that would estimate production of hydroxyl radicals directly from nitrate and water quality parameters. In effluents with >5 mg-N/L of nitrate, the concentration of hydroxyl radicals is comparable to that produced by addition of 10 mg/L of H2O2. Nitrifying wastewater treatment plants utilizing polychromatic UV systems at disinfection dose levels can be expected to achieve up to 30% degradation of some micropollutants by hydroxyl radical oxidation. Increasing UV fluence to levels used during advanced oxidation could achieve over 95% degradation of some compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号